sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Verhoeve, P.

Normalized to: Verhoeve, P.

5 article(s) in total. 31 co-authors, from 1 to 4 common article(s). Median position in authors list is 4,0.

[1]  oai:arXiv.org:1506.07831  [pdf] - 1265746
How well can Charge Transfer Inefficiency be corrected? A parameter sensitivity study for iterative correction
Comments:
Submitted: 2015-06-25
Radiation damage to space-based Charge-Coupled Device (CCD) detectors creates defects which result in an increasing Charge Transfer Inefficiency (CTI) that causes spurious image trailing. Most of the trailing can be corrected during post-processing, by modelling the charge trapping and moving electrons back to where they belong. However, such correction is not perfect -- and damage is continuing to accumulate in orbit. To aid future development, we quantify the limitations of current approaches, and determine where imperfect knowledge of model parameters most degrade measurements of photometry and morphology. As a concrete application, we simulate $1.5\times10^{9}$ "worst case" galaxy and $1.5\times10^{8}$ star images to test the performance of the Euclid visual instrument detectors. There are two separable challenges: If the model used to correct CTI is perfectly the same as that used to add CTI, $99.68$ % of spurious ellipticity is corrected in our setup. This is because readout noise is not subject to CTI, but gets over-corrected during correction. Second, if we assume the first issue to be solved, knowledge of the charge trap density within $\Delta\rho/\rho\!=\!(0.0272\pm0.0005)$ %, and the characteristic release time of the dominant species to be known within $\Delta\tau/\tau\!=\!(0.0400\pm0.0004)$ % will be required. This work presents the next level of definition of in-orbit CTI calibration procedures for Euclid.
[2]  oai:arXiv.org:0911.0313  [pdf] - 1018177
First results of a cryogenic optical photon counting imaging spectrometer using a DROID array
Comments: 7 pages, 9 figures, accepted for publicaiton in A&A
Submitted: 2009-11-02
Context. In this paper we present the first system test in which we demonstrate the concept of using an array of Distributed Read Out Imaging Devices (DROIDs) for optical photon detection. Aims. After the successful S-Cam 3 detector the next step in the development of a cryogenic optical photon counting imaging spectrometer under the S-Cam project is to increase the field of view using DROIDs. With this modification the field of view of the camera has been increased by a factor of 5 in area, while keeping the number of readout channels the same. Methods. The test has been performed using the flexible S-Cam 3 system and exchanging the 10x12 Superconducting Tunnel Junction array for a 3x20 DROID array. The extra data reduction needed with DROIDs is performed offline. Results. We show that, although the responsivity (number of tunnelled quasiparticles per unit of absorbed photon energy, e- /eV) of the current array is too low for direct astronomical applications, the imaging quality is already good enough for pattern detection, and will improve further with increasing responsivity. Conclusions. The obtained knowledge can be used to optimise the system for the use of DROIDs.
[3]  oai:arXiv.org:0806.3634  [pdf] - 13785
Simultaneous Absolute Timing of the Crab Pulsar at Radio and Optical Wavelengths
Comments: 8 pages; accepted for publication in Astronomy and Astrophysics
Submitted: 2008-06-23
The Crab pulsar emits across a large part of the electromagnetic spectrum. Determining the time delay between the emission at different wavelengths will allow to better constrain the site and mechanism of the emission. We have simultaneously observed the Crab Pulsar in the optical with S-Cam, an instrument based on Superconducting Tunneling Junctions (STJs) with $\mu$s time resolution and at 2 GHz using the Nan\c{c}ay radio telescope with an instrument doing coherent dedispersion and able to record giant pulses data. We have studied the delay between the radio and optical pulse using simultaneously obtained data therefore reducing possible uncertainties present in previous observations. We determined the arrival times of the (mean) optical and radio pulse and compared them using the tempo2 software package. We present the most accurate value for the optical-radio lag of 255 $\pm$ 21 $\mu$s and suggest the likelihood of a spectral dependence to the excess optical emission asociated with giant radio pulses.
[4]  oai:arXiv.org:astro-ph/0606146  [pdf] - 82586
Absolute timing of the Crab Pulsar at optical wavelengths with STJs
Comments: 5 pages, 2 figures, accepted for publication in Astronomy & Astrophysics
Submitted: 2006-06-07
We have observed the Crab Pulsar in the optical with S-Cam, an instrument based on Superconducting Tunneling Junctions (STJs) with $\mu$s time resolution. Our aim was to study the delay between the radio and optical pulse. The Crab Pulsar was observed three times over a time span of almost 7 years, on two different locations, using three different versions of the instrument, and using two different GPS units. We consistently find that the optical peak leads the radio peak by 49$\pm$90, 254$\pm$170, and 291$\pm$100 $\mu$s. On assumption of a constant optical lead, the weighted-average value is $\sim$170 $\mu$s, or when rejecting (based on a perhaps questionable radio ephemeris) the first measurement, 273$\pm$100 $\mu$s.
[5]  oai:arXiv.org:astro-ph/0111476  [pdf] - 46242
Direct determination of quasar redshifts
Comments: 4 pages, 3 figures; uses aa.cls, psfig.sty, natbib.sty; accepted for publication in A&A Letters
Submitted: 2001-11-26
We present observations of 11 quasars, selected in the range z = 2.2-4.1, obtained with ESA's Superconducting Tunnel Junction (STJ) camera on the WHT. Using a single template quasar spectrum, we show that we can determine the redshifts of these objects to about 1%. A follow-up spectroscopic observation of one QSO for which our best-fit redshift (z = 2.976) differs significantly from the tentative literature value (z ~ 2.30) confirms that the latter was incorrect.