Waczynski, Augustyn
Normalized to: Waczynski, A.
3 article(s) in total. 30 co-authors, from 1 to 2 common article(s). Median position in authors list is 5,0.
[1]
oai:arXiv.org:2005.00505 [pdf] - 2087557
Properties and characteristics of the WFIRST H4RG-10 detectors
Mosby,, Gregory;
Rauscher, Bernard J.;
Bennett, Chris;
Cheng, Edward . S.;
Cheung, Stephanie;
Cillis, Analia;
Content, David;
Cottingham, Dave;
Foltz, Roger;
Gygax, John;
Hill, Robert J.;
Kruk, Jeffrey W.;
Mah, Jon;
Meier, Lane;
Merchant, Chris;
Miko, Laddawan;
Piquette, Eric C.;
Waczynski, Augustyn;
Wen, Yiting
Submitted: 2020-05-01
The Wide-Field Infrared Survey Telescope (WFIRST) will answer fundamental
questions about the evolution of dark energy over time and expand the catalog
of known exoplanets into new regions of parameter space. Using a Hubble-sized
mirror and 18 newly developed HgCdTe 4K x 4K photodiode arrays (H4RG-10),
WFIRST will measure the positions and shapes of hundreds of millions of
galaxies, the light curves of thousands of supernovae, and the microlensing
signals of over a thousand exoplanets toward the bulge of the Galaxy. These
measurements require unprecedented sensitivity and characterization of the Wide
Field Instrument (WFI), particularly its detectors. The WFIRST project
undertook an extensive detector development program to create focal plane
arrays that meet these science requirements. These prototype detectors have
been characterized and their performance demonstrated in a relevant space-like
environment (thermal vacuum, vibration, acoustic, and radiation testing),
advancing the H4RG-10's technology readiness level (TRL) to TRL-6. We present
the performance characteristics of these TRL-6 demonstration devices.
[2]
oai:arXiv.org:1203.5740 [pdf] - 1117560
Inter-Pixel Crosstalk in Teledyne Imaging Sensors (TIS) H4RG-10
Detectors
Dudik, R. P.;
Jordan, M.;
Dorland, B. N.;
Veillette, D.;
Waczynski, A.;
Lane, B.;
Loose, M.;
Kan, E.;
Waterman, J.;
Pravdo, S.
Submitted: 2012-03-26, last modified: 2012-04-02
CMOS-hybrid arrays have recently surfaced as competitive optical detectors
for use in ground- and space-based astronomy. One source of error in these
detectors that does not appear in more traditional CCD arrays is the
inter-pixel capacitance component of crosstalk. In this paper we use a single
pixel reset method to model inter-pixel capacitance (IPC). We combine this IPC
model with a model for charge diffusion to estimate the total crosstalk on H4RG
arrays. Finally, we compare our model results to Fe55 data obtained using an
astrometric camera built to test the H4RG-B0 generation detectors.
[3]
oai:arXiv.org:0906.0579 [pdf] - 1002440
The ^{55}Fe X-ray Energy Response of Mercury Cadmium Telluride
Near-Infrared Detector Arrays
Submitted: 2009-06-02
A technique involving ^{55}Fe X-rays provides a straightforward method to
measure the response of a detector. The detector's response can lead directly
to a calculation of the conversion gain (e^- ADU^{-1}), as well as aid detector
design and performance studies. We calibrate the ^{55}Fe X-ray energy response
and pair production energy of HgCdTe using 8 HST WFC3 1.7 \micron flight grade
detectors. The results show that each K$\alpha$ X-ray generates 2273 \pm 137
electrons, which corresponds to a pair-production energy of 2.61 \pm 0.16 eV.
The uncertainties are dominated by our knowledge of the conversion gain. In
future studies, we plan to eliminate this uncertainty by directly measuring
conversion gain at very low light levels.