Normalized to: Walter, A.
[1]
oai:arXiv.org:2007.06496 [pdf] - 2132084
Flexible Coaxial Ribbon Cable for High-Density Superconducting Microwave
Device Arrays
Smith, Jennifer Pearl;
Mazin, Benjamin A.;
Walter, Alex B.;
Daal, Miguel;
Bailey,, J. I.;
Bockstiegel, Clinton;
Zobrist, Nicholas;
Swimmer, Noah;
Steiger, Sarah;
Fruitwala, Neelay
Submitted: 2020-07-13
Superconducting electronics often require high-density microwave
interconnects capable of transporting signals between temperature stages with
minimal loss, cross talk, and heat conduction. We report the design and
fabrication of superconducting 53 wt% Nb-47 wt% Ti (Nb47Ti) FLexible coAXial
ribbon cables (FLAX). The ten traces each consist of a 0.076 mm O.D. NbTi inner
conductor insulated with PFA (0.28 mm O.D.) and sheathed in a shared 0.025 mm
thick Nb47Ti outer conductor. The cable is terminated with G3PO coaxial push-on
connectors via stainless steel capillary tubing (1.6 mm O.D., 0.13 mm thick)
soldered to a coplanar wave guide transition board. The 30 cm long cable has 1
dB of loss at 8 GHz with -60 dB nearest-neighbor forward cross talk. The loss
is 0.5 dB more than commercially available superconducting coax likely due to
impedance mismatches caused by manufacturing imperfections in the cable. The
reported cross talk is 30 dB lower than previously developed laminated
NbTi-onKapton microstrip cables. We estimate the heat load from 1 K to 90 mK to
be 20 nW per trace, approximately half the computed load from the smallest
commercially available superconducting coax from CryoCoax
[2]
oai:arXiv.org:1911.06434 [pdf] - 2002490
Design and Performance of Hafnium Optical and Near-IR Kinetic Inductance
Detectors
Zobrist, Nicholas;
Coiffard, Grégoire;
Bumble, Bruce;
Swimmer, Noah;
Steiger, Sarah;
Daal, Miguel;
Collura, Giulia;
Walter, Alex B.;
Bockstiegel, Clint;
Fruitwala, Neelay;
Lipartito, Isabel;
Mazin, Benjamin A.
Submitted: 2019-11-14
We report on the design and performance of Microwave Kinetic Inductance
Detectors (MKIDs) sensitive to single photons in the optical to near-infrared
range using hafnium as the sensor material. Our test device had a
superconducting transition temperature of 395 mK and a room temperature normal
state resistivity of 97 $\mu \Omega$ cm with an RRR = 1.6. Resonators on the
device displayed internal quality factors of around 200,000. Similar to the
analysis of MKIDs made from other highly resistive superconductors, we find
that modeling the temperature response of the detector requires an extra
broadening parameter in the superconducting density of states. Finally, we show
that this material and design is compatible with a full-array fabrication
process which resulted in pixels with decay times of about 40 $\mu$s and
resolving powers of ~9 at 800 nm.
[3]
oai:arXiv.org:1908.02775 [pdf] - 1931524
Optical and Near-IR Microwave Kinetic Inductance Detectors (MKIDs) in
the 2020s
Mazin, Benjamin A.;
Bailey, Jeb;
Bartlett, Jo;
Bockstiegel, Clint;
Bumble, Bruce;
Coiffard, Gregoire;
Currie, Thayne;
Daal, Miguel;
Davis, Kristina;
Dodkins, Rupert;
Fruitwala, Neelay;
Jovanovic, Nemanja;
Lipartito, Isabel;
Lozi, Julien;
Males, Jared;
Mawet, Dimitri;
Meeker, Seth;
O'Brien, Kieran;
Rich, Michael;
Smith, Jenny;
Steiger, Sarah;
Swimmer, Noah;
Walter, Alex;
Zobrist, Nick;
Zmuidzinas, Jonas
Submitted: 2019-08-07
Optical and near-IR Microwave Kinetic Inductance Detectors, or MKIDs, are
superconducting photon counting detectors capable of measuring the energy and
arrival time of individual OIR photons without read noise or dark current. In
this whitepaper we will discuss the current status of OIR MKIDs and MKID-based
instruments.
[4]
oai:arXiv.org:1906.03354 [pdf] - 1975296
Stochastic Speckle Discrimination with Time-Tagged Photon Lists: Digging
Below the Speckle Noise Floor
Submitted: 2019-06-07
We present an algorithm that uses the distribution of photon arrival times to
distinguish speckles from incoherent sources, like planets and disks, in high
contrast images. Using simulated data, we show that our approach can overcome
the noise limit from fluctuating speckle intensity. The algorithm is likely to
be most advantageous when a coronagraph limits the coherent diffraction pattern
in the image plane but the intensity is still strongly modulated by
fast-timescale uncorrected stellar light, for example from atmospheric
turbulence. These conditions are common at small inner working angles and will
allow probing of exoplanet populations at smaller angular separations. The
technique requires a fast science camera that can temporally resolve the
speckle fluctuations, and the detection of many photons per speckle
decorrelation time. Since the algorithm directly extracts the incoherent light,
standard differential imaging post-processing techniques can be performed
afterwards to further boost the signal.
[5]
oai:arXiv.org:1809.08301 [pdf] - 1755190
SCExAO, an instrument with a dual purpose: perform cutting-edge science
and develop new technologies
Lozi, Julien;
Guyon, Olivier;
Jovanovic, Nemanja;
Goebel, Sean;
Pathak, Prashant;
Skaf, Nour;
Sahoo, Ananya;
Norris, Barnaby;
Martinache, Frantz;
N'Diaye, Mamadou;
Mazin, Ben;
Walter, Alex B.;
Tuthill, Peter;
Kudo, Tomoyuki;
Kawahara, Hajime;
Kotani, Takayuki;
Ireland, Michael;
Cvetojevic, Nick;
Huby, Elsa;
Lacour, Sylvestre;
Vievard, Sebastien;
Groff, Tyler D.;
Chilcote, Jeffrey K.;
Kasdin, Jeremy;
Knight, Justin;
Snik, Frans;
Doelman, David;
Minowa, Yosuke;
Clergeon, Christophe;
Takato, Naruhisa;
Tamura, Motohide;
Currie, Thayne;
Takami, Hideki;
Hayashi, Masa
Submitted: 2018-09-21
The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument is an
extremely modular high-contrast instrument installed on the Subaru telescope in
Hawaii. SCExAO has a dual purpose. Its position in the northern hemisphere on a
8-meter telescope makes it a prime instrument for the detection and
characterization of exoplanets and stellar environments over a large portion of
the sky. In addition, SCExAO's unique design makes it the ideal instrument to
test innovative technologies and algorithms quickly in a laboratory setup and
subsequently deploy them on-sky. SCExAO benefits from a first stage of
wavefront correction with the facility adaptive optics AO188, and splits the
600-2400 nm spectrum towards a variety of modules, in visible and near
infrared, optimized for a large range of science cases. The integral field
spectrograph CHARIS, with its J, H or K-band high-resolution mode or its
broadband low-resolution mode, makes SCExAO a prime instrument for exoplanet
detection and characterization. Here we report on the recent developments and
scientific results of the SCExAO instrument. Recent upgrades were performed on
a number of modules, like the visible polarimetric module VAMPIRES, the
high-performance infrared coronagraphs, various wavefront control algorithms,
as well as the real-time controller of AO188. The newest addition is the
20k-pixel Microwave Kinetic Inductance Detector (MKIDS) Exoplanet Camera (MEC)
that will allow for previously unexplored science and technology developments.
MEC, coupled with novel photon-counting speckle control, brings SCExAO closer
to the final design of future high-contrast instruments optimized for Giant
Segmented Mirror Telescopes (GSMTs).
[6]
oai:arXiv.org:1803.10420 [pdf] - 1666883
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field
Spectrograph for High-Contrast Astronomy
Meeker, Seth R.;
Mazin, Benjamin A.;
Walter, Alex B.;
Strader, Paschal;
Fruitwala, Neelay;
Bockstiegel, Clint;
Szypryt, Paul;
Ulbricht, Gerhard;
Coiffard, Gregoire;
Bumble, Bruce;
Cancelo, Gustavo;
Zmuda, Ted;
Treptow, Ken;
Wilcer, Neal;
Collura, Giulia;
Dodkins, Rupert;
Lipartito, Isabel;
Zobrist, Nicholas;
Bottom, Michael;
Shelton, J. Chris;
Mawet, Dimitri;
van Eyken, Julian C.;
Vasisht, Gautam;
Serabyn, Eugene
Submitted: 2018-03-28, last modified: 2018-04-16
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving
Superconducting Spectrophotometer), the first of several planned integral field
spectrographs to use optical/near-infrared Microwave Kinetic Inductance
Detectors (MKIDs) for high-contrast imaging. The photon counting and
simultaneous low-resolution spectroscopy provided by MKIDs will enable
real-time speckle control techniques and post-processing speckle suppression at
framerates capable of resolving the atmospheric speckles that currently limit
high-contrast imaging from the ground. DARKNESS is now operational behind the
PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at
Palomar Observatory. Here we describe the motivation, design, and
characterization of the instrument, early on-sky results, and future prospects.
[7]
oai:arXiv.org:1712.08584 [pdf] - 1607148
Pioneering high contrast science instruments for planet characterization
on giant segmented mirror telescopes
Jovanovic, N.;
Guyon, O.;
Lozi, J.;
Tamura, M.;
Norris, B.;
Tuthill, P.;
Huby, E.;
Perrin, G.;
Lacour, S.;
Marchis, F.;
Duchene, G.;
Gauchet, L.;
Ireland, M.;
Feger, T.;
Rains, A.;
Bento, J.;
Schwab, C.;
Coutts, D.;
Cvetojevic, N.;
Gross, S.;
Arriola, A.;
Lagadec, T.;
Goebel, S.;
Hall, D.;
Jacobson, S.;
Mazin, B.;
Walter, A.;
Massie, J.;
Groff, T.;
Chilcote, J.;
Kasdin, J.;
Brandt, T.;
Loomis, C.;
Galvin, M.;
Kotani, T.;
Kawahara, H.;
Martinache, F.;
Pathak, P.;
Males, J.
Submitted: 2017-12-22
A suite of science instruments is critical to any high contrast imaging
facility, as it defines the science capabilities and observing modes available.
SCExAO uses a modular approach which allows for state-of-the-art visitor
modules to be tested within an observatory environment on an 8-m class
telescope. This allows for rapid prototyping of new and innovative imaging
techniques that otherwise take much longer in traditional instrument design.
With the aim of maturing science modules for an advanced high contrast imager
on an giant segmented mirror telescopes (GSMTs) that will be capable of imaging
terrestrial planets, we offer an overview and status update on the various
science modules currently under test within the SCExAO instrument.
[8]
oai:arXiv.org:1710.07318 [pdf] - 1590047
Large-format platinum silicide microwave kinetic inductance detectors
for optical to near-IR astronomy
Szypryt, P.;
Meeker, S. R.;
Coiffard, G.;
Fruitwala, N.;
Bumble, B.;
Ulbricht, G.;
Walter, A. B.;
Daal, M.;
Bockstiegel, C.;
Collura, G.;
Zobrist, N.;
Lipartito, I.;
Mazin, B. A.
Submitted: 2017-10-19
We have fabricated and characterized 10,000 and 20,440 pixel Microwave
Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR
Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID
Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive
optics systems with the goal of directly imaging exoplanets in a 800-1400 nm
band. Previous large optical and near-IR MKID arrays were fabricated using
substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays,
however, suffered from severe non-uniformities in the TiN critical temperature,
causing resonances to shift away from their designed values and lowering usable
detector yield. We have begun fabricating DARKNESS and MEC arrays using
platinum silicide (PtSi) on sapphire instead of TiN. Not only do these arrays
have much higher uniformity than the TiN arrays, resulting in higher pixel
yields, they have demonstrated better spectral resolution than TiN MKIDs of
similar design. PtSi MKIDs also do not display the hot pixel effects seen when
illuminating TiN on silicon MKIDs with photons with wavelengths shorter than 1
um.
[9]
oai:arXiv.org:1610.00725 [pdf] - 1496313
High Quality Factor Platinum Silicide Microwave Kinetic Inductance
Detectors
Submitted: 2016-10-03
We report on the development of Microwave Kinetic Inductance Detectors
(MKIDs) using platinum silicide as the sensor material. MKIDs are an emerging
superconducting detector technology, capable of measuring the arrival times of
single photons to better than two microseconds and their energies to around ten
percent. Previously, MKIDs have been fabricated using either sub-stoichiometric
titanium nitride or aluminum, but TiN suffers from spatial inhomogeneities in
the superconducting critical temperature and Al has a low kinetic inductance
fraction, causing low detector sensitivity. To address these issues, we have
instead fabricated PtSi microresonators with superconducting critical
temperatures of 944$\pm$12~mK and high internal quality factors ($Q_i \gtrsim
10^6$). These devices show typical quasiparticle lifetimes of $\tau_{qp}
\approx 30$--$40~\mu$s and spectral resolution, $R = \lambda / \Delta \lambda$,
of 8 at 406.6~nm. We compare PtSi MKIDs to those fabricated with TiN and detail
the substantial advantages that PtSi MKIDs have to offer.
[10]
oai:arXiv.org:1603.05270 [pdf] - 1385546
Search for Optical Pulsations in PSR J0337+1715
Strader, M. J.;
Archibald, A. M.;
Meeker, S. R.;
Szypryt, P.;
Walter, A. B.;
van Eyken, J. C.;
Ulbricht, G.;
Stoughton, C.;
Bumble, B.;
Kaplan, D. L.;
Mazin, B. A.
Submitted: 2016-03-16
We report on a search for optical pulsations from PSR J0337+1715 at its
observed radio pulse period. PSR J0337+1715 is a millisecond pulsar (2.7 ms
spin period) in a triple hierarchical system with two white dwarfs, and has a
known optical counterpart with g-band magnitude 18. The observations were done
with the Array Camera for Optical to Near-IR Spectrophotometry (ARCONS) at the
200" Hale telescope at Palomar Observatory. No significant pulsations were
found in the range 4000-11000 angstroms, and we can limit pulsed emission in
g-band to be fainter than 25 mag.
[11]
oai:arXiv.org:1507.05631 [pdf] - 1259174
The ARCONS Pipeline: Data Reduction for MKID Arrays
van Eyken, J. C.;
Strader, M. J.;
Walter, A. B.;
Meeker, S. R.;
Szypryt, P.;
Stoughton, C.;
O'Brien, K.;
Marsden, D.;
Rice, N. K.;
Lin, Y.;
Mazin, B. A.
Submitted: 2015-07-20
The Array Camera for Optical to Near-IR Spectrophotometry, or ARCONS, is a
camera based on Microwave Kinetic Inductance Detectors (MKIDs), a new
technology that has the potential for broad application in astronomy. Using an
array of MKIDs, the instrument is able to produce time-resolved imaging and
low-resolution spectroscopy constructed from detections of individual photons.
The arrival time and energy of each photon are recorded in a manner similar to
X-ray calorimetry, but at higher photon fluxes. The technique works over a very
large wavelength range, is free from fundamental read noise and dark-current
limitations, and provides microsecond-level timing resolution. Since the
instrument reads out all pixels continuously while exposing, there is no loss
of active exposure time to readout. The technology requires a different
approach to data reduction compared to conventional CCDs. We outline here the
prototype data reduction pipeline developed for ARCONS, though many of the
principles are also more broadly applicable to energy-resolved photon counting
arrays (e.g., transition edge sensors, superconducting tunnel junctions). We
describe the pipeline's current status, and the algorithms and techniques
employed in taking data from the arrival of photons at the MKID array to the
production of images, spectra, and time-resolved light curves.
[12]
oai:arXiv.org:1506.07537 [pdf] - 1237882
Highly Multiplexible Thermal Kinetic Inductance Detectors for X-Ray
Imaging Spectroscopy
Submitted: 2015-06-24
For X-ray imaging spectroscopy, high spatial resolution over a large field of
view is often as important as high energy resolution, but current X-ray
detectors do not provide both in the same device. Thermal Kinetic Inductance
Detectors (TKIDs) are being developed as they offer a feasible way to combine
the energy resolution of transition edge sensors with pixel counts approaching
CCDs and thus promise significant improvements for many X-ray spectroscopy
applications. TKIDs are a variation of Microwave Kinetic Inductance Detectors
(MKIDs) and share their multiplexibility: working MKID arrays with 2024 pixels
have recently been demonstrated and much bigger arrays are under development.
In this work, we present our first working TKID prototypes which are able to
achieve an energy resolution of 75 eV at 5.9 keV, even though their general
design still has to be optimized. We further describe TKID fabrication,
characterization, multiplexing and working principle and demonstrate the
necessity of a data fitting algorithm in order to extract photon energies. With
further design optimizations we expect to be able to improve our TKID energy
resolution to less than 10 eV at 5.9 keV.
[13]
oai:arXiv.org:1309.3270 [pdf] - 785198
Excess Optical Enhancement Observed with ARCONS for Early Crab Giant
Pulses
Strader, M. J.;
Johnson, M. D.;
Mazin, B. A.;
Jaeger, G. V. Spiro;
Gwinn, C. R.;
Meeker, S. R.;
Szypryt, P.;
van Eyken, J. C.;
Marsden, D.;
O'Brien, K.;
Walter, A. B.;
Ulbricht, G.;
Stoughton, C.;
Bumble, B.
Submitted: 2013-09-12, last modified: 2013-11-08
We observe an extraordinary link in the Crab pulsar between the enhancement
of an optical pulse and the timing of the corresponding giant radio pulse. At
optical through infrared wavelengths, our observations use the high time
resolution of ARCONS, a unique superconducting energy-resolving photon-counting
array at the Palomar 200-inch telescope. At radio wavelengths, we observe with
the Robert C. Byrd Green Bank Telescope and the GUPPI backend. We see an
$11.3\pm2.5\%$ increase in peak optical flux for pulses that have an
accompanying giant radio pulse arriving near the peak of the optical main
pulse, in contrast to a $3.2\pm0.5\%$ increase when an accompanying giant radio
pulse arrives soon after the optical peak. We also observe that the peak of the
optical main pulse is $2.8\pm0.8\%$ enhanced when there is a giant radio pulse
accompanying the optical interpulse. We observe no statistically significant
spectral differences between optical pulses accompanied by and not accompanied
by giant radio pulses. Our results extend previous observations of
optical-radio correlation to the time and spectral domains. Our refined
temporal correlation suggests that optical and radio emission are indeed
causally linked, and the lack of spectral differences suggests that the same
mechanism is responsible for all optical emission.
[14]
oai:arXiv.org:1309.4087 [pdf] - 785202
Direct Detection of SDSS J0926+3624 Orbital Expansion with ARCONS
Szypryt, P.;
Duggan, G. E.;
Mazin, B. A.;
Meeker, S. R.;
Strader, M. J.;
van Eyken, J. C.;
Marsden, D.;
O'Brien, K.;
Walter, A. B.;
Ulbricht, G.;
Prince, T. A.;
Stoughton, C.;
Bumble, B.
Submitted: 2013-09-16
AM Canum Venaticorum (AM CVn) stars belong to a class of ultra-compact, short
period binaries with spectra dominated largely by helium. SDSS J0926+3624 is of
particular interest as it is the first observed eclipsing AM CVn system. We
observed SDSS J0926+3624 with the \textbf{Ar}ray \textbf{C}amera for
\textbf{O}ptical to \textbf{N}ear-IR \textbf{S}pectrophotometry (ARCONS) at the
Palomar 200" telescope. ARCONS uses a relatively new type of energy-resolved
photon counters called Microwave Kinetic Inductance Detectors (MKIDs). ARCONS,
sensitive to radiation from 350 to 1100 nm, has a time resolution of several
microseconds and can measure the energy of a photon to $\sim10%$. We present
the light curves for these observations and examine changes in orbital period
from prior observations. Using a quadratic ephemeris model, we measure a period
rate of change $\dot{P} = (3.07 \pm 0.56)\times 10^{-13}$. In addition, we use
the high timing resolution of ARCONS to examine the system's high frequency
variations and search for possible quasi-periodic oscillations (QPOs). Finally,
we use the instrument's spectral resolution to examine the light curves in
various wavelength bands. We do not find any high frequency QPOs or significant
spectral variability throughout an eclipse.