Normalized to: Whalley, M.
[1]
oai:arXiv.org:1409.4780 [pdf] - 951797
The Visible and Infrared Survey Telescope for Astronomy (VISTA): Design,
Technical Overview and Performance
Sutherland, Will;
Emerson, Jim;
Dalton, Gavin;
Atad-Ettedgui, Eli;
Beard, Steven;
Bennett, Richard;
Bezawada, Naidu;
Born, Andrew;
Caldwell, Martin;
Clark, Paul;
Craig, Simon;
Henry, David;
Jeffers, Paul;
Little, Bryan;
McPherson, Alistair;
Murray, John;
Stewart, Malcolm;
Stobie, Brian;
Terrett, David;
Ward, Kim;
Whalley, Martin;
Woodhouse, Guy
Submitted: 2014-09-16, last modified: 2015-03-11
The Visible and Infrared Survey Telescope for Astronomy (VISTA) is the
4-metre wide-field survey telescope at ESO's Paranal Observatory, equipped with
the world's largest near-infrared imaging camera (VISTA IR Camera, VIRCAM),
with 1.65 degree diameter field of view, and 67 Mpixels giving 0.6 square
degrees active pixel area, operating at wavelengths 0.8 - 2.3 microns. We
provide a short history of the project, and an overview of the technical
details of the full system including the optical design, mirrors, telescope
structure, IR camera, active optics, enclosure and software. The system
includes several innovative design features such as the f/1 primary mirror, the
dichroic cold-baffle camera design and the sophisticated wavefront sensing
system delivering closed-loop 5-axis alignment of the secondary mirror. We
conclude with a summary of the delivered performance, and a short overview of
the six ESO public surveys in progress on VISTA.
[2]
oai:arXiv.org:1009.0434 [pdf] - 1034648
Fibre Positioning Revisited: The use an off-the-shelf assembly robot for
OPTIMOS-EVE
Submitted: 2010-09-02
The OPTIMOS-EVE instrument proposed for the E-ELT aims to use the maximum
field of view available to the E-ELT in the limit of natural or
ground-layer-corrected seeing for high multiplex fibre-fed multi-object
spectroscopy in the visible and near-IR. At the bare nasmyth focus of the
telescope, this field corresponds to a focal plane 2.3m in diameter, with a
plate-scale of ~3mm/arcsec. The required positioning accuracy that is implied
by seeing limited performance at this plate-scale brings the system into the
range of performances of commercial off-the-shelf robots that are commonly used
in industrial manufacturing processes. The cost-benefits that may be realized
through such an approach must be offset against the robot performance, and the
ease with which a useful software system can be implemented. We therefore
investigate whether the use of such a system is indeed feasible for
OPTIMOS-EVE, and the possibilities of extending this approach to other
instruments that are currently in the planning stage.