Normalized to: Weinheimer., C.
[1]
oai:arXiv.org:1406.2374 [pdf] - 940307
Conceptual design and simulation of a water Cherenkov muon veto for the
XENON1T experiment
Aprile, E.;
Agostini, F.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Auger, M.;
Balan, C.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Breskin, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Lellouch, D.;
Levinson, L.;
Levy, C.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Lyashenko, A.;
MacMullin, S.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Paras, D. Mayani;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Miguez, B.;
Molinario, A.;
Morana, G.;
Murra, M.;
Naganoma, J.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer., C.
Submitted: 2014-06-09, last modified: 2015-02-25
XENON is a dark matter direct detection project, consisting of a time
projection chamber (TPC) filled with liquid xenon as detection medium. The
construction of the next generation detector, XENON1T, is presently taking
place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a
sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~
\mathrm{cm}^{\mathrm{2}}$ for WIMP masses around 50 GeV/c$^{2}$, which requires
a background reduction by two orders of magnitude compared to XENON100, the
current generation detector. An active system that is able to tag muons and
muon-induced backgrounds is critical for this goal. A water Cherenkov detector
of $\sim$10 m height and diameter has been therefore developed, equipped with 8
inch photomultipliers and cladded by a reflective foil. We present the design
and optimization study for this detector, which has been carried out with a
series of Monte Carlo simulations. The muon veto will reach very high detection
efficiencies for muons ($>99.5%$) and showers of secondary particles from muon
interactions in the rock ($>70%$). Similar efficiencies will be obtained for
XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity
by another order of magnitude. With the Cherenkov water shield studied here,
the background from muon-induced neutrons in XENON1T is negligible.