oai:arXiv.org:1207.6118 [pdf] - 1125104
Design and construction progress of LRS2-B: a new low resolution
integral field spectrograph for the Hobby-Eberly Telescope
Submitted: 2012-07-25, last modified: 2014-07-25
The upcoming Wide-Field Upgrade (WFU) has ushered in a new era of
instrumentation for the Hobby-Eberly Telescope (HET). Here, we present the
design, construction progress, and lab tests completed to date of the
blue-optimized second generation Low Resolution Spectrograph (LRS2-B). LRS2-B
is a dual-channel, fiber fed instrument that is based on the design of the
Visible Integral Field Replicable Unit Spectrograph (VIRUS), which is the new
flagship instrument for carrying out the HET Dark Energy eXperiment (HETDEX).
LRS2-B utilizes a microlens-coupled integral field unit (IFU) that covers a
7"x12" area on the sky having unity fill-factor with ~300 spatial elements that
subsample the median HET image quality. The fiber feed assembly includes an
optimized dichroic beam splitter that allows LRS2-B to simultaneously observe
370 nm to 470 nm and 460 nm to 700 nm at fixed resolving powers of R \approx
1900 and 1200, respectively. We discuss the departures from the nominal VIRUS
design, which includes the IFU, fiber feed, camera correcting optics, and
volume phase holographic grisms. Additionally, the motivation for the selection
of the wavelength coverage and spectral resolution of the two channels is
briefly discussed. One such motivation is the follow-up study of spectrally and
(or) spatially resolved Lyman-alpha emission from z ~ 2.5 star-forming galaxies
in the HETDEX survey. LRS2-B is planned to be a commissioning instrument for
the HET WFU and should be on-sky during quarter 4 of 2013. Finally, we mention
the current state of LRS2-R, the red optimized sister instrument of LRS2-B.
[2]
oai:arXiv.org:1407.6016 [pdf] - 1215849
LRS2: the new facility low resolution integral field spectrograph for
the Hobby-Eberly Telescope
Submitted: 2014-07-22
The second generation Low Resolution Spectrograph (LRS2) is a new facility
instrument for the Hobby-Eberly Telescope (HET). Based on the design of the
Visible Integral-field Replicable Unit Spectrograph (VIRUS), which is the new
flagship instrument for carrying out the HET Dark Energy Experiment (HETDEX),
LRS2 provides integral field spectroscopy for a seeing-limited field of 12 x 6
arcseconds. For LRS2, the replicable design of VIRUS has been leveraged to gain
broad wavelength coverage from 370 nm to 1 micron, spread between two fiber-fed
dual-channel spectrographs, each of which can operate as an independent
instrument. The blue spectrograph, LRS2-B, covers 370-470 nm and 460-700 nm at
fixed resolving powers of ~1900 and ~1100, respectively, while the red
spectrograph, LRS2-R, covers 650-842 nm and 818-1050 nm with both of its
channels having a resolving power of ~1800. In this paper, we present a
detailed description of the instrument's design in which we focus on the
departures from the basic VIRUS framework. The primary modifications include
the fore-optics that are used to feed the fiber integral field units at unity
fill-factor, the cameras' correcting optics and detectors, and the volume phase
holographic grisms. We also present a model of the instrument's sensitivity and
a description of specific science cases that have driven the design of LRS2,
including systematically studying the spatially resolved properties of extended
Lyman-alpha blobs at 2 < z < 3. LRS2 will provide a powerful spectroscopic
follow-up platform for large surveys such as HETDEX.
[3]
oai:arXiv.org:1305.0309 [pdf] - 659091
The Influence of Motion and Stress on Optical Fibers
Murphy, Jeremy D.;
Hill, Gary J.;
MacQueen, Phillip J.;
Taylor, Trey;
Soukup, Ian;
Moreira, Walter;
Cornell, Mark E.;
Good, John;
Anderson, Seth;
Fuller, Lindsay;
Lee, Hanshin;
Kelz, Andreas;
Rafal, Marc;
Rafferty, Tom;
Tuttle, Sarah;
Vattiat, Brian
Submitted: 2013-05-01
We report on extensive testing carried out on the optical fibers for the
VIRUS instrument. The primary result of this work explores how 10+ years of
simulated wear on a VIRUS fiber bundle affects both transmission and focal
ratio degradation (FRD) of the optical fibers. During the accelerated lifetime
tests we continuously monitored the fibers for signs of FRD. We find that
transient FRD events were common during the portions of the tests when motion
was at telescope slew rates, but dropped to negligible levels during rates of
motion typical for science observation. Tests of fiber transmission and FRD
conducted both before and after the lifetime tests reveal that while
transmission values do not change over the 10+ years of simulated wear, a clear
increase in FRD is seen in all 18 fibers tested. This increase in FRD is likely
due to microfractures that develop over time from repeated flexure of the fiber
bundle, and stands in contrast to the transient FRD events that stem from
localized stress and subsequent modal diffusion of light within the fibers.
There was no measurable wavelength dependence on the increase in FRD over 350
nm to 600 nm. We also report on bend radius tests conducted on individual
fibers and find the 266 microns VIRUS fibers to be immune to bending-induced
FRD at bend radii of R > 10cm. Below this bend radius FRD increases slightly
with decreasing radius. Lastly, we give details of a degradation seen in the
fiber bundle currently deployed on the Mitchell Spectrograph (formally VIRUS-P)
at McDonald Observatory. The degradation is shown to be caused by a localized
shear in a select number of optical fibers that leads to an explosive form of
FRD. In a few fibers, the overall transmission loss through the instrument can
exceed 80%.