[1]  oai:arXiv.org:0912.3689  [pdf] - 125372
Status of the CRESST Dark Matter Search
Comments: Proceedings of the 13th International Workshop on Low Temperature Detectors, 4 pages, 3 figures
Submitted: 2009-12-18
The CRESST experiment aims for a detection of dark matter in the form of WIMPs. These particles are expected to scatter elastically off the nuclei of a target material, thereby depositing energy on the recoiling nucleus. CRESST uses scintillating CaWO4 crystals as such a target. The energy deposited by an interacting particle is primarily converted to phonons which are detected by transition edge sensors. In addition, a small fraction of the interaction energy is emitted from the crystals in the form of scintillation light which is measured in coincidence with the phonon signal by a separate cryogenic light detector for each target crystal. The ratio of light to phonon energy permits the discrimination between the nuclear recoils expected from WIMPs and events from radioactive backgrounds which primarily lead to electron recoils. CRESST has shown the success of this method in a commissioning run in 2007 and, since then, further investigated possibilities for an even better suppression of backgrounds. Here, we report on a new class of background events observed in the course of this work. The consequences of this observation are discussed and we present the current status of the experiment.
[2]  oai:arXiv.org:0912.0170  [pdf] - 971925
Composite CaWO4 Detectors for the CRESST-II Experiment
Comments: Proceedings of the Thirteenth International Workshop on Low Temperature Detectors 4 pages, 9 figures
Submitted: 2009-12-01
CRESST-II, standing for Cryogenic Rare Events Search with Superconducting Thermometers phase II, is an experiment searching for Dark Matter. In the LNGS facility in Gran Sasso, Italy, a cryogenic detector setup is operated in order to detect WIMPs by elastic scattering off nuclei, generating phononic lattice excitations and scintillation light. The thermometers used in the experiment consist of a tungsten thin-film structure evaporated onto the CaWO4 absorber crystal. The process of evaporation causes a decrease in the scintillation light output. This, together with the need of a big-scale detector production for the upcoming EURECA experiment lead to investigations for producing thermometers on smaller crystals which are glued onto the absorber crystal. In our Run 31 we tested composite detectors for the first time in the Gran Sasso setup. They seem to produce higher light yields as hoped and could provide an additional time based discrimination mechanism for low light yield clamp events.
[3]  oai:arXiv.org:0905.4282  [pdf] - 24648
Electron and Gamma Background in CRESST Detectors
Comments: 7 pages, 12 figures
Submitted: 2009-05-26
The CRESST experiment monitors 300g CaWO_4 crystals as targets for particle interactions in an ultra low background environment. In this paper, we analyze the background spectra that are recorded by three detectors over many weeks of data taking. Understanding these spectra is mandatory if one wants to further reduce the background level, and allows us to cross-check the calibration of the detectors. We identify a variety of sources, such as intrinsic contaminations due to primordial radioisotopes and cosmogenic activation of the target material. In particular, we detect a 3.6keV X-ray line from the decay of 41-Ca with an activity of (26\pm4)\mu Bq, corresponding to a ratio 41-Ca/40-Ca=(2.2\pm0.3)\times10^{-16}.
[4]  oai:arXiv.org:0903.4687  [pdf] - 22801
Discrimination of Recoil Backgrounds in Scintillating Calorimeters
Comments: 5 pages, 9 figures
Submitted: 2009-03-26
The alpha decay of $\n{{}^{210}Po}$ is a dangerous background to rare event searches. Here, we describe observations related to this alpha decay in the Cryogenic Rare Event Search with Superconducting Thermometers (CRESST). We find that lead nuclei show a scintillation light yield in our $\n{CaWO_4}$ crystals of $0.0142\pm0.0013$ relative to electrons of the same energy. We describe a way to discriminate this source of nuclear recoil background by means of a scintillating foil, and demonstrate its effectiveness. This leads to an observable difference in the pulse shape of the light detector, which can be used to tag these events. Differences in pulse shape of the phonon detector between lead and electron recoils are also extracted, opening the window to future additional background suppression techniques based on pulse shape discrimination in such experiments.
[5]  oai:arXiv.org:0809.1829  [pdf] - 16181
Commissioning Run of the CRESST-II Dark Matter Search
Comments: 10 pages, 9 figs No essential changes in content. Minor errors corrected. Sentence added at end of introduction concerning increased sensitivity. Best limit on plots at M=50 GeV. Text labelling of candidate events corrected
Submitted: 2008-09-10, last modified: 2009-02-16
The CRESST cryogenic direct dark matter search at Gran Sasso, searching for WIMPs via nuclear recoil, has been upgraded to CRESST-II by several changes and improvements.We present the results of a commissioning run carried out in 2007. The basic element of CRESST-II is a detector module consisting of a large (~ 300 g) CaWO_4 crystal and a very sensitive smaller (~ 2 g) light detector to detect the scintillation light from the CaWO_4.Information from light-quenching factor studies allows the definition of a region of the energy-light yield plane which corresponds to tungsten recoils. A neutron test is reported which supports the principle of using the light yield to identify the recoiling nucleus. Data obtained with two detector modules for a total exposure of 48 kg-days are presented. Judging by the rate of events in the "all nuclear recoils" acceptance region the apparatus shows a factor ~ten improvement with respect to previous results, which we attribute principally to the presence of the neutron shield. In the "tungsten recoils" acceptance region three events are found, corresponding to a rate of 0.063 per kg-day. Standard assumptions on the dark matter flux, coherent or spin independent interactions,then yield a limit for WIMP-nucleon scattering of 4.8 \times 10^{-7}pb, at M{WIMP} ~50 GeV.
[6]  oai:arXiv.org:0810.0423  [pdf] - 17016
Cryogenic Composite Detectors for the Dark Matter Experiments CRESST and EURECA
Comments: 7 pages, 8 figures; To appear in the proceedings of CryoScint08 (http://cryoscint08.in2p3.fr), Univ. Lyon 1, France, June 6th 2008, P. Di Stefano (IPN Lyon) and F. Petricca (MPP Munich) eds
Submitted: 2008-10-02
Weakly Interacting Massive Particles (WIMPs) are candidates for non-baryonic Dark Matter. WIMPs are supposed to interact with baryonic matter via scattering off nuclei producing a nuclear recoil with energies up to a few 10 keV with a very low interaction rate of ~10^(-6) events per kg of target material and day in the energy region of interest. The Dark Matter experiment CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) and the EURECA project (European Underground Rare Event Calorimeter Array) are aimed at the direct detection of WIMPs with the help of very sensitive modularised cryogenic detectors that basically consist of a transition edge sensor (TES) in combination with a massive absorber crystal. In the CRESST experiment the search for coherent WIMP-nucleon scattering events is validated by the detection of two processes. In the scintillating absorber single crystal, CaWO_4, heat (phonons) and scintillation light are produced and detected with two independent cryogenic detectors: a phonon channel and a separate light channel. The development of such cryogenic detectors and the potential ton-scale production are investigated in this paper. To decouple the TES production from the choice of the target material in order to avoid heating cycles of the absorber crystal and to allow pretesting of the TESs, a composite detector design (CDD) for the detector production has been developed and studied. An existing thermal detector model has been extended to the CDD, in order to investigate, understand, and optimize the performance of composite detectors. This extended model, which has been worked out in detail, can be expected to provide a considerable help when tailoring composite detectors to the requirements of various experiments.
[7]  oai:arXiv.org:0810.0132  [pdf] - 16940
Neutron Scattering Facility for Characterization of CRESST and EURECA Detectors at mK Temperatures
Comments: 6 pages, 7 figures, To appear in the proceedings of CryoScint08 (http://cryoscint08.in2p3.fr), Univ. Lyon 1, France, June 6th 2008, P. Di Stefano (IPN Lyon) and F. Petricca (MPP Munich) eds
Submitted: 2008-10-01
CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) is an experiment located at the Gran Sasso underground laboratory and aimed at the direct detection of dark matter in the form of WIMPs. The setup has just completed a one year commissioning run in 2007 and is presently starting a physics run with an increased target mass. Scintillating $\mathrm{CaWO_4}$ single crystals, operated at temperatures of a few millikelvin, are used as target to detect the tiny nuclear recoil induced by a WIMP. The powerful background identification and rejection of $\alpha$, e$^{-}$ and $\gamma$ events is realized via the simultaneous measurement of a phonon and a scintillation signal generated in the $\mathrm{CaWO_4}$ crystal. However, neutrons could still be misidentified as a WIMP signature. Therefore, a detailed understanding of the individual recoil behaviour in terms of phonon generation and scintillation light emission due to scattering on Ca, O or W nuclei, respectively, is mandatory. The only setup which allows to perform such measurements at the operating temperature of the CRESST detectors has been installed at the Maier-Leibnitz-Accelerator Laboratory in Garching and is presently being commissioned. The design of this neutron scattering facility is such that it can also be used for other target materials, e.g. $\mathrm{ZnWO_4}$, $\mathrm{PbWO_4}$ and others as foreseen in the framework of the future multitarget tonne-scale experiment EURECA (European Underground Rare Event Calorimeter Array).
[8]  oai:arXiv.org:astro-ph/0408006  [pdf] - 66497
Limits on WIMP dark matter using scintillating CaWO4 cryogenic detectors with active background suppression
Comments: 24 pages, 10 figures, version v2 includes figures with improved print quality, v3 accepted for publication in astroparticle physics
Submitted: 2004-07-30, last modified: 2005-01-17
We present first significant limits on WIMP dark matter by the phonon-light technique, where combined phonon and light signals from a scintillating cryogenic detector are used. Data from early 2004 with two 300 g CRESST-II prototype detector modules are presented, with a net exposure of 20.5 kg days. The modules consist of a CaWO4 scintillating ``target'' crystal and a smaller cryogenic light detector. The combination of phonon and light signals leads to a strong suppression of non-nuclear recoil backgrounds. Using this information to define an acceptance region for nuclear recoils we have 16 events from the two modules, corresponding to a rate for nuclear recoils between 12 and 40 keV of (0.87 +- 0.22) events/(kg day). This is compatible with the rate expected from neutron background, and most of these events lie in the region of the phonon-light plane anticipated for neutron-induced recoils. A particularly strong limit for WIMPs with coherent scattering results from selecting a region of the phonon-light plane corresponding to tungsten recoils, where the best module shows zero events.
[9]  oai:arXiv.org:astro-ph/0411396  [pdf] - 1507893
The CRESST Dark Matter Search
Comments: 6 pages, 3 figures, to be published in the proceedings of the 5th International Workshop on the Identification and Detection of Dark Matter IDM 2004, Edinburgh, Sept. 2004, World Scientific
Submitted: 2004-11-15
We present first competitive results on WIMP dark matter using the phonon-light-detection technique. A particularly strong limit for WIMPs with coherent scattering results from selecting a region of the phonon-light plane corresponding to tungsten recoils. The observed count rate in the neutron band is compatible with the rate expected from neutron background. CRESST is presently being upgraded with a 66 channel SQUID readout system, a neutron shield and a muon veto system. This results in a significant improvement in sensitivity.