sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Vignoli, C.

Normalized to: Vignoli, C.

6 article(s) in total. 231 co-authors, from 1 to 6 common article(s). Median position in authors list is 26,0.

[1]  oai:arXiv.org:1204.5379  [pdf] - 503740
Light Sterile Neutrinos: A White Paper
Abazajian, K. N.; Acero, M. A.; Agarwalla, S. K.; Aguilar-Arevalo, A. A.; Albright, C. H.; Antusch, S.; Arguelles, C. A.; Balantekin, A. B.; Barenboim, G.; Barger, V.; Bernardini, P.; Bezrukov, F.; Bjaelde, O. E.; Bogacz, S. A.; Bowden, N. S.; Boyarsky, A.; Bravar, A.; Berguno, D. Bravo; Brice, S. J.; Bross, A. D.; Caccianiga, B.; Cavanna, F.; Chun, E. J.; Cleveland, B. T.; Collin, A. P.; Coloma, P.; Conrad, J. M.; Cribier, M.; Cucoanes, A. S.; D'Olivo, J. C.; Das, S.; de Gouvea, A.; Derbin, A. V.; Dharmapalan, R.; Diaz, J. S.; Ding, X. J.; Djurcic, Z.; Donini, A.; Duchesneau, D.; Ejiri, H.; Elliott, S. R.; Ernst, D. J.; Esmaili, A.; Evans, J. J.; Fernandez-Martinez, E.; Figueroa-Feliciano, E.; Fleming, B. T.; Formaggio, J. A.; Franco, D.; Gaffiot, J.; Gandhi, R.; Gao, Y.; Garvey, G. T.; Gavrin, V. N.; Ghoshal, P.; Gibin, D.; Giunti, C.; Gninenko, S. N.; Gorbachev, V. V.; Gorbunov, D. S.; Guenette, R.; Guglielmi, A.; Halzen, F.; Hamann, J.; Hannestad, S.; Haxton, W.; Heeger, K. M.; Henning, R.; Hernandez, P.; Huber, P.; Huelsnitz, W.; Ianni, A.; Ibragimova, T. V.; Karadzhov, Y.; Karagiorgi, G.; Keefer, G.; Kim, Y. D.; Kopp, J.; Kornoukhov, V. N.; Kusenko, A.; Kyberd, P.; Langacker, P.; Lasserre, Th.; Laveder, M.; Letourneau, A.; Lhuillier, D.; Li, Y. F.; Lindner, M.; Link, J. M.; Littlejohn, B. L.; Lombardi, P.; Long, K.; Lopez-Pavon, J.; Louis, W. C.; Ludhova, L.; Lykken, J. D.; Machado, P. A. N.; Maltoni, M.; Mann, W. A.; Marfatia, D.; Mariani, C.; Matveev, V. A.; Mavromatos, N. E.; Melchiorri, A.; Meloni, D.; Mena, O.; Mention, G.; Merle, A.; Meroni, E.; Mezzetto, M.; Mills, G. B.; Minic, D.; Miramonti, L.; Mohapatra, D.; Mohapatra, R. N.; Montanari, C.; Mori, Y.; Mueller, Th. A.; Mumm, H. P.; Muratova, V.; Nelson, A. E.; Nico, J. S.; Noah, E.; Nowak, J.; Smirnov, O. Yu.; Obolensky, M.; Pakvasa, S.; Palamara, O.; Pallavicini, M.; Pascoli, S.; Patrizii, L.; Pavlovic, Z.; Peres, O. L. G.; Pessard, H.; Pietropaolo, F.; Pitt, M. L.; Popovic, M.; Pradler, J.; Ranucci, G.; Ray, H.; Razzaque, S.; Rebel, B.; Robertson, R. G. H.; Rodejohann, W.; Rountree, S. D.; Rubbia, C.; Ruchayskiy, O.; Sala, P. R.; Scholberg, K.; Schwetz, T.; Shaevitz, M. H.; Shaposhnikov, M.; Shrock, R.; Simone, S.; Skorokhvatov, M.; Sorel, M.; Sousa, A.; Spergel, D. N.; Spitz, J.; Stanco, L.; Stancu, I.; Suzuki, A.; Takeuchi, T.; Tamborra, I.; Tang, J.; Testera, G.; Tian, X. C.; Tonazzo, A.; Tunnell, C. D.; Van de Water, R. G.; Verde, L.; Veretenkin, E. P.; Vignoli, C.; Vivier, M.; Vogelaar, R. B.; Wascko, M. O.; Wilkerson, J. F.; Winter, W.; Wong, Y. Y. Y.; Yanagida, T. T.; Yasuda, O.; Yeh, M.; Yermia, F.; Yokley, Z. W.; Zeller, G. P.; Zhan, L.; Zhang, H.
Comments:
Submitted: 2012-04-18
This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data.
[2]  oai:arXiv.org:1108.5584  [pdf] - 1083670
Demonstration and Comparison of Operation of Photomultiplier Tubes at Liquid Argon Temperature
Comments:
Submitted: 2011-08-29, last modified: 2011-09-26
Liquified noble gases are widely used as a target in direct Dark Matter searches. Signals from scintillation in the liquid, following energy deposition from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should be recorded down to very low energies by photosensors suitably designed to operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter searches currently implement photo multiplier tubes for signal read-out. In the last few years PMTs with photocathodes operating down to liquid Argon temperatures (87 K) have been specially developed with increasing Quantum Efficiency characteristics. The most recent of these, Hamamatsu Photonics Mod. R11065 with peak QE up to about 35%, has been extensively tested within the R&D program of the WArP Collaboration. During these testes the Hamamatsu PMTs showed superb performance and allowed obtaining a light yield around 7 phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12% range, sufficient for detection of events down to few keVee of energy deposition. This shows that this new type of PMT is suited for experimental applications, in particular for new direct Dark Matter searches with LAr-based experiments.
[3]  oai:arXiv.org:astro-ph/0701286  [pdf] - 88415
First results from a Dark Matter search with liquid Argon at 87 K in the Gran Sasso Underground Laboratory
Comments: 26 pages, 8 figures, submitted to astroparticle physics
Submitted: 2007-01-10, last modified: 2007-01-16
A new method of searching for dark matter in the form of weakly interacting massive particles (WIMP) has been developed with the direct detection of the low energy nuclear recoils observed in a massive target (ultimately many tons) of ultra pure Liquid Argon at 87 K. A high selectivity for Argon recoils is achieved by the simultaneous observation of both the VUV scintillation luminescence and of the electron signal surviving columnar recombination, extracted through the liquid-gas boundary by an electric field. First physics results from this method are reported, based on a small 2.3 litre test chamber filled with natural Argon and an accumulated fiducial exposure of about 100 kg x day, supporting the future validity of this method with isotopically purified 40Ar and for a much larger unit presently under construction with correspondingly increased sensitivities.
[4]  oai:arXiv.org:astro-ph/0603131  [pdf] - 80340
Measurement of the specific activity of Ar-39 in natural argon
Comments: 11 pages, 6 figures, to be submitted to Nucl. Instrum. Methods A
Submitted: 2006-03-06, last modified: 2007-01-10
We report on the measurement of the specific activity of Ar-39 in natural argon. The measurement was performed with a 2.3-liter two-phase (liquid and gas) argon drift chamber. The detector was developed by the WARP Collaboration as a prototype detector for WIMP Dark Matter searches with argon as a target. The detector was operated for more than two years at Laboratori Nazionali del Gran Sasso, Italy, at a depth of 3,400 m w.e. The specific activity measured for Ar-39 is 1.01 +/- 0.02(stat) +/- 0.08(syst) Bq per kg of natural Ar.
[5]  oai:arXiv.org:astro-ph/0411491  [pdf] - 1507895
WARP: a WIMP double phase Argon detector
Comments: Proceeding for IDM2004
Submitted: 2004-11-17
The WARP programme for dark matter search with a double phase argon detector is presented. In such a detector both excitation and ionization produced by an impinging particle are evaluated by the contemporary measurement of primary scintillation and secondary (proportional) light signal, this latter being produced by extracting and accelerating ionization electrons in the gas phase. The proposed technique, verified on a 2.3 liters prototype, could be used to efficiently discriminate nuclear recoils, induced by WIMP's interactions, and measure their energy spectrum. An overview of the 2.3 liters results and of the proposed 100 liters detector is shown.
[6]  oai:arXiv.org:astro-ph/0405342  [pdf] - 64862
WARP liquid argon detector for dark matter survey
Comments: Proceeding of the 6th UCLA Symposium on Sources and detection of Dark Matter and dark Energy in the Universe
Submitted: 2004-05-18
The WARP programme is a graded programme intended to search for cold Dark Matter in the form of WIMP's. These particles may produce via weak interactions nuclear recoils in the energy range 10-100 keV. A cryogenic noble liquid like argon, already used in the realization of very large detector, permits the simultaneous detection of both ionisation and scintillation induced by an interaction, suggesting the possibility of discriminating between nuclear recoils and electrons mediated events. A 2.3 litres two-phase argon detector prototype has been used to perform several tests on the proposed technique. Next step is the construction of a 100 litres sensitive volume device with potential sensitivity a factor 100 better than presently existing experiments.