Normalized to: Walsh, N.
[1]
oai:arXiv.org:1608.08183 [pdf] - 1508211
Galactic Cosmic Ray Origins and OB Associations: Evidence from
SuperTIGER Observations of Elements $_{26}$Fe through $_{40}$Zr
Murphy, R. P.;
Sasaki, M.;
Binns, W. R.;
Brandt, T. J.;
Hams, T.;
Israel, M. H.;
Labrador, A. W.;
Link, J. T.;
Mewaldt, R. A.;
Mitchell, J. W.;
Rauch, B. F.;
Sakai, K.;
Stone, E. C.;
Waddington, C. J.;
Walsh, N. E.;
Ward, J. E.;
Wiedenbeck, M. E.
Submitted: 2016-08-29
We report abundances of elements from $_{26}$Fe to $_{40}$Zr in the cosmic
radiation measured by the SuperTIGER (Trans-Iron Galactic Element Recorder)
instrument during 55 days of exposure on a long-duration balloon flight over
Antarctica. These observations resolve elemental abundances in this charge
range with single-element resolution and good statistics.
These results support a model of cosmic-ray origin in which the source
material consists of a mixture of 19$^{+11}_{-6}$\% material from massive stars
and $\sim$81\% normal interstellar medium (ISM) material with solar system
abundances. The results also show a preferential acceleration of refractory
elements (found in interstellar dust grains) by a factor of $\sim$4 over
volatile elements (found in interstellar gas) ordered by atomic mass (A). Both
the refractory and volatile elements show a mass-dependent enhancement with
similar slopes.
[2]
oai:arXiv.org:1403.1299 [pdf] - 862558
Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chapman, J. J.;
Chiller, A. A.;
Chiller, C.;
Coffey, T.;
Currie, A.;
de Viveiros, L.;
Dobi, A.;
Dobson, J.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Flores, C.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C.;
Hertel, S. A.;
Horn, M.;
Huang, D. Q.;
Ihm, M.;
Jacobsen, R. G.;
Kazkaz, K.;
Knoche, R.;
Larsen, N. A.;
Lee, C.;
Lindote, A.;
Lopes, M. I.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Moongweluwan, M.;
Morad, J.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H.;
Neves, F.;
Ott, R. A.;
Pangilinan, M.;
Parker, P. D.;
Pease, E. K.;
Pech, K.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Solovov, V. N.;
Sorensen, P.;
O'Sullivan, K.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D.;
Tennyson, B.;
Tiedt, D. R.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2014-03-05
The Large Underground Xenon (LUX) dark matter experiment aims to detect rare
low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The
radiogenic backgrounds in the LUX detector have been measured and compared with
Monte Carlo simulation. Measurements of LUX high-energy data have provided
direct constraints on all background sources contributing to the background
model. The expected background rate from the background model for the 85.3 day
WIMP search run is
$(2.6\pm0.2_{\textrm{stat}}\pm0.4_{\textrm{sys}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$
in a 118~kg fiducial volume. The observed background rate is
$(3.6\pm0.4_{\textrm{stat}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$,
consistent with model projections. The expectation for the radiogenic
background in a subsequent one-year run is presented.
[3]
oai:arXiv.org:1402.3731 [pdf] - 788195
A Detailed Look at the First Results from the Large Underground Xenon
(LUX) Dark Matter Experiment
Szydagis, M.;
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chapman, J. J.;
Chiller, A. A.;
Chiller, C.;
Coffey, T.;
Currie, A.;
de Viveiros, L.;
Dobi, A.;
Dobson, J.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Flores, C.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C.;
Hertel, S. A.;
Horn, M.;
Huang, D. Q.;
Ihm, M.;
Jacobsen, R. G.;
Kazkaz, K.;
Knoche, R.;
Larsen, N. A.;
Lee, C.;
Lindote, A.;
Lopes, M. I.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Moongweluwan, M.;
Morad, J.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H.;
Neves, F.;
Ott, R. A.;
Pangilinan, M.;
Parker, P. D.;
Pease, E. K.;
Pech, K.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Solovov, V. N.;
Sorensen, P.;
O'Sullivan, K.;
Sumner, T.;
Taylor, D.;
Tennyson, B.;
Tiedt, D. R.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2014-02-15, last modified: 2014-02-25
LUX, the world's largest dual-phase xenon time-projection chamber, with a
fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is
currently the most sensitive direct dark matter search experiment. The initial
null-result limit on the spin-independent WIMP-nucleon scattering cross-section
was released in October 2013, with a primary scintillation threshold of 2 phe,
roughly 3 keVnr for LUX. The detector has been deployed at the Sanford
Underground Research Facility (SURF) in Lead, South Dakota, and is the first
experiment to achieve a limit on the WIMP cross-section lower than $10^{-45}$
cm$^{2}$. Here we present a more in-depth discussion of the novel energy scale
employed to better understand the nuclear recoil light and charge yields, and
of the calibration sources, including the new internal tritium source. We found
the LUX data to be in conflict with low-mass WIMP signal interpretations of
other results.
[4]
oai:arXiv.org:1310.8214 [pdf] - 795009
First results from the LUX dark matter experiment at the Sanford
Underground Research Facility
LUX Collaboration;
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Bedikian, S.;
Bernard, E.;
Bernstein, A.;
Bolozdynya, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chapman, J. J.;
Chiller, A. A.;
Chiller, C.;
Clark, K.;
Coffey, T.;
Currie, A.;
Curioni, A.;
Dazeley, S.;
de Viveiros, L.;
Dobi, A.;
Dobson, J.;
Dragowsky, E. M.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Flores, C.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C.;
Hanhardt, M.;
Hertel, S. A.;
Horn, M.;
Huang, D. Q.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Knoche, R.;
Kyre, S.;
Lander, R.;
Larsen, N. A.;
Lee, C.;
Leonard, D. S.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Moongweluwan, M.;
Morad, J.;
Morii, M.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Ott, R. A.;
Pangilinan, M.;
Parker, P. D.;
Pease, E. K.;
Pech, K.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Sofka, C. J.;
Solovov, V. N.;
Sorensen, P.;
Stiegler, T.;
O`Sullivan, K.;
Sumner, T. J.;
Svoboda, R.;
Sweany, M.;
Szydagis, M.;
Taylor, D.;
Tennyson, B.;
Tiedt, D. R.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
White, D.;
Witherell, M. S.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2013-10-30, last modified: 2014-02-05
The Large Underground Xenon (LUX) experiment, a dual-phase xenon
time-projection chamber operating at the Sanford Underground Research Facility
(Lead, South Dakota), was cooled and filled in February 2013. We report results
of the first WIMP search dataset, taken during the period April to August 2013,
presenting the analysis of 85.3 live-days of data with a fiducial volume of 118
kg. A profile-likelihood analysis technique shows our data to be consistent
with the background-only hypothesis, allowing 90% confidence limits to be set
on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit
on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33
GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass
WIMP signal interpretations of the results from several recent direct detection
experiments.
[5]
oai:arXiv.org:1205.2272 [pdf] - 873784
An Ultra-Low Background PMT for Liquid Xenon Detectors
Akerib, D. S.;
Bai, X.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Carr, D.;
Chapman, J. J.;
Chan, Y-D.;
Clark, K.;
Coffey, T.;
deViveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Hall, C.;
Hanhardt, M.;
Holbrook, B.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Larsen, N.;
Lee, C.;
Lesko, K.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D.;
Mei, D.;
Mock, J.;
Morii, M.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Pangilinan, M.;
Pech, K.;
Phelps, P.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Solovov, V. N.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Sweany, M.;
Szydagis, M.;
Taylor, D.;
Thomson, J.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2012-05-10, last modified: 2013-06-24
Results are presented from radioactivity screening of two models of
photomultiplier tubes designed for use in current and future liquid xenon
experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark
matter experiment, has yielded a positive detection of four common radioactive
isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered
backgrounds from other detector materials subdominant to the R8778
contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also
been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th
/ <8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to
a change of \times 1/24 238U / \times 1/9 232Th / \times 1/8 40K per PMT,
between R8778 and R11410 MOD, concurrent with a doubling of the photocathode
surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable
between the PMTs, but can be significantly reduced in future R11410 MOD units
through further material selection. Assuming PMT activity equal to the measured
90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs
with R11410 MOD PMTs will change LUX PMT electron recoil background
contributions by a factor of \times1/25 after further material selection for
60Co reduction, and nuclear recoil backgrounds by a factor of \times 1/36. The
strong reduction in backgrounds below the measured R8778 levels makes the
R11410 MOD a very competitive technology for use in large-scale liquid xenon
detectors.
[6]
oai:arXiv.org:1210.4569 [pdf] - 630139
Technical Results from the Surface Run of the LUX Dark Matter Experiment
LUX Collaboration;
Akerib, D. S.;
Bai, X.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chapman, J. J.;
Coffey, T.;
Dobi, A.;
Dragowsky, E.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Gilchriese, M.;
Hall, C.;
Hanhardt, M.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Knoche, R.;
Larsen, N.;
Lee, C.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D.;
Mock, J.;
Moongweluwan, M.;
Morii, M.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Pangilinan, M.;
Pech, K.;
Phelps, P.;
Rodionov, A.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Solovov, V. N.;
Sorensen, P.;
Stiegler, T.;
Sweany, M.;
Szydagis, M.;
Taylor, D.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
de Viveiros, L.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2012-10-16, last modified: 2013-02-22
We present the results of the three-month above-ground commissioning run of
the Large Underground Xenon (LUX) experiment at the Sanford Underground
Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid
xenon detector that will search for cold dark matter in the form of Weakly
Interacting Massive Particles (WIMPs). The commissioning run, conducted with
the detector immersed in a water tank, validated the integration of the various
sub-systems in preparation of the underground deployment. Using the data
collected, we report excellent light collection properties, achieving 8.4
photoelectrons per keV for 662 keV electron recoils without an applied electric
field, measured in the center of the WIMP target. We also find good energy and
position resolution in relatively high-energy interactions from a variety of
internal and external sources. Finally, we have used the commissioning data to
tune the optical properties of our simulation and report updated sensitivity
projections for spin-independent WIMP-nucleon scattering.
[7]
oai:arXiv.org:1207.3665 [pdf] - 1124847
The LUX Prototype Detector: Heat Exchanger Development
Akerib, D. S.;
Bai, X.;
Bedikian, S.;
Bernstein, A.;
Bolozdynya, A.;
Bradley, A.;
Cahn, S.;
Carr, D.;
Chapman, J. J.;
Clark, K.;
Classen, T.;
Curioni, A.;
Dahl, C. E.;
Dazeley, S.;
deViveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Fiorucci, S.;
Gaitskell, R. J.;
Hall, C.;
Faham, C.;
Holbrook, B.;
Kastens, L.;
Kazkaz, K.;
Kwong, J.;
Lander, R.;
Leonard, D.;
Malling, D.;
Mannino, R.;
McKinsey, D. N.;
Mei, D.;
Mock, J.;
Morii, M.;
Nikkel, J.;
Phelps, P.;
Shutt, T.;
Skulski, W.;
Sorensen, P.;
Spaans, J.;
Steigler, T.;
Svoboda, R.;
Sweany, M.;
Thomson, J.;
Tripathi, M.;
Walsh, N.;
Webb, R.;
White, J.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2012-07-16, last modified: 2013-01-20
The LUX (Large Underground Xenon) detector is a two-phase xenon Time
Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter
interactions. As with all noble element detectors, continuous purification of
the detector medium is essential to produce a large ($>$1ms) electron lifetime;
this is necessary for efficient measurement of the electron signal which in
turn is essential for achieving robust discrimination of signal from background
events. In this paper we describe the development of a novel purification
system deployed in a prototype detector. The results from the operation of this
prototype indicated heat exchange with an efficiency above 94% up to a flow
rate of 42 slpm, allowing for an electron drift length greater than 1 meter to
be achieved in approximately two days and sustained for the duration of the
testing period.
[8]
oai:arXiv.org:1110.0103 [pdf] - 967104
After LUX: The LZ Program
Malling, D. C.;
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bedikian, S.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Carr, D.;
Chapman, J. J.;
Clark, K.;
Classen, T.;
Coffey, T.;
Curioni, A.;
Currie, A.;
Dazeley, S.;
de Viveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Hall, C.;
Hanhardt, M.;
Holbrook, B.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Lander, R.;
Larsen, N.;
Lee, C.;
Leonard, D.;
Lesko, K.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Majewski, P.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Morii, M.;
Murphy, A. St J.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Pangilinan, M.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Solovov, V.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Sumner, T. J.;
Svoboda, R.;
Sweany, M.;
Szydagis, M.;
Thomson, J.;
Tripathi, M.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2011-10-01, last modified: 2011-10-13
The LZ program consists of two stages of direct dark matter searches using
liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the
last stage will be a 20 tonne detector. Both devices will benefit tremendously
from research and development performed for the LUX experiment, a 350 kg liquid
Xe dark matter detector currently operating at the Sanford Underground
Laboratory. In particular, the technology used for cryogenics and electrical
feedthroughs, circulation and purification, low-background materials and
shielding techniques, electronics, calibrations, and automated control and
recovery systems are all directly scalable from LUX to the LZ detectors.
Extensive searches for potential background sources have been performed, with
an emphasis on previously undiscovered background sources that may have a
significant impact on tonne-scale detectors. The LZ detectors will probe
spin-independent interaction cross sections as low as 5E-49 cm2 for 100 GeV
WIMPs, which represents the ultimate limit for dark matter detection with
liquid xenon technology.
[9]
oai:arXiv.org:1108.1836 [pdf] - 1083296
Data Acquisition and Readout System for the LUX Dark Matter Experiment
Akerib, D. S.;
Bai, X.;
Bedikian, S.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Carr, D.;
Chapman, J. J.;
Clark, K.;
Classen, T.;
Coffey, T.;
Curioni, A.;
Dazeley, S.;
deViveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Hall, C.;
Hanhardt, M.;
Holbrook, B.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Lander, R.;
Larsen, N.;
Lee, C.;
Leonard, D.;
Lesko, K.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D.;
Mock, J.;
Morii, M.;
Nelson, H.;
Nikkel, J. A.;
Pangilinan, M.;
Phelps, P.;
Shutt, T.;
Skulski, W.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Svoboda, R.;
Sweany, M.;
Szydagis, M.;
Thomson, J.;
Tripathi, M.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2011-08-08, last modified: 2011-08-09
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to
detect nuclear recoils from interactions with dark matter particles. Signals
from the LUX detector are processed by custom-built analog electronics which
provide properly shaped signals for the trigger and data acquisition (DAQ)
systems. The DAQ is comprised of commercial digitizers with firmware customized
for the LUX experiment. Data acquisition systems in rare-event searches must
accommodate high rate and large dynamic range during precision calibrations
involving radioactive sources, while also delivering low threshold for maximum
sensitivity. The LUX DAQ meets these challenges using real-time baseline sup-
pression that allows for a maximum event acquisition rate in excess of 1.5 kHz
with virtually no deadtime. This paper describes the LUX DAQ and the novel
acquisition techniques employed in the LUX experiment.
[10]
oai:arXiv.org:0912.0482 [pdf] - 902613
Status of the LUX Dark Matter Search
Fiorucci, S.;
Akerib, D. S.;
Bedikian, S.;
Bernstein, A.;
Bolozdynya, A.;
Bradley, A.;
Carr, D.;
Chapman, J.;
Clark, K.;
Classen, T.;
Curioni, A.;
Dahl, E.;
Dazeley, S.;
de Viveiros, L.;
Druszkiewicz, E.;
Gaitskell, R.;
Hall, C.;
Faham, C. Hernandez;
Holbrook, B.;
Kastens, L.;
Kazkaz, K.;
Lander, R.;
Lesko, K.;
Malling, D.;
Mannino, R.;
McKinsey, D.;
Mei, D.;
Mock, J.;
Nikkel, J.;
Phelps, P.;
Schroeder, U.;
Shutt, T.;
Skulski, W.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Svoboda, R.;
Sweany, M.;
Thomson, J.;
Toke, J.;
Tripathi, M.;
Walsh, N.;
Webb, R.;
White, J.;
Wolfs, F.;
Woods, M.;
Zhang, C.
Submitted: 2009-12-02
The Large Underground Xenon (LUX) dark matter search experiment is currently
being deployed at the Homestake Laboratory in South Dakota. We will highlight
the main elements of design which make the experiment a very strong competitor
in the field of direct detection, as well as an easily scalable concept. We
will also present its potential reach for supersymmetric dark matter detection,
within various timeframes ranging from 1 year to 5 years or more.