[1]  oai:arXiv.org:1207.6118  [pdf] - 1125104
Design and construction progress of LRS2-B: a new low resolution integral field spectrograph for the Hobby-Eberly Telescope
Comments: 22 pages, 12 figures, 2 tables. To be published in Proc. SPIE, 2012, "Ground-Based and Airborne Instrumentation for Astronomy IV", 8446-103. In v2, a note has been added indicating that this paper has been superseded by arXiv:1407:6016
Submitted: 2012-07-25, last modified: 2014-07-25
The upcoming Wide-Field Upgrade (WFU) has ushered in a new era of instrumentation for the Hobby-Eberly Telescope (HET). Here, we present the design, construction progress, and lab tests completed to date of the blue-optimized second generation Low Resolution Spectrograph (LRS2-B). LRS2-B is a dual-channel, fiber fed instrument that is based on the design of the Visible Integral Field Replicable Unit Spectrograph (VIRUS), which is the new flagship instrument for carrying out the HET Dark Energy eXperiment (HETDEX). LRS2-B utilizes a microlens-coupled integral field unit (IFU) that covers a 7"x12" area on the sky having unity fill-factor with ~300 spatial elements that subsample the median HET image quality. The fiber feed assembly includes an optimized dichroic beam splitter that allows LRS2-B to simultaneously observe 370 nm to 470 nm and 460 nm to 700 nm at fixed resolving powers of R \approx 1900 and 1200, respectively. We discuss the departures from the nominal VIRUS design, which includes the IFU, fiber feed, camera correcting optics, and volume phase holographic grisms. Additionally, the motivation for the selection of the wavelength coverage and spectral resolution of the two channels is briefly discussed. One such motivation is the follow-up study of spectrally and (or) spatially resolved Lyman-alpha emission from z ~ 2.5 star-forming galaxies in the HETDEX survey. LRS2-B is planned to be a commissioning instrument for the HET WFU and should be on-sky during quarter 4 of 2013. Finally, we mention the current state of LRS2-R, the red optimized sister instrument of LRS2-B.
[2]  oai:arXiv.org:1407.6016  [pdf] - 1215849
LRS2: the new facility low resolution integral field spectrograph for the Hobby-Eberly Telescope
Comments: 26 pages, 14 figures, 3 tables. To be published in Proc. SPIE, 2014, "Ground-Based and Airborne Instrumentation for Astronomy V", 9147-9. arXiv admin note: text overlap with arXiv:1207.6118
Submitted: 2014-07-22
The second generation Low Resolution Spectrograph (LRS2) is a new facility instrument for the Hobby-Eberly Telescope (HET). Based on the design of the Visible Integral-field Replicable Unit Spectrograph (VIRUS), which is the new flagship instrument for carrying out the HET Dark Energy Experiment (HETDEX), LRS2 provides integral field spectroscopy for a seeing-limited field of 12 x 6 arcseconds. For LRS2, the replicable design of VIRUS has been leveraged to gain broad wavelength coverage from 370 nm to 1 micron, spread between two fiber-fed dual-channel spectrographs, each of which can operate as an independent instrument. The blue spectrograph, LRS2-B, covers 370-470 nm and 460-700 nm at fixed resolving powers of ~1900 and ~1100, respectively, while the red spectrograph, LRS2-R, covers 650-842 nm and 818-1050 nm with both of its channels having a resolving power of ~1800. In this paper, we present a detailed description of the instrument's design in which we focus on the departures from the basic VIRUS framework. The primary modifications include the fore-optics that are used to feed the fiber integral field units at unity fill-factor, the cameras' correcting optics and detectors, and the volume phase holographic grisms. We also present a model of the instrument's sensitivity and a description of specific science cases that have driven the design of LRS2, including systematically studying the spatially resolved properties of extended Lyman-alpha blobs at 2 < z < 3. LRS2 will provide a powerful spectroscopic follow-up platform for large surveys such as HETDEX.
[3]  oai:arXiv.org:1305.0309  [pdf] - 659091
The Influence of Motion and Stress on Optical Fibers
Comments: 19 pages, 22 figures
Submitted: 2013-05-01
We report on extensive testing carried out on the optical fibers for the VIRUS instrument. The primary result of this work explores how 10+ years of simulated wear on a VIRUS fiber bundle affects both transmission and focal ratio degradation (FRD) of the optical fibers. During the accelerated lifetime tests we continuously monitored the fibers for signs of FRD. We find that transient FRD events were common during the portions of the tests when motion was at telescope slew rates, but dropped to negligible levels during rates of motion typical for science observation. Tests of fiber transmission and FRD conducted both before and after the lifetime tests reveal that while transmission values do not change over the 10+ years of simulated wear, a clear increase in FRD is seen in all 18 fibers tested. This increase in FRD is likely due to microfractures that develop over time from repeated flexure of the fiber bundle, and stands in contrast to the transient FRD events that stem from localized stress and subsequent modal diffusion of light within the fibers. There was no measurable wavelength dependence on the increase in FRD over 350 nm to 600 nm. We also report on bend radius tests conducted on individual fibers and find the 266 microns VIRUS fibers to be immune to bending-induced FRD at bend radii of R > 10cm. Below this bend radius FRD increases slightly with decreasing radius. Lastly, we give details of a degradation seen in the fiber bundle currently deployed on the Mitchell Spectrograph (formally VIRUS-P) at McDonald Observatory. The degradation is shown to be caused by a localized shear in a select number of optical fibers that leads to an explosive form of FRD. In a few fibers, the overall transmission loss through the instrument can exceed 80%.