Normalized to: Van Weers, H.
[1]
oai:arXiv.org:1807.06092 [pdf] - 1717296
The Athena X-ray Integral Field Unit
Barret, Didier;
Trong, Thien Lam;
Herder, Jan-Willem den;
Piro, Luigi;
Cappi, Massimo;
Huovelin, Juhani;
Kelley, Richard;
Mas-Hesse, J. Miguel;
Mitsuda, Kazuhisa;
Paltani, Stéphane;
Rauw, Gregor;
Rozanska, Agata;
Wilms, Joern;
Bandler, Simon;
Barbera, Marco;
Barcons, Xavier;
Bozzo, Enrico;
Ceballos, Maria Teresa;
Charles, Ivan;
Costantini, Elisa;
Decourchelle, Anne;
Hartog, Roland den;
Duband, Lionel;
Duval, Jean-Marc;
Fiore, Fabrizio;
Gatti, Flavio;
Goldwurm, Andrea;
Jackson, Brian;
Jonker, Peter;
Kilbourne, Caroline;
Macculi, Claudio;
Mendez, Mariano;
Molendi, Silvano;
Orleanski, Piotr;
Pajot, François;
Pointecouteau, Etienne;
Porter, Frederick;
Pratt, Gabriel W.;
Prêle, Damien;
Ravera, Laurent;
Sato, Kosuke;
Schaye, Joop;
Shinozaki, Keisuke;
Thibert, Tanguy;
Valenziano, Luca;
Valette, Veronique;
Vink, Jacco;
Webb, Natalie;
Wise, Michael;
Yamasaki, Noriko;
Delcelier-Douchin, Françoise;
Mesnager, Jean-Michel;
Pontet, Bernard;
Pradines, Alice;
Branduardi-Raymont, Graziella;
Bulbul, Esra;
Dadina, Mauro;
Ettori, Stefano;
Finoguenov, Alexis;
Fukazawa, Yasushi;
Janiuk, Agnieszka;
Kaastra, Jelle;
Mazzotta, Pasquale;
Miller, Jon;
Miniutti, Giovanni;
Nazé, Yaël;
Nicastro, Fabrizio;
Sciortino, Salvatore;
Simionescu, Aurora;
Torrejon, Jose Miguel;
Frezouls, Benoît;
Geoffray, Hervé;
Peille, Philippe;
Aicardi, Corinne;
André, Jérôme;
Clénet, Antoine;
Daniel, Christophe;
Etcheverry, Christophe;
Gloaguen, Emilie;
Hervet, Gilles;
Jolly, Antoine;
Ledot, Aurélien;
Maussang, Irwin;
Paillet, Alexis;
Schmisser, Roseline;
Vella, Bruno;
Damery, Jean-Charles;
Boyce, Kevin;
DiPirro, Michael;
Lotti, Simone;
Schwander, Denis;
Smith, Stephen;
van Leeuwen, Bert-Joost;
van Weers, Henk;
Clerc, Nicolas;
Cobo, Beatriz;
Dauser, Thomas;
de Plaa, Jelle;
Kirsch, Christian;
Cucchetti, Edoardo;
Eckart, Megan;
Ferrando, Philippe;
Natalucci, Lorenzo
Submitted: 2018-07-16
The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray
spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5'
equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a
spectral resolution of 2.5 eV up to 7 keV on ~5 arcsecond pixels. The X-IFU is
based on a large format array of super-conducting molybdenum-gold Transition
Edge Sensors cooled at about 90 mK, each coupled with an absorber made of gold
and bismuth with a pitch of 249 microns. A cryogenic anti-coincidence detector
located underneath the prime TES array enables the non X-ray background to be
reduced. A bath temperature of about 50 mK is obtained by a series of
mechanical coolers combining 15K Pulse Tubes, 4K and 2K Joule-Thomson coolers
which pre-cool a sub Kelvin cooler made of a 3He sorption cooler coupled with
an Adiabatic Demagnetization Refrigerator. Frequency domain multiplexing
enables to read out 40 pixels in one single channel. A photon interacting with
an absorber leads to a current pulse, amplified by the readout electronics and
whose shape is reconstructed on board to recover its energy with high accuracy.
The defocusing capability offered by the Athena movable mirror assembly enables
the X-IFU to observe the brightest X-ray sources of the sky (up to Crab-like
intensities) by spreading the telescope point spread function over hundreds of
pixels. Thus the X-IFU delivers low pile-up, high throughput (>50%), and
typically 10 eV spectral resolution at 1 Crab intensities, i.e. a factor of 10
or more better than Silicon based X-ray detectors. In this paper, the current
X-IFU baseline is presented, together with an assessment of its anticipated
performance in terms of spectral resolution, background, and count rate
capability. The X-IFU baseline configuration will be subject to a preliminary
requirement review that is scheduled at the end of 2018.
[2]
oai:arXiv.org:1803.10438 [pdf] - 1747876
SPICA - a large cryogenic infrared space telescope Unveiling the
obscured Universe
Roelfsema, P. R.;
Shibai, H.;
Armus, L.;
Arrazola, D.;
Audard, M.;
Audley, M. D.;
Bradford, C. M.;
Charles, I.;
Dieleman, P.;
Doi, Y.;
Duband, L.;
Eggens, M.;
Evers, J.;
Funaki, I.;
Gao, J. R.;
Giard, M.;
Fernández, A. di Giorgio L. M. González;
Griffin, M.;
Helmich, F. P.;
Hijmering, R.;
Huisman, R.;
Ishihara, D.;
Isobe, N.;
Jackson, B.;
Jacobs, H.;
Jellema, W.;
Kamp, I.;
Kaneda, H.;
Kawada, M.;
Kemper, F.;
Kerschbaum, F.;
Khosropanah, P.;
Kohno, K.;
Kooijman, P. P.;
Krause, O.;
van der Kuur, J.;
Kwon, J.;
Laauwen, W. M.;
de Lange, G.;
Larsson, B.;
van Loon, D.;
Madden, S. C.;
Matsuhara, H.;
Najarro, F.;
Nakagawa, T.;
Naylor, D.;
Ogawa, H.;
Onaka, T.;
Oyabu, S.;
Poglitsch, A.;
Reveret, V.;
Rodriguez, L.;
Spinoglio, L.;
Sakon, I.;
Sato, Y.;
Shinozaki, K.;
Shipman, R.;
Sugita, H.;
Suzuki, T.;
van der Tak, F. F. S.;
Redondo, J. Torres;
Wada, T.;
Wang, S. Y.;
Wafelbakker, C. K.;
van Weers, H.;
Withington, S.;
Vandenbussche, B.;
Yamada, T.;
Yamamura, I.
Submitted: 2018-03-28
Measurements in the infrared wavelength domain allow us to assess directly
the physical state and energy balance of cool matter in space, thus enabling
the detailed study of the various processes that govern the formation and early
evolution of stars and planetary systems in galaxies over cosmic time. Previous
infrared missions, from IRAS to Herschel, have revealed a great deal about the
obscured Universe, but sensitivity has been limited because up to now it has
not been possible to fly a telescope that is both large and cold.
SPICA is a mission concept aimed at taking the next step in mid- and
far-infrared observational capability by combining a large and cold telescope
with instruments employing state-of-the-art ultra-sensitive detectors. The
mission concept foresees a 2.5-meter diameter telescope cooled to below 8 K.
With cooling provided by mechanical coolers instead of depending on a limited
cryogen supply, the mission lifetime can extend significantly beyond the
required three years.
SPICA offers instrumentation with spectral resolving powers ranging from R
~50 through 11000 in the 17-230 $\mu$m domain as well as R~28.000 spectroscopy
between 12 and 18 $\mu$m. Additionally SPICA will provide efficient 30-37
$\mu$m broad band mapping, and polarimetric imaging in the 100-350 $\mu$m
range. SPICA will provide unprecedented spectroscopic sensitivity of ~5 x
$10^{-20}$ W/m$^2$ (5$\sigma$/1hr) - at least two orders of magnitude
improvement over what has been attained to date.
With this exceptional leap in performance, new domains in infrared astronomy
will become accessible, allowing us, for example, to unravel definitively
galaxy evolution and metal production over cosmic time, to study dust formation
and evolution from very early epochs onwards, and to trace the formation
history of planetary systems.
[3]
oai:arXiv.org:1608.08105 [pdf] - 1467926
The Athena X-ray Integral Field Unit (X-IFU)
Barret, Didier;
Trong, Thien Lam;
Herder, Jan-Willem den;
Piro, Luigi;
Barcons, Xavier;
Huovelin, Juhani;
Kelley, Richard;
Mas-Hesse, J. Miguel;
Mitsuda, Kazuhisa;
Paltani, Stéphane;
Rauw, Gregor;
Rożanska, Agata;
Wilms, Joern;
Barbera, Marco;
Bozzo, Enrico;
Ceballos, Maria Teresa;
Charles, Ivan;
Decourchelle, Anne;
Hartog, Roland den;
Duval, Jean-Marc;
Fiore, Fabrizio;
Gatti, Flavio;
Goldwurm, Andrea;
Jackson, Brian;
Jonker, Peter;
Kilbourne, Caroline;
Macculi, Claudio;
Mendez, Mariano;
Molendi, Silvano;
Orleanski, Piotr;
Pajot, François;
Pointecouteau, Etienne;
Porter, Frederick;
Pratt, Gabriel W.;
Prêle, Damien;
Ravera, Laurent;
Renotte, Etienne;
Schaye, Joop;
Shinozaki, Keisuke;
Valenziano, Luca;
Vink, Jacco;
Webb, Natalie;
Yamasaki, Noriko;
Delcelier-Douchin, Françoise;
Du, Michel Le;
Mesnager, Jean-Michel;
Pradines, Alice;
Branduardi-Raymont, Graziella;
Dadina, Mauro;
Finoguenov, Alexis;
Fukazawa, Yasushi;
Janiuk, Agnieszka;
Miller, Jon;
Nazé, Yaël;
Nicastro, Fabrizio;
Sciortino, Salvatore;
Torrejon, Jose Miguel;
Geoffray, Hervé;
Hernandez, Isabelle;
Luno, Laure;
Peille, Philippe;
André, Jérôme;
Daniel, Christophe;
Etcheverry, Christophe;
Gloaguen, Emilie;
Hassin, Jérémie;
Hervet, Gilles;
Maussang, Irwin;
Moueza, Jérôme;
Paillet, Alexis;
Vella, Bruno;
Garrido, Gonzalo Campos;
Damery, Jean-Charles;
Panem, Chantal;
Panh, Johan;
Bandler, Simon;
Biffi, Jean-Marc;
Boyce, Kevin;
Clénet, Antoine;
DiPirro, Michael;
Jamotton, Pierre;
Lotti, Simone;
Schwander, Denis;
Smith, Stephen;
van Leeuwen, Bert-Joost;
van Weers, Henk;
Brand, Thorsten;
Cobo, Beatriz;
Dauser, Thomas;
de Plaa, Jelle;
Cucchetti, Edoardo
Submitted: 2016-08-29
The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for
High-ENergy Astrophysics (Athena) will provide spatially resolved
high-resolution X-ray spectroscopy from 0.2 to 12 keV, with 5 arc second pixels
over a field of view of 5 arc minute equivalent diameter and a spectral
resolution of 2.5 eV up to 7 keV. In this paper, we first review the core
scientific objectives of Athena, driving the main performance parameters of the
X-IFU, namely the spectral resolution, the field of view, the effective area,
the count rate capabilities, the instrumental background. We also illustrate
the breakthrough potential of the X-IFU for some observatory science goals.
Then we briefly describe the X-IFU design as defined at the time of the mission
consolidation review concluded in May 2016, and report on its predicted
performance. Finally, we discuss some options to improve the instrument
performance while not increasing its complexity and resource demands (e.g.
count rate capability, spectral resolution).
The X-IFU will be provided by an international consortium led by France, The
Netherlands and Italy, with further ESA member state contributions from
Belgium, Finland, Germany, Poland, Spain, Switzerland and two international
partners from the United States and Japan.
[4]
oai:arXiv.org:1604.00670 [pdf] - 1489757
Development of the superconducting detectors and read-out for the X-IFU
instrument on board of the X-ray observatory Athena
Submitted: 2016-04-03
The Advanced Telescope for High-Energy Astrophysics (Athena) has been
selected by ESA as its second large-class mission. The future European X-ray
observatory will study the hot and energetic Universe with its launch foreseen
in 2028. Microcalorimeters based on superconducting Transition-edge sensor
(TES) are the chosen technology for the detectors array of the X-ray Integral
Field Unit (X-IFU) on board of Athena. The X-IFU is a 2-D imaging
integral-field spectrometer operating in the soft X-ray band (0.3 -12 keV). The
detector consists of an array of 3840 TESs coupled to X-ray absorbers and read
out in the MHz bandwidth using Frequency Domain Multiplexing (FDM) based on
Superconducting QUantum Interference Devices (SQUIDs). The proposed design
calls for devices with a high filling-factor, high quantum efficiency,
relatively high count-rate capability and an energy resolution of 2.5 eV at 5.9
keV. The paper will review the basic principle and the physics of the TES-based
microcalorimeters and present the state-of-the art of the FDM read-out.
[5]
oai:arXiv.org:1308.6784 [pdf] - 713384
The Hot and Energetic Universe: The X-ray Integral Field Unit (X-IFU)
for Athena+
Barret, D.;
Herder, J. W. den;
Piro, L.;
Ravera, L.;
Hartog, R. Den;
Macculi, C.;
Barcons, X.;
Page, M.;
Paltani, S.;
Rauw, G.;
Wilms, J.;
Ceballos, M.;
Duband, L.;
Gottardi, L.;
Lotti, S.;
de Plaa, J.;
Pointecouteau, E.;
Schmid, C.;
Akamatsu, H.;
Bagliani, D.;
Bandler, S.;
Barbera, M.;
Bastia, P.;
Biasotti, M.;
Branco, M.;
Camon, A.;
Cara, C.;
Cobo, B.;
Colasanti, L.;
Costa-Kramer, J. L.;
Corcione, L.;
Doriese, W.;
Duval, J. M.;
Fabrega, L.;
Gatti, F.;
de Gerone, M.;
Guttridge, P.;
Kelley, R.;
Kilbourne, C.;
van der Kuur, J.;
Mineo, T.;
Mitsuda, K.;
Natalucci, L.;
Ohashi, T.;
Peille, P.;
Perinati, E.;
Pigot, C.;
Pizzigoni, G.;
Pobes, C.;
Porter, F.;
Renotte, E.;
Sauvageot, J. L.;
Sciortino, S.;
Torrioli, G.;
Valenziano, L.;
Willingale, D.;
de Vries, C.;
van Weers, H.
Submitted: 2013-08-30
The Athena+ mission concept is designed to implement the Hot and Energetic
Universe science theme submitted to the European Space Agency in response to
the call for White Papers for the definition of the L2 and L3 missions of its
science program. The Athena+ science payload consists of a large aperture high
angular resolution X-ray optics and twelve meters away, two interchangeable
focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide
Field Imager (WFI). The X-IFU is a cryogenic X-ray spectrometer, based on a
large array of Transition Edge Sensors (TES), offering 2.5 eV spectral
resolution, with ~5" pixels, over a field of view of 5 arc minutes in diameter.
In this paper, we briefly describe the Athena+ mission concept and the X-IFU
performance requirements. We then present the X-IFU detector and readout
electronics principles, the current design of the focal plane assembly, the
cooling chain and review the global architecture design. Finally, we describe
the current performance estimates, in terms of effective area, particle
background rejection, count rate capability and velocity measurements. Finally,
we emphasize on the latest technology developments concerning TES array
fabrication, spectral resolution and readout performance achieved to show that
significant progresses are being accomplished towards the demanding X-IFU
requirements.