Normalized to: Venditti, N.
[1]
oai:arXiv.org:1403.6841 [pdf] - 1370150
Development of Fiber Fabry-Perot Interferometers as Stable Near-infrared
Calibration Sources for High Resolution Spectrographs
Halverson, Samuel;
Mahadevan, Suvrath;
Ramsey, Lawrence;
Hearty, Fred;
Wilson, John;
Holtzman, Jon;
Redman, Stephen;
Nave, Gillian;
Nidever, David;
Nelson, Matt;
Venditti, Nick;
Bizyaev, Dmitry;
Fleming, Scott
Submitted: 2014-03-26
We discuss the ongoing development of single-mode fiber Fabry-Perot (FFP)
Interferometers as precise astro-photonic calibration sources for high
precision radial velocity (RV) spectrographs. FFPs are simple, inexpensive,
monolithic units that can yield a stable and repeatable output spectrum. An FFP
is a unique alternative to a traditional etalon, as the interferometric cavity
is made of single-mode fiber rather than an air-gap spacer. This design allows
for excellent collimation, high spectral finesse, rigid mechanical stability,
insensitivity to vibrations, and no need for vacuum operation. The device we
have tested is a commercially available product from Micron Optics. Our
development path is targeted towards a calibration source for the
Habitable-Zone Planet Finder (HPF), a near-infrared spectrograph designed to
detect terrestrial-mass planets around low-mass stars, but this reference could
also be used in many existing and planned fiber-fed spectrographs as we
illustrate using the Apache Point Observatory Galactic Evolution Experiment
(APOGEE) instrument. With precise temperature control of the fiber etalon, we
achieve a thermal stability of 100 $\mu$K and associated velocity uncertainty
of 22 cm s$^{-1}$. We achieve a precision of $\approx$2 m s$^{-1}$ in a single
APOGEE fiber over 12 hours using this new photonic reference after removal of
systematic correlations. This high precision (close to the expected
photon-limited floor) is a testament to both the excellent intrinsic wavelength
stability of the fiber interferometer and the stability of the APOGEE
instrument design. Overall instrument velocity precision is 80 cm s$^{-1}$ over
12 hours when averaged over all 300 APOGEE fibers and after removal of known
trends and pressure correlations, implying the fiber etalon is intrinsically
stable to significantly higher precision.
[2]
oai:arXiv.org:1403.1577 [pdf] - 1208221
Suppression of Fiber Modal Noise Induced Radial Velocity Errors for
Bright Emission-Line Calibration Sources
Submitted: 2014-03-06
Modal noise in optical fibers imposes limits on the signal to noise and
velocity precision achievable with the next generation of astronomical
spectrographs. This is an increasingly pressing problem for precision radial
velocity (RV) spectrographs in the near-infrared (NIR) and optical that require
both high stability of the observed line profiles and high signal to noise.
Many of these spectrographs plan to use highly coherent emission line
calibration sources like laser frequency combs and Fabry-Perot etalons to
achieve precision sufficient to detect terrestrial mass planets. These high
precision calibration sources often use single mode fibers or highly coherent
sources. Coupling light from single mode fibers to multi-mode fibers leads to
only a very low number of modes being excited, thereby exacerbating the modal
noise measured by the spectrograph. We present a commercial off-the-shelf
(COTS) solution that significantly mitigates modal noise at all optical and NIR
wavelengths, and which can be applied to spectrograph calibration systems. Our
solution uses an integrating sphere in conjunction with a diffuser that is
moved rapidly using electrostrictive polymers, and is generally superior to
most tested forms of mechanical fiber agitation. We demonstrate a high level of
modal noise reduction with a narrow bandwidth 1550 nm laser. Our relatively
inexpensive solution immediately enables spectrographs to take advantage of the
innate precision of bright state-of-the art calibration sources by removing a
major source of systematic noise.