Normalized to: Winkelmann, C.
[1]
oai:arXiv.org:physics/0611273 [pdf] - 119197
Bolometric calibration of a superfluid $^3$He detector for Dark Matter
search: direct measurement of the scintillated energy fraction for neutron,
electron and muon events
Submitted: 2006-11-28
We report on the calibration of a superfluid $^3$He bolometer developed for
the search of non-baryonic Dark Matter. Precise thermometry is achieved by the
direct measurement of thermal excitations using Vibrating Wire Resonators
(VWRs). The heating pulses for calibration were produced by the direct quantum
process of quasiparticle generation by other VWRs present. The bolometric
calibration factor is analyzed as a function of temperature and excitation
level of the sensing VWR. The calibration is compared to bolometric
measurements of the nuclear neutron capture reaction and heat depositions by
cosmic muons and low energy electrons. The comparison allows a quantitative
estimation of the ultra-violet scintillation rate of irradiated helium,
demonstrating the possibility of efficient electron recoil event rejection.
[2]
oai:arXiv.org:astro-ph/0604024 [pdf] - 387099
An analysis method for time ordered data processing of Dark Matter
experiments
Submitted: 2006-04-03
The analysis of the time ordered data of Dark Matter experiments is becoming
more and more challenging with the increase of sensitivity in the ongoing and
forthcoming projects. Combined with the well-known level of background events,
this leads to a rather high level of pile-up in the data. Ionization,
scintillation as well as bolometric signals present common features in their
acquisition timeline: low frequency baselines, random gaussian noise, parasitic
noise and signal characterized by well-defined peaks. In particular, in the
case of long-lasting signals such as bolometric ones, the pile-up of events may
lead to an inaccurate reconstruction of the physical signal (misidentification
as well as fake events). We present a general method to detect and extract
signals in noisy data with a high pile-up rate and qe show that events from few
keV to hundreds of keV can be reconstructed in time ordered data presenting a
high pile-up rate. This method is based on an iterative detection and fitting
procedure combined with prior wavelet-based denoising of the data and baseline
subtraction. {We have tested this method on simulated data of the MACHe3
prototype experiment and shown that the iterative fitting procedure allows us
to recover the lowest energy events, of the order of a few keV, in the presence
of background signals from a few to hundreds of keV. Finally we applied this
method to the recent MACHe3 data to successfully measure the spectrum of
conversion electrons from Co57 source and also the spectrum of the background
cosmic muons.
[3]
oai:arXiv.org:astro-ph/0504629 [pdf] - 72726
MACHe3, a prototype for non-baryonic dark matter search: KeV event
detection and multicell correlation
Submitted: 2005-04-28
Superfluid He3 at ultra-low temperatures (100 microKelvins) is a sensitive
medium for the bolometric detection of particles. MACHe3 (MAtrix of Cells of
Helium 3) is a project for non-baryonic dark matter search using He3 as a
sensitive medium. Simulations made on a high granularity detector show a very
good rejection to background signals. A multicell prototype including 3
bolometers has been developed to allow correlations between the cells for
background event discrimination. One of the cells contains a low activity Co57
source providing conversion electrons of 7.3 and 13.6 keV to confirm the
detection of low energy events. First results on the multicell prototype are
presented. A detection threshold of 1 keV has been achieved. The detection of
low energy conversion electrons coming from the Co57 source is highlighted as
well as the cosmic muon spectrum measurement. The possibility to reject
background events by using the correlation among the cells is demonstrated from
the simultaneous detection of muons in different cells.
[4]
oai:arXiv.org:astro-ph/0504272 [pdf] - 387088
Low energy conversion electron detection in superfluid He3 at ultra-low
temperature
Submitted: 2005-04-12
We report on the first results of the MACHe3 (MAtrix of Cells of Helium 3)
prototype experiment concerning the measurement of low energy conversion
electrons at ultra-low temperature. For the first time, the feasibility of the
detection of low energy electrons is demonstrated in superfluid He3-B cooled
down to 100 microK. Low energy electrons at 7.3 keV coming from the K shell
conversion of the 14.4 keV nuclear transition of a low activity Co57 source are
detected, opening the possibility to use a He3-based detector for the detection
of Weakly Interacting Massive Particles (WIMPs) which are expected to release
an amount of energy higher-bounded by 5.6 keV.
[5]
oai:arXiv.org:astro-ph/0309325 [pdf] - 59152
Project of a superfluid He3 detector for direct detection of
non-baryonic dark matter : MACHe3
Submitted: 2003-09-11
MACHe3 (MAtrix of Cells of superfluid Helium 3) is a project of non-baryonic
Dark Matter search using superfluid He3 as sensitive medium. Simulations on a
high granularity matrix show very good rejection against background events.
First results on a prototype cell are very encouraging. Neutron detection has
been highlighted as well as cosmic muon detection. A phenomenological study has
been done with the DarkSUSY code to investigate complementarity of MACHe3 with
existing Dark Matter detectors.