sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Winternitz, Luke

Normalized to: Winternitz, L.

2 article(s) in total. 59 co-authors, from 1 to 2 common article(s). Median position in authors list is 18,5.

[1]  oai:arXiv.org:1902.07130  [pdf] - 1863991
High-Precision X-ray Timing of Three Millisecond Pulsars with NICER: Stability Estimates and Comparison with Radio
Comments: 30 pages, 15 figures; accepted to ApJ
Submitted: 2019-02-19
The Neutron Star Interior Composition Explorer (NICER) is an X-ray astrophysics payload on the International Space Station. It enables unprecedented high-precision timing of millisecond pulsars without the pulse broadening and delays due to dispersion and scattering within the interstellar medium that plague radio timing. We present initial timing results from a year of data on the millisecond pulsars PSR B1937+21 and PSR J0218+4232, and nine months of data on PSR B1821-24. NICER time-of-arrival uncertainties for the three pulsars are consistent with theoretical lower bounds and simulations based on their pulse shape templates and average source and background photon count rates. To estimate timing stability, we use the $\sigma_z$ measure, which is based on the average of the cubic coefficients of polynomial fits to subsets of timing residuals. So far we are achieving timing stabilities $\sigma_z \approx 3 \times 10^{-14}$ for PSR B1937+21 and on the order of $10^{-12}$ for PSRs B1821$-$24 and J0218+4232. Within the span of our \textit{NICER} data we do not yet see the characteristic break point in the slope of $\sigma_z$; detection of such a break would indicate that further improvement in the cumulative root-mean-square (RMS) timing residual is limited by timing noise. We see this break point in our comparison radio data sets for PSR B1821-24 and PSR B1937+21 on time scales of $> 2$ years.
[2]  oai:arXiv.org:1805.11906  [pdf] - 1721149
NICER Detects a Soft X-ray Kilohertz Quasi-periodic Oscillation in 4U 0614+09
Comments: proof correction applied. 7 pages, 3 figures, 1 table, accepted for publication in ApJ Letters
Submitted: 2018-05-30, last modified: 2018-07-24
We report on the detection of a kilohertz quasi-periodic oscillation (QPO) with the Neutron Star Interior Composition Explorer (NICER). Analyzing approximately 165 ks of NICER exposure on the X-ray burster 4U 0614+09, we detect multiple instances of a single-peak upper kHz QPO, with centroid frequencies that range from 400 Hz to 750 Hz. We resolve the kHz QPO as a function of energy, and measure, for the first time, the QPO amplitude below 2 keV. We find the fractional amplitude at 1 keV is on the order of 2% rms, and discuss the implications for the QPO emission process in the context of Comptonization models.