Normalized to: Warmbier, E.
[1]
oai:arXiv.org:1909.04541 [pdf] - 1958366
The Keck Planet Imager and Characterizer: Demonstrating advanced
exoplanet characterization techniques for future extremely large telescopes
Jovanovic, N.;
Delorme, J. R.;
Bond, C. Z.;
Cetre, S.;
Mawet, D.;
Echeverri, D.;
Wallace, J. K.;
Bartos, R.;
Lilley, S.;
Ragland, S.;
Ruane, G.;
Wizinowich, P.;
Chun, M.;
Wang, J.;
Wang, J.;
Fitzgerald, M.;
Matthews, K.;
Pezzato, J.;
Calvin, B.;
Millar-Blanchaer, M.;
Martin, E. C.;
Wetherell, E.;
Wang, E.;
Jacobson, S.;
Warmbier, E.;
Lockhart, C.;
Hall, D.;
Jensen-Clem, R.;
McEwen, E.
Submitted: 2019-09-10
The Keck Planet Imager and Characterizer (KPIC) is an upgrade to the Keck II
adaptive optics system enabling high contrast imaging and high-resolution
spectroscopic characterization of giant exoplanets in the mid-infrared (2-5
microns). The KPIC instrument will be developed in phases. Phase I entails the
installation of an infrared pyramid wavefront sensor (PyWFS) based on a fast,
low-noise SAPHIRA IR-APD array. The ultra-sensitive infrared PyWFS will enable
high contrast studies of infant exoplanets around cool, red, and/or obscured
targets in star forming regions. In addition, the light downstream of the PyWFS
will be coupled into an array of single-mode fibers with the aid of an active
fiber injection unit (FIU). In turn, these fibers route light to Keck's
high-resolution infrared spectrograph NIRSPEC, so that high dispersion
coronagraphy (HDC) can be implemented for the first time. HDC optimally pairs
high contrast imaging and high-resolution spectroscopy allowing detailed
characterization of exoplanet atmospheres, including molecular composition,
spin measurements, and Doppler imaging.
Here we provide an overview of the instrument, its science scope, and report
on recent results from on-sky commissioning of Phase I. The instrument design
and techniques developed will be key for more advanced instrument concepts
needed for the extremely large telescopes of the future.
[2]
oai:arXiv.org:1807.05291 [pdf] - 1722494
LASSO: Large Adaptive optics Survey for Substellar Objects using the new
SAPHIRA detector on Robo-AO
Salama, Maissa;
Ou, James;
Baranec, Christoph;
Liu, Michael C.;
Bowler, Brendan P.;
Riddle, Reed;
Duev, Dmitry;
Hall, Donald;
Atkinson, Dani;
Goebel, Sean;
Chun, Mark;
Jacobson, Shane;
Lockhart, Charles;
Warmbier, Eric;
Kulkarni, Shrinivas;
Law, Nicholas M.
Submitted: 2018-07-13, last modified: 2018-07-24
We report on initial results from the largest infrared AO direct imaging
survey searching for wide orbit (>100 AU) massive exoplanets and brown dwarfs
as companions around young nearby stars using Robo-AO at the 2.1-m telescope on
Kitt Peak, Arizona. The occurrence rates of these rare substellar companions
are critical to furthering our understanding of the origin of planetary-mass
companions on wide orbits. The observing efficiency of Robo-AO allows us to
conduct a survey an order of magnitude larger than previously possible. We
commissioned a low-noise high-speed SAPHIRA near-infrared camera to conduct
this survey and report on its sensitivity, performance, and data reduction
process.
[3]
oai:arXiv.org:1805.08419 [pdf] - 1720229
Overview of the SAPHIRA Detector for AO Applications
Submitted: 2018-05-22, last modified: 2018-05-23
We discuss some of the unique details of the operation and behavior of
Leonardo SAPHIRA detectors, particularly in relation to their usage for
adaptive optics wavefront sensing. SAPHIRA detectors are 320$\times$256@24
$\mu$m pixel HgCdTe linear avalanche photodiode arrays and are sensitive to
0.8-2.5 $\mu m$ light. SAPHIRA arrays permit global or line-by-line resets, of
the entire detector or just subarrays of it, and the order in which pixels are
reset and read enable several readout schemes. We discuss three readout modes,
the benefits, drawbacks, and noise sources of each, and the observational modes
for which each is optimal. We describe the ability of the detector to read
subarrays for increased frame rates, and finally clarify the differences
between the avalanche gain (which is user-adjustable) and the charge gain
(which is not).