sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Wikus, P.

Normalized to: Wikus, P.

6 article(s) in total. 147 co-authors, from 1 to 6 common article(s). Median position in authors list is 42,5.

[1]  oai:arXiv.org:1908.09010  [pdf] - 2040682
Micro-X Sounding Rocket: Transitioning from First Flight to a Dark Matter Configuration
Comments: Proceedings of the 18th International Workshop on Low Temperature Detectors (LTD18)
Submitted: 2019-08-22, last modified: 2020-01-30
The Micro-X sounding rocket flew for the first time on July 22, 2018, becoming the first program to fly Transition-Edge Sensors and multiplexing SQUID readout electronics in space. While a rocket pointing failure led to no time on-target, the success of the flight systems was demonstrated. The successful flight operation of the instrument puts the program in a position to modify the payload for indirect galactic dark matter searches. The payload modifications are motivated by the science requirements of this observation. Micro-X can achieve world-leading sensitivity in the keV regime with a single flight. Dark matter sensitivity projections have been updated to include recent observations and the expected sensitivity of Micro-X to these observed fluxes. If a signal is seen (as seen in the X-ray satellites), Micro-X can differentiate an atomic line from a dark matter signature.
[2]  oai:arXiv.org:1908.09689  [pdf] - 2022786
First Operation of TES Microcalorimeters in Space with the Micro-X Sounding Rocket
Comments: 9 pages, 6 figures, Accepted to the JLTP for LTD-18
Submitted: 2019-08-26, last modified: 2020-01-05
Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter array to perform high-resolution X-ray spectroscopy. This instrument flew for the first time on July 22nd, 2018 from the White Sands Missile Range, USA. This flight marks the first successful operation of a Transition-Edge Sensor array and its time division multiplexing read-out system in space. This launch was dedicated to the observation of the supernova remnant Cassiopeia A. A failure in the attitude control system prevented the rocket from pointing and led to no time on target. The on-board calibration source provided X-rays in flight, and it is used to compare detector performance during pre-flight integration, flight, and after the successful post-flight recovery. This calibration data demonstrates the capabilities of the detector in a space environment as well as its potential for future flights.
[3]  oai:arXiv.org:1310.3512  [pdf] - 1179917
Vibration Isolation Design for the Micro-X Rocket Payload
Comments: 6 pages, 7 figures, LTD15 Conference Proceedings
Submitted: 2013-10-13
Micro-X is a NASA-funded, sounding rocket-borne X-ray imaging spectrometer that will allow high precision measurements of velocity structure, ionization state and elemental composition of extended astrophysical systems. One of the biggest challenges in payload design is to maintain the temperature of the detectors during launch. There are several vibration damping stages to prevent energy transmission from the rocket skin to the detector stage, which causes heating during launch. Each stage should be more rigid than the outer stages to achieve vibrational isolation. We describe a major design effort to tune the resonance frequencies of these vibration isolation stages to reduce heating problems prior to the projected launch in the summer of 2014.
[4]  oai:arXiv.org:1105.3377  [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS; Collaborations, EDELWEISS; :; Ahmed, Z.; Akerib, D. S.; Armengaud, E.; Arrenberg, S.; Augier, C.; Bailey, C. N.; Balakishiyeva, D.; Baudis, L.; Bauer, D. A.; Benoît, A.; Bergé, L.; Blümer, J.; Brink, P. L.; Broniatowski, A.; Bruch, T.; Brudanin, V.; Bunker, R.; Cabrera, B.; Caldwell, D. O.; Censier, B.; Chapellier, M.; Chardin, G.; Charlieux, F.; Cooley, J.; Coulter, P.; Cox, G. A.; Cushman, P.; Daal, M.; Defay, X.; De Jesus, M.; DeJongh, F.; Di Stefano, P. C. F.; Dolgorouki, Y.; Domange, J.; Dumoulin, L.; Dragowsky, M. R.; Eitel, K.; Fallows, S.; Figueroa-Feliciano, E.; Filippini, J.; Filosofov, D.; Fourches, N.; Fox, J.; Fritts, M.; Gascon, J.; Gerbier, G.; Gironnet, J.; Golwala, S. R.; Gros, M.; Hall, J.; Hennings-Yeomans, R.; Henry, S.; Hertel, S. A.; Hervé, S.; Holmgren, D.; Hsu, L.; Huber, M. E.; Juillard, A.; Kamaev, O.; Kiveni, M.; Kluck, H.; Kos, M.; Kozlov, V.; Kraus, H.; Kudryavtsev, V. A.; Leman, S. W.; Liu, S.; Loaiza, P.; Mahapatra, R.; Mandic, V.; Marnieros, S.; Martinez, C.; McCarthy, K. A.; Mirabolfathi, N.; Moore, D.; Nadeau, P.; Navick, X-F.; Nelson, H.; Nones, C.; Ogburn, R. W.; Olivieri, E.; Pari, P.; Pattavina, L.; Paul, B.; Phipps, A.; Pyle, M.; Qiu, X.; Rau, W.; Reisetter, A.; Ricci, Y.; Robinson, M.; Rozov, S.; Saab, T.; Sadoulet, B.; Sander, J.; Sanglard, V.; Schmidt, B.; Schnee, R. W.; Scorza, S.; Seitz, D. N.; Semikh, S.; Serfass, B.; Sundqvist, K. M.; Tarka, M.; Torrento-Coello, A. S.; Vagneron, L.; Verdier, M. -A.; Walker, R. J.; Wikus, P.; Yakushev, E.; Yellin, S.; Yoo, J.; Young, B. A.; Zhang, J.
Comments: Events, efficiencies, and main limit are available in text format (see README.txt)
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90% CL. At higher WIMP masses, the combination improves the individual limits, by a factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide stronger constraints for some ranges of WIMP masses and weaker constraints for others.
[5]  oai:arXiv.org:1012.5078  [pdf] - 371990
Search for inelastic dark matter with the CDMS II experiment
Comments: 10 pages, 10 figures, minor changes to match published version, conclusion unchanged
Submitted: 2010-12-22, last modified: 2011-06-12
Results are presented from a reanalysis of the entire five-tower data set acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis window was extended to a recoil energy of 150 keV, and an improved surface-event background-rejection cut was defined to increase the sensitivity of the experiment to the inelastic dark matter (iDM) model. Three dark matter candidates were found between 25 keV and 150 keV. The probability to observe three or more background events in this energy range is 11%. Because of the occurrence of these events the constraints on the iDM parameter space are slightly less stringent than those from our previous analysis, which used an energy window of 10-100 keV.
[6]  oai:arXiv.org:1011.2482  [pdf] - 347805
Results from a Low-Energy Analysis of the CDMS II Germanium Data
Comments: 9 pages, 8 figures. Supplemental material included as ancillary files. v3) Added appendix with additional details regarding energy scale and backgrounds
Submitted: 2010-11-10, last modified: 2011-04-21
We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs) with masses below ~10 GeV/c^2. This analysis provides stronger constraints than previous CDMS II results for WIMP masses below 9 GeV/c^2 and excludes parameter space associated with possible low-mass WIMP signals from the DAMA/LIBRA and CoGeNT experiments.