[1]  oai:arXiv.org:2003.11899  [pdf] - 2070581
Progress in the development of frequency domain multiplexing for the X-ray Integral Field Unit on board the Athena mission
Comments: 7 pages, 5 figures. Published on Journal of Low Temperature Physics (2020)
Submitted: 2020-03-26
Frequency domain multiplexing (FDM) is the baseline readout system for the X-ray Integral Field Unit (X-IFU) on board the Athena mission. Under the FDM scheme, TESs are coupled to a passive LC filter and biased with alternating current (AC bias) at MHz frequencies. Using high-quality factor LC filters and room temperature electronics developed at SRON and low-noise two-stage SQUID amplifiers provided by VTT, we have recently demonstrated good performance with the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. We have achieved a performance requested for the demonstration model (DM) with the single pixel AC bias ($\Delta E=$1.8 eV) and 9 pixel multiplexing ($\Delta E=$2.6 eV) modes. We have also demonstrated 14-pixel multiplexing with an average energy resolution of 3.3 eV, which is limited by non-fundamental issues related to FDM readout in our lab setup.
[2]  oai:arXiv.org:1908.02687  [pdf] - 2050188
Towards 100,000-pixel microcalorimeter arrays using multi-absorber transition-edge sensors
Comments: 7 pages, 5 figures. Low Temperature Detectors 18 Conference, Milan Italy
Submitted: 2019-08-07
We report on the development of multi-absorber transition edge sensors (TESs), referred to as hydras. A hydra consists of multiple x-ray absorbers each with a different thermal conductance to a TES. Position information is encoded in the pulse shape. With some trade-off in performance, hydras enable very large format arrays without the prohibitive increase in bias and read-out components associated with arrays of individual TESs. Hydras are under development for the next generation of space telescope such as Lynx. Lynx is a NASA concept under study that will combine a < 1 arcsecond angular resolution optic with 100,000-pixel microcalorimeter array with energy resolution of deltaE_FWHM ~ 3 eV in the soft x-ray energy range. We present first results from hydras with 25-pixels for Lynx. Designs with absorbers on a 25 micron and 50 micron pitch are studied. Arrays incorporate, for the first time, microstrip buried wiring layers of suitable pitch and density required to readout a full-scale Lynx array. The resolution from the coadded energy histogram including all 25-pixels was deltaE_FWHM = 1.66+/-0.02 eV and 3.34+/-0.06 eV at an energy of 1.5 keV for the 25 micron and 50 micron absorber designs respectively. Position discrimination is demonstrated from parameterization of the rise-time.