Normalized to: Van Leeuwen, B.
[1]
oai:arXiv.org:1807.06092 [pdf] - 1717296
The Athena X-ray Integral Field Unit
Barret, Didier;
Trong, Thien Lam;
Herder, Jan-Willem den;
Piro, Luigi;
Cappi, Massimo;
Huovelin, Juhani;
Kelley, Richard;
Mas-Hesse, J. Miguel;
Mitsuda, Kazuhisa;
Paltani, Stéphane;
Rauw, Gregor;
Rozanska, Agata;
Wilms, Joern;
Bandler, Simon;
Barbera, Marco;
Barcons, Xavier;
Bozzo, Enrico;
Ceballos, Maria Teresa;
Charles, Ivan;
Costantini, Elisa;
Decourchelle, Anne;
Hartog, Roland den;
Duband, Lionel;
Duval, Jean-Marc;
Fiore, Fabrizio;
Gatti, Flavio;
Goldwurm, Andrea;
Jackson, Brian;
Jonker, Peter;
Kilbourne, Caroline;
Macculi, Claudio;
Mendez, Mariano;
Molendi, Silvano;
Orleanski, Piotr;
Pajot, François;
Pointecouteau, Etienne;
Porter, Frederick;
Pratt, Gabriel W.;
Prêle, Damien;
Ravera, Laurent;
Sato, Kosuke;
Schaye, Joop;
Shinozaki, Keisuke;
Thibert, Tanguy;
Valenziano, Luca;
Valette, Veronique;
Vink, Jacco;
Webb, Natalie;
Wise, Michael;
Yamasaki, Noriko;
Delcelier-Douchin, Françoise;
Mesnager, Jean-Michel;
Pontet, Bernard;
Pradines, Alice;
Branduardi-Raymont, Graziella;
Bulbul, Esra;
Dadina, Mauro;
Ettori, Stefano;
Finoguenov, Alexis;
Fukazawa, Yasushi;
Janiuk, Agnieszka;
Kaastra, Jelle;
Mazzotta, Pasquale;
Miller, Jon;
Miniutti, Giovanni;
Nazé, Yaël;
Nicastro, Fabrizio;
Sciortino, Salvatore;
Simionescu, Aurora;
Torrejon, Jose Miguel;
Frezouls, Benoît;
Geoffray, Hervé;
Peille, Philippe;
Aicardi, Corinne;
André, Jérôme;
Clénet, Antoine;
Daniel, Christophe;
Etcheverry, Christophe;
Gloaguen, Emilie;
Hervet, Gilles;
Jolly, Antoine;
Ledot, Aurélien;
Maussang, Irwin;
Paillet, Alexis;
Schmisser, Roseline;
Vella, Bruno;
Damery, Jean-Charles;
Boyce, Kevin;
DiPirro, Michael;
Lotti, Simone;
Schwander, Denis;
Smith, Stephen;
van Leeuwen, Bert-Joost;
van Weers, Henk;
Clerc, Nicolas;
Cobo, Beatriz;
Dauser, Thomas;
de Plaa, Jelle;
Kirsch, Christian;
Cucchetti, Edoardo;
Eckart, Megan;
Ferrando, Philippe;
Natalucci, Lorenzo
Submitted: 2018-07-16
The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray
spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5'
equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a
spectral resolution of 2.5 eV up to 7 keV on ~5 arcsecond pixels. The X-IFU is
based on a large format array of super-conducting molybdenum-gold Transition
Edge Sensors cooled at about 90 mK, each coupled with an absorber made of gold
and bismuth with a pitch of 249 microns. A cryogenic anti-coincidence detector
located underneath the prime TES array enables the non X-ray background to be
reduced. A bath temperature of about 50 mK is obtained by a series of
mechanical coolers combining 15K Pulse Tubes, 4K and 2K Joule-Thomson coolers
which pre-cool a sub Kelvin cooler made of a 3He sorption cooler coupled with
an Adiabatic Demagnetization Refrigerator. Frequency domain multiplexing
enables to read out 40 pixels in one single channel. A photon interacting with
an absorber leads to a current pulse, amplified by the readout electronics and
whose shape is reconstructed on board to recover its energy with high accuracy.
The defocusing capability offered by the Athena movable mirror assembly enables
the X-IFU to observe the brightest X-ray sources of the sky (up to Crab-like
intensities) by spreading the telescope point spread function over hundreds of
pixels. Thus the X-IFU delivers low pile-up, high throughput (>50%), and
typically 10 eV spectral resolution at 1 Crab intensities, i.e. a factor of 10
or more better than Silicon based X-ray detectors. In this paper, the current
X-IFU baseline is presented, together with an assessment of its anticipated
performance in terms of spectral resolution, background, and count rate
capability. The X-IFU baseline configuration will be subject to a preliminary
requirement review that is scheduled at the end of 2018.
[2]
oai:arXiv.org:1611.05268 [pdf] - 1515839
Optimising the multiplex factor of the frequency domain multiplexed
readout of the TES-based microcalorimeter imaging array for the X-IFU
instrument on the Athena Xray observatory
Submitted: 2016-11-16
Athena is a space-based X-ray observatory intended for exploration of the hot
and energetic universe. One of the science instruments on Athena will be the
X-ray Integrated Field Unit (X-IFU), which is a cryogenic X-ray spectrometer,
based on a large cryogenic imaging array of Transition Edge Sensors (TES) based
microcalorimeters operating at a temperature of 100mK. The imaging array
consists of 3800 pixels providing 2.5 eV spectral resolution, and covers a
field of view with a diameter of of 5 arc minutes. Multiplexed readout of the
cryogenic microcalorimeter array is essential to comply with the cooling power
and complexity constraints on a space craft. Frequency domain multiplexing has
been under development for the readout of TES-based detectors for this purpose,
not only for the X-IFU detector arrays but also for TES-based bolometer arrays
for the Safari instrument of the Japanese SPICA observatory. This paper
discusses the design considerations which are applicable to optimise the
multiplex factor within the boundary conditions as set by the space craft. More
specifically, the interplay between the science requirements such as pixel
dynamic range, pixel speed, and cross talk, and the space craft requirements
such as the power dissipation budget, available bandwidth, and electromagnetic
compatibility will be discussed.
[3]
oai:arXiv.org:1608.08105 [pdf] - 1467926
The Athena X-ray Integral Field Unit (X-IFU)
Barret, Didier;
Trong, Thien Lam;
Herder, Jan-Willem den;
Piro, Luigi;
Barcons, Xavier;
Huovelin, Juhani;
Kelley, Richard;
Mas-Hesse, J. Miguel;
Mitsuda, Kazuhisa;
Paltani, Stéphane;
Rauw, Gregor;
Rożanska, Agata;
Wilms, Joern;
Barbera, Marco;
Bozzo, Enrico;
Ceballos, Maria Teresa;
Charles, Ivan;
Decourchelle, Anne;
Hartog, Roland den;
Duval, Jean-Marc;
Fiore, Fabrizio;
Gatti, Flavio;
Goldwurm, Andrea;
Jackson, Brian;
Jonker, Peter;
Kilbourne, Caroline;
Macculi, Claudio;
Mendez, Mariano;
Molendi, Silvano;
Orleanski, Piotr;
Pajot, François;
Pointecouteau, Etienne;
Porter, Frederick;
Pratt, Gabriel W.;
Prêle, Damien;
Ravera, Laurent;
Renotte, Etienne;
Schaye, Joop;
Shinozaki, Keisuke;
Valenziano, Luca;
Vink, Jacco;
Webb, Natalie;
Yamasaki, Noriko;
Delcelier-Douchin, Françoise;
Du, Michel Le;
Mesnager, Jean-Michel;
Pradines, Alice;
Branduardi-Raymont, Graziella;
Dadina, Mauro;
Finoguenov, Alexis;
Fukazawa, Yasushi;
Janiuk, Agnieszka;
Miller, Jon;
Nazé, Yaël;
Nicastro, Fabrizio;
Sciortino, Salvatore;
Torrejon, Jose Miguel;
Geoffray, Hervé;
Hernandez, Isabelle;
Luno, Laure;
Peille, Philippe;
André, Jérôme;
Daniel, Christophe;
Etcheverry, Christophe;
Gloaguen, Emilie;
Hassin, Jérémie;
Hervet, Gilles;
Maussang, Irwin;
Moueza, Jérôme;
Paillet, Alexis;
Vella, Bruno;
Garrido, Gonzalo Campos;
Damery, Jean-Charles;
Panem, Chantal;
Panh, Johan;
Bandler, Simon;
Biffi, Jean-Marc;
Boyce, Kevin;
Clénet, Antoine;
DiPirro, Michael;
Jamotton, Pierre;
Lotti, Simone;
Schwander, Denis;
Smith, Stephen;
van Leeuwen, Bert-Joost;
van Weers, Henk;
Brand, Thorsten;
Cobo, Beatriz;
Dauser, Thomas;
de Plaa, Jelle;
Cucchetti, Edoardo
Submitted: 2016-08-29
The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for
High-ENergy Astrophysics (Athena) will provide spatially resolved
high-resolution X-ray spectroscopy from 0.2 to 12 keV, with 5 arc second pixels
over a field of view of 5 arc minute equivalent diameter and a spectral
resolution of 2.5 eV up to 7 keV. In this paper, we first review the core
scientific objectives of Athena, driving the main performance parameters of the
X-IFU, namely the spectral resolution, the field of view, the effective area,
the count rate capabilities, the instrumental background. We also illustrate
the breakthrough potential of the X-IFU for some observatory science goals.
Then we briefly describe the X-IFU design as defined at the time of the mission
consolidation review concluded in May 2016, and report on its predicted
performance. Finally, we discuss some options to improve the instrument
performance while not increasing its complexity and resource demands (e.g.
count rate capability, spectral resolution).
The X-IFU will be provided by an international consortium led by France, The
Netherlands and Italy, with further ESA member state contributions from
Belgium, Finland, Germany, Poland, Spain, Switzerland and two international
partners from the United States and Japan.