van Harten, G.
Normalized to: Van Harten, G.
6 article(s) in total. 17 co-authors, from 1 to 5 common article(s). Median position in authors list is 3,5.
[1]
oai:arXiv.org:1710.06067 [pdf] - 1589895
Polarization Modeling and Predictions for DKIST Part 2: Application of
the Berreman Calculus to Spectral Polarization Fringes of Beamsplitters and
Crystal Retarders
Submitted: 2017-10-16
We outline polarization fringe predictions derived from a new application of
the Berreman calculus for the Daniel K. Inouye Solar Telescope (DKIST) retarder
optics. The DKIST retarder baseline design used 6 crystals, single-layer
anti-reflection coatings, thick cover windows and oil between all optical
interfaces. This new tool estimates polarization fringes and optic Mueller
matrices as functions of all optical design choices. The amplitude and period
of polarized fringes under design changes, manufacturing errors, tolerances and
several physical factors can now be estimated. This tool compares well with
observations of fringes for data collected with the SPINOR spectropolarimeter
at the Dunn Solar Telescope using bi-crystalline achromatic retarders as well
as laboratory tests. With this new tool, we show impacts of design decisions on
polarization fringes as impacted by anti-reflection coatings, oil refractive
indices, cover window presence and part thicknesses. This tool helped DKIST
decide to remove retarder cover windows and also recommends reconsideration of
coating strategies for DKIST. We anticipate this tool to be essential in
designing future retarders for mitigation of polarization and intensity fringe
errors in other high spectral resolution astronomical systems.
[2]
oai:arXiv.org:1502.00856 [pdf] - 1504413
Preliminary design of the full-Stokes UV and visible spectropolarimeter
for UVMag/Arago
Submitted: 2015-02-03
The UVMag consortium proposed the space mission project Arago to ESA at its
M4 call. It is dedicated to the study of the dynamic 3D environment of stars
and planets. This space mission will be equipped with a high-resolution
spectropolarimeter working from 119 to 888 nm. A preliminary optical design of
the whole instrument has been prepared and is presented here. The design
consists of the telescope, the instrument itself, and the focusing optics.
Considering not only the scientific requirements, but also the cost and size
constraints to fit a M-size mission, the telescope has a 1.3 m diameter primary
mirror and is a classical Cassegrain-type telescope that allows a
polarization-free focus. The polarimeter is placed at this Cassegrain focus.
This is the key element of the mission and the most challenging to be designed.
The main challenge lies in the huge spectral range offered by the instrument;
the polarimeter has to deliver the full Stokes vector with a high precision
from the FUV (119 nm) to the NIR (888 nm). The polarimeter module is then
followed by a high-resolution echelle-spectrometer achieving a resolution of
35000 in the visible range and 25000 in the UV. The two channels are separated
after the echelle grating, allowing a specific cross-dispersion and focusing
optics for the UV and visible ranges. Considering the large field of view and
the high numerical aperture, the focusing optic for both the UV and visible
channels is a Three-Mirror-Anastigmat (TMA) telescope, in order to focus the
various wavelengths and many orders onto the detectors.
[3]
oai:arXiv.org:1406.4378 [pdf] - 1215024
UVMag: Space UV and visible spectropolarimetry
Submitted: 2014-06-17, last modified: 2014-07-23
UVMag is a project of a space mission equipped with a high-resolution
spectropolarimeter working in the UV and visible range. This M-size mission
will be proposed to ESA at its M4 call. The main goal of UVMag is to measure
the magnetic fields, winds and environment of all types of stars to reach a
better understanding of stellar formation and evolution and of the impact of
stellar environment on the surrounding planets. The groundbreaking combination
of UV and visible spectropolarimetric observations will allow the scientists to
study the stellar surface and its environment simultaneously. The instrumental
challenge for this mission is to design a high-resolution space
spectropolarimeter measuring the full-Stokes vector of the observed star in a
huge spectral domain from 117 nm to 870 nm. This spectral range is the main
difficulty because of the dispersion of the optical elements and of
birefringence issues in the FUV. As the instrument will be launched into space,
the polarimetric module has to be robust and therefore use if possible only
static elements. This article presents the different design possibilities for
the polarimeter at this point of the project.
[4]
oai:arXiv.org:1407.5784 [pdf] - 854704
Exact Bound-Bound Gaunt Factor Values for Quantum Levels up to n=2000
Submitted: 2014-07-22
Comparison of observations of radio recombination lines in the interstellar
medium with theoretical models can be used to constrain electron temperature
and density of the gas. An important component of the models is spontaneous
transition rates between bound levels. Calculating these rates relies on
accurate bound-bound oscillator strengths, which can be cast in terms of the
Gaunt factor. The Gaunt factor contains terminating hypergeometric functions
that cannot be calculated with sufficient accuracy for high quantum levels ($n
\gtrsim 50$) by standard machine-precision methods. Methods to overcome the
accuracy problem have been developed, which include asymptotic expansions and
recursion relations. These methods, used in astrophysical models to calculate
oscillator strengths, can introduce errors, sometimes up to as much as $\sim 8$
per cent. Detections of radio recombination lines with the new Low Frequency
Array (LOFAR) has prompted an examination of theoretical models of the
interstellar medium. We revisit the calculation of the Gaunt factor, employing
modern arbitrary-precision computational methods to tabulate the Gaunt factor
for transitions up to quantum level $n=2000$, sufficient to model low frequency
Carbon radio recombination lines. The calculations provide a relative error of
$\sim3\times 10^{-4}$ when compared to more detailed calculations including
relativistic corrections. Our values for the Gaunt factor are provided for
download in a tabular format to be used for a wide range of applications.
[5]
oai:arXiv.org:1207.2965 [pdf] - 1124792
Design of a Full-Stokes Polarimeter for VLT/X-shooter
Submitted: 2012-07-12
X-shooter is one of the most popular instruments at the VLT, offering
instantaneous spectroscopy from 300 to 2500 nm. We present the design of a
single polarimetric unit at the polarization-free Cassegrain focus that serves
all three spectrograph arms of X-shooter. It consists of a calcite Savart plate
as a polarizing beam-splitter and a rotatable crystal retarder stack as a
"polychromatic modulator". Since even "superachromatic" wave plates have a
wavelength range that is too limited for X-shooter, this novel modulator is
designed to offer close-to-optimal polarimetric efficiencies for all Stokes
parameters at all wavelengths. We analyze the modulator design in terms of its
polarimetric performance, its temperature sensitivity, and its polarized
fringes. Furthermore, we present the optical design of the polarimetric unit.
The X-shooter polarimeter will furnish a myriad of science cases: from
measuring stellar magnetic fields (e.g., Ap stars, white dwarfs, massive stars)
to determining asymmetric structures around young stars and in supernova
explosions.
[6]
oai:arXiv.org:0903.2740 [pdf] - 1001655
Polarization properties of real aluminum mirrors; I. Influence of the
aluminum oxide layer
Submitted: 2009-03-16
In polarimetry it is important to characterize the polarization properties of
the instrument itself to disentangle real astrophysical signals from
instrumental effects. This article deals with the accurate measurement and
modeling of the polarization properties of real aluminum mirrors, as used in
astronomical telescopes. Main goals are the characterization of the aluminum
oxide layer thickness at different times after evaporation and its influence on
the polarization properties of the mirror. The full polarization properties of
an aluminum mirror are measured with Mueller matrix ellipsometry at different
incidence angles and wavelengths. The best fit of theoretical Mueller matrices
to all measurements simultaneously is obtained by taking into account a model
of bulk aluminum with a thin aluminum oxide film on top of it. Full Mueller
matrix measurements of a mirror are obtained with an absolute accuracy of ~1%
after calibration. The determined layer thicknesses indicate logarithmic growth
in the first few hours after evaporation, but it remains stable at a value of
4.12+/-0.08 nm on the long term. Although the aluminum oxide layer is
established to be thin, it is necessary to consider it to accurately describe
the mirror's polarization properties.