Normalized to: Volpe, A.
[1]
oai:arXiv.org:2006.14889 [pdf] - 2122751
A chemically etched corrugated feedhorn array for D-band CMB
observations
Mandelli, Stefano;
Manzan, Elenia;
Mennella, Aniello;
Cavaliere, Francesco;
Viganò, Daniele;
Franceschet, Cristian;
de Bernardis, Paolo;
Bersanelli, Marco;
Castellano, Maria Gabriella;
Coppolecchia, Alessandro;
Cruciani, Angelo;
Gervasi, Massimo;
Lamagna, Luca;
Limonta, Andrea;
Masi, Silvia;
Paiella, Alessandro;
Passerini, Andrea;
Pettinari, Giorgio;
Piacentini, Francesco;
Tommasi, Elisabetta;
Volpe, Angela;
Zannoni, Mario
Submitted: 2020-06-26
We present the design, manufacturing, and testing of a 37-element array of
corrugated feedhorns for Cosmic Microwave Background (CMB) measurements between
$140$ and $170$ GHz. The array was designed to be coupled to Kinetic Inductance
Detector arrays, either directly (for total power measurements) or through an
orthomode transducer (for polarization measurements). We manufactured the array
in platelets by chemically etching aluminum plates of $0.3$ mm and $0.4$ mm
thickness. The process is fast, low-cost, scalable, and yields high-performance
antennas compared to other techniques in the same frequency range. Room
temperature electromagnetic measurements show excellent repeatability with an
average cross polarization level about $-20$ dB, return loss about $-25$ dB,
first sidelobes below $-25$ dB and far sidelobes below $-35$ dB. Our results
qualify this process as a valid candidate for state-of-the-art CMB experiments,
where large detector arrays with high sensitivity and polarization purity are
of paramount importance in the quest for the discovery of CMB polarization
$B$-modes.
[2]
oai:arXiv.org:2005.01187 [pdf] - 2089273
Progress report on the Large Scale Polarization Explorer
Lamagna, L.;
Addamo, G.;
Ade, P. A. R.;
Baccigalupi, C.;
Baldini, A. M.;
Battaglia, P. M.;
Battistelli, E.;
Baù, A.;
Bersanelli, M.;
Biasotti, M.;
Boragno, C.;
Boscaleri, A.;
Caccianiga, B.;
Caprioli, S.;
Cavaliere, F.;
Cei, F.;
Cleary, K. A.;
Columbro, F.;
Coppi, G.;
Coppolecchia, A.;
Corsini, D.;
Cuttaia, F.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Petris, M.;
Del Torto, F.;
Fafone, V.;
Farooqui, Z.;
Farsian, F.;
Fontanelli, F.;
Franceschet, C.;
Gaier, T. C.;
Gatti, F.;
Genova-Santos, R.;
Gervasi, M.;
Ghigna, T.;
Grassi, M.;
Grosso, D.;
Gualtieri, R.;
Incardona, F.;
Jones, M.;
Kangaslahti, P.;
Krachmalnicoff, N.;
Mainini, R.;
Maino, D.;
Mandelli, S.;
Maris, M.;
Masi, S.;
Matarrese, S.;
May, A.;
Mena, P.;
Mennella, A.;
Molina, R.;
Molinari, D.;
Morgante, G.;
Nati, F.;
Natoli, P.;
Pagano, L.;
Paiella, A.;
Paonessa, F.;
Passerini, A.;
Perez-de-Taoro, M.;
Peverini, O. A.;
Pezzotta, F.;
Piacentini, F.;
Piccirillo, L.;
Pisano, G.;
Polastri, L.;
Polenta, G.;
Poletti, D.;
Presta, G.;
Realini, S.;
Reyes, N.;
Rocchi, A.;
Rubiño-Martin, J. A.;
Sandri, M.;
Sartor, S.;
Schillaci, A.;
Signorelli, G.;
Siri, B.;
Soria, M.;
Spinella, F.;
Tapia, V.;
Tartari, A.;
Taylor, A.;
Terenzi, L.;
Tomasi, M.;
Tommasi, E.;
Tucker, C.;
Vaccaro, D.;
Vigano, D. M.;
Villa, F.;
Virone, G.;
Vittorio, N.;
Volpe, A.;
Watkins, B.;
Zacchei, A.;
Zannoni, M.
Submitted: 2020-05-03, last modified: 2020-05-05
The Large Scale Polarization Explorer (LSPE) is a cosmology program for the
measurement of large scale curl-like features (B-modes) in the polarization of
the Cosmic Microwave Background. Its goal is to constrain the background of
inflationary gravity waves traveling through the universe at the time of
matter-radiation decoupling. The two instruments of LSPE are meant to
synergically operate by covering a large portion of the northern microwave sky.
LSPE/STRIP is a coherent array of receivers planned to be operated from the
Teide Observatory in Tenerife, for the control and characterization of the
low-frequency polarized signals of galactic origin; LSPE/SWIPE is a
balloon-borne bolometric polarimeter based on 330 large throughput multi-moded
detectors, designed to measure the CMB polarization at 150 GHz and to monitor
the polarized emission by galactic dust above 200 GHz. The combined performance
and the expected level of systematics mitigation will allow LSPE to constrain
primordial B-modes down to a tensor/scalar ratio of $10^{-2}$. We here report
the status of the STRIP pre-commissioning phase and the progress in the
characterization of the key subsystems of the SWIPE payload (namely the
cryogenic polarization modulation unit and the multi-moded TES pixels) prior to
receiver integration.
[3]
oai:arXiv.org:2002.03589 [pdf] - 2045578
In-flight performance of the LEKIDs of the OLIMPO experiment
Paiella, A.;
Ade, P. A. R.;
Battistelli, E. S.;
Castellano, M. G.;
Colantoni, I.;
Columbro, F.;
Coppolecchia, A.;
D'Alessandro, G.;
de Bernardis, P.;
De Petris, M.;
Gordon, S.;
Lamagna, L.;
Magneville, C.;
Masi, S.;
Mauskopf, P.;
Pettinari, G.;
Piacentini, F.;
Pisano, G.;
Polenta, G.;
Presta, G.;
Tommasi, E.;
Tucker, C.;
Vdovin, V.;
Volpe, A.;
Yvon, D.
Submitted: 2020-02-10
We describe the in-flight performance of the horn-coupled Lumped Element
Kinetic Inductance Detector arrays of the balloon-borne OLIMPO experiment.
These arrays have been designed to match the spectral bands of OLIMPO: 150,
250, 350, and 460 GHz, and they have been operated at 0.3 K and at an altitude
of 37.8 km during the stratospheric flight of the OLIMPO payload, in Summer
2018. During the first hours of flight, we tuned the detectors and verified
their large dynamics under the radiative background variations due to elevation
increase of the telescope and to the insertion of the plug-in room-temperature
differential Fourier transform spectrometer into the optical chain. We have
found that the detector noise equivalent powers are close to be photon-noise
limited and lower than those measured on the ground. Moreover, the data
contamination due to primary cosmic rays hitting the arrays is less than 3% for
all the pixels of all the arrays, and less than 1% for most of the pixels.
These results can be considered the first step of KID technology validation in
a representative space environment.
[4]
oai:arXiv.org:1912.06390 [pdf] - 2014523
The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence
Detector
D'Andrea, Matteo;
Macculi, Claudio;
Torrioli, Guido;
Argan, Andrea;
Brienza, Daniele;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Barusso, Lorenzo Ferrari;
Gatti, Flavio;
Rigano, Manuela;
Volpe, Angela;
Battistelli, Elia Stefano
Submitted: 2019-12-13
The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed
to reduce the particle background of the instrument and to enable the mission
science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES
network. We have developed the CryoAC Demonstration Model, a prototype aimed to
probe the critical technologies of the detector, i.e. the suspended absorber
with an active area of 1 cm2; the low energy threshold of 20 keV; and the
operation connected to a 50 mK thermal bath with a power dissipation less than
40 nW. Here we report the test performed on the first CryoAC DM sample (namely
the AC-S10 prototype), showing that it is fully compliant with its
requirements.
[5]
oai:arXiv.org:1902.08993 [pdf] - 1912750
Kinetic Inductance Detectors for the OLIMPO experiment: in--flight
operation and performance
Masi, S.;
de Bernardis, P.;
Paiella, A.;
Piacentini, F.;
Lamagna, L.;
Coppolecchia, A.;
Ade, P. A. R.;
Battistelli, E. S.;
Castellano, M. G.;
Colantoni, I.;
Columbro, F.;
D'Alessandro, G.;
De Petris, M.;
Gordon, S.;
Magneville, C.;
Mauskopf, P.;
Pettinari, G.;
Pisano, G.;
Polenta, G.;
Presta, G.;
Tommasi, E.;
Tucker, C.;
Vdovin, V.;
Volpe, A.;
Yvon, D.
Submitted: 2019-02-24
We report on the performance of lumped--elements Kinetic Inductance Detector
(KID) arrays for mm and sub--mm wavelengths, operated at 0.3K during the
stratospheric flight of the OLIMPO payload, at an altitude of 37.8 km. We find
that the detectors can be tuned in-flight, and their performance is robust
against radiative background changes due to varying telescope elevation. We
also find that the noise equivalent power of the detectors in flight is
significantly reduced with respect to the one measured in the laboratory, and
close to photon-noise limited performance. The effect of primary cosmic rays
crossing the detector is found to be consistent with the expected ionization
energy loss with phonon-mediated energy transfer from the ionization sites to
the resonators. In the OLIMPO detector arrays, at float, cosmic ray events
affect less than 4% of the detector samplings for all the pixels of all the
arrays, and less than 1% of the samplings for most of the pixels. These results
are also representative of what one can expect from primary cosmic rays in a
satellite mission with similar KIDs and instrument environment.
[6]
oai:arXiv.org:1812.03687 [pdf] - 1795038
The STRIP instrument of the Large Scale Polarization Explorer: microwave
eyes to map the Galactic polarized foregrounds
Franceschet, C.;
Realini, S.;
Mennella, A.;
Addamo, G.;
Baù, A.;
Battaglia, P. M.;
Bersanelli, M.;
Caccianiga, B.;
Caprioli, S.;
Cavaliere, F.;
Cleary, K. A.;
Cuttaia, F.;
Del Torto, F.;
Fafone, V.;
Farooqui, Z.;
Santos, R. T. Génova;
Gaier, T. C.;
Gervasi, M.;
Ghigna, T.;
Incardona, F.;
Iovenitti, S.;
Jones, M.;
Kangaslahti, P.;
Mainini, R.;
Maino, D.;
Maris, M.;
Mena, P.;
Molina, R.;
Morgante, G.;
Passerini, A.;
Perez-de-Taoro, M.;
Peverini, O. A.;
Pezzotta, F.;
Pincella, C.;
Reyes, N.;
Rocchi, A.;
Rubiño-Martín, J. A.;
Sandri, M.;
Sartor, S.;
Soria, M.;
Tapia, V.;
Terenzi, L.;
Tomasi, M.;
Tommasi, E.;
Viganó, D. M.;
Villa, F.;
Virone, G.;
Volpe, A.;
Watkins, B.;
Zacchei, A.;
Zannoni, M.
Submitted: 2018-12-10
In this paper we discuss the latest developments of the STRIP instrument of
the "Large Scale Polarization Explorer" (LSPE) experiment. LSPE is a novel
project that combines ground-based (STRIP) and balloon-borne (SWIPE)
polarization measurements of the microwave sky on large angular scales to
attempt a detection of the "B-modes" of the Cosmic Microwave Background
polarization. STRIP will observe approximately 25% of the Northern sky from the
"Observatorio del Teide" in Tenerife, using an array of forty-nine coherent
polarimeters at 43 GHz, coupled to a 1.5 m fully rotating crossed-Dragone
telescope. A second frequency channel with six-elements at 95 GHz will be
exploited as an atmospheric monitor. At present, most of the hardware of the
STRIP instrument has been developed and tested at sub-system level.
System-level characterization, starting in July 2018, will lead STRIP to be
shipped and installed at the observation site within the end of the year. The
on-site verification and calibration of the whole instrument will prepare STRIP
for a 2-years campaign for the observation of the CMB polarization.
[7]
oai:arXiv.org:1807.08565 [pdf] - 1720396
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: improvement of
the test setup towards the Demonstration Model
D'Andrea, Matteo;
Macculi, Claudio;
Argan, Andrea;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Corsini, Dario;
Gatti, Flavio;
Torrioli, Guido;
Volpe, Angela
Submitted: 2018-07-23
The ATHENA X-IFU development program foresees to build and characterize an
instrument Demonstration Model (DM), in order to probe the system critical
technologies before the mission adoption. In this respect, we are now
developing the DM of the X-IFU Cryogenic Anticoincidence Detector (CryoAC),
which will be delivered to the Focal Plane Assembly (FPA) development team for
the integration with the TES array. Before the delivery, we will characterize
and test the CryoAC DM in our CryoLab at INAF/IAPS. In this paper we report the
main results of the activities performed to improve our cryogenic test setup,
making it suitable for the DM integration. These activities mainly consist in
the development of a mechanichal setup and a cryogenic magnetic shielding
system, whose effectiveness has been assessed by FEM simulations and a
measurement at warm. The preliminary performance test has been performed by
means of the last CryoAC single pixel prototype, the AC-S8 pre-DM sample.
[8]
oai:arXiv.org:1807.02344 [pdf] - 1714361
The Cryogenic Anticoincidence Detector for ATHENA X-IFU: Preliminary
test of AC-S9 towards the Demonstration Model
D'Andrea, Matteo;
Macculi, Claudio;
Argan, Andrea;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Ceriale, Valentina;
Gallucci, Giovanni;
Gatti, Flavio;
Torrioli, Guido;
Volpe, Angela
Submitted: 2018-07-06, last modified: 2018-07-11
Our team is developing the Cryogenic Anticoincidence Detector (CryoAC) of the
ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector,
which will be placed less than 1 mm below the main TES array detector. We are
now producing the CryoAC Demonstration Model (DM): a single pixel prototype
able to probe the detector critical technologies, i.e. the operation at 50 mK
thermal bath, the threshold energy at 20 keV and the reproducibility of the
thermal conductance between the suspended absorber and the thermal bath. This
detector will be integrated and tested in our cryogenic setup at INAF/IAPS, and
then delivered to SRON for the integration in the X-IFU Focal Plane Assemby
(FPA) DM.
In this paper we report the status of the CryoAC DM development, showing the
main result obtained with the last developed prototype, namely AC-S9. This is a
DM-like sample, which we have preliminary integrated and tested before
performing the final etching process to suspend the silicon absorber. The
results are promising for the DM, since despite the limitations due to the
absence of the final etching (high thermal capacity, high thermal conductance,
partial TES surface coverage), we have been able to operate the detector with
TB = 50 mK and to detect 6 keV photons, thus having a low energy threshold
fully compatible with our requirement (20 keV).