sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

van der Linden, Anton J.

Normalized to: Van der Linden, A.

3 article(s) in total. 17 co-authors, from 1 to 3 common article(s). Median position in authors list is 10,0.

[1]  oai:arXiv.org:1604.02600  [pdf] - 1388309
A multiplexer for the ac/dc characterization of TES based bolometers and microcalorimeters
Comments: 7 pages, 6 figures, Proc. SPIE 8453, High Energy, Optical, and Infrared Detectors for Astronomy V, 845333 (25 September 2012). arXiv admin note: text overlap with arXiv:1604.02593
Submitted: 2016-04-09
At SRON we are developing the Frequency Domain Multiplexing (FDM) for the read-out of the TES-based detector array for the future infrared and X-ray space mission. We describe the performances of a multiplexer designed to increase the experimental throughput in the characterisation of ultra-low noise equivalent power (NEP) TES bolometers and high energy resolving power X-ray microcalorimeters arrays under ac and dc bias. We discuss the results obtained using the TiAu TES bolometers array fabricated at SRON with measured dark NEP below $5\cdot 10^{-19}W/Hz^{1/2}$ and saturation power of several fW
[2]  oai:arXiv.org:1604.00680  [pdf] - 1384872
Weak-Link Phenomena in AC-Biased Transition Edge Sensors
Comments: 6 pages, 5 figure
Submitted: 2016-04-03
It has been recently demonstrated that superconducting transition edge sensors (TESs) behave as weak-links due to longitudinally induced superconductivity from the leads with higher Tc. In this work we study the implication of this behaviour for TES-based bolometers and microcalorimeter under ac bias. The TESs are read-out at frequencies between 1 and 5 MHz by a Frequency Domain Multiplexer based on a linearised two-stage SQUID amplifier and high- Q lithographically made superconducting LC resonators. In particular, we focus on SRON TiAu TES bolometers with a measured dark Noise Equivalent Power (NEP) of $3.2 \cdot 10^{-19} W/Hz^{1/2}$ developed for the short wavelength band for the instrument SAFARI on the SPICA telescope.
[3]  oai:arXiv.org:1604.00553  [pdf] - 1384861
Development of TES-based detectors array for the X-ray Integral Field Unit (X-IFU) on the future x-ray observatory ATHENA
Comments: 9 pages, 8 figures
Submitted: 2016-04-02
We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m squared, AuBi absorbers. We designed and fabricated devices with different contact geometries between the absorber and the TES to optimise the detector performance and with different wiring topology to mitigate the self-magnetic field. The design is tailored to optimise the performance under Frequency Domain Multiplexing. In this paper we review the main design feature of the pixels array and we report on the performance of the 18 channels, 2-5MHz frequency domain multiplexer that will be used to characterised the detector array.