Normalized to: Vivès, S.
[1]
oai:arXiv.org:1805.09067 [pdf] - 1688202
POLLUX: a UV spectropolarimeter for the LUVOIR space telescope project
Muslimov, Eduard;
Bouret, Jean-Claude;
Neiner, Coralie;
Ariste, Arturo López;
Ferrari, Marc;
Vivès, Sébastien;
Hugot, Emmanuel;
Grange, Robert;
Lombardo, Simona;
Lopes, Louise;
Costerate, Josiane;
Brachet, Frank
Submitted: 2018-05-23
The present paper describes the current baseline optical design of POLLUX, a
high-resolution spectropolarimeter for the future LUVOIR mission. The
instrument will operate in the ultraviolet (UV) domain from 90 to 390 nm in
both spectropolarimetric and pure spectroscopic modes. The working range is
split between 3 channels -- far (90-124.5 nm), medium (118.5-195 nm) and near
(195-390 nm) UV. Each of the channels is composed of a polarimeter followed by
an echelle spectrograph consisting of a classical off-axis paraboloid
collimator, echelle grating with a high grooves frequency and a cross-disperser
grating operating also as a camera. The latter component integrates some
advanced technologies: it is a blazed grating with a complex grooves pattern
formed by holographic recording, which is manufactured on a freeform surface.
One of the key features underlying the current design is the large spectral
length of each order ~6 nm, which allows to record wide spectral lines without
any discontinuities. The modelling results show that the optical design will
provide the required spectral resolving power higher than R ~ 120,000 over the
entire working range for a point source object with angular size of 30 mas. It
is also shown that with the 15-m primary mirror of the LUVOIR telescope the
instrument will provide an effective collecting area up to 38 569 cm 2. Such a
performance will allow to perform a number of groundbreaking scientific
observations. Finally, the future work and the technological risks of the
design are discussed in details.
[2]
oai:arXiv.org:physics/0512002 [pdf] - 1456483
An original image slicer designed for Integral Field Spectroscopy with
NIRSpec/JSWT
Submitted: 2005-12-01
Integral Field Spectroscopy (IFS) provides a spectrum simultaneously for each
spatial sample of an extended, two-dimensional field. It consists of an
Integral Field Unit (IFU) which slices and re-arranges the initial field along
the entrance slit of a spectrograph. This article presents an original design
of IFU based on the advanced image slicer concept. To reduce optical
aberrations, pupil and slit mirrors are disposed in a fan-shaped configuration
that means that angles between incident and reflected beams on each elements
are minimized. The fan-shaped image slicer improves image quality in terms of
wavefront error by a factor 2 comparing with classical image slicer and,
furthermore it guaranties a negligible level of differential aberration in the
field. As an exemple, we are presenting the design LAM used for its proposal at
the NIRSPEC/IFU invitation of tender.
[3]
oai:arXiv.org:physics/0510174 [pdf] - 1456482
Modeling a Slicer Mirror Using Zemax User-Defined Surface
Submitted: 2005-10-19
A slicer mirror is a complex surface composed by many tilted and decentered
mirrors sub-surfaces. The major difficulty to model such a complex surface is
the large number of parameters used to define it. The Zemax's
multi-configuration mode is usually used to specify each parameters (tilts,
curvatures, decenters) for each mirror sub-surface which are then considered
independently. Otherwise making use of the User-Defined Surface (UDS-DLL) Zemax
capability, we are able to consider the set of sub-surfaces as a whole surface.
In this paper, we present such a UDS-DLL tool comparing its performance with
those of the classical multi-configuration mode. In particular, we explore the
use of UDS-DLL to investigate the cross-talk due to the diffraction on the
slicer array mirrors which has been a burden task when using
multi-configuration mode.