oai:arXiv.org:1107.3560 [pdf] - 387460
A New Artificial Dielectric Metamaterial and its Application as a THz
Anti-Reflection Coating
Submitted: 2011-07-18
We describe a novel artificial dielectric material which has applications at
millimetre and submillimetre wavelengths. The material is manufactured from
layers of metal mesh patterned onto thin polypropylene sheets which are then
bonded together using a hot pressing process to provide planar rugged discs
which can be reliably cycled to cryogenic temperatures. The refractive index of
this material can be tuned by adjusting the geometry and spacing of the
metal-mesh layers. We demonstrate its usage by designing and characterising a
broadband anti-reflection coating for a Z-cut crystalline Quartz plate. The
coating was fabricated and applied to the quartz using the hot press technique
and characterized using a Fourier Transform Spectrometer. The performance is
shown to be in good agreement with HFSS and transmission line modelling
results.
[2]
oai:arXiv.org:1107.3567 [pdf] - 387464
Polypropylene Embedded Metal-Mesh Broadband Achromatic Half Wave Plate
for Millimeter Wavelengths
Submitted: 2011-07-18
We describe a novel multi-layered metal mesh achromatic half wave plate for
use in astronomical polarimetric instruments. The half wave plate is designed
to operate across the frequency range from 125-250 GHz. The wave plate is
manufactured from 12-layers of thin film metallic inductive and capacitive
grids patterned onto polypropylene sheets, which are then bonded together using
a hot pressing technique. Transmission line modelling and 3-D electromagnetic
simulations are used to optimize the parameters of the metal-mesh patterns and
to evaluate their optical properties. A prototype half wave plate has been
fabricated and its performance characterized in a polarizing Fourier transform
spectrometer. The device performance is consistent with the modelling although
the measured differential phase shift for two orthogonal polarizations is lower
than expected. This difference is likely to result from imperfect patterning of
individual layers and misalignment of the grids during manufacture.
[3]
oai:arXiv.org:1005.5123 [pdf] - 1032799
The Herschel-SPIRE instrument and its in-flight performance
Griffin, M. J.;
Abergel, A.;
Abreu, A.;
Ade, P. A. R.;
André, P.;
Augueres, J. -L.;
Babbedge, T.;
Bae, Y.;
Baillie, T.;
Baluteau, J. -P.;
Barlow, M. J.;
Bendo, G.;
Benielli, D.;
Bock, J. J.;
Bonhomme, P.;
Brisbin, D.;
Brockley-Blatt, C.;
Caldwell, M.;
Cara, C.;
Castro-Rodriguez, N.;
Cerulli, R.;
Chanial, P.;
Chen, S.;
Clark, E.;
Clements, D. L.;
Clerc, L.;
Coker, J.;
Communal, D.;
Conversi, L.;
Cox, P.;
Crumb, D.;
Cunningham, C.;
Daly, F.;
Davis, G. R.;
De Antoni, P.;
Delderfield, J.;
Devin, N.;
Di Giorgio, A.;
Didschuns, I.;
Dohlen, K.;
Donati, M.;
Dowell, A.;
Dowell, C. D.;
Duband, L.;
Dumaye, L.;
Emery, R. J.;
Ferlet, M.;
Ferrand, D.;
Fontignie, J.;
Fox, M.;
Franceschini, A.;
Frerking, M.;
Fulton, T.;
Garcia, J.;
Gastaud, R.;
Gear, W. K.;
Glenn, J.;
Goizel, A.;
Griffin, D. K.;
Grundy, T.;
Guest, S.;
Guillemet, L.;
Hargrave, P. C.;
Harwit, M.;
Hastings, P.;
Hatziminaoglou, E.;
Herman, M.;
Hinde, B.;
Hristov, V.;
Huang, M.;
Imhof, P.;
Isaak, K. J.;
Israelsson, U.;
Ivison, R. J.;
Jennings, D.;
Kiernan, B.;
King, K. J.;
Lange, A. E.;
Latter, W.;
Laurent, G.;
Laurent, P.;
Leeks, S. J.;
Lellouch, E.;
Levenson, L.;
Li, B.;
Li, J.;
Lilienthal, J.;
Lim, T.;
Liu, J.;
Lu, N.;
Madden, S.;
Mainetti, G.;
Marliani, P.;
McKay, D.;
Mercier, K.;
Molinari, S.;
Morris, H.;
Moseley, H.;
Mulder, J.;
Mur, M.;
Naylor, D. A.;
Nguyen, H.;
O'Halloran, B.;
Oliver, S.;
Olofsson, G.;
Olofsson, H. -G.;
Orfei, R.;
Page, M. J.;
Pain, I.;
Panuzzo, P.;
Papageorgiou, A.;
Parks, G.;
Parr-Burman, P.;
Pearce, A.;
Pearson, C.;
Pérez-Fournon, I.;
Pinsard, F.;
Pisano, G.;
Podosek, J.;
Pohlen, M.;
Polehampton, E. T.;
Pouliquen, D.;
Rigopoulou, D.;
Rizzo, D.;
Roseboom, I. G.;
Roussel, H.;
Rowan-Robinson, M.;
Rownd, B.;
Saraceno, P.;
Sauvage, M.;
Savage, R.;
Savini, G.;
Sawyer, E.;
Scharmberg, C.;
Schmitt, D.;
Schneider, N.;
Schulz, B.;
Schwartz, A.;
Shafer, R.;
Shupe, D. L.;
Sibthorpe, B.;
Sidher, S.;
Smith, A.;
Smith, A. J.;
Smith, D.;
Spencer, L.;
Stobie, B.;
Sudiwala, R.;
Sukhatme, K.;
Surace, C.;
Stevens, J. A.;
Swinyard, B. M.;
Trichas, M.;
Tourette, T.;
Triou, H.;
Tseng, S.;
Tucker, C.;
Turner, A.;
Vaccari, M.;
Valtchanov, I.;
Vigroux, L.;
Virique, E.;
Voellmer, G.;
Walker, H.;
Ward, R.;
Waskett, T.;
Weilert, M.;
Wesson, R.;
White, G. J.;
Whitehouse, N.;
Wilson, C. D.;
Winter, B.;
Woodcraft, A. L.;
Wright, G. S.;
Xu, C. K.;
Zavagno, A.;
Zemcov, M.;
Zhang, L.;
Zonca, E.
Submitted: 2010-05-27
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space
Observatory`s submillimetre camera and spectrometer. It contains a three-band
imaging photometer operating at 250, 350 and 500 microns, and an imaging
Fourier Transform Spectrometer (FTS) which covers simultaneously its whole
operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are
arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a
field of view of 4' x 8', observed simultaneously in the three spectral bands.
Its main operating mode is scan-mapping, whereby the field of view is scanned
across the sky to achieve full spatial sampling and to cover large areas if
desired. The spectrometer has an approximately circular field of view with a
diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25
GHz by changing the stroke length of the FTS scan mirror. Its main operating
mode involves a fixed telescope pointing with multiple scans of the FTS mirror
to acquire spectral data. For extended source measurements, multiple position
offsets are implemented by means of an internal beam steering mirror to achieve
the desired spatial sampling and by rastering of the telescope pointing to map
areas larger than the field of view. The SPIRE instrument consists of a cold
focal plane unit located inside the Herschel cryostat and warm electronics
units, located on the spacecraft Service Module, for instrument control and
data handling. Science data are transmitted to Earth with no on-board data
compression, and processed by automatic pipelines to produce calibrated science
products. The in-flight performance of the instrument matches or exceeds
predictions based on pre-launch testing and modelling: the photometer
sensitivity is comparable to or slightly better than estimated pre-launch, and
the spectrometer sensitivity is also better by a factor of 1.5-2.