sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Vignati, Marco

Normalized to: Vignati, M.

6 article(s) in total. 165 co-authors, from 1 to 4 common article(s). Median position in authors list is 12,5.

[1]  oai:arXiv.org:1910.07450  [pdf] - 1981331
Proceedings of The Magnificent CE$\nu$NS Workshop 2018
Comments: The Magnificent CEvNS Workshop (2018), Nov 2-3, 2018; Chicago, IL, USA; 44 contributions
Submitted: 2019-10-16
The Magnificent CE$\nu$NS Workshop (2018) was held November 2 & 3 of 2018 on the University of Chicago campus and brought together theorists, phenomenologists, and experimentalists working in numerous areas but sharing a common interest in the process of coherent elastic neutrino-nucleus scattering (CE$\nu$NS). This is a collection of abstract-like summaries of the talks given at the meeting, including links to the slides presented. This document and the slides from the meeting provide an overview of the field and a snapshot of the robust CE$\nu$NS-related efforts both planned and underway.
[2]  oai:arXiv.org:1606.04565  [pdf] - 1579984
High sensitivity phonon-mediated kinetic inductance detector with combined amplitude and phase read-out
Comments:
Submitted: 2016-06-14, last modified: 2016-12-14
The development of wide-area cryogenic light detectors with good energy resolution is one of the priorities of next generation bolometric experiments searching for rare interactions, as the simultaneous read-out of the light and heat signals enables background suppression through particle identification. Among the proposed technological approaches for the phonon sensor, the naturally-multiplexed Kinetic Inductance Detectors (KIDs) stand out for their excellent intrinsic energy resolution and reproducibility. To satisfy the large surface requirement (several cm$^2$) KIDs are deposited on an insulating substrate that converts the impinging photons into phonons. A fraction of phonons is absorbed by the KID, producing a signal proportional to the energy of the original photons. The potential of this technique was proved by the CALDER project, that reached a baseline resolution of 154$\pm$7 eV RMS by sampling a 2$\times$2 cm$^2$ Silicon substrate with 4 Aluminum KIDs. In this paper we present a prototype of Aluminum KID with improved geometry and quality factor. The design improvement, as well as the combined analysis of amplitude and phase signals, allowed to reach a baseline resolution of 82$\pm$4 eV by sampling the same substrate with a single Aluminum KID.
[3]  oai:arXiv.org:1604.03314  [pdf] - 1389056
New application of superconductors: high sensitivity cryogenic light detectors
Comments:
Submitted: 2016-04-12
In this paper we describe the current status of the CALDER project, which is developing ultra-sensitive light detectors based on superconductors for cryogenic applications. When we apply an AC current to a superconductor, the Cooper pairs oscillate and acquire kinetic inductance, that can be measured by inserting the superconductor in a LC circuit with high merit factor. Interactions in the superconductor can break the Cooper pairs, causing sizable variations in the kinetic inductance and, thus, in the response of the LC circuit. The continuous monitoring of the amplitude and frequency modulation allows to reconstruct the incident energy with excellent sensitivity. This concept is at the basis of Kinetic Inductance Detectors (KIDs), that are characterized by natural aptitude to multiplexed read-out (several sensors can be tuned to different resonant frequencies and coupled to the same line), resolution of few eV, stable behavior over a wide temperature range, and ease in fabrication. We present the results obtained by the CALDER collaboration with 2x2 cm2 substrates sampled by 1 or 4 Aluminum KIDs. We show that the performances of the first prototypes are already competitive with those of other commonly used light detectors, and we discuss the strategies for a further improvement.
[4]  oai:arXiv.org:1209.2519  [pdf] - 621874
The low energy spectrum of TeO2 bolometers: results and dark matter perspectives for the CUORE-0 and CUORE experiments
Alessandria, F.; Ardito, R.; Artusa, D. R.; Avignone, F. T.; Azzolini, O.; Balata, M.; Banks, T. I.; Bari, G.; Beeman, J.; Bellini, F.; Bersani, A.; Biassoni, M.; Bloxham, T.; Brofferio, C.; Bucci, C.; Cai, X. Z.; Canonica, L.; Capelli, S.; Carbone, L.; Cardani, L.; Carrettoni, M.; Casali, N.; Chott, N.; Clemenza, M.; Cosmelli, C.; Cremonesi, O.; Creswick, R. J.; Dafinei, I.; Dally, A.; Datskov, V.; De Biasi, A.; Decowski, M. P.; Deninno, M. M.; Di Domizio, S.; di Vacri, M. L.; Ejzak, L.; Faccini, R.; Fang, D. Q.; Farach, H. A.; Ferri, E.; Ferroni, F.; Fiorini, E.; Franceschi, M. A.; Freedman, S. J.; Frossati, G.; Fujikawa, B. K.; Giachero, A.; Gironi, L.; Giuliani, A.; Goett, J. J.; Gorla, P.; Gotti, C.; Guardincerri, E.; Gutierrez, T. D.; Haller, E. E.; Han, K.; Heeger, K. M.; Huang, H. Z.; Kadel, R.; Kazkaz, K.; Keppel, G.; Kogler, L.; Kolomensky, Yu. G.; Lenz, D.; Li, Y. L.; Ligi, C.; Liu, X.; Ma, Y. G.; Maiano, C.; Maino, M.; Martinez, M.; Maruyama, R. H.; Moggi, N.; Morganti, S.; Napolitano, T.; Newman, S.; Nisi, S.; Nones, C.; Norman, E. B.; Nucciotti, A.; Orio, F.; Orlandi, D.; Ouellet, J. L.; Pallavicini, M.; Palmieri, V.; Pattavina, L.; Pavan, M.; Pedretti, M.; Pessina, G.; Pirro, S.; Previtali, E.; Rampazzo, V.; Rimondi, F.; Rosenfeld, C.; Rusconi, C.; Sangiorgio, S.; Scielzo, N. D.; Sisti, M.; Smith, A. R.; Stivanello, F.; Taffarello, L.; Tenconi, M.; Tian, W. D.; Tomei, C.; Trentalange, S.; Ventura, G.; Vignati, M.; Wang, B. S.; Wang, H. W.; Whitten, C. A.; Wise, y T.; Woodcraft, A.; Zanotti, L.; Zarra, C.; Zhu, B. X.; Zucchelli, S.
Comments: 9 pages, 10 figures
Submitted: 2012-09-12, last modified: 2013-02-01
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three of them we were able to set the energy threshold around 3 keV using a new analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3 keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak is presently unknown, but its presence is confirmed by a reanalysis of 62.7 kg.days of data from the finished CUORICINO experiment. Finally, we report the expected sensitivities of the CUORE0 (52 bolometers) and CUORE (988 bolometers) experiments to a WIMP annual modulation signal.
[5]  oai:arXiv.org:1102.3564  [pdf] - 1934591
Feasibility study of dark matter searches with the CUORE experiment
Comments: Conference proceedings from the Identification of Dark Matter 2010, Montpellier, France. To be published by SISSA as PoS(IDM2010)019. 7 pages, 7 figures
Submitted: 2011-02-17
CUORE will be a 1 ton experiment made of about 1000 TeO$_2$ bolometers. It will probe the neutrinoless double beta decay (0$\nu$DBD) of $^{130}$Te, a tool to test the neutrino nature and mass. The excellent energy resolution and the low background of these detectors will make CUORE a leading experiment in this field, improving the sensitivity to the half-life of 0$\nu$DBD by more than an order of magnitude. Bolometric detectors, however, are also sensitive to nuclear recoils and can be used to search for dark matter interactions. In principle CUORE, thanks to its mass, could look for an annual modulation of the counting rate at low energies. We developed a trigger and a pulse shape identification algorithm, that allow to lower the energy threshold down to the few keV region. We present the preliminary results obtained on an array made of four CUORE-like crystals, and the prospects for a dark matter search in CUORE.
[6]  oai:arXiv.org:1012.1263  [pdf] - 955710
Lowering the energy threshold of large-mass bolometric detectors
Comments: 12 pages, 12 figures
Submitted: 2010-12-06
Large-mass bolometers are used in particle physics experiments to search for rare processes. The energy threshold of such detectors plays a critical role in their capability to search for dark matter interactions and rare nuclear decays. We have developed a trigger and a pulse shape algorithm based on the matched filter technique which, when applied to data from test bolometers of the CUORE experiment, lowered the energy threshold from tens of keV to the few keV region. The detection efficiency is in excess of 80%, and nearly all nonphysical pulses are rejected.