Normalized to: Weima, E.
[1]
oai:arXiv.org:1905.12522 [pdf] - 1995410
Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$
Bubble Chambers
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chen, S.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Coutu, C. B.;
Cowles, C.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Filgas, R.;
Fuentes, J.;
Girard, F.;
Giroux, G.;
Hackett, B.;
Hagen, A.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hillier, T.;
Hoppe, E. W.;
Jackson, C. M.;
Jin, M.;
Klopfenstein, L.;
Kozynets, T.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Licciardi, C.;
Lippincott, W. H.;
Loer, B.;
Mamedov, F.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Pal, S.;
Piro, M. -C.;
Plante, A.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Tiwari, D.;
Vázquez-Jáuregui, E.;
Wagner, J. M.;
Walkowski, N.;
Weima, E.;
Wichoski, U.;
Wierman, K.;
Woodley, W.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-05-29, last modified: 2019-11-06
The primary advantage of moderately superheated bubble chamber detectors is
their simultaneous sensitivity to nuclear recoils from WIMP dark matter and
insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO
gamma calibration data demonstrates for the first time that electron recoils in
C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one
driven by a hot-spike as previously supposed. Using this semi-empirical model,
bubble chamber nucleation thresholds may be tuned to be sensitive to lower
energy nuclear recoils while maintaining excellent electron recoil rejection.
The PICO-40L detector will exploit this model to achieve thermodynamic
thresholds as low as 2.8 keV while being dominated by single-scatter events
from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one
year of operation, PICO-40L can improve existing leading limits from PICO on
spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP
masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all
existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP
masses from 3 to 40 GeV c$^{-2}$.
[2]
oai:arXiv.org:1902.04031 [pdf] - 1916812
Dark Matter Search Results from the Complete Exposure of the PICO-60
C$_3$F$_8$ Bubble Chamber
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Coutu, C. B.;
Cowles, C.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hillier, T.;
Hoppe, E. W.;
Jackson, C. M.;
Jin, M.;
Klopfenstein, L.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Licciardi, C.;
Lippincott, W. H.;
Loer, B.;
Mamedov, F.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Piro, M. -C.;
Plante, A.;
Podviyanuk, R.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Vázquez-Jáuregui, E.;
Walkowski, N.;
Weima, E.;
Wichoski, U.;
Wierman, K.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-02-11
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark
matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in
the SNOLAB underground laboratory. The chamber was operated at thermodynamic
thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day
exposure at 2.45 keV threshold was acquired with approximately the same
expected total background rate as the previous 1167-kg-day exposure at 3.3 keV.
This increased exposure is enabled in part by a new optical tracking analysis
to better identify events near detector walls, permitting a larger fiducial
volume. These results set the most stringent direct-detection constraint to
date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$
cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV
WIMPs by an order of magnitude.