sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Wei, Ray-Ming

Normalized to: Wei, R.

3 article(s) in total. 67 co-authors, from 1 to 4 common article(s). Median position in authors list is 18,0.

[1]  oai:arXiv.org:2005.07864  [pdf] - 2096493
The backbone-residual model. Accurately characterising the instrumental profile of a fibre-fed echelle spectrograph
Comments: 15 pages, 14 figures. Submitted to A&A
Submitted: 2020-05-16
Context: Instrumental profile (IP) is the basic property of a spectrograph. Accurate IP characterisation is the prerequisite of accurate wavelength solution. It also facilitates new spectral acquisition methods such as the forward modeling and deconvolution. Aims: We investigate an IP modeling method for the fibre-fed echelle spectrograph with the emission lines of the ThAr lamp, and explore the method to evaluate the accuracy of IP characterisation. Methods: The backbone-residual (BR) model is put forward and tested on the fibre-fed High Resolution Spectrograph (HRS) at the Chinese Xinglong 2.16-m Telescope, which is the sum of the backbone function and the residual function. The backbone function is a bell-shaped function to describe the main component and the spatial variation of IP. The residual function, which is expressed as the cubic spline function, accounts for the difference between the bell-shaped function and the actual IP. The method of evaluating the accuracy of IP characterisation is based on the spectral reconstruction and Monte Carlo simulation. Results: The IP of HRS is characterised with the BR model, and the accuracy of the characterised IP reaches 0.006 of the peak value of the backbone function. This result demonstrates that the accurate IP characterisation has been achieved on HRS with the BR model, and the BR model is an excellent choice for accurate IP characterisation of fibre-fed echelle spectrographs.
[2]  oai:arXiv.org:1003.3347  [pdf] - 1025758
AMiBA Wideband Analog Correlator
Comments: 28 pages, 23 figures, ApJ in press.
Submitted: 2010-03-17
A wideband analog correlator has been constructed for the Yuan-Tseh Lee Array for Microwave Background Anisotropy. Lag correlators using analog multipliers provide large bandwidth and moderate frequency resolution. Broadband IF distribution, backend signal processing and control are described. Operating conditions for optimum sensitivity and linearity are discussed. From observations, a large effective bandwidth of around 10 GHz has been shown to provide sufficient sensitivity for detecting cosmic microwave background variations.
[3]  oai:arXiv.org:0810.1871  [pdf] - 900442
The Yuan-Tseh Lee Array for Microwave Background Anisotropy
Comments: accepted for publication in ApJ (13 pages, 7 figures); a version with high resolution figures available at http://www.asiaa.sinica.edu.tw/~keiichi/upfiles/AMiBA7/pho_highreso.pdf
Submitted: 2008-10-10, last modified: 2009-01-03
The Yuan-Tseh Lee Array for Microwave Background Anisotropy (AMiBA) is the first interferometer dedicated to studying the cosmic microwave background (CMB) radiation at 3mm wavelength. The choice of 3mm was made to minimize the contributions from foreground synchrotron radiation and Galactic dust emission. The initial configuration of seven 0.6m telescopes mounted on a 6-m hexapod platform was dedicated in October 2006 on Mauna Loa, Hawaii. Scientific operations began with the detection of a number of clusters of galaxies via the thermal Sunyaev-Zel'dovich effect. We compare our data with Subaru weak lensing data in order to study the structure of dark matter. We also compare our data with X-ray data in order to derive the Hubble constant.