sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Vorobiev, Dmitry

Normalized to: Vorobiev, D.

6 article(s) in total. 64 co-authors, from 1 to 6 common article(s). Median position in authors list is 1,0.

[1]  oai:arXiv.org:1909.12785  [pdf] - 2045242
Imaging Polarimetry of the 2017 Solar Eclipse with the RIT Polarization Imaging Camera
Comments: 16 pages, 13 figures. Submitted to PASP September, 2019
Submitted: 2019-09-27
In the last decade, imaging polarimeters based on micropolarizer arrays have been developed for use in terrestrial remote sensing and metrology applications. Micropolarizer-based sensors are dramatically smaller and more mechanically robust than other polarimeters with similar spectral response and snapshot capability. To determine the suitability of these new polarimeters for astronomical applications, we developed the RIT Polarization Imaging Camera to investigate the performance of these devices, with a special attention to the low signal-to-noise regime. We characterized the device performance in the lab, by determining the relative throughput, efficiency, and orientation of every pixel, as a function of wavelength. Using the resulting pixel response model, we developed demodulation procedures for aperture photometry and imaging polarimetry observing modes. We found that, using the current calibration, RITPIC is capable of detecting polarization signals as small as <0.3%. To demonstrate the stability of RITPIC's calibration and its extreme portability, we performed imaging polarimetry of the Solar corona in Madras, Oregon during the total Solar eclipse of 2017. The maximum polarization we measured was ~46%, which agrees well with the maximum value predicted for a Thomson scattering corona. Similarly, we found no strong deviations in the angle of linear polarization from the tangential direction. The relative ease of data collection, calibration, and analysis provided by these sensors suggest than they may become an important tool for a number of astronomical targets.
[2]  oai:arXiv.org:1909.12248  [pdf] - 1969112
Direct measurement of the Kepler Space Telescope CCD's intra-pixel response function
Comments: 19 pages, 20 figures; Accepted to Journal of Astronomical Telescopes, Instruments, and Systems (September 2019)
Submitted: 2019-09-26
Space missions designed for high precision photometric monitoring of stars often under-sample the point-spread function, with much of the light landing within a single pixel. Missions like MOST, Kepler, BRITE, and TESS, do this to avoid uncertainties due to pixel-to-pixel response nonuniformity. This approach has worked remarkably well. However, individual pixels also exhibit response nonuniformity. Typically, pixels are most sensitive near their centers and less sensitive near the edges, with a difference in response of as much as 50%. The exact shape of this fall-off, and its dependence on the wavelength of light, is the intra-pixel response function (IPRF). A direct measurement of the IPRF can be used to improve the photometric uncertainties, leading to improved photometry and astrometry of under-sampled systems. Using the spot-scan technique, we measured the IPRF of a flight spare e2v CCD90 imaging sensor, which is used in the Kepler focal plane. Our spot scanner generates spots with a full-width at half-maximum of $\lesssim$3 microns across the range of 400 nm - 850 nm. We find that Kepler's CCD shows similar IPRF behavior to other back-illuminated devices, with a decrease in responsivity near the edges of a pixel by $\sim$50%. The IPRF also depends on wavelength, exhibiting a large amount of diffusion at shorter wavelengths and becoming much more defined by the gate structure in the near-IR. This method can also be used to measure the IPRF of the CCDs used for TESS, which borrows much from the Kepler mission.
[3]  oai:arXiv.org:1909.00070  [pdf] - 1953783
ATLAS Probe: Breakthrough Science of Galaxy Evolution, Cosmology, Milky Way, and the Solar System
Comments: APC white paper submitted to Astro2020. arXiv admin note: substantial text overlap with arXiv:1802.01539
Submitted: 2019-08-30
ATLAS (Astrophysics Telescope for Large Area Spectroscopy) is a concept for a NASA probe-class space mission. It is the spectroscopic follow-up mission to WFIRST, boosting its scientific return by obtaining deep NIR & MIR slit spectroscopy for most of the galaxies imaged by the WFIRST High Latitude Survey at z>0.5. ATLAS will measure accurate and precise redshifts for ~200M galaxies out to z=7 and beyond, and deliver spectra that enable a wide range of diagnostic studies of the physical properties of galaxies over most of cosmic history. ATLAS and WFIRST together will produce a definitive 3D map of the Universe over 2000 sq deg. ATLAS Science Goals are: (1) Discover how galaxies have evolved in the cosmic web of dark matter from cosmic dawn through the peak era of galaxy assembly. (2) Discover the nature of cosmic acceleration. (3) Probe the Milky Way's dust-enshrouded regions, reaching the far side of our Galaxy. (4) Discover the bulk compositional building blocks of planetesimals formed in the outer Solar System. These flow down to the ATLAS Scientific Objectives: (1A) Trace the relation between galaxies and dark matter with less than 10% shot noise on relevant scales at 1<z<7. (1B) Probe the physics of galaxy evolution at 1<z<7. (2) Obtain definitive measurements of dark energy and tests of General Relativity. (3) Measure the 3D structure and stellar content of the inner Milky Way to a distance of 25 kpc. (4) Detect and quantify the composition of 3,000 planetesimals in the outer Solar System. ATLAS is a 1.5m telescope with a FoV of 0.4 sq deg, and uses Digital Micro-mirror Devices (DMDs) as slit selectors. It has a spectroscopic resolution of R = 1000, and a wavelength range of 1-4 microns. ATLAS has an unprecedented spectroscopic capability based on DMDs, with a spectroscopic multiplex factor ~6,000. ATLAS is designed to fit within the NASA probe-class space mission cost envelope.
[4]  oai:arXiv.org:1806.07430  [pdf] - 1702871
Direct measurement of the intra-pixel response function of Kepler Space Telescope's CCDs
Comments: This paper was presented as poster 10698-193 at the SPIE Astronomical Telescopes and Instrumentation meeting on June 12, 2018 in Austin, Texas, USA
Submitted: 2018-06-19
Space missions designed for high precision photometric monitoring of stars often under-sample the point-spread function, with much of the light landing within a single pixel. Missions like MOST, Kepler, BRITE, and TESS, do this to avoid uncertainties due to pixel-to-pixel response nonuniformity. This approach has worked remarkably well. However, individual pixels also exhibit response nonuniformity. Typically, pixels are most sensitive near their centers and less sensitive near the edges, with a difference in response of as much as 50%. The exact shape of this fall-off, and its dependence on the wavelength of light, is the intra-pixel response function (IPRF). A direct measurement of the IPRF can be used to improve the photometric uncertainties, leading to improved photometry and astrometry of under-sampled systems. Using the spot-scan technique, we measured the IPRF of a flight spare e2v CCD90 imaging sensor, which is used in the Kepler focal plane. Our spot scanner generates spots with a full-width at half-maximum of $\lesssim$5 microns across the range of 400 nm - 900 nm. We find that Kepler's CCD shows similar IPRF behavior to other back-illuminated devices, with a decrease in responsivity near the edges of a pixel by $\sim$50%. The IPRF also depends on wavelength, exhibiting a large amount of diffusion at shorter wavelengths and becoming much more defined by the gate structure in the near-IR. This method can also be used to measure the IPRF of the CCDs used for TESS, which borrows much from the Kepler mission.
[5]  oai:arXiv.org:1710.04255  [pdf] - 1671979
Astronomical Polarimetry with the RIT Polarization Imaging Camera
Comments: As part of the review process, it was decided to split the original manuscript into two papers: one describing the instrument and observations on the 0.9 m telescope at CTIO and the second, describing the solar eclipse data, obtained in Madras, Oregon. This is the first of the two papers
Submitted: 2017-10-11, last modified: 2018-04-24
In the last decade, imaging polarimeters based on micropolarizer arrays have been developed for use in terrestrial remote sensing and metrology applications. Micropolarizer-based sensors are dramatically smaller and more mechanically robust than other polarimeters with similar spectral response and snapshot capability. To determine the suitability of these new polarimeters for astronomical applications, we developed the RIT Polarization Imaging Camera to investigate the performance of these devices, with a special attention to the low signal-to-noise regime. We characterized the device performance in the lab, by determining the relative throughput, efficiency, and orientation of every pixel, as a function of wavelength. Using the resulting pixel response model, we developed demodulation procedures for aperture photometry and imaging polarimetry observing modes. We found that, using the current calibration, RITPIC is capable of detecting polarization signals as small as $\sim0.3\%$. The relative ease of data collection, calibration, and analysis provided by these sensors suggest than they may become an important tool for a number of astronomical targets.
[6]  oai:arXiv.org:1708.06241  [pdf] - 1587312
Evaluation of Digital Micromirror Devices for use in space-based Multi-Object Spectrometer application
Comments:
Submitted: 2017-08-21
The astronomical community continues to be interested in suitable programmable slit masks for use in multi-object spectrometers (MOSs) on space missions. There have been ground-based MOS utilizing digital micromirror devices (DMDs) and they have proven to be highly accurate and reliable instruments. This paper summarizes the results of a continuing study to investigate the performance of DMDs under conditions associated with space deployment. This includes the response of DMDs to radiation, to the vibration and mechanical shock loads associated with launch, and the operability of DMD under cryogenic temperatures. The optical contrast ratio and a study of the long-term reflectance of a bare device have also been investigated. The results of the radiation testing demonstrate that DMDs in orbit would experience negligible heavy-ion induced single event upset (SEU) rate burden, we predict SEU rate of 5.6 micromirrors per 24 hours. Vibration and mechanical shock testing was performed according to the NASA General Environmental Verification Standard (GEVS), no mirrors failed in the devices tested. The results of low temperature testing suggest that DMDs are not affected by the thermal load and operate smoothly at temperatures at least as low as 78 K. The reflectivity of a bare DMD did not measurably change even after being exposed to ambient conditions over a period of 13 months. The measured contrast ratio (on state vs off state of the DMD micromirrors) was greater than 6000/:1 when illuminated with an f/4 optical beam. Overall, DMDs are extremely robust and promise to provide a reliable alternative to micro shutter arrays (MSA) to be used in space as remotely programmable slit masks for MOS design.