van der Linden, Anton J.
Normalized to: Van der Linden, A.
3 article(s) in total. 17 co-authors, from 1 to 3 common article(s). Median position in authors list is 10,0.
[1]
oai:arXiv.org:1604.02600 [pdf] - 1388309
A multiplexer for the ac/dc characterization of TES based bolometers and
microcalorimeters
Gottardi, Luciano;
Akamatsu, Hiroki;
Bruijn, Marcel;
Gao, Jan R.;
Hartog, Roland den;
Hijmering, Richard;
Hoevers, Henk;
Khosropanah, Pourya;
van der Kuur, Jan;
van der Linden, Anoton;
Lindeman, Marcel;
Ridder, Marcel
Submitted: 2016-04-09
At SRON we are developing the Frequency Domain Multiplexing (FDM) for the
read-out of the TES-based detector array for the future infrared and X-ray
space mission. We describe the performances of a multiplexer designed to
increase the experimental throughput in the characterisation of ultra-low noise
equivalent power (NEP) TES bolometers and high energy resolving power X-ray
microcalorimeters arrays under ac and dc bias. We discuss the results obtained
using the TiAu TES bolometers array fabricated at SRON with measured dark NEP
below $5\cdot 10^{-19}W/Hz^{1/2}$ and saturation power of several fW
[2]
oai:arXiv.org:1604.00680 [pdf] - 1384872
Weak-Link Phenomena in AC-Biased Transition Edge Sensors
Gottardi, Luciano;
Akamatsu, Hiroki;
Bruijn, Marcel;
Gao, Jan-R.;
Hartog, Roland den;
Hijmering, Richard;
Hoevers, Henk;
Khosropanah, Pourya;
Kozorezov, Alex;
van der Kuur, Jan;
van der Linden, Anton;
Ridder, Marcel
Submitted: 2016-04-03
It has been recently demonstrated that superconducting transition edge
sensors (TESs) behave as weak-links due to longitudinally induced
superconductivity from the leads with higher Tc. In this work we study the
implication of this behaviour for TES-based bolometers and microcalorimeter
under ac bias. The TESs are read-out at frequencies between 1 and 5 MHz by a
Frequency Domain Multiplexer based on a linearised two-stage SQUID amplifier
and high- Q lithographically made superconducting LC resonators. In particular,
we focus on SRON TiAu TES bolometers with a measured dark Noise Equivalent
Power (NEP) of $3.2 \cdot 10^{-19} W/Hz^{1/2}$ developed for the short
wavelength band for the instrument SAFARI on the SPICA telescope.
[3]
oai:arXiv.org:1604.00553 [pdf] - 1384861
Development of TES-based detectors array for the X-ray Integral Field
Unit (X-IFU) on the future x-ray observatory ATHENA
Gottardi, Luciano;
Akamatsu, Hiroki;
Barret, Didier;
Bruijn, Marcel P.;
Hartog, Roland H. den;
Herder, Jan-Willem den;
Hoevers, Henk F. C.;
Kiviranta, Mikko;
van der Kuur, Jan;
van der Linden, Anton J.;
Jackson, Brian D.;
Jambunathan, Madu;
Ridder, Marcel L.
Submitted: 2016-04-02
We are developing transition-edge sensor (TES)-based microcalorimeters for
the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory
Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m
squared, AuBi absorbers. We designed and fabricated devices with different
contact geometries between the absorber and the TES to optimise the detector
performance and with different wiring topology to mitigate the self-magnetic
field. The design is tailored to optimise the performance under Frequency
Domain Multiplexing. In this paper we review the main design feature of the
pixels array and we report on the performance of the 18 channels, 2-5MHz
frequency domain multiplexer that will be used to characterised the detector
array.