sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Walter, A. B.

Normalized to: Walter, A.

14 article(s) in total. 97 co-authors, from 1 to 14 common article(s). Median position in authors list is 7,0.

[1]  oai:arXiv.org:2007.06496  [pdf] - 2132084
Flexible Coaxial Ribbon Cable for High-Density Superconducting Microwave Device Arrays
Comments: in IEEE Transactions on Applied Superconductivity
Submitted: 2020-07-13
Superconducting electronics often require high-density microwave interconnects capable of transporting signals between temperature stages with minimal loss, cross talk, and heat conduction. We report the design and fabrication of superconducting 53 wt% Nb-47 wt% Ti (Nb47Ti) FLexible coAXial ribbon cables (FLAX). The ten traces each consist of a 0.076 mm O.D. NbTi inner conductor insulated with PFA (0.28 mm O.D.) and sheathed in a shared 0.025 mm thick Nb47Ti outer conductor. The cable is terminated with G3PO coaxial push-on connectors via stainless steel capillary tubing (1.6 mm O.D., 0.13 mm thick) soldered to a coplanar wave guide transition board. The 30 cm long cable has 1 dB of loss at 8 GHz with -60 dB nearest-neighbor forward cross talk. The loss is 0.5 dB more than commercially available superconducting coax likely due to impedance mismatches caused by manufacturing imperfections in the cable. The reported cross talk is 30 dB lower than previously developed laminated NbTi-onKapton microstrip cables. We estimate the heat load from 1 K to 90 mK to be 20 nW per trace, approximately half the computed load from the smallest commercially available superconducting coax from CryoCoax
[2]  oai:arXiv.org:1911.06434  [pdf] - 2002490
Design and Performance of Hafnium Optical and Near-IR Kinetic Inductance Detectors
Comments:
Submitted: 2019-11-14
We report on the design and performance of Microwave Kinetic Inductance Detectors (MKIDs) sensitive to single photons in the optical to near-infrared range using hafnium as the sensor material. Our test device had a superconducting transition temperature of 395 mK and a room temperature normal state resistivity of 97 $\mu \Omega$ cm with an RRR = 1.6. Resonators on the device displayed internal quality factors of around 200,000. Similar to the analysis of MKIDs made from other highly resistive superconductors, we find that modeling the temperature response of the detector requires an extra broadening parameter in the superconducting density of states. Finally, we show that this material and design is compatible with a full-array fabrication process which resulted in pixels with decay times of about 40 $\mu$s and resolving powers of ~9 at 800 nm.
[3]  oai:arXiv.org:1908.02775  [pdf] - 1931524
Optical and Near-IR Microwave Kinetic Inductance Detectors (MKIDs) in the 2020s
Comments: Astro2020 APC Whitepaper. 16 pages, 10 figures
Submitted: 2019-08-07
Optical and near-IR Microwave Kinetic Inductance Detectors, or MKIDs, are superconducting photon counting detectors capable of measuring the energy and arrival time of individual OIR photons without read noise or dark current. In this whitepaper we will discuss the current status of OIR MKIDs and MKID-based instruments.
[4]  oai:arXiv.org:1906.03354  [pdf] - 1975296
Stochastic Speckle Discrimination with Time-Tagged Photon Lists: Digging Below the Speckle Noise Floor
Comments:
Submitted: 2019-06-07
We present an algorithm that uses the distribution of photon arrival times to distinguish speckles from incoherent sources, like planets and disks, in high contrast images. Using simulated data, we show that our approach can overcome the noise limit from fluctuating speckle intensity. The algorithm is likely to be most advantageous when a coronagraph limits the coherent diffraction pattern in the image plane but the intensity is still strongly modulated by fast-timescale uncorrected stellar light, for example from atmospheric turbulence. These conditions are common at small inner working angles and will allow probing of exoplanet populations at smaller angular separations. The technique requires a fast science camera that can temporally resolve the speckle fluctuations, and the detection of many photons per speckle decorrelation time. Since the algorithm directly extracts the incoherent light, standard differential imaging post-processing techniques can be performed afterwards to further boost the signal.
[5]  oai:arXiv.org:1809.08301  [pdf] - 1755190
SCExAO, an instrument with a dual purpose: perform cutting-edge science and develop new technologies
Comments: 12 pages, 9 figures, conference proceedings (SPIE Astronomical telescopes and instrumentation 2018)
Submitted: 2018-09-21
The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument is an extremely modular high-contrast instrument installed on the Subaru telescope in Hawaii. SCExAO has a dual purpose. Its position in the northern hemisphere on a 8-meter telescope makes it a prime instrument for the detection and characterization of exoplanets and stellar environments over a large portion of the sky. In addition, SCExAO's unique design makes it the ideal instrument to test innovative technologies and algorithms quickly in a laboratory setup and subsequently deploy them on-sky. SCExAO benefits from a first stage of wavefront correction with the facility adaptive optics AO188, and splits the 600-2400 nm spectrum towards a variety of modules, in visible and near infrared, optimized for a large range of science cases. The integral field spectrograph CHARIS, with its J, H or K-band high-resolution mode or its broadband low-resolution mode, makes SCExAO a prime instrument for exoplanet detection and characterization. Here we report on the recent developments and scientific results of the SCExAO instrument. Recent upgrades were performed on a number of modules, like the visible polarimetric module VAMPIRES, the high-performance infrared coronagraphs, various wavefront control algorithms, as well as the real-time controller of AO188. The newest addition is the 20k-pixel Microwave Kinetic Inductance Detector (MKIDS) Exoplanet Camera (MEC) that will allow for previously unexplored science and technology developments. MEC, coupled with novel photon-counting speckle control, brings SCExAO closer to the final design of future high-contrast instruments optimized for Giant Segmented Mirror Telescopes (GSMTs).
[6]  oai:arXiv.org:1803.10420  [pdf] - 1666883
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field Spectrograph for High-Contrast Astronomy
Comments: 17 pages, 17 figures. PASP Published
Submitted: 2018-03-28, last modified: 2018-04-16
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving Superconducting Spectrophotometer), the first of several planned integral field spectrographs to use optical/near-infrared Microwave Kinetic Inductance Detectors (MKIDs) for high-contrast imaging. The photon counting and simultaneous low-resolution spectroscopy provided by MKIDs will enable real-time speckle control techniques and post-processing speckle suppression at framerates capable of resolving the atmospheric speckles that currently limit high-contrast imaging from the ground. DARKNESS is now operational behind the PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at Palomar Observatory. Here we describe the motivation, design, and characterization of the instrument, early on-sky results, and future prospects.
[7]  oai:arXiv.org:1712.08584  [pdf] - 1607148
Pioneering high contrast science instruments for planet characterization on giant segmented mirror telescopes
Comments: 11 pages, 3 figures, AO4ELTs4 conference
Submitted: 2017-12-22
A suite of science instruments is critical to any high contrast imaging facility, as it defines the science capabilities and observing modes available. SCExAO uses a modular approach which allows for state-of-the-art visitor modules to be tested within an observatory environment on an 8-m class telescope. This allows for rapid prototyping of new and innovative imaging techniques that otherwise take much longer in traditional instrument design. With the aim of maturing science modules for an advanced high contrast imager on an giant segmented mirror telescopes (GSMTs) that will be capable of imaging terrestrial planets, we offer an overview and status update on the various science modules currently under test within the SCExAO instrument.
[8]  oai:arXiv.org:1710.07318  [pdf] - 1590047
Large-format platinum silicide microwave kinetic inductance detectors for optical to near-IR astronomy
Comments: 16 pages, 8 figures, published in Optics Express
Submitted: 2017-10-19
We have fabricated and characterized 10,000 and 20,440 pixel Microwave Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive optics systems with the goal of directly imaging exoplanets in a 800-1400 nm band. Previous large optical and near-IR MKID arrays were fabricated using substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays, however, suffered from severe non-uniformities in the TiN critical temperature, causing resonances to shift away from their designed values and lowering usable detector yield. We have begun fabricating DARKNESS and MEC arrays using platinum silicide (PtSi) on sapphire instead of TiN. Not only do these arrays have much higher uniformity than the TiN arrays, resulting in higher pixel yields, they have demonstrated better spectral resolution than TiN MKIDs of similar design. PtSi MKIDs also do not display the hot pixel effects seen when illuminating TiN on silicon MKIDs with photons with wavelengths shorter than 1 um.
[9]  oai:arXiv.org:1610.00725  [pdf] - 1496313
High Quality Factor Platinum Silicide Microwave Kinetic Inductance Detectors
Comments: 5 pages, 5 figures, accepted by APL
Submitted: 2016-10-03
We report on the development of Microwave Kinetic Inductance Detectors (MKIDs) using platinum silicide as the sensor material. MKIDs are an emerging superconducting detector technology, capable of measuring the arrival times of single photons to better than two microseconds and their energies to around ten percent. Previously, MKIDs have been fabricated using either sub-stoichiometric titanium nitride or aluminum, but TiN suffers from spatial inhomogeneities in the superconducting critical temperature and Al has a low kinetic inductance fraction, causing low detector sensitivity. To address these issues, we have instead fabricated PtSi microresonators with superconducting critical temperatures of 944$\pm$12~mK and high internal quality factors ($Q_i \gtrsim 10^6$). These devices show typical quasiparticle lifetimes of $\tau_{qp} \approx 30$--$40~\mu$s and spectral resolution, $R = \lambda / \Delta \lambda$, of 8 at 406.6~nm. We compare PtSi MKIDs to those fabricated with TiN and detail the substantial advantages that PtSi MKIDs have to offer.
[10]  oai:arXiv.org:1603.05270  [pdf] - 1385546
Search for Optical Pulsations in PSR J0337+1715
Comments: 4 pages, 2 figures, accepted to MNRAS
Submitted: 2016-03-16
We report on a search for optical pulsations from PSR J0337+1715 at its observed radio pulse period. PSR J0337+1715 is a millisecond pulsar (2.7 ms spin period) in a triple hierarchical system with two white dwarfs, and has a known optical counterpart with g-band magnitude 18. The observations were done with the Array Camera for Optical to Near-IR Spectrophotometry (ARCONS) at the 200" Hale telescope at Palomar Observatory. No significant pulsations were found in the range 4000-11000 angstroms, and we can limit pulsed emission in g-band to be fainter than 25 mag.
[11]  oai:arXiv.org:1507.05631  [pdf] - 1259174
The ARCONS Pipeline: Data Reduction for MKID Arrays
Comments: 16 pages, 19 figures, pdflatex, accepted for ApJS
Submitted: 2015-07-20
The Array Camera for Optical to Near-IR Spectrophotometry, or ARCONS, is a camera based on Microwave Kinetic Inductance Detectors (MKIDs), a new technology that has the potential for broad application in astronomy. Using an array of MKIDs, the instrument is able to produce time-resolved imaging and low-resolution spectroscopy constructed from detections of individual photons. The arrival time and energy of each photon are recorded in a manner similar to X-ray calorimetry, but at higher photon fluxes. The technique works over a very large wavelength range, is free from fundamental read noise and dark-current limitations, and provides microsecond-level timing resolution. Since the instrument reads out all pixels continuously while exposing, there is no loss of active exposure time to readout. The technology requires a different approach to data reduction compared to conventional CCDs. We outline here the prototype data reduction pipeline developed for ARCONS, though many of the principles are also more broadly applicable to energy-resolved photon counting arrays (e.g., transition edge sensors, superconducting tunnel junctions). We describe the pipeline's current status, and the algorithms and techniques employed in taking data from the arrival of photons at the MKID array to the production of images, spectra, and time-resolved light curves.
[12]  oai:arXiv.org:1506.07537  [pdf] - 1237882
Highly Multiplexible Thermal Kinetic Inductance Detectors for X-Ray Imaging Spectroscopy
Comments: 7 pages, 4 figures, accepted for publication in Applied Physics Letters
Submitted: 2015-06-24
For X-ray imaging spectroscopy, high spatial resolution over a large field of view is often as important as high energy resolution, but current X-ray detectors do not provide both in the same device. Thermal Kinetic Inductance Detectors (TKIDs) are being developed as they offer a feasible way to combine the energy resolution of transition edge sensors with pixel counts approaching CCDs and thus promise significant improvements for many X-ray spectroscopy applications. TKIDs are a variation of Microwave Kinetic Inductance Detectors (MKIDs) and share their multiplexibility: working MKID arrays with 2024 pixels have recently been demonstrated and much bigger arrays are under development. In this work, we present our first working TKID prototypes which are able to achieve an energy resolution of 75 eV at 5.9 keV, even though their general design still has to be optimized. We further describe TKID fabrication, characterization, multiplexing and working principle and demonstrate the necessity of a data fitting algorithm in order to extract photon energies. With further design optimizations we expect to be able to improve our TKID energy resolution to less than 10 eV at 5.9 keV.
[13]  oai:arXiv.org:1309.3270  [pdf] - 785198
Excess Optical Enhancement Observed with ARCONS for Early Crab Giant Pulses
Comments: 5 pages, 5 figures. Updated to match revised version, accepted to ApJL Nov 7, 2013. Several additions and improved DM in timing solution
Submitted: 2013-09-12, last modified: 2013-11-08
We observe an extraordinary link in the Crab pulsar between the enhancement of an optical pulse and the timing of the corresponding giant radio pulse. At optical through infrared wavelengths, our observations use the high time resolution of ARCONS, a unique superconducting energy-resolving photon-counting array at the Palomar 200-inch telescope. At radio wavelengths, we observe with the Robert C. Byrd Green Bank Telescope and the GUPPI backend. We see an $11.3\pm2.5\%$ increase in peak optical flux for pulses that have an accompanying giant radio pulse arriving near the peak of the optical main pulse, in contrast to a $3.2\pm0.5\%$ increase when an accompanying giant radio pulse arrives soon after the optical peak. We also observe that the peak of the optical main pulse is $2.8\pm0.8\%$ enhanced when there is a giant radio pulse accompanying the optical interpulse. We observe no statistically significant spectral differences between optical pulses accompanied by and not accompanied by giant radio pulses. Our results extend previous observations of optical-radio correlation to the time and spectral domains. Our refined temporal correlation suggests that optical and radio emission are indeed causally linked, and the lack of spectral differences suggests that the same mechanism is responsible for all optical emission.
[14]  oai:arXiv.org:1309.4087  [pdf] - 785202
Direct Detection of SDSS J0926+3624 Orbital Expansion with ARCONS
Comments: 8 pages, 7 figures, submitted to MNRAS
Submitted: 2013-09-16
AM Canum Venaticorum (AM CVn) stars belong to a class of ultra-compact, short period binaries with spectra dominated largely by helium. SDSS J0926+3624 is of particular interest as it is the first observed eclipsing AM CVn system. We observed SDSS J0926+3624 with the \textbf{Ar}ray \textbf{C}amera for \textbf{O}ptical to \textbf{N}ear-IR \textbf{S}pectrophotometry (ARCONS) at the Palomar 200" telescope. ARCONS uses a relatively new type of energy-resolved photon counters called Microwave Kinetic Inductance Detectors (MKIDs). ARCONS, sensitive to radiation from 350 to 1100 nm, has a time resolution of several microseconds and can measure the energy of a photon to $\sim10%$. We present the light curves for these observations and examine changes in orbital period from prior observations. Using a quadratic ephemeris model, we measure a period rate of change $\dot{P} = (3.07 \pm 0.56)\times 10^{-13}$. In addition, we use the high timing resolution of ARCONS to examine the system's high frequency variations and search for possible quasi-periodic oscillations (QPOs). Finally, we use the instrument's spectral resolution to examine the light curves in various wavelength bands. We do not find any high frequency QPOs or significant spectral variability throughout an eclipse.