Normalized to: Wincentsen, J.
[1]
oai:arXiv.org:1608.01693 [pdf] - 1531195
Flowdown of the TMT astrometry error budget(s) to the IRIS design
Schoeck, Matthias;
Andersen, David;
Rogers, John;
Ellerbroek, Brent;
Chisholm, Eric;
Dunn, Jennifer;
Herriot, Glen;
Larkin, James;
Moore, Anna;
Suzuki, Ryuji;
Wincentsen, James;
Wright, Shelley
Submitted: 2016-08-04
TMT has defined the accuracy to be achieved for both absolute and
differential astrometry in its top-level requirements documents. Because of the
complexities of different types of astrometric observations, these requirements
cannot be used to specify system design parameters directly. The TMT astrometry
working group therefore developed detailed astrometry error budgets for a
variety of science cases. These error budgets detail how astrometric errors
propagate through the calibration, observing and data reduction processes. The
budgets need to be condensed into sets of specific requirements that can be
used by each subsystem team for design purposes. We show how this flowdown from
error budgets to design requirements is achieved for the case of TMT's
first-light Infrared Imaging Spectrometer (IRIS) instrument.
[2]
oai:arXiv.org:1608.01720 [pdf] - 1531197
The Infrared Imaging Spectrograph (IRIS) for TMT: Instrument Overview
Larkin, James E.;
Moore, Anna M.;
Wright, Shelley A.;
Wincentsen, James E.;
Anderson, David;
Chisholm, Eric M.;
Dekany, Richard G.;
Dunn, Jennifer S.;
Ellerbroek, Brent L.;
Hayano, Yutaka;
Phillips, Andrew C.;
Simard, Luc;
Smith, Roger;
Suzuki, Ryuji;
Weber, Robert W.;
Weiss, Jason L.;
Zhang, Kai
Submitted: 2016-08-04
IRIS is a near-infrared (0.84 to 2.4 microns) integral field spectrograph and
wide-field imager being developed for first light with the Thirty Meter (TMT).
It mounts to the advanced optics (AO) system NFIRAOS and has integrated
on-instrument wavefront sensors (OIWFS) to achieve diffraction-limited spatial
resolution at wavelengths longer than 1 micron. With moderate spectral
resolution (R ~4,000 - 8,000) and large bandpass over a continuous field of
view, IRIS will open new opportunities in virtually every area of astrophysical
science. It will be able to resolve surface features tens of kilometers across
Titan, while also mapping the distant galaxies at the scale of an individual
star forming region. This paper summarizes the entire design and capabilities,
and includes the results from the nearly completed preliminary design phase.
[3]
oai:arXiv.org:1608.02435 [pdf] - 1531219
The Infrared Imaging Spectrograph (IRIS) for TMT: optical design of IRIS
imager with "Co-axis double TMA"
Tsuzuki, Toshihiro;
Suzuki, Ryuji;
Harakawa, Hiroki;
Ikenoue, Bungo;
Larkin, James;
Moore, Anna;
Obuchi, Yoshiyuki;
Phillips, Andrew C;
Saito, Sakae;
Uraguchi, Fumihiro;
Wincentsen, James;
Wright, Shelley;
Hayano, Yutaka
Submitted: 2016-08-04
IRIS (InfraRed Imaging Spectrograph) is one of the first-generation
instruments for the Thirty Meter Telescope (TMT). IRIS is composed of a
combination of near-infrared (0.84--2.4 $\mu$m) diffraction limited imager and
integral field spectrograph. To achieve near-diffraction limited resolutions in
the near-infrared wavelength region, IRIS uses the advanced adaptive optics
system NFIRAOS (Narrow Field Infrared Adaptive Optics System) and integrated
on-instrument wavefront sensors (OIWFS). However, IRIS itself has challenging
specifications. First, the overall system wavefront error should be less than
40 nm in Y, z, J, and H-band and 42 nm in K-band over a 34.0 $\times$ 34.0
arcsecond field of view. Second, the throughput of the imager components should
be more than 42 percent. To achieve the extremely low wavefront error and high
throughput, all reflective design has been newly proposed. We have adopted a
new design policy called "Co-Axis double-TMA", which cancels the asymmetric
aberrations generated by "collimator/TMA" and "camera/TMA" efficiently. The
latest imager design meets all specifications, and, in particular, the
wavefront error is less than 17.3 nm and throughput is more than 50.8 percent.
However, to meet the specification of wavefront error and throughput as built
performance, the IRIS imager requires both mirrors with low surface
irregularity after high-reflection coating in cryogenic and high-level Assembly
Integration and Verification (AIV). To deal with these technical challenges, we
have done the tolerance analysis and found that total pass rate is almost 99
percent in the case of gauss distribution and more than 90 percent in the case
of parabolic distribution using four compensators. We also have made an AIV
plan and feasibility check of the optical elements. In this paper, we will
present the details of this optical system.