Normalized to: Voellmer, G.
[1]
oai:arXiv.org:1403.1652 [pdf] - 1208233
Variable-delay Polarization Modulators for Cryogenic Millimeter-wave
Applications
Chuss, David T.;
Eimer, Joseph R.;
Fixsen, Dale J.;
Hinderks, James;
Kogut, Alan J.;
Lazear, Justin;
Mirel, Paul;
Switzer, Eric;
Voellmer, George M.;
Wollack, Edward J.
Submitted: 2014-03-06, last modified: 2014-05-28
We describe the design, construction, and initial validation of the
variable-delay polarization modulator (VPM) designed for the PIPER cosmic
microwave background polarimeter. The VPM modulates between linear and circular
polarization by introducing a variable phase delay between orthogonal linear
polarizations. Each VPM has a diameter of 39 cm and is engineered to operate in
a cryogenic environment (1.5 K). We describe the mechanical design and
performance of the kinematic double-blade flexure and drive mechanism along
with the construction of the high precision wire grid polarizers.
[2]
oai:arXiv.org:1303.5460 [pdf] - 800109
A waveguide-coupled thermally-isolated radiometric source
Submitted: 2013-03-21
The design and validation of a dual polarization source for waveguide-coupled
millimeter and sub-millimeter wave cryogenic sensors is presented. The thermal
source is a waveguide mounted absorbing conical dielectric taper. The absorber
is thermally isolated with a kinematic suspension that allows the guide to be
heat sunk to the lowest bath temperature of the cryogenic system. This approach
enables the thermal emission from the metallic waveguide walls to be
subdominant to that from the source. The use of low thermal conductivity Kevlar
threads for the kinematic mount effectively decouples the absorber from the
sensor cold stage. Hence, the absorber can be heated to significantly higher
temperatures than the sensor with negligible conductive loading. The kinematic
suspension provides high mechanical repeatability and reliability with thermal
cycling. A 33-50 GHz blackbody source demonstrates an emissivity of 0.999 over
the full waveguide band where the dominant deviation from unity arrises from
the waveguide ohmic loss. The observed thermal time constant of the source is
40 s when the absorber temperature is 15 K. The specific heat of the lossy
dielectric MF-117 is well approximated by $C_v(T)=0.12\,T\,^{2.06}$ mJ g$^{-1}$
K$^{-1}$ between 3.5 K and 15 K.
[3]
oai:arXiv.org:1005.5123 [pdf] - 1032799
The Herschel-SPIRE instrument and its in-flight performance
Griffin, M. J.;
Abergel, A.;
Abreu, A.;
Ade, P. A. R.;
André, P.;
Augueres, J. -L.;
Babbedge, T.;
Bae, Y.;
Baillie, T.;
Baluteau, J. -P.;
Barlow, M. J.;
Bendo, G.;
Benielli, D.;
Bock, J. J.;
Bonhomme, P.;
Brisbin, D.;
Brockley-Blatt, C.;
Caldwell, M.;
Cara, C.;
Castro-Rodriguez, N.;
Cerulli, R.;
Chanial, P.;
Chen, S.;
Clark, E.;
Clements, D. L.;
Clerc, L.;
Coker, J.;
Communal, D.;
Conversi, L.;
Cox, P.;
Crumb, D.;
Cunningham, C.;
Daly, F.;
Davis, G. R.;
De Antoni, P.;
Delderfield, J.;
Devin, N.;
Di Giorgio, A.;
Didschuns, I.;
Dohlen, K.;
Donati, M.;
Dowell, A.;
Dowell, C. D.;
Duband, L.;
Dumaye, L.;
Emery, R. J.;
Ferlet, M.;
Ferrand, D.;
Fontignie, J.;
Fox, M.;
Franceschini, A.;
Frerking, M.;
Fulton, T.;
Garcia, J.;
Gastaud, R.;
Gear, W. K.;
Glenn, J.;
Goizel, A.;
Griffin, D. K.;
Grundy, T.;
Guest, S.;
Guillemet, L.;
Hargrave, P. C.;
Harwit, M.;
Hastings, P.;
Hatziminaoglou, E.;
Herman, M.;
Hinde, B.;
Hristov, V.;
Huang, M.;
Imhof, P.;
Isaak, K. J.;
Israelsson, U.;
Ivison, R. J.;
Jennings, D.;
Kiernan, B.;
King, K. J.;
Lange, A. E.;
Latter, W.;
Laurent, G.;
Laurent, P.;
Leeks, S. J.;
Lellouch, E.;
Levenson, L.;
Li, B.;
Li, J.;
Lilienthal, J.;
Lim, T.;
Liu, J.;
Lu, N.;
Madden, S.;
Mainetti, G.;
Marliani, P.;
McKay, D.;
Mercier, K.;
Molinari, S.;
Morris, H.;
Moseley, H.;
Mulder, J.;
Mur, M.;
Naylor, D. A.;
Nguyen, H.;
O'Halloran, B.;
Oliver, S.;
Olofsson, G.;
Olofsson, H. -G.;
Orfei, R.;
Page, M. J.;
Pain, I.;
Panuzzo, P.;
Papageorgiou, A.;
Parks, G.;
Parr-Burman, P.;
Pearce, A.;
Pearson, C.;
Pérez-Fournon, I.;
Pinsard, F.;
Pisano, G.;
Podosek, J.;
Pohlen, M.;
Polehampton, E. T.;
Pouliquen, D.;
Rigopoulou, D.;
Rizzo, D.;
Roseboom, I. G.;
Roussel, H.;
Rowan-Robinson, M.;
Rownd, B.;
Saraceno, P.;
Sauvage, M.;
Savage, R.;
Savini, G.;
Sawyer, E.;
Scharmberg, C.;
Schmitt, D.;
Schneider, N.;
Schulz, B.;
Schwartz, A.;
Shafer, R.;
Shupe, D. L.;
Sibthorpe, B.;
Sidher, S.;
Smith, A.;
Smith, A. J.;
Smith, D.;
Spencer, L.;
Stobie, B.;
Sudiwala, R.;
Sukhatme, K.;
Surace, C.;
Stevens, J. A.;
Swinyard, B. M.;
Trichas, M.;
Tourette, T.;
Triou, H.;
Tseng, S.;
Tucker, C.;
Turner, A.;
Vaccari, M.;
Valtchanov, I.;
Vigroux, L.;
Virique, E.;
Voellmer, G.;
Walker, H.;
Ward, R.;
Waskett, T.;
Weilert, M.;
Wesson, R.;
White, G. J.;
Whitehouse, N.;
Wilson, C. D.;
Winter, B.;
Woodcraft, A. L.;
Wright, G. S.;
Xu, C. K.;
Zavagno, A.;
Zemcov, M.;
Zhang, L.;
Zonca, E.
Submitted: 2010-05-27
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space
Observatory`s submillimetre camera and spectrometer. It contains a three-band
imaging photometer operating at 250, 350 and 500 microns, and an imaging
Fourier Transform Spectrometer (FTS) which covers simultaneously its whole
operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are
arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a
field of view of 4' x 8', observed simultaneously in the three spectral bands.
Its main operating mode is scan-mapping, whereby the field of view is scanned
across the sky to achieve full spatial sampling and to cover large areas if
desired. The spectrometer has an approximately circular field of view with a
diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25
GHz by changing the stroke length of the FTS scan mirror. Its main operating
mode involves a fixed telescope pointing with multiple scans of the FTS mirror
to acquire spectral data. For extended source measurements, multiple position
offsets are implemented by means of an internal beam steering mirror to achieve
the desired spatial sampling and by rastering of the telescope pointing to map
areas larger than the field of view. The SPIRE instrument consists of a cold
focal plane unit located inside the Herschel cryostat and warm electronics
units, located on the spacecraft Service Module, for instrument control and
data handling. Science data are transmitted to Earth with no on-board data
compression, and processed by automatic pipelines to produce calibrated science
products. The in-flight performance of the instrument matches or exceeds
predictions based on pre-launch testing and modelling: the photometer
sensitivity is comparable to or slightly better than estimated pre-launch, and
the spectrometer sensitivity is also better by a factor of 1.5-2.
[4]
oai:arXiv.org:0803.3759 [pdf] - 11227
The Hertz/VPM polarimeter: Design and first light observations
Krejny, Megan;
Chuss, David;
d'Aubigny, Christian Drouet;
Golish, Dathon;
Houde, Martin;
Hui, Howard;
Kulesa, Craig;
Loewenstein, Robert F.;
Moseley, S. Harvey;
Novak, Giles;
Voellmer, George;
Walker, Chris;
Wollack, Ed
Submitted: 2008-03-26
We present first results of Hertz/VPM, the first submillimeter polarimeter
employing the dual Variable-delay Polarization Modulator (dual-VPM). This
device differs from previously used polarization modulators in that it operates
in translation rather than mechanical rotation. We discuss the basic theory
behind this device, and its potential advantages over the commonly used half
wave plate (HWP). The dual-VPM was tested both at the Submillimeter Telescope
Observatory (SMTO) and in the lab. In each case we present a detailed
description of the setup. We discovered nonideal behavior in the system. This
is at least in part due to properties of the VPM wire grids (diameter, spacing)
employed in our experiment. Despite this, we found that the dual-VPM system is
robust, operating with high efficiency and low instrumental polarization. This
device is well suited for air and space-borne applications.