Normalized to: Vissers, M.
[1]
oai:arXiv.org:2007.00638 [pdf] - 2126373
A three-wave mixing kinetic inductance traveling-wave amplifier with
near-quantum-limited noise performance
Submitted: 2020-07-01
We present a theoretical model and experimental characterization of a
microwave kinetic inductance traveling-wave amplifier (KIT), whose noise
performance, measured by a shot noise thermometer, approaches the quantum
limit. Biased with a dc current, the KIT operates in a three-wave mixing
fashion, thereby reducing by several orders of magnitude the power of the
microwave pump tone compared to conventional four-wave mixing KIT devices. It
is built in an artificial transmission line intrinsically matched to 50 Ohms,
whose dispersion allows for a controlled amplification bandwidth. We
experimentally measure $17.6^{+1.1}_{-1.4}$ dB of gain across a 2 GHz
bandwidth, with an input 1 dB compression power of -63 dBm within that
bandwidth, in qualitative agreement with theory. Using the KIT as the first
amplifier in an amplification chain, we measure a system-added noise of
$0.61\pm0.08$ K between 3.5 and 5.5 GHz, about one eighth the noise obtained
when using only a representative classical amplifier. The KIT contribution to
this added noise is estimated to be $0.2\pm0.1$ K, consistent with the quantum
limit on amplifier added noise. This device is therefore suitable to read large
arrays of microwave kinetic inductance detectors or thousands of
superconducting qubits.
[2]
oai:arXiv.org:1908.10451 [pdf] - 2072556
Sensitivity of the Prime-Cam Instrument on the CCAT-prime Telescope
Choi, Steve K.;
Austermann, Jason;
Basu, Kaustuv;
Battaglia, Nicholas;
Bertoldi, Frank;
Chung, Dongwoo T.;
Cothard, Nicholas F.;
Duff, Shannon;
Duell, Cody J.;
Gallardo, Patricio A.;
Gao, Jiansong;
Herter, Terry;
Hubmayr, Johannes;
Niemack, Michael D.;
Nikola, Thomas;
Riechers, Dominik;
Rossi, Kayla;
Stacey, Gordon J.;
Stevens, Jason R.;
Vavagiakis, Eve M.;
Vissers, Michael;
Walker, Samantha
Submitted: 2019-08-27, last modified: 2020-03-31
CCAT-prime is a new 6 m crossed Dragone telescope designed to characterize
the Cosmic Microwave Background (CMB) polarization and foregrounds, measure the
Sunyaev-Zel'dovich effects of galaxy clusters, map the [CII] emission intensity
from the Epoch of Reionization (EoR), and monitor accretion luminosity over
multi-year timescales of hundreds of protostars in the Milky Way. CCAT-prime
will make observations from a 5,600 m altitude site on Cerro Chajnantor in the
Atacama Desert of northern Chile. The novel optical design of the telescope
combined with high surface accuracy ($<$10 $\mu$m) mirrors and the exceptional
atmospheric conditions of the site will enable sensitive broadband,
polarimetric, and spectroscopic surveys at sub-mm to mm wavelengths. Prime-Cam,
the first light instrument for CCAT-prime, consists of a 1.8 m diameter
cryostat that can house seven individual instrument modules. Each instrument
module, optimized for a specific science goal, will use state-of-the-art
kinetic inductance detector (KID) arrays operated at $\sim$100 mK, and
Fabry-Perot interferometers (FPI) for the EoR science. Prime-Cam will be
commissioned with staged deployments to populate the seven instrument modules.
The full instrument will consist of 60,000 polarimetric KIDs at a combination
of 220/280/350/410 GHz, 31,000 KIDS at 250/360 GHz coupled with FPIs, and
21,000 polarimetric KIDs at 850 GHz. Prime-Cam is currently being built, and
the CCAT-prime telescope is designed and under construction by Vertex
Antennentechnik GmbH to achieve first light in 2021. CCAT-prime is also a
potential telescope platform for the future CMB Stage-IV observations.
[3]
oai:arXiv.org:1912.00860 [pdf] - 2065329
Characterization of Transition Edge Sensors for the Simons Observatory
Stevens, Jason R.;
Cothard, Nicholas F.;
Vavagiakis, Eve M.;
Ali, Aamir;
Arnold, Kam;
Austermann, Jason E.;
Choi, Steve K.;
Dober, Bradley J.;
Duell, Cody;
Duff, Shannon M.;
Hilton, Gene C.;
Ho, Shuay-Pwu Patty;
Hoang, Thuong D.;
Hubmayr, Johannes;
Lee, Adrian T.;
Mangu, Aashrita;
Nati, Federico;
Niemack, Michael D.;
Raum, Christopher;
Renzullo, Mario;
Salatino, Maria;
Sasse, Trevor;
Simon, Sara M.;
Staggs, Suzanne;
Suzuki, Aritoki;
Truitt, Patrick;
Ullom, Joel;
Vivalda, John;
Vissers, Michael R.;
Walker, Samantha;
Westbrook, Benjamin;
Wollack, Edward J.;
Xu, Zhilei;
Yohannes, Daniel
Submitted: 2019-12-02, last modified: 2020-01-21
The Simons Observatory is building both large (6 m) and small (0.5 m)
aperture telescopes in the Atacama desert in Chile to observe the cosmic
microwave background (CMB) radiation with unprecedented sensitivity. Simons
Observatory telescopes in total will use over 60,000 transition edge sensor
(TES) detectors spanning center frequencies between 27 and 285 GHz and
operating near 100 mK. TES devices have been fabricated for the Simons
Observatory by NIST, Berkeley, and HYPRES/SeeQC corporation. Iterations of
these devices have been tested cryogenically in order to inform the fabrication
of further devices, which will culminate in the final TES designs to be
deployed in the field. The detailed design specifications have been
independently iterated at each fabrication facility for particular detector
frequencies.
We present test results for prototype devices, with emphasis on NIST high
frequency detectors. A dilution refrigerator was used to achieve the required
temperatures. Measurements were made both with 4-lead resistance measurements
and with a time domain Superconducting Quantum Interference Device (SQUID)
multiplexer system. The SQUID readout measurements include analysis of current
vs voltage (IV) curves at various temperatures, square wave bias step
measurements, and detector noise measurements. Normal resistance,
superconducting critical temperature, saturation power, thermal and natural
time constants, and thermal properties of the devices are extracted from these
measurements.
[4]
oai:arXiv.org:2001.01724 [pdf] - 2026608
Updated design of the CMB polarization experiment satellite LiteBIRD
Sugai, H.;
Ade, P. A. R.;
Akiba, Y.;
Alonso, D.;
Arnold, K.;
Aumont, J.;
Austermann, J.;
Baccigalupi, C.;
Banday, A. J.;
Banerji, R.;
Barreiro, R. B.;
Basak, S.;
Beall, J.;
Beckman, S.;
Bersanelli, M.;
Borrill, J.;
Boulanger, F.;
Brown, M. L.;
Bucher, M.;
Buzzelli, A.;
Calabrese, E.;
Casas, F. J.;
Challinor, A.;
Chan, V.;
Chinone, Y.;
Cliche, J. -F.;
Columbro, F.;
Cukierman, A.;
Curtis, D.;
Danto, P.;
de Bernardis, P.;
de Haan, T.;
De Petris, M.;
Dickinson, C.;
Dobbs, M.;
Dotani, T.;
Duband, L.;
Ducout, A.;
Duff, S.;
Duivenvoorden, A.;
Duval, J. -M.;
Ebisawa, K.;
Elleflot, T.;
Enokida, H.;
Eriksen, H. K.;
Errard, J.;
Essinger-Hileman, T.;
Finelli, F.;
Flauger, R.;
Franceschet, C.;
Fuskeland, U.;
Ganga, K.;
Gao, J. -R.;
Génova-Santos, R.;
Ghigna, T.;
Gomez, A.;
Gradziel, M. L.;
Grain, J.;
Grupp, F.;
Gruppuso, A.;
Gudmundsson, J. E.;
Halverson, N. W.;
Hargrave, P.;
Hasebe, T.;
Hasegawa, M.;
Hattori, M.;
Hazumi, M.;
Henrot-Versille, S.;
Herranz, D.;
Hill, C.;
Hilton, G.;
Hirota, Y.;
Hivon, E.;
Hlozek, R.;
Hoang, D. -T.;
Hubmayr, J.;
Ichiki, K.;
Iida, T.;
Imada, H.;
Ishimura, K.;
Ishino, H.;
Jaehnig, G. C.;
Jones, M.;
Kaga, T.;
Kashima, S.;
Kataoka, Y.;
Katayama, N.;
Kawasaki, T.;
Keskitalo, R.;
Kibayashi, A.;
Kikuchi, T.;
Kimura, K.;
Kisner, T.;
Kobayashi, Y.;
Kogiso, N.;
Kogut, A.;
Kohri, K.;
Komatsu, E.;
Komatsu, K.;
Konishi, K.;
Krachmalnicoff, N.;
Kuo, C. L.;
Kurinsky, N.;
Kushino, A.;
Kuwata-Gonokami, M.;
Lamagna, L.;
Lattanzi, M.;
Lee, A. T.;
Linder, E.;
Maffei, B.;
Maino, D.;
Maki, M.;
Mangilli, A.;
Martínez-González, E.;
Masi, S.;
Mathon, R.;
Matsumura, T.;
Mennella, A.;
Migliaccio, M.;
Minami, Y.;
Mistuda, K.;
Molinari, D.;
Montier, L.;
Morgante, G.;
Mot, B.;
Murata, Y.;
Murphy, J. A.;
Nagai, M.;
Nagata, R.;
Nakamura, S.;
Namikawa, T.;
Natoli, P.;
Nerva, S.;
Nishibori, T.;
Nishino, H.;
Nomura, Y.;
Noviello, F.;
O'Sullivan, C.;
Ochi, H.;
Ogawa, H.;
Ogawa, H.;
Ohsaki, H.;
Ohta, I.;
Okada, N.;
Okada, N.;
Pagano, L.;
Paiella, A.;
Paoletti, D.;
Patanchon, G.;
Piacentini, F.;
Pisano, G.;
Polenta, G.;
Poletti, D.;
Prouvé, T.;
Puglisi, G.;
Rambaud, D.;
Raum, C.;
Realini, S.;
Remazeilles, M.;
Roudil, G.;
Rubiño-Martín, J. A.;
Russell, M.;
Sakurai, H.;
Sakurai, Y.;
Sandri, M.;
Savini, G.;
Scott, D.;
Sekimoto, Y.;
Sherwin, B. D.;
Shinozaki, K.;
Shiraishi, M.;
Shirron, P.;
Signorelli, G.;
Smecher, G.;
Spizzi, P.;
Stever, S. L.;
Stompor, R.;
Sugiyama, S.;
Suzuki, A.;
Suzuki, J.;
Switzer, E.;
Takaku, R.;
Takakura, H.;
Takakura, S.;
Takeda, Y.;
Taylor, A.;
Taylor, E.;
Terao, Y.;
Thompson, K. L.;
Thorne, B.;
Tomasi, M.;
Tomida, H.;
Trappe, N.;
Tristram, M.;
Tsuji, M.;
Tsujimoto, M.;
Tucker, C.;
Ullom, J.;
Uozumi, S.;
Utsunomiya, S.;
Van Lanen, J.;
Vermeulen, G.;
Vielva, P.;
Villa, F.;
Vissers, M.;
Vittorio, N.;
Voisin, F.;
Walker, I.;
Watanabe, N.;
Wehus, I.;
Weller, J.;
Westbrook, B.;
Winter, B.;
Wollack, E.;
Yamamoto, R.;
Yamasaki, N. Y.;
Yanagisawa, M.;
Yoshida, T.;
Yumoto, J.;
Zannoni, M.;
Zonca, A.
Submitted: 2020-01-06
Recent developments of transition-edge sensors (TESs), based on extensive
experience in ground-based experiments, have been making the sensor techniques
mature enough for their application on future satellite CMB polarization
experiments. LiteBIRD is in the most advanced phase among such future
satellites, targeting its launch in Japanese Fiscal Year 2027 (2027FY) with
JAXA's H3 rocket. It will accommodate more than 4000 TESs in focal planes of
reflective low-frequency and refractive medium-and-high-frequency telescopes in
order to detect a signature imprinted on the cosmic microwave background (CMB)
by the primordial gravitational waves predicted in cosmic inflation. The total
wide frequency coverage between 34GHz and 448GHz enables us to extract such
weak spiral polarization patterns through the precise subtraction of our
Galaxy's foreground emission by using spectral differences among CMB and
foreground signals. Telescopes are cooled down to 5Kelvin for suppressing
thermal noise and contain polarization modulators with transmissive half-wave
plates at individual apertures for separating sky polarization signals from
artificial polarization and for mitigating from instrumental 1/f noise. Passive
cooling by using V-grooves supports active cooling with mechanical coolers as
well as adiabatic demagnetization refrigerators. Sky observations from the
second Sun-Earth Lagrangian point, L2, are planned for three years. An
international collaboration between Japan, USA, Canada, and Europe is sharing
various roles. In May 2019, the Institute of Space and Astronautical Science
(ISAS), JAXA selected LiteBIRD as the strategic large mission No. 2.
[5]
oai:arXiv.org:1909.11569 [pdf] - 2038283
Demonstration of 220/280 GHz Multichroic Feedhorn-Coupled TES
Polarimeter
Walker, Samantha;
Sierra, Carlos E.;
Austermann, Jason E.;
Beall, James A.;
Becker, Daniel T.;
Dober, Bradley J.;
Duff, Shannon M.;
Hilton, Gene C.;
Hubmayr, Johannes;
Van Lanen, Jeffrey L.;
McMahon, Jeffrey J.;
Simon, Sara M.;
Ullom, Joel N.;
Vissers, Michael R.
Submitted: 2019-09-25, last modified: 2019-12-26
We describe the design and measurement of feedhorn-coupled, transition-edge
sensor (TES) polarimeters with two passbands centered at 220 GHz and 280 GHz,
intended for observations of the cosmic microwave background. Each pixel
couples polarized light in two linear polarizations by use of a planar
orthomode transducer and senses power via four TES bolometers, one for each
band in each linear polarization. Previous designs of this detector
architecture incorporated passbands from 27 GHz to 220 GHz; we now demonstrate
this technology at frequencies up to 315 GHz. Observational passbands are
defined with an on-chip diplexer, and Fourier-transform-spectrometer
measurements are in excellent agreement with simulations. We find coupling from
feedhorn to TES bolometer using a cryogenic, temperature-controlled thermal
source. We determine the optical efficiency of our device is $\eta$ =
77%$\pm$6% (75%$\pm$5%) for 220 (280) GHz, relative to the designed passband
shapes. Lastly, we compare two power-termination schemes commonly used in
wide-bandwidth millimeter-wave polarimeters and find equal performance in terms
of optical efficiency and passband shape.
[6]
oai:arXiv.org:1912.02902 [pdf] - 2065335
Characterization of aliased noise in the Advanced ACTPol receiver
Gallardo, Patricio A.;
Niemack, Michael D.;
Austermann, Jason E.;
Beall, James A.;
Cothard, Nick F.;
Duell, Cody J.;
Duff, Shannon M.;
Henderson, Shawn W.;
Hilton, Gene C.;
Ho, Shuay-Pwu Patty;
Hubmayr, Johannes;
Reintsema, Carl D.;
Salatino, Maria;
Ullom, Joel;
Van Lanen, Jeff;
Vissers, Michael;
Wollack, Edward J.
Submitted: 2019-12-05
Advanced ACTPol is the second generation polarization-sensitive upgrade to
the $6\, \rm m$ aperture Atacama Cosmology Telescope (ACT), which increased
detector count and frequency coverage compared to the previous ACTPol receiver.
Advanced ACTPol utilizes a new two-stage time-division multiplexing readout
architecture based on superconducting quantum interference devices (SQUIDs) to
achieve a multiplexing factor as high as 64 (rows), fielding a 2,012 detector
camera at 150/220 GHz and two 90/150 GHz cameras containing 1,716 detectors
each. In a time domain system, aliasing introduces noise to the readout. In
this work we present a figure of merit to measure this noise contribution and
present measurements of the aliased noise fraction of the Advanced ACTPol
receiver as deployed.
[7]
oai:arXiv.org:1909.02587 [pdf] - 1956586
The CCAT-Prime Submillimeter Observatory
Aravena, Manuel;
Austermann, Jason;
Basu, Kaustuv;
Battaglia, Nicholas;
Beringue, Benjamin;
Bertoldi, Frank;
Bond, J. Richard;
Breysse, Patrick;
Bustos, Ricardo;
Chapman, Scott;
Choi, Steve;
Chung, Dongwoo;
Cothard, Nicholas;
Dober, Bradley;
Duell, Cody;
Duff, Shannon;
Dunner, Rolando;
Erler, Jens;
Fich, Michel;
Fissel, Laura;
Foreman, Simon;
Gallardo, Patricio;
Gao, Jiansong;
Giovanelli, Riccardo;
Graf, Urs;
Haynes, Martha;
Herter, Terry;
Hilton, Gene;
Hlozek, Renee;
Hubmayr, Johannes;
Johnstone, Doug;
Keating, Laura;
Komatsu, Eiichiro;
Magnelli, Benjamin;
Mauskopf, Phil;
McMahon, Jeffrey;
Meerburg, P. Daniel;
Meyers, Joel;
Murray, Norm;
Niemack, Michael;
Nikola, Thomas;
Nolta, Michael;
Parshley, Stephen;
Puddu, Roberto;
Riechers, Dominik;
Rosolowsky, Erik;
Simon, Sara;
Stacey, Gordon;
Stevens, Jason;
Stutzki, Juergen;
Van Engelen, Alexander;
Vavagiakis, Eve;
Viero, Marco;
Vissers, Michael;
Walker, Samantha;
Zou, Bugao
Submitted: 2019-09-05
The Cerro Chajnantor Atacama Telescope-prime (CCAT-prime) is a new 6-m,
off-axis, low-emissivity, large field-of-view submillimeter telescope scheduled
for first light in the last quarter of 2021. In summary, (a) CCAT-prime
uniquely combines a large field-of-view (up to 8-deg), low emissivity telescope
(< 2%) and excellent atmospheric transmission (5600-m site) to achieve
unprecedented survey capability in the submillimeter. (b) Over five years,
CCAT-prime first generation science will address the physics of star formation,
galaxy evolution, and galaxy cluster formation; probe the re-ionization of the
Universe; improve constraints on new particle species; and provide for improved
removal of dust foregrounds to aid the search for primordial gravitational
waves. (c) The Observatory is being built with non-federal funds (~ \$40M in
private and international investments). Public funding is needed for
instrumentation (~ \$8M) and operations (\$1-2M/yr). In return, the community
will be able to participate in survey planning and gain access to curated data
sets. (d) For second generation science, CCAT-prime will be uniquely positioned
to contribute high-frequency capabilities to the next generation of CMB surveys
in partnership with the CMB-S4 and/or the Simons Observatory projects or
revolutionize wide-field, sub-millimetter line intensity mapping surveys.
[8]
oai:arXiv.org:1907.08284 [pdf] - 1976842
The Simons Observatory: Astro2020 Decadal Project Whitepaper
The Simons Observatory Collaboration;
Abitbol, Maximilian H.;
Adachi, Shunsuke;
Ade, Peter;
Aguirre, James;
Ahmed, Zeeshan;
Aiola, Simone;
Ali, Aamir;
Alonso, David;
Alvarez, Marcelo A.;
Arnold, Kam;
Ashton, Peter;
Atkins, Zachary;
Austermann, Jason;
Awan, Humna;
Baccigalupi, Carlo;
Baildon, Taylor;
Lizancos, Anton Baleato;
Barron, Darcy;
Battaglia, Nick;
Battye, Richard;
Baxter, Eric;
Bazarko, Andrew;
Beall, James A.;
Bean, Rachel;
Beck, Dominic;
Beckman, Shawn;
Beringue, Benjamin;
Bhandarkar, Tanay;
Bhimani, Sanah;
Bianchini, Federico;
Boada, Steven;
Boettger, David;
Bolliet, Boris;
Bond, J. Richard;
Borrill, Julian;
Brown, Michael L.;
Bruno, Sarah Marie;
Bryan, Sean;
Calabrese, Erminia;
Calafut, Victoria;
Calisse, Paolo;
Carron, Julien;
Carl, Fred. M;
Cayuso, Juan;
Challinor, Anthony;
Chesmore, Grace;
Chinone, Yuji;
Chluba, Jens;
Cho, Hsiao-Mei Sherry;
Choi, Steve;
Clark, Susan;
Clarke, Philip;
Contaldi, Carlo;
Coppi, Gabriele;
Cothard, Nicholas F.;
Coughlin, Kevin;
Coulton, Will;
Crichton, Devin;
Crowley, Kevin D.;
Crowley, Kevin T.;
Cukierman, Ari;
D'Ewart, John M.;
Dünner, Rolando;
de Haan, Tijmen;
Devlin, Mark;
Dicker, Simon;
Dober, Bradley;
Duell, Cody J.;
Duff, Shannon;
Duivenvoorden, Adri;
Dunkley, Jo;
Bouhargani, Hamza El;
Errard, Josquin;
Fabbian, Giulio;
Feeney, Stephen;
Fergusson, James;
Ferraro, Simone;
Fluxà, Pedro;
Freese, Katherine;
Frisch, Josef C.;
Frolov, Andrei;
Fuller, George;
Galitzki, Nicholas;
Gallardo, Patricio A.;
Ghersi, Jose Tomas Galvez;
Gao, Jiansong;
Gawiser, Eric;
Gerbino, Martina;
Gluscevic, Vera;
Goeckner-Wald, Neil;
Golec, Joseph;
Gordon, Sam;
Gralla, Megan;
Green, Daniel;
Grigorian, Arpi;
Groh, John;
Groppi, Chris;
Guan, Yilun;
Gudmundsson, Jon E.;
Halpern, Mark;
Han, Dongwon;
Hargrave, Peter;
Harrington, Kathleen;
Hasegawa, Masaya;
Hasselfield, Matthew;
Hattori, Makoto;
Haynes, Victor;
Hazumi, Masashi;
Healy, Erin;
Henderson, Shawn W.;
Hensley, Brandon;
Hervias-Caimapo, Carlos;
Hill, Charles A.;
Hill, J. Colin;
Hilton, Gene;
Hilton, Matt;
Hincks, Adam D.;
Hinshaw, Gary;
Hložek, Renée;
Ho, Shirley;
Ho, Shuay-Pwu Patty;
Hoang, Thuong D.;
Hoh, Jonathan;
Hotinli, Selim C.;
Huang, Zhiqi;
Hubmayr, Johannes;
Huffenberger, Kevin;
Hughes, John P.;
Ijjas, Anna;
Ikape, Margaret;
Irwin, Kent;
Jaffe, Andrew H.;
Jain, Bhuvnesh;
Jeong, Oliver;
Johnson, Matthew;
Kaneko, Daisuke;
Karpel, Ethan D.;
Katayama, Nobuhiko;
Keating, Brian;
Keskitalo, Reijo;
Kisner, Theodore;
Kiuchi, Kenji;
Klein, Jeff;
Knowles, Kenda;
Kofman, Anna;
Koopman, Brian;
Kosowsky, Arthur;
Krachmalnicoff, Nicoletta;
Kusaka, Akito;
LaPlante, Phil;
Lashner, Jacob;
Lee, Adrian;
Lee, Eunseong;
Lewis, Antony;
Li, Yaqiong;
Li, Zack;
Limon, Michele;
Linder, Eric;
Liu, Jia;
Lopez-Caraballo, Carlos;
Louis, Thibaut;
Lungu, Marius;
Madhavacheril, Mathew;
Mak, Daisy;
Maldonado, Felipe;
Mani, Hamdi;
Mates, Ben;
Matsuda, Frederick;
Maurin, Loïc;
Mauskopf, Phil;
May, Andrew;
McCallum, Nialh;
McCarrick, Heather;
McKenney, Chris;
McMahon, Jeff;
Meerburg, P. Daniel;
Mertens, James;
Meyers, Joel;
Miller, Amber;
Mirmelstein, Mark;
Moodley, Kavilan;
Moore, Jenna;
Munchmeyer, Moritz;
Munson, Charles;
Murata, Masaaki;
Naess, Sigurd;
Namikawa, Toshiya;
Nati, Federico;
Navaroli, Martin;
Newburgh, Laura;
Nguyen, Ho Nam;
Nicola, Andrina;
Niemack, Mike;
Nishino, Haruki;
Nishinomiya, Yume;
Orlowski-Scherer, John;
Pagano, Luca;
Partridge, Bruce;
Perrotta, Francesca;
Phakathi, Phumlani;
Piccirillo, Lucio;
Pierpaoli, Elena;
Pisano, Giampaolo;
Poletti, Davide;
Puddu, Roberto;
Puglisi, Giuseppe;
Raum, Chris;
Reichardt, Christian L.;
Remazeilles, Mathieu;
Rephaeli, Yoel;
Riechers, Dominik;
Rojas, Felipe;
Rotti, Aditya;
Roy, Anirban;
Sadeh, Sharon;
Sakurai, Yuki;
Salatino, Maria;
Rao, Mayuri Sathyanarayana;
Saunders, Lauren;
Schaan, Emmanuel;
Schmittfull, Marcel;
Sehgal, Neelima;
Seibert, Joseph;
Seljak, Uros;
Shellard, Paul;
Sherwin, Blake;
Shimon, Meir;
Sierra, Carlos;
Sievers, Jonathan;
Sifon, Cristobal;
Sikhosana, Precious;
Silva-Feaver, Maximiliano;
Simon, Sara M.;
Sinclair, Adrian;
Smith, Kendrick;
Sohn, Wuhyun;
Sonka, Rita;
Spergel, David;
Spisak, Jacob;
Staggs, Suzanne T.;
Stein, George;
Stevens, Jason R.;
Stompor, Radek;
Suzuki, Aritoki;
Tajima, Osamu;
Takakura, Satoru;
Teply, Grant;
Thomas, Daniel B.;
Thorne, Ben;
Thornton, Robert;
Trac, Hy;
Treu, Jesse;
Tsai, Calvin;
Tucker, Carole;
Ullom, Joel;
Vagnozzi, Sunny;
van Engelen, Alexander;
Van Lanen, Jeff;
Van Winkle, Daniel D.;
Vavagiakis, Eve M.;
Vergès, Clara;
Vissers, Michael;
Wagoner, Kasey;
Walker, Samantha;
Wang, Yuhan;
Ward, Jon;
Westbrook, Ben;
Whitehorn, Nathan;
Williams, Jason;
Williams, Joel;
Wollack, Edward;
Xu, Zhilei;
Yasini, Siavash;
Young, Edward;
Yu, Byeonghee;
Yu, Cyndia;
Zago, Fernando;
Zannoni, Mario;
Zhang, Hezi;
Zheng, Kaiwen;
Zhu, Ningfeng;
Zonca, Andrea
Submitted: 2019-07-16
The Simons Observatory (SO) is a ground-based cosmic microwave background
(CMB) experiment sited on Cerro Toco in the Atacama Desert in Chile that
promises to provide breakthrough discoveries in fundamental physics, cosmology,
and astrophysics. Supported by the Simons Foundation, the Heising-Simons
Foundation, and with contributions from collaborating institutions, SO will see
first light in 2021 and start a five year survey in 2022. SO has 287
collaborators from 12 countries and 53 institutions, including 85 students and
90 postdocs.
The SO experiment in its currently funded form ('SO-Nominal') consists of
three 0.4 m Small Aperture Telescopes (SATs) and one 6 m Large Aperture
Telescope (LAT). Optimized for minimizing systematic errors in polarization
measurements at large angular scales, the SATs will perform a deep,
degree-scale survey of 10% of the sky to search for the signature of primordial
gravitational waves. The LAT will survey 40% of the sky with arc-minute
resolution. These observations will measure (or limit) the sum of neutrino
masses, search for light relics, measure the early behavior of Dark Energy, and
refine our understanding of the intergalactic medium, clusters and the role of
feedback in galaxy formation.
With up to ten times the sensitivity and five times the angular resolution of
the Planck satellite, and roughly an order of magnitude increase in mapping
speed over currently operating ("Stage 3") experiments, SO will measure the CMB
temperature and polarization fluctuations to exquisite precision in six
frequency bands from 27 to 280 GHz. SO will rapidly advance CMB science while
informing the design of future observatories such as CMB-S4.
[9]
oai:arXiv.org:1808.07445 [pdf] - 1841339
The Simons Observatory: Science goals and forecasts
The Simons Observatory Collaboration;
Ade, Peter;
Aguirre, James;
Ahmed, Zeeshan;
Aiola, Simone;
Ali, Aamir;
Alonso, David;
Alvarez, Marcelo A.;
Arnold, Kam;
Ashton, Peter;
Austermann, Jason;
Awan, Humna;
Baccigalupi, Carlo;
Baildon, Taylor;
Barron, Darcy;
Battaglia, Nick;
Battye, Richard;
Baxter, Eric;
Bazarko, Andrew;
Beall, James A.;
Bean, Rachel;
Beck, Dominic;
Beckman, Shawn;
Beringue, Benjamin;
Bianchini, Federico;
Boada, Steven;
Boettger, David;
Bond, J. Richard;
Borrill, Julian;
Brown, Michael L.;
Bruno, Sarah Marie;
Bryan, Sean;
Calabrese, Erminia;
Calafut, Victoria;
Calisse, Paolo;
Carron, Julien;
Challinor, Anthony;
Chesmore, Grace;
Chinone, Yuji;
Chluba, Jens;
Cho, Hsiao-Mei Sherry;
Choi, Steve;
Coppi, Gabriele;
Cothard, Nicholas F.;
Coughlin, Kevin;
Crichton, Devin;
Crowley, Kevin D.;
Crowley, Kevin T.;
Cukierman, Ari;
D'Ewart, John M.;
Dünner, Rolando;
de Haan, Tijmen;
Devlin, Mark;
Dicker, Simon;
Didier, Joy;
Dobbs, Matt;
Dober, Bradley;
Duell, Cody J.;
Duff, Shannon;
Duivenvoorden, Adri;
Dunkley, Jo;
Dusatko, John;
Errard, Josquin;
Fabbian, Giulio;
Feeney, Stephen;
Ferraro, Simone;
Fluxà, Pedro;
Freese, Katherine;
Frisch, Josef C.;
Frolov, Andrei;
Fuller, George;
Fuzia, Brittany;
Galitzki, Nicholas;
Gallardo, Patricio A.;
Ghersi, Jose Tomas Galvez;
Gao, Jiansong;
Gawiser, Eric;
Gerbino, Martina;
Gluscevic, Vera;
Goeckner-Wald, Neil;
Golec, Joseph;
Gordon, Sam;
Gralla, Megan;
Green, Daniel;
Grigorian, Arpi;
Groh, John;
Groppi, Chris;
Guan, Yilun;
Gudmundsson, Jon E.;
Han, Dongwon;
Hargrave, Peter;
Hasegawa, Masaya;
Hasselfield, Matthew;
Hattori, Makoto;
Haynes, Victor;
Hazumi, Masashi;
He, Yizhou;
Healy, Erin;
Henderson, Shawn W.;
Hervias-Caimapo, Carlos;
Hill, Charles A.;
Hill, J. Colin;
Hilton, Gene;
Hilton, Matt;
Hincks, Adam D.;
Hinshaw, Gary;
Hložek, Renée;
Ho, Shirley;
Ho, Shuay-Pwu Patty;
Howe, Logan;
Huang, Zhiqi;
Hubmayr, Johannes;
Huffenberger, Kevin;
Hughes, John P.;
Ijjas, Anna;
Ikape, Margaret;
Irwin, Kent;
Jaffe, Andrew H.;
Jain, Bhuvnesh;
Jeong, Oliver;
Kaneko, Daisuke;
Karpel, Ethan D.;
Katayama, Nobuhiko;
Keating, Brian;
Kernasovskiy, Sarah S.;
Keskitalo, Reijo;
Kisner, Theodore;
Kiuchi, Kenji;
Klein, Jeff;
Knowles, Kenda;
Koopman, Brian;
Kosowsky, Arthur;
Krachmalnicoff, Nicoletta;
Kuenstner, Stephen E.;
Kuo, Chao-Lin;
Kusaka, Akito;
Lashner, Jacob;
Lee, Adrian;
Lee, Eunseong;
Leon, David;
Leung, Jason S. -Y.;
Lewis, Antony;
Li, Yaqiong;
Li, Zack;
Limon, Michele;
Linder, Eric;
Lopez-Caraballo, Carlos;
Louis, Thibaut;
Lowry, Lindsay;
Lungu, Marius;
Madhavacheril, Mathew;
Mak, Daisy;
Maldonado, Felipe;
Mani, Hamdi;
Mates, Ben;
Matsuda, Frederick;
Maurin, Loïc;
Mauskopf, Phil;
May, Andrew;
McCallum, Nialh;
McKenney, Chris;
McMahon, Jeff;
Meerburg, P. Daniel;
Meyers, Joel;
Miller, Amber;
Mirmelstein, Mark;
Moodley, Kavilan;
Munchmeyer, Moritz;
Munson, Charles;
Naess, Sigurd;
Nati, Federico;
Navaroli, Martin;
Newburgh, Laura;
Nguyen, Ho Nam;
Niemack, Michael;
Nishino, Haruki;
Orlowski-Scherer, John;
Page, Lyman;
Partridge, Bruce;
Peloton, Julien;
Perrotta, Francesca;
Piccirillo, Lucio;
Pisano, Giampaolo;
Poletti, Davide;
Puddu, Roberto;
Puglisi, Giuseppe;
Raum, Chris;
Reichardt, Christian L.;
Remazeilles, Mathieu;
Rephaeli, Yoel;
Riechers, Dominik;
Rojas, Felipe;
Roy, Anirban;
Sadeh, Sharon;
Sakurai, Yuki;
Salatino, Maria;
Rao, Mayuri Sathyanarayana;
Schaan, Emmanuel;
Schmittfull, Marcel;
Sehgal, Neelima;
Seibert, Joseph;
Seljak, Uros;
Sherwin, Blake;
Shimon, Meir;
Sierra, Carlos;
Sievers, Jonathan;
Sikhosana, Precious;
Silva-Feaver, Maximiliano;
Simon, Sara M.;
Sinclair, Adrian;
Siritanasak, Praween;
Smith, Kendrick;
Smith, Stephen R.;
Spergel, David;
Staggs, Suzanne T.;
Stein, George;
Stevens, Jason R.;
Stompor, Radek;
Suzuki, Aritoki;
Tajima, Osamu;
Takakura, Satoru;
Teply, Grant;
Thomas, Daniel B.;
Thorne, Ben;
Thornton, Robert;
Trac, Hy;
Tsai, Calvin;
Tucker, Carole;
Ullom, Joel;
Vagnozzi, Sunny;
van Engelen, Alexander;
Van Lanen, Jeff;
Van Winkle, Daniel D.;
Vavagiakis, Eve M.;
Vergès, Clara;
Vissers, Michael;
Wagoner, Kasey;
Walker, Samantha;
Ward, Jon;
Westbrook, Ben;
Whitehorn, Nathan;
Williams, Jason;
Williams, Joel;
Wollack, Edward J.;
Xu, Zhilei;
Yu, Byeonghee;
Yu, Cyndia;
Zago, Fernando;
Zhang, Hezi;
Zhu, Ningfeng
Submitted: 2018-08-22, last modified: 2019-03-01
The Simons Observatory (SO) is a new cosmic microwave background experiment
being built on Cerro Toco in Chile, due to begin observations in the early
2020s. We describe the scientific goals of the experiment, motivate the design,
and forecast its performance. SO will measure the temperature and polarization
anisotropy of the cosmic microwave background in six frequency bands: 27, 39,
93, 145, 225 and 280 GHz. The initial configuration of SO will have three
small-aperture 0.5-m telescopes (SATs) and one large-aperture 6-m telescope
(LAT), with a total of 60,000 cryogenic bolometers. Our key science goals are
to characterize the primordial perturbations, measure the number of
relativistic species and the mass of neutrinos, test for deviations from a
cosmological constant, improve our understanding of galaxy evolution, and
constrain the duration of reionization. The SATs will target the largest
angular scales observable from Chile, mapping ~10% of the sky to a white noise
level of 2 $\mu$K-arcmin in combined 93 and 145 GHz bands, to measure the
primordial tensor-to-scalar ratio, $r$, at a target level of $\sigma(r)=0.003$.
The LAT will map ~40% of the sky at arcminute angular resolution to an expected
white noise level of 6 $\mu$K-arcmin in combined 93 and 145 GHz bands,
overlapping with the majority of the LSST sky region and partially with DESI.
With up to an order of magnitude lower polarization noise than maps from the
Planck satellite, the high-resolution sky maps will constrain cosmological
parameters derived from the damping tail, gravitational lensing of the
microwave background, the primordial bispectrum, and the thermal and kinematic
Sunyaev-Zel'dovich effects, and will aid in delensing the large-angle
polarization signal to measure the tensor-to-scalar ratio. The survey will also
provide a legacy catalog of 16,000 galaxy clusters and more than 20,000
extragalactic sources.
[10]
oai:arXiv.org:1809.03689 [pdf] - 1748092
Highly-multiplexed microwave SQUID readout using the SLAC Microresonator
Radio Frequency (SMuRF) Electronics for Future CMB and Sub-millimeter Surveys
Henderson, Shawn W.;
Ahmed, Zeeshan;
Austermann, Jason;
Becker, Daniel;
Bennett, Douglas A.;
Brown, David;
Chaudhuri, Saptarshi;
Cho, Hsiao-Mei Sherry;
D'Ewart, John M.;
Dober, Bradley;
Duff, Shannon M.;
Dusatko, John E.;
Fatigoni, Sofia;
Frisch, Josef C.;
Gard, Jonathon D.;
Halpern, Mark;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Karpel, Ethan D.;
Kernasovskiy, Sarah S.;
Kuenstner, Stephen E.;
Kuo, Chao-Lin;
Li, Dale;
Mates, John A. B.;
Reintsema, Carl D.;
Smith, Stephen R.;
Ullom, Joel;
Vale, Leila R.;
Van Winkle, Daniel D.;
Vissers, Michael;
Yu, Cyndia
Submitted: 2018-09-11
The next generation of cryogenic CMB and submillimeter cameras under
development require densely instrumented sensor arrays to meet their science
goals. The readout of large numbers ($\sim$10,000--100,000 per camera) of
sub-Kelvin sensors, for instance as proposed for the CMB-S4 experiment, will
require substantial improvements in cold and warm readout techniques. To reduce
the readout cost per sensor and integration complexity, efforts are presently
focused on achieving higher multiplexing density while maintaining readout
noise subdominant to intrinsic detector noise. Highly-multiplexed cold readout
technologies in active development include Microwave Kinetic Inductance Sensors
(MKIDs) and microwave rf-SQUIDs. Both exploit the high quality factors of
superconducting microwave resonators to densely channelize sub-Kelvin sensors
into the bandwidth of a microwave transmission line. We present advancements in
the development of a new warm readout system for microwave SQUID multiplexing,
the SLAC Superconducting Microresonator RF electronics, or SMuRF. The SMuRF
system is unique in its ability to track each tone, minimizing the total RF
power required to read out each resonator, thereby significantly reducing the
linearity requirements on the cold and warm readout. Here, we present
measurements of the readout noise and linearity of the first full SMuRF system,
including a demonstration of closed-loop tone tracking on a 528 channel
cryogenic microwave SQUID multiplexer. SMuRF is being explored as a potential
readout solution for several future CMB projects including Simons Observatory,
BICEP Array, CCAT-prime, Ali-CPT, and CMB-S4. Parallel development of the
platform is underway to adapt SMuRF to read out both MKID and fast X-ray TES
calorimeter arrays.
[11]
oai:arXiv.org:1808.10491 [pdf] - 1746511
Studies of Systematic Uncertainties for Simons Observatory: Detector
Array Effects
Crowley, Kevin T.;
Simon, Sara M.;
Silva-Feaver, Max;
Goeckner-Wald, Neil;
Ali, Aamir;
Austermann, Jason;
Brown, Michael L.;
Chinone, Yuji;
Cukierman, Ari;
Dober, Bradley;
Duff, Shannon M.;
Dunkley, Jo;
Errard, Josquin;
Fabbian, Giulio;
Gallardo, Patricio A.;
Ho, Shuay-Pwu Patty;
Hubmayr, Johannes;
Keating, Brian;
Kusaka, Akito;
McCallum, Nialh;
McMahon, Jeff;
Nati, Federico;
Niemack, Michael D.;
Puglisi, Giuseppe;
Rao, Mayuri Sathyanarayana;
Reichardt, Christian L.;
Salatino, Maria;
Siritanasak, Praween;
Staggs, Suzanne;
Suzuki, Aritoki;
Teply, Grant;
Thomas, Daniel B.;
Ullom, Joel N.;
Vergès, Clara;
Vissers, Michael R.;
Westbrook, Benjamin;
Wollack, Edward J.;
Xu, Zhilei;
Zhu, Ningfeng
Submitted: 2018-08-30, last modified: 2018-09-06
In this proceeding, we present studies of instrumental systematic effects for
the Simons Obsevatory (SO) that are associated with the detector system and its
interaction with the full SO experimental systems. SO will measure the Cosmic
Microwave Background (CMB) temperature and polarization anisotropies over a
wide range of angular scales in six bands with bandcenters spanning from 27 GHz
to 270 GHz. We explore effects including intensity-to-polarization leakage due
to coupling optics, bolometer nonlinearity, uncalibrated gain variations of
bolometers, and readout crosstalk. We model the level of signal contamination,
discuss proposed mitigation schemes, and present instrument requirements to
inform the design of SO and future CMB projects.
[12]
oai:arXiv.org:1808.08489 [pdf] - 1739192
Preflight Characterization of the BLAST-TNG Receiver and Detector Arrays
Lourie, Nathan P.;
Ade, Peter A. R.;
Angile, Francisco E.;
Ashton, Peter C.;
Austermann, Jason E.;
Devlin, Mark J.;
Dober, Bradley;
Galitzki, Nicholas;
Gao, Jiansong;
Gordon, Sam;
Groppi, Christopher E.;
Klein, Jeffrey;
Hilton, Gene C.;
Hubmayr, Johannes;
Li, Dale;
Lowe, Ian;
Mani, Hamdi;
Mauskopf, Philip;
McKenney, Christopher M.;
Nati, Federico;
Novak, Giles;
Pascale, Enzo;
Pisano, Giampaolo;
Sinclair, Adrian;
Soler, Juan D.;
Tucker, Carole;
Ullom, Joel;
Vissers, Michael;
Williams, Paul A.
Submitted: 2018-08-25
The Next Generation Balloon-borne Large Aperture Submillimeter Telescope
(BLAST-TNG) is a submillimeter mapping experiment planned for a 28 day
long-duration balloon (LDB) flight from McMurdo Station, Antarctica during the
2018-2019 season. BLAST-TNG will detect submillimeter polarized interstellar
dust emission, tracing magnetic fields in galactic molecular clouds. BLAST-TNG
will be the first polarimeter with the sensitivity and resolution to probe the
$\sim$0.1 parsec-scale features that are critical to understanding the origin
of structures in the interstellar medium.
BLAST-TNG features three detector arrays operating at wavelengths of 250,
350, and 500 $\mu$m (1200, 857, and 600 GHz) comprised of 918, 469, and 272
dual-polarization pixels, respectively. Each pixel is made up of two crossed
microwave kinetic inductance detectors (MKIDs). These arrays are cooled to 275
mK in a cryogenic receiver. Each MKID has a different resonant frequency,
allowing hundreds of resonators to be read out on a single transmission line.
This inherent ability to be frequency-domain multiplexed simplifies the
cryogenic readout hardware, but requires careful optical testing to map out the
physical location of each resonator on the focal plane. Receiver-level optical
testing was carried out using both a cryogenic source mounted to a movable
xy-stage with a shutter, and a beam-filling, heated blackbody source able to
provide a 10-50 $^\circ$C temperature chop. The focal plane array noise
properties, responsivity, polarization efficiency, instrumental polarization
were measured. We present the preflight characterization of the BLAST-TNG
cryogenic system and array-level optical testing of the MKID detector arrays in
the flight receiver.
[13]
oai:arXiv.org:1808.04493 [pdf] - 1935462
The Simons Observatory: Instrument Overview
Galitzki, Nicholas;
Ali, Aamir;
Arnold, Kam S.;
Ashton, Peter C.;
Austermann, Jason E.;
Baccigalupi, Carlo;
Baildon, Taylor;
Barron, Darcy;
Beall, James A.;
Beckman, Shawn;
Bruno, Sarah Marie M.;
Bryan, Sean;
Calisse, Paolo G.;
Chesmore, Grace E.;
Chinone, Yuji;
Choi, Steve K.;
Coppi, Gabriele;
Crowley, Kevin D.;
Crowley, Kevin T.;
Cukierman, Ari;
Devlin, Mark J.;
Dicker, Simon;
Dober, Bradley;
Duff, Shannon M.;
Dunkley, Jo;
Fabbian, Giulio;
Gallardo, Patricio A.;
Gerbino, Martina;
Goeckner-Wald, Neil;
Golec, Joseph E.;
Gudmundsson, Jon E.;
Healy, Erin E.;
Henderson, Shawn;
Hill, Charles A.;
Hilton, Gene C.;
Ho, Shuay-Pwu Patty;
Howe, Logan A.;
Hubmayr, Johannes;
Jeong, Oliver;
Keating, Brian;
Koopman, Brian J.;
Kuichi, Kenji;
Kusaka, Akito;
Lashner, Jacob;
Lee, Adrian T.;
Li, Yaqiong;
Limon, Michele;
Lungu, Marius;
Matsuda, Frederick;
Mauskopf, Philip D.;
May, Andrew J.;
McCallum, Nialh;
McMahon, Jeff;
Nati, Federico;
Niemack, Michael D.;
Orlowski-Scherer, John L.;
Parshley, Stephen C.;
Piccirillo, Lucio;
Rao, Mayuri Sathyanarayana;
Raum, Christopher;
Salatino, Maria;
Seibert, Joseph S.;
Sierra, Carlos;
Silva-Feaver, Max;
Simon, Sara M.;
Staggs, Suzanne T.;
Stevens, Jason R.;
Suzuki, Aritoki;
Teply, Grant;
Thornton, Robert;
Tsai, Calvin;
Ullom, Joel N.;
Vavagiakis, Eve M.;
Vissers, Michael R.;
Westbrook, Benjamin;
Wollack, Edward J.;
Xu, Zhilei;
Zhu, Ningfeng
Submitted: 2018-08-13
The Simons Observatory (SO) will make precise temperature and polarization
measurements of the cosmic microwave background (CMB) using a set of telescopes
which will cover angular scales between 1 arcminute and tens of degrees,
contain over 60,000 detectors, and observe at frequencies between 27 and 270
GHz. SO will consist of a 6 m aperture telescope coupled to over 30,000
transition-edge sensor bolometers along with three 42 cm aperture refractive
telescopes, coupled to an additional 30,000+ detectors, all of which will be
located in the Atacama Desert at an altitude of 5190 m. The powerful
combination of large and small apertures in a CMB observatory will allow us to
sample a wide range of angular scales over a common survey area. SO will
measure fundamental cosmological parameters of our universe, constrain
primordial fluctuations, find high redshift clusters via the Sunyaev-Zel`dovich
effect, constrain properties of neutrinos, and trace the density and velocity
of the matter in the universe over cosmic time. The complex set of technical
and science requirements for this experiment has led to innovative
instrumentation solutions which we will discuss. The large aperture telescope
will couple to a cryogenic receiver that is 2.4 m in diameter and nearly 3 m
long, creating a number of technical challenges. Concurrently, we are designing
the array of cryogenic receivers housing the 42 cm aperture telescopes. We will
discuss the sensor technology SO will use and we will give an overview of the
drivers for and designs of the SO telescopes and receivers, with their cold
optical components and detector arrays.
[14]
oai:arXiv.org:1807.01384 [pdf] - 1740023
Low Temperature Detectors for CMB Imaging Arrays
Hubmayr, Johannes;
Austermann, Jason E.;
Beall, James A.;
Becker, Daniel T.;
Dober, Bradley;
Duff, Shannon M.;
Gao, Jiansong;
Hilton, Gene C.;
McKenney, Christopher M.;
Ullom, Joel N.;
Van Lanen, Jeff;
Vissers, Michael R.
Submitted: 2018-07-03
We review advances in low temperature detector (LTD) arrays for Cosmic
Microwave Background (CMB) polarization experiments, with a particular emphasis
on imaging arrays. We briefly motivate the science case, which has spurred a
large number of independent experimental efforts. We describe the challenges
associated with CMB polarization measurements and how these challenges impact
LTD design. Key aspects of an ideal CMB polarization imaging array are
developed and compared to the current state-of-the-art. These aspects include
dual-polarization-sensitivity, background-limited detection over a 10:1
bandwidth ratio, and frequency independent angular responses. Although existing
technology lacks all of this capability, today's CMB imaging arrays achieve
many of these ideals and are highly advanced superconducting integrated
circuits. Deployed arrays map the sky with pixels that contain elements for
beam formation, polarization diplexing, passband definition in multiple
frequency channels, and bolometric sensing. Several detector architectures are
presented. We comment on the implementation of both transition-edge-sensor
bolometers and microwave kinetic inductance detectors for CMB applications.
Lastly, we discuss fabrication capability in the context of next-generation
instruments that call for $\sim 10^6$ sensors.
[15]
oai:arXiv.org:1807.00058 [pdf] - 1839608
Prime-Cam: A first-light instrument for the CCAT-prime telescope
Vavagiakis, Eve M.;
Ahmed, Zeeshan;
Ali, Aamir;
Basu, Kaustuv;
Battaglia, Nicholas;
Bertoldi, Frank;
Bond, Richard;
Bustos, Ricardo;
Chapman, Scott C.;
Chung, Dongwoo;
Coppi, Gabriele;
Cothard, Nicholas F.;
Dicker, Simon;
Duell, Cody J.;
Duff, Shannon M.;
Erler, Jens;
Fich, Michel;
Galitzki, Nicholas;
Gallardo, Patricio A.;
Henderson, Shawn W.;
Herter, Terry L.;
Hilton, Gene;
Hubmayr, Johannes;
Irwin, Kent D.;
Koopman, Brian J.;
McMahon, Jeffrey;
Murray, Norman;
Niemack, Michael D.;
Nikolas, Thomas;
Nolta, Michael;
Orlowski-Scherer, John L.;
Parshley, Stephen C.;
Riechers, Dominik A.;
Rossi, Kayla;
Scott, Douglas;
Sierra, Carlos;
Silva-Feaver, Max;
Simon, Sara M.;
Stacey, Gordon J.;
Stevens, Jason R.;
Ullom, Joel N.;
Vissers, Michael R.;
Walker, Samantha;
Wollack, Edward J.;
Xu, Zhilei;
Zhu, Ningfeng
Submitted: 2018-06-29
CCAT-prime will be a 6-meter aperture telescope operating from sub-mm to mm
wavelengths, located at 5600 meters elevation on Cerro Chajnantor in the
Atacama Desert in Chile. Its novel crossed-Dragone optical design will deliver
a high throughput, wide field of view capable of illuminating much larger
arrays of sub-mm and mm detectors than can existing telescopes. We present an
overview of the motivation and design of Prime-Cam, a first-light instrument
for CCAT-prime. Prime-Cam will house seven instrument modules in a 1.8 meter
diameter cryostat, cooled by a dilution refrigerator. The optical elements will
consist of silicon lenses, and the instrument modules can be individually
optimized for particular science goals. The current design enables both
broadband, dual-polarization measurements and narrow-band, Fabry-Perot
spectroscopic imaging using multichroic transition-edge sensor (TES) bolometers
operating between 190 and 450 GHz. It also includes broadband kinetic induction
detectors (KIDs) operating at 860 GHz. This wide range of frequencies will
allow excellent characterization and removal of galactic foregrounds, which
will enable precision measurements of the sub-mm and mm sky. Prime-Cam will be
used to constrain cosmology via the Sunyaev-Zeldovich effects, map the
intensity of [CII] 158 $\mu$m emission from the Epoch of Reionization, measure
Cosmic Microwave Background polarization and foregrounds, and characterize the
star formation history over a wide range of redshifts. More information about
CCAT-prime can be found at www.ccatobservatory.org.
[16]
oai:arXiv.org:1803.03280 [pdf] - 1698088
Millimeter-Wave Polarimeters Using Kinetic Inductance Detectors for
TolTEC and Beyond
Austermann, J. E.;
Beall, J. A.;
Bryan, S. A.;
Dober, B.;
Gao, J.;
Hilton, G.;
Hubmayr, J.;
Mauskopf, P.;
McKenney, C. M.;
Simon, S. M.;
Ullom, J. N.;
Vissers, M. R.;
Wilson, G. W.
Submitted: 2018-03-08
Microwave Kinetic Inductance Detectors (MKIDs) provide a compelling path
forward to the large-format polarimeter, imaging, and spectrometer arrays
needed for next-generation experiments in millimeter-wave cosmology and
astronomy. We describe the development of feedhorn-coupled MKID detectors for
the TolTEC millimeter-wave imaging polarimeter being constructed for the
50-meter Large Millimeter Telescope (LMT). Observations with TolTEC are planned
to begin in early 2019. TolTEC will comprise $\sim$7,000 polarization sensitive
MKIDs and will represent the first MKID arrays fabricated and deployed on
monolithic 150 mm diameter silicon wafers -- a critical step towards future
large-scale experiments with over $10^5$ detectors. TolTEC will operate in
observational bands at 1.1, 1.4, and 2.0 mm and will use dichroic filters to
define a physically independent focal plane for each passband, thus allowing
the polarimeters to use simple, direct-absorption inductive structures that are
impedance matched to incident radiation. This work is part of a larger program
at NIST-Boulder to develop MKID-based detector technologies for use over a wide
range of photon energies spanning millimeter-waves to X-rays. We present the
detailed pixel layout and describe the methods, tools, and flexible design
parameters that allow this solution to be optimized for use anywhere in the
millimeter and sub-millimeter bands. We also present measurements of prototype
devices operating in the 1.1 mm band and compare the observed optical
performance to that predicted from models and simulations.
[17]
oai:arXiv.org:1711.04169 [pdf] - 1755845
280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2
Suborbital Polarimeter
Bergman, A. S.;
Ade, P. A. R.;
Akers, S.;
Amiri, M.;
Austermann, J. A.;
Beall, J. A.;
Becker, D. T.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Domagalski, R. S;
Doré, O.;
Duff, S. M.;
Duivenvoorden, A. J.;
Eriksen, H. K.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Fraisse, A. A.;
Freese, K.;
Galloway, M.;
Gambrel, A. E.;
Gandilo, N. N.;
Ganga, K.;
Grigorian, A.;
Gualtieri, R.;
Gudmundsson, J. E.;
Halpern, M.;
Hartley, J.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Huang, Z.;
Hubmayr, J.;
Irwin, K. D.;
Jones, W. C.;
Khan, A.;
Kuo, C. L.;
Kermish, Z. D.;
Li, S.;
Mason, P. V.;
Megerian, K.;
Moncelsi, L.;
Morford, T. A.;
Nagy, J. M.;
Netterfield, C. B.;
Nolta, M.;
Osherson, B.;
Padilla, I. L.;
Racine, B.;
Rahlin, A. S.;
Redmond, S.;
Reintsema, C.;
Romualdez, L. J.;
Ruhl, J. E.;
Runyan, M. C.;
Ruud, T. M.;
Shariff, J. A.;
Shaw, E. C.;
Shiu, C.;
Soler, J. D.;
Song, X.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Ullom, J.;
van der List, J. F.;
Van Lanen, J.;
Vissers, M. R.;
Weber, A. C.;
Wehus, I. K.;
Wen, S.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2017-11-11, last modified: 2017-11-22
We describe the construction and characterization of the 280 GHz bolometric
focal plane units (FPUs) to be deployed on the second flight of the
balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary
science goal of detecting or placing an upper limit on the amplitude of the
primordial gravitational wave signature in the cosmic microwave background
(CMB) by constraining the B-mode contamination in the CMB from Galactic dust
emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated
silicon feedhorns coupled to an array of aluminum-manganese transition-edge
sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the
three 280 GHz FPUs contain 1,530 polarization sensitive bolometers (765 spatial
pixels) optimized for the low loading environment in flight and read out by
time-division SQUID multiplexing. In this paper we describe the mechanical,
thermal, and magnetic shielding architecture of the focal planes and present
cryogenic measurements which characterize yield and the uniformity of several
bolometer parameters. The assembled FPUs have high yields, with one array as
high as 95% including defects from wiring and readout. We demonstrate high
uniformity in device parameters, finding the median saturation power for each
TES array to be ~3 pW at 300 mK with a less than 6% variation across each array
at one standard deviation. These focal planes will be deployed alongside the 95
and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo
Station in Antarctica in December 2018.
[18]
oai:arXiv.org:1611.05400 [pdf] - 1560203
An Open Source, FPGA-based LeKID readout for BLAST-TNG: Pre-flight
Results
Gordon, Samuel;
Dober, Bradley;
Sinclair, Adrian;
Rowe, Samuel;
Bryan, Sean;
Mauskopf, Philip;
Austermann, Jason;
Devlin, Mark;
Dicker, Simon;
Gao, Jiansong;
Hilton, Gene C.;
Hubmayr, Johannes;
Jones, Glenn;
Klein, Jeffrey;
Lourie, Nathan P.;
McKenney, Christopher;
Nati, Federico;
Soler, Juan D.;
Strader, Matthew;
Vissers, Michael
Submitted: 2016-11-16
We present a highly frequency multiplexed readout for large-format
superconducting detector arrays intended for use in the next generation of
balloon-borne and space-based sub-millimeter and far-infrared missions. We will
demonstrate this technology on the upcoming NASA Next Generation Balloon-borne
Large Aperture Sub-millimeter Telescope (BLAST-TNG) to measure the polarized
emission of Galactic dust at wavelengths of 250, 350 and 500 microns. The
BLAST-TNG receiver incorporates the first arrays of Lumped Element Kinetic
Inductance Detectors (LeKID) along with the first microwave multiplexing
readout electronics to fly in a space-like environment and will significantly
advance the TRL for these technologies. After the flight of BLAST-TNG, we will
continue to improve the performance of the detectors and readout electronics
for the next generation of balloon-borne instruments and for use in a future
FIR Surveyor.
[19]
oai:arXiv.org:1608.05456 [pdf] - 1459468
Instrumental performance and results from testing of the BLAST-TNG
receiver, submillimeter optics, and MKID arrays
Galitzki, Nicholas;
Ade, Peter;
Angile, Francesco E.;
Ashton, Peter;
Austermann, Jason;
Billings, Tashalee;
Che, George;
Cho, Hsiao-Mei;
Davis, Kristina;
Devlin, Mark;
Dicker, Simon;
Dober, Bradley J.;
Fissel, Laura M.;
Fukui, Yasuo;
Gao, Jiansong;
Gordon, Samuel;
Groppi, Christopher E.;
Hillbrand, Seth;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Klein, Jeffrey;
Li, Dale;
Li, Zhi-Yun;
Lourie, Nathan P.;
Lowe, Ian;
Mani, Hamdi;
Martin, Peter G.;
Mauskopf, Philip;
McKenney, Christopher;
Nati, Federico;
Novak, Giles;
Pascale, Enzo;
Pisano, Giampaolo;
Santos, Fabio P.;
Scott, Douglas;
Sinclair, Adrian;
Soler, Juan D.;
Tucker, Carole;
Underhill, Matthew;
Vissers, Michael;
Williams, Paul
Submitted: 2016-08-18
Polarized thermal emission from interstellar dust grains can be used to map
magnetic fields in star forming molecular clouds and the diffuse interstellar
medium (ISM). The Balloon-borne Large Aperture Submillimeter Telescope for
Polarimetry (BLASTPol) flew from Antarctica in 2010 and 2012 and produced
degree-scale polarization maps of several nearby molecular clouds with
arcminute resolution. The success of BLASTPol has motivated a next-generation
instrument, BLAST-TNG, which will use more than 3000 linear polarization
sensitive microwave kinetic inductance detectors (MKIDs) combined with a 2.5m
diameter carbon fiber primary mirror to make diffraction-limited observations
at 250, 350, and 500 $\mu$m. With 16 times the mapping speed of BLASTPol,
sub-arcminute resolution, and a longer flight time, BLAST-TNG will be able to
examine nearby molecular clouds and the diffuse galactic dust polarization
spectrum in unprecedented detail. The 250 $\mu$m detector array has been
integrated into the new cryogenic receiver, and is undergoing testing to
establish the optical and polarization characteristics of the instrument.
BLAST-TNG will demonstrate the effectiveness of kilo-pixel MKID arrays for
applications in submillimeter astronomy. BLAST-TNG is scheduled to fly from
Antarctica in December 2017 for 28 days and will be the first balloon-borne
telescope to offer a quarter of the flight for "shared risk" observing by the
community.
[20]
oai:arXiv.org:1606.09396 [pdf] - 1530923
Design of 280 GHz feedhorn-coupled TES arrays for the balloon-borne
polarimeter SPIDER
Hubmayr, Johannes;
Austermann, Jason E.;
Beall, James A.;
Becker, Daniel T.;
Benton, Steven J.;
Bergman, A. Stevie;
Bond, J. Richard;
Bryan, Sean;
Duff, Shannon M.;
Duivenvoorden, Adri J.;
Eriksen, H. K.;
Filippini, Jeffrey P.;
Fraisse, Aurelien A.;
Galloway, Mathew;
Gambrel, Anne E.;
Ganga, K.;
Grigorian, Arpi L.;
Gualtieri, Riccardo;
Gudmundsson, Jon E.;
Hartley, John W.;
Halpern, M.;
Hilton, Gene C.;
Jones, William C.;
McMahon, Jeffrey J.;
Moncelsi, Lorenzo;
Nagy, Johanna M.;
Netterfield, C. B.;
Osherson, Benjamin;
Padilla, Ivan;
Rahlin, Alexandra S.;
Racine, B.;
Ruhl, John;
Ruud, T. M.;
Shariff, J. A.;
Soler, J. D.;
Song, Xue;
Ullom, Joel N.;
Van Lanen, Jeff;
Vissers, Michael R.;
Wehus, I. K.;
Wen, Shyang;
Wiebe, D. V.;
Young, Edward
Submitted: 2016-06-30, last modified: 2016-07-07
We describe 280 GHz bolometric detector arrays that instrument the
balloon-borne polarimeter SPIDER. A primary science goal of SPIDER is to
measure the large-scale B-mode polarization of the cosmic microwave background
in search of the cosmic-inflation, gravitational-wave signature. 280 GHz
channels aid this science goal by constraining the level of B-mode
contamination from galactic dust emission. We present the focal plane unit
design, which consists of a 16$\times$16 array of conical, corrugated feedhorns
coupled to a monolithic detector array fabricated on a 150 mm diameter silicon
wafer. Detector arrays are capable of polarimetric sensing via waveguide
probe-coupling to a multiplexed array of transition-edge-sensor (TES)
bolometers. The SPIDER receiver has three focal plane units at 280 GHz, which
in total contains 765 spatial pixels and 1,530 polarization sensitive
bolometers. By fabrication and measurement of single feedhorns, we demonstrate
14.7$^{\circ}$ FHWM Gaussian-shaped beams with $<$1% ellipticity in a 30%
fractional bandwidth centered at 280 GHz. We present electromagnetic
simulations of the detection circuit, which show 94% band-averaged,
single-polarization coupling efficiency, 3% reflection and 3% radiative loss.
Lastly, we demonstrate a low thermal conductance bolometer, which is
well-described by a simple TES model and exhibits an electrical noise
equivalent power (NEP) = 2.6 $\times$ 10$^{-17}$ W/$\sqrt{\mathrm{Hz}}$,
consistent with the phonon noise prediction.
[21]
oai:arXiv.org:1603.02963 [pdf] - 1371678
Optical Demonstration of THz, Dual-Polarization Sensitive Microwave
Kinetic Inductance Detectors
Dober, B.;
Austermann, J. A.;
Beall, J. A.;
Becker, D.;
Che, G.;
Cho, H. M.;
Devlin, M.;
Duff, S. M.;
Galitzki, N.;
Gao, J.;
Groppi, C.;
Hilton, G. C.;
Hubmayr, J.;
Irwin, K. D.;
McKenney, C. M.;
Li, D.;
Lourie, N.;
Mauskopf, P.;
Vissers, M. R.;
Wang, Y.
Submitted: 2016-03-09
The next generation BLAST experiment (BLAST-TNG) is a suborbital balloon
payload that seeks to map polarized dust emission in the 250 $\mu$m, 350 $\mu$m
and 500 $\mu$m wavebands. The instrument utilizes a stepped half-wave plate to
reduce systematics. The general requirement of the detectors is that they are
photon-noise-limited and dual-polarization sensitive. To achieve this goal, we
are developing three monolithic arrays of cryogenic sensors, one for each
waveband. Each array is feedhorn-coupled and each spatial pixel consists of two
orthogonally spaced polarization-sensitive microwave kinetic inductance
detectors (MKIDs) fabricated from a Ti/TiN multilayer film. In previous work,
we demonstrated photon-noise-limited sensitivity in 250 $\mu$m waveband single
polarization devices. In this work, we present the first results of
dual-polarization sensitive MKIDs at 250 $\mu$m.
[22]
oai:arXiv.org:1406.4010 [pdf] - 969768
Photon-noise limited sensitivity in titanium nitride kinetic inductance
detectors
Hubmayr, Johannes;
Beall, Jim;
Becker, Dan;
Cho, Hsaio-Mei;
Devlin, Mark;
Dober, Bradley;
Groppi, Chris;
Hilton, Gene C.;
Irwin, Kent D.;
Li, Dale;
Mauskopf, Phillip;
Pappas, Dave P.;
Van Lanen, Jeff;
Vissers, Michael R.;
Wang, Yiwen;
Wei, Lian-Fu;
Gao, Jiansong
Submitted: 2014-06-16, last modified: 2015-03-23
We demonstrate photon-noise limited performance at sub-millimeter wavelengths
in feedhorn-coupled, microwave kinetic inductance detectors (MKIDs) made of a
TiN/Ti/TiN trilayer superconducting film, tuned to have a transition
temperature of 1.4~K. Micro-machining of the silicon-on-insulator wafer
backside creates a quarter-wavelength backshort optimized for efficient
coupling at 250~\micron. Using frequency read out and when viewing a variable
temperature blackbody source, we measure device noise consistent with photon
noise when the incident optical power is $>$~0.5~pW, corresponding to noise
equivalent powers $>$~3$\times 10^{-17}$ W/$\sqrt{\mathrm{Hz}}$. This
sensitivity makes these devices suitable for broadband photometric applications
at these wavelengths.
[23]
oai:arXiv.org:1409.7084 [pdf] - 896558
The Next Generation BLAST Experiment
Galitzki, Nicholas;
Ade, Peter A. R.;
Angilè, Francesco E.;
Ashton, Peter;
Beall, James A.;
Becker, Dan;
Bradford, Kristi J.;
Che, George;
Cho, Hsiao-Mei;
Devlin, Mark J.;
Dober, Bradley J.;
Fissel, Laura M.;
Fukui, Yasuo;
Gao, Jiansong;
Groppi, Christopher E.;
Hillbrand, Seth;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Klein, Jeffrey;
Van Lanen, Jeff;
Li, Dale;
Li, Zhi-Yun;
Lourie, Nathan P.;
Mani, Hamdi;
Martin, Peter G.;
Mauskopf, Philip;
Nakamura, Fumitaka;
Novak, Giles;
Pappas, David P.;
Pascale, Enzo;
Pisano, Giampaolo;
Santos, Fabio P.;
Savini, Giorgio;
Scott, Douglas;
Stanchfield, Sara;
Tucker, Carole;
Ullom, Joel N.;
Underhill, Matthew;
Vissers, Michael R.;
Ward-Thompson, Derek
Submitted: 2014-09-24, last modified: 2014-11-12
The Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry
(BLASTPol) was a suborbital experiment designed to map magnetic fields in order
to study their role in star formation processes. BLASTPol made detailed
polarization maps of a number of molecular clouds during its successful flights
from Antarctica in 2010 and 2012. We present the next-generation BLASTPol
instrument (BLAST-TNG) that will build off the success of the previous
experiment and continue its role as a unique instrument and a test bed for new
technologies. With a 16-fold increase in mapping speed, BLAST-TNG will make
larger and deeper maps. Major improvements include a 2.5 m carbon fiber mirror
that is 40% wider than the BLASTPol mirror and ~3000 polarization sensitive
detectors. BLAST-TNG will observe in three bands at 250, 350, and 500 microns.
The telescope will serve as a pathfinder project for microwave kinetic
inductance detector (MKID) technology, as applied to feedhorn coupled
submillimeter detector arrays. The liquid helium cooled cryostat will have a
28-day hold time and will utilize a closed-cycle $^3$He refrigerator to cool
the detector arrays to 270 mK. This will enable a detailed mapping of more
targets with higher polarization resolution than any other submillimeter
experiment to date. BLAST-TNG will also be the first balloon-borne telescope to
offer shared risk observing time to the community. This paper outlines the
motivation for the project and the instrumental design.
[24]
oai:arXiv.org:1407.3756 [pdf] - 1215656
The next-generation BLASTPol experiment
Dober, Bradley;
Ade, Peter A. R.;
Ashton, Peter;
Angilè, Francesco E.;
Beall, James A.;
Becker, Dan;
Bradford, Kristi J.;
Che, George;
Cho, Hsiao-Mei;
Devlin, Mark J.;
Fissel, Laura M.;
Fukui, Yasuo;
Galitzki, Nicholas;
Gao, Jiansong;
Groppi, Christopher E.;
Hillbrand, Seth;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Klein, Jeffrey;
Van Lanen, Jeff;
Li, Dale;
Li, Zhi-Yun;
Lourie, Nathan P.;
Mani, Hamdi;
Martin, Peter G.;
Mauskopf, Philip;
Nakamura, Fumitaka;
Novak, Giles;
Pappas, David P.;
Pascale, Enzo;
Santos, Fabio P.;
Savini, Giorgio;
Scott, Douglas;
Stanchfield, Sara;
Ullom, Joel N.;
Underhill, Matthew;
Vissers, Michael R.;
Ward-Thompson, Derek
Submitted: 2014-07-14
The Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry
(BLASTPol) is a suborbital mapping experiment designed to study the role
magnetic fields play in star formation. BLASTPol has had two science flights
from McMurdo Station, Antarctica in 2010 and 2012. These flights have produced
thousands of polarization vectors at 250, 350 and 500 microns in several
molecular cloud targets. We present the design, specifications, and progress
towards the next-generation BLASTPol experiment (BLAST-TNG). BLAST-TNG will fly
a 40% larger diameter primary mirror, with almost 8 times the number of
polarization-sensitive detectors resulting in a factor of 16 increase in
mapping speed. With a spatial resolution of 22 arcseconds and four times the
field of view of BLASTPol, BLAST-TNG will bridge the angular scales between
Planck's low resolution all-sky maps and ALMA's ultra-high resolution narrow
fields. The new receiver has a larger cryogenics volume, allowing for a 28 day
hold time. BLAST-TNG employs three arrays of Microwave Kinetic Inductance
Detectors (MKIDs) with 30% fractional bandwidth at 250, 350 and 500 microns. In
this paper, we will present the new BLAST-TNG instrument and science
objectives.