Normalized to: Weller, H.
[1]
oai:arXiv.org:1303.4326 [pdf] - 1165339
Unambiguous Identification of the Second 2+ State in 12C and the
Structure of the Hoyle State
Zimmerman, W. R.;
Ahmed, M. W.;
Bromberger, B.;
Stave, S. C.;
Breskin, A.;
Dangendorf, V.;
Delbar, Th.;
Gai, M.;
Henshaw, S. S.;
Mueller, J. M.;
Sun, C.;
Tittelmeier, K.;
Weller, H. R.;
Wu, Y. K.
Submitted: 2013-03-18
The second 2+ state of 12C, predicted over fifty years ago as an excitation
of the Hoyle state, has been unambiguously identified using the 12C(g,a_0)8Be
reaction. The alpha particles produced by the photodisintegration of 12C were
detected using an Optical Time Projection Chamber (O-TPC). Data were collected
at beam energies between 9.1 and 10.7 MeV using the intense nearly
mono-energetic gamma-ray beams at the HIgS facility. The measured angular
distributions determine the cross section and the E1-E2 relative phases as a
function of energy leading to an unambiguous identification of the second 2+
state in 12C at 10.03(11) MeV, with a total width of 800(130) keV and a ground
state gamma-decay width of 60(10) meV; B(E2: 2+ ---> gs) = 0.73(13) e2fm4 [or
0.45(8) W.u.]. The Hoyle state and its rotational 2+ state that are more
extended than the ground state of 12C presents a challenge and constraints for
models attempting to reveal the nature of three alpha particle states in 12C.
Specifically it challenges the ab-initio Lattice Effective Field Theory (L-EFT)
calculations that predict similar r.m.s. radii for the ground state and the
Hoyle state.
[2]
oai:arXiv.org:1101.1940 [pdf] - 288646
An Optical Readout TPC (O-TPC) for Studies in Nuclear Astrophysics With
Gamma-Ray Beams at HIgS
Gai, M.;
Ahmed, M. W.;
Stave, S. C.;
Zimmerman, W. R.;
Breskin, A.;
Bromberger, B.;
Chechik, R.;
Dangendorf, V.;
Delbar, Th.;
France, R. H.;
Henshaw, S. S.;
Kading, T. J.;
Martel, P. P.;
McDonald, J. E. R.;
Seo, P. -N.;
Tittelmeier, K.;
Weller, H. R.;
Young, A. H.
Submitted: 2011-01-10
We report on the construction, tests, calibrations and commissioning of an
Optical Readout Time Projection Chamber (O-TPC) detector operating with a
CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure
the cross sections of several key nuclear reactions involved in stellar
evolution. In particular, a study of the rate of formation of oxygen and carbon
during the process of helium burning will be performed by exposing the chamber
gas to intense nearly mono-energetic gamma-ray beams at the High Intensity
Gamma Source (HIgS) facility. The O-TPC has a sensitive target-drift volume of
30x30x21 cm^3. Ionization electrons drift towards a double parallel grid
avalanche multiplier, yielding charge multiplication and light emission.
Avalanche induced photons from N2 emission are collected, intensified and
recorded with a Charge Coupled Device (CCD) camera, providing two-dimensional
track images. The event's time projection (third coordinate) and the deposited
energy are recorded by photomultipliers and by the TPC charge-signal,
respectively. A dedicated VME-based data acquisition system and associated data
analysis tools were developed to record and analyze these data. The O-TPC has
been tested and calibrated with 3.183 MeV alpha-particles emitted by a 148Gd
source placed within its volume with a measured energy resolution of 3.0%.
Tracks of alpha and 12C particles from the dissociation of 16O and of three
alpha-particles from the dissociation of 12C have been measured during initial
in-beam test experiments performed at the HIgS facility at Duke University. The
full detection system and its performance are described and the results of the
preliminary in-beam test experiments are reported.
[3]
oai:arXiv.org:nucl-ex/0608027 [pdf] - 118485
In Beam Tests of Implanted Helium Targets
McDonald, J. E.;
France, R. H.;
Jarvis, R. A.;
Ahmed, M. W.;
Blackston, M. A.;
Delbar, Th.;
Gai, M.;
Kading, T. J.;
Parpottas, Y.;
Perdue, B. A.;
Prior, R. M.;
Rubin, D. A.;
Spraker, M. C.;
Yeomans, J. D.;
Weissman, L.;
Weller, H. R.;
Wilds, E. L.;
;
;
UHartford;
GCSU;
LNS/UConn;
TUNL/Duke;
UCL/LLN;
Yale;
NGCSU
Submitted: 2006-08-16
Targets consisting of 3,4He implanted into thin aluminum foils (approximately
100, 200 or 600 ug/cm^2) were prepared using intense (a few uA) helium beams at
low energy (approximately 20, 40 or 100 keV). Uniformity of the implantation
was achieved by a beam raster across a 12 mm diameter tantalum collimator at
the rates of 0.1 Hz in the vertical direction and 1 Hz in the horizontal
direction. Helium implantation into the very thin (approximately 80-100
ug/cm^2) aluminum foils failed to produce useful targets (with only
approximately 10% of the helium retained) due to an under estimation of the
range by the code SRIM. The range of low energy helium in aluminum predicted by
Northcliffe and Shilling and the NIST online tabulation are observed on the
other hand to over estimate the range of low energy helium ions in aluminum. An
attempt to increase the amount of helium by implanting a second deeper layer
was also carried out, but it did not significantly increase the helium content
beyond the blistering limit (approximately 6 x 10^17 helium/cm^2). The
implanted targets were bombarded with moderately intense 4He and 16O beams of
50-100 particle nA . Rutherford Back Scattering of 1.0 and 2.5 MeV proton beams
and recoil helium from 15.0 MeV oxygen beams were used to study the helium
content and profile before, during and after bombardments. We observed the
helium content and profile to be very stable even after a prolonged bombardment
(up to two days) with moderately intense beams of 16O or 4He. Helium implanted
into thin (aluminum) foils is a good choice for thin helium targets needed, for
example, for a measurement of the 3he(a,g)7Be reaction and the associated S34
astrophysical cross section factor (S-factor).
[4]
oai:arXiv.org:physics/0602188 [pdf] - 119148
Amplification and Scintillation Properties of Oxygen-Rich Gas Mixtures
for Optical-TPC Applications
Submitted: 2006-02-27, last modified: 2006-05-27
We studied electron amplification and light emission from avalanches in
oxygen-containing gas mixtures. The mixtures investigated in this work
included, among others, CO2 and N2O mixed with Triethylamine (TEA) or N2.
Double-Step Parallel Gap (DSPG) multipliers and THick Gas Electron Multipliers
(THGEM) were investigated. High light yields were measured from CO2+N2 and
CO2+TEA, though with different emission spectra. We observed the characteristic
wave-length emission of N2 and of TEA and used a polymer wave-length shifter to
convert TEA UV-light into the visible spectrum. The results of these
measurements indicate the applicability of optical recording of ionizing tracks
in a TPC target-detector designed to study the cross section of the 16O(g,a)12C
reaction, a central problem in nuclear astrophysics.
[5]
oai:arXiv.org:nucl-ex/0504003 [pdf] - 118469
Optical Readout Time Projection Chamber (O-TPC) for a Study of Oxygen
Formation In Stellar Helium Burning
Submitted: 2005-04-01
We are developing an Optical Readout Time Projection Chamber (O-TPC) detector
for the study of the 12C(a,g)16O reaction that determines the ratio of carbon
to oxygen in helium burning. This ratio is crucial for understanding the final
fate of a progenitor star and the nucleosynthesis of elements prior to a Type
II supernova; an oxygen rich star is predicted to collapse to a black hole, and
a carbon rich star to a neutron star. Type Ia supernovae (SNeIa) are used as
standard candles for measuring cosmological distances with the use of an
empirical light curve-luminosity stretching factor. It is essential to
understand helium burning that yields the carbon/oxygen white dwarf and thus
the initial stage of SNeIa. The O-TPC is intended for use with high intensity
photon beams extracted from the HIgS/TUNL facility at Duke University to study
the 16O(g,a)12C reaction, and thus the direct reaction at energies as low as
0.7 MeV. We are conducting a systematical study of the best oxygen containing
gas with light emitting admixture(s) for use in such an O-TPC. Preliminary
results with CO_2 + TEA mixture were obtained