sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

van der Kuur, J.

Normalized to: Van der Kuur, J.

12 article(s) in total. 144 co-authors, from 1 to 10 common article(s). Median position in authors list is 8,5.

[1]  oai:arXiv.org:2003.11899  [pdf] - 2070581
Progress in the development of frequency domain multiplexing for the X-ray Integral Field Unit on board the Athena mission
Comments: 7 pages, 5 figures. Published on Journal of Low Temperature Physics (2020)
Submitted: 2020-03-26
Frequency domain multiplexing (FDM) is the baseline readout system for the X-ray Integral Field Unit (X-IFU) on board the Athena mission. Under the FDM scheme, TESs are coupled to a passive LC filter and biased with alternating current (AC bias) at MHz frequencies. Using high-quality factor LC filters and room temperature electronics developed at SRON and low-noise two-stage SQUID amplifiers provided by VTT, we have recently demonstrated good performance with the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. We have achieved a performance requested for the demonstration model (DM) with the single pixel AC bias ($\Delta E=$1.8 eV) and 9 pixel multiplexing ($\Delta E=$2.6 eV) modes. We have also demonstrated 14-pixel multiplexing with an average energy resolution of 3.3 eV, which is limited by non-fundamental issues related to FDM readout in our lab setup.
[2]  oai:arXiv.org:1810.09122  [pdf] - 1770848
Two SQUID amplifiers intended to alleviate the summing node inductance problem in multiplexed arrays of Transition Edge Sensors
Comments: 6 pages, 7 figures
Submitted: 2018-10-22
Frequency Domain Multiplexed detector arrays constructed of superconducting Transition Edge Sensors in the current-summing configuration suffer from the finite impedance of the summing node which should ideally be zero. We suggest two circuits to alleviate the effect. The first circuit uses a capacitive resonant transformer to increase the voltages and decrease the currents of TES signals to overcome the parasitic inductance of the interconnections. On the SQUID chip impedance transform to the opposite direction takes place. The second circuit implements a power combiner having a better branch-to-branch isolation than a simple T-junction. Two SQUID devices have been designed and fabricated for a proof-of-principle demonstration of the circuits.
[3]  oai:arXiv.org:1803.10438  [pdf] - 1747876
SPICA - a large cryogenic infrared space telescope Unveiling the obscured Universe
Comments: 34 pages, 22 figures, paper accepted for publication in PASA on 2nd February 2018, part of the PASA SPICA Special Issue
Submitted: 2018-03-28
Measurements in the infrared wavelength domain allow us to assess directly the physical state and energy balance of cool matter in space, thus enabling the detailed study of the various processes that govern the formation and early evolution of stars and planetary systems in galaxies over cosmic time. Previous infrared missions, from IRAS to Herschel, have revealed a great deal about the obscured Universe, but sensitivity has been limited because up to now it has not been possible to fly a telescope that is both large and cold. SPICA is a mission concept aimed at taking the next step in mid- and far-infrared observational capability by combining a large and cold telescope with instruments employing state-of-the-art ultra-sensitive detectors. The mission concept foresees a 2.5-meter diameter telescope cooled to below 8 K. With cooling provided by mechanical coolers instead of depending on a limited cryogen supply, the mission lifetime can extend significantly beyond the required three years. SPICA offers instrumentation with spectral resolving powers ranging from R ~50 through 11000 in the 17-230 $\mu$m domain as well as R~28.000 spectroscopy between 12 and 18 $\mu$m. Additionally SPICA will provide efficient 30-37 $\mu$m broad band mapping, and polarimetric imaging in the 100-350 $\mu$m range. SPICA will provide unprecedented spectroscopic sensitivity of ~5 x $10^{-20}$ W/m$^2$ (5$\sigma$/1hr) - at least two orders of magnitude improvement over what has been attained to date. With this exceptional leap in performance, new domains in infrared astronomy will become accessible, allowing us, for example, to unravel definitively galaxy evolution and metal production over cosmic time, to study dust formation and evolution from very early epochs onwards, and to trace the formation history of planetary systems.
[4]  oai:arXiv.org:1611.05268  [pdf] - 1515839
Optimising the multiplex factor of the frequency domain multiplexed readout of the TES-based microcalorimeter imaging array for the X-IFU instrument on the Athena Xray observatory
Comments:
Submitted: 2016-11-16
Athena is a space-based X-ray observatory intended for exploration of the hot and energetic universe. One of the science instruments on Athena will be the X-ray Integrated Field Unit (X-IFU), which is a cryogenic X-ray spectrometer, based on a large cryogenic imaging array of Transition Edge Sensors (TES) based microcalorimeters operating at a temperature of 100mK. The imaging array consists of 3800 pixels providing 2.5 eV spectral resolution, and covers a field of view with a diameter of of 5 arc minutes. Multiplexed readout of the cryogenic microcalorimeter array is essential to comply with the cooling power and complexity constraints on a space craft. Frequency domain multiplexing has been under development for the readout of TES-based detectors for this purpose, not only for the X-IFU detector arrays but also for TES-based bolometer arrays for the Safari instrument of the Japanese SPICA observatory. This paper discusses the design considerations which are applicable to optimise the multiplex factor within the boundary conditions as set by the space craft. More specifically, the interplay between the science requirements such as pixel dynamic range, pixel speed, and cross talk, and the space craft requirements such as the power dissipation budget, available bandwidth, and electromagnetic compatibility will be discussed.
[5]  oai:arXiv.org:1611.00956  [pdf] - 1521434
Development of frequency domain multiplexing for the X-ray Integral Field Unit (X-IFU) on the Athena
Comments: 8 pages, 4 figures, Proceedings of the SPIE Astronomical Instrumentation "Space Telescopes and Instrumentation 2014: Ultraviolet to Gamma Ray"
Submitted: 2016-11-03
We are developing the frequency domain multiplexing (FDM) read-out of transition-edge sensor (TES) microcalorimeters for the X-ray Integral Field Unit (X-IFU) instrument on board of the future European X-Ray observatory Athena. The X-IFU instrument consists of an array of $\sim$3840 TESs with a high quantum efficiency ($>$90 \%) and spectral resolution $\Delta E$=2.5 eV $@$ 7 keV ($E/\Delta E\sim$2800). FDM is currently the baseline readout system for the X-IFU instrument. Using high quality factor LC filters and room temperature electronics developed at SRON and low-noise two stage SQUID amplifiers provided by VTT, we have recently demonstrated good performance with the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. An integrated noise equivalent power resolution of about 2.0 eV at 1.7 MHz has been demonstrated with a pixel from a new TES array from NASA/Goddard (GSFC-A2). We have achieved X-ray energy resolutions $\sim$2.5 eV at AC bias frequency at 1.7 MHz in the single pixel read-out. We have also demonstrated for the first time an X-ray energy resolution around 3.0 eV in a 6 pixel FDM read-out with TES array (GSFC-A1). In this paper we report on the single pixel performance of these microcalorimeters under MHz AC bias, and further results of the performance of these pixels under FDM.
[6]  oai:arXiv.org:1607.00834  [pdf] - 1521238
Microcalorimeter pulse analysis by means of principle component decomposition
Comments: SPIE Astronomical Telescopes and Instrumentation; conference contribution
Submitted: 2016-07-04
The X-ray integral field unit for the Athena mission consists of a microcalorimeter transition edge sensor pixel array. Incoming photons generate pulses which are analyzed in terms of energy, in order to assemble the X-ray spectrum. Usually this is done by means of optimal filtering in either time or frequency domain. In this paper we investigate an alternative method by means of principle component analysis. This method attempts to find the main components of an orthogonal set of functions to describe the data. We show, based on simulations, what the influence of various instrumental effects is on this type of analysis. We compare analyses both in time and frequency domain. Finally we apply these analyses on real data, obtained via frequency domain multiplexing readout.
[7]  oai:arXiv.org:1604.02593  [pdf] - 1388308
AC bias characterization of low noise bolometers for SAFARI using an Open-Loop Frequency Domain SQUID-based multiplexer operating between 1 and 5 MHz
Comments: 6 pages, 5 figures
Submitted: 2016-04-09
SRON is developing the Frequency Domain Multiplexing (FDM) readout and the ultra low NEP TES bolometers array for the infrared spectrometer SAFARI on board of the Japanese space mission SPICA. The FDM prototype of the instrument requires critical and complex optimizations. For single pixel characterization under AC bias we are developing a simple FDM system working in the frequency range from 1 to 5 MHz, based on the open loop read-out of a linearized two-stage SQUID amplifier and high Q lithographic LC resonators. We describe the details of the experimental set-up required to achieve low power loading (< 1 fW) and low noise (NEP $\sim 10^{-19} W/Hz^{1/2}$) in the TES bolometers. We conclude the paper by comparing the performance of a $4 \cdot 10^{-19} W/Hz^{1/2}$ TES bolometer measured under DC and AC bias.
[8]  oai:arXiv.org:1604.02600  [pdf] - 1388309
A multiplexer for the ac/dc characterization of TES based bolometers and microcalorimeters
Comments: 7 pages, 6 figures, Proc. SPIE 8453, High Energy, Optical, and Infrared Detectors for Astronomy V, 845333 (25 September 2012). arXiv admin note: text overlap with arXiv:1604.02593
Submitted: 2016-04-09
At SRON we are developing the Frequency Domain Multiplexing (FDM) for the read-out of the TES-based detector array for the future infrared and X-ray space mission. We describe the performances of a multiplexer designed to increase the experimental throughput in the characterisation of ultra-low noise equivalent power (NEP) TES bolometers and high energy resolving power X-ray microcalorimeters arrays under ac and dc bias. We discuss the results obtained using the TiAu TES bolometers array fabricated at SRON with measured dark NEP below $5\cdot 10^{-19}W/Hz^{1/2}$ and saturation power of several fW
[9]  oai:arXiv.org:1604.00670  [pdf] - 1489757
Development of the superconducting detectors and read-out for the X-IFU instrument on board of the X-ray observatory Athena
Comments: 4 pages,4 figures, available on line (http://www.sciencedirect.com/science/article/pii/S0168900215011274)
Submitted: 2016-04-03
The Advanced Telescope for High-Energy Astrophysics (Athena) has been selected by ESA as its second large-class mission. The future European X-ray observatory will study the hot and energetic Universe with its launch foreseen in 2028. Microcalorimeters based on superconducting Transition-edge sensor (TES) are the chosen technology for the detectors array of the X-ray Integral Field Unit (X-IFU) on board of Athena. The X-IFU is a 2-D imaging integral-field spectrometer operating in the soft X-ray band (0.3 -12 keV). The detector consists of an array of 3840 TESs coupled to X-ray absorbers and read out in the MHz bandwidth using Frequency Domain Multiplexing (FDM) based on Superconducting QUantum Interference Devices (SQUIDs). The proposed design calls for devices with a high filling-factor, high quantum efficiency, relatively high count-rate capability and an energy resolution of 2.5 eV at 5.9 keV. The paper will review the basic principle and the physics of the TES-based microcalorimeters and present the state-of-the art of the FDM read-out.
[10]  oai:arXiv.org:1604.00680  [pdf] - 1384872
Weak-Link Phenomena in AC-Biased Transition Edge Sensors
Comments: 6 pages, 5 figure
Submitted: 2016-04-03
It has been recently demonstrated that superconducting transition edge sensors (TESs) behave as weak-links due to longitudinally induced superconductivity from the leads with higher Tc. In this work we study the implication of this behaviour for TES-based bolometers and microcalorimeter under ac bias. The TESs are read-out at frequencies between 1 and 5 MHz by a Frequency Domain Multiplexer based on a linearised two-stage SQUID amplifier and high- Q lithographically made superconducting LC resonators. In particular, we focus on SRON TiAu TES bolometers with a measured dark Noise Equivalent Power (NEP) of $3.2 \cdot 10^{-19} W/Hz^{1/2}$ developed for the short wavelength band for the instrument SAFARI on the SPICA telescope.
[11]  oai:arXiv.org:1604.00553  [pdf] - 1384861
Development of TES-based detectors array for the X-ray Integral Field Unit (X-IFU) on the future x-ray observatory ATHENA
Comments: 9 pages, 8 figures
Submitted: 2016-04-02
We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m squared, AuBi absorbers. We designed and fabricated devices with different contact geometries between the absorber and the TES to optimise the detector performance and with different wiring topology to mitigate the self-magnetic field. The design is tailored to optimise the performance under Frequency Domain Multiplexing. In this paper we review the main design feature of the pixels array and we report on the performance of the 18 channels, 2-5MHz frequency domain multiplexer that will be used to characterised the detector array.
[12]  oai:arXiv.org:1308.6784  [pdf] - 713384
The Hot and Energetic Universe: The X-ray Integral Field Unit (X-IFU) for Athena+
Comments: Supporting paper for the science theme "The Hot and Energetic Universe" to be implemented by the Athena+ X-ray observatory (http://www.the-athena-x-ray-observatory.eu). 17 pages, 19 figures
Submitted: 2013-08-30
The Athena+ mission concept is designed to implement the Hot and Energetic Universe science theme submitted to the European Space Agency in response to the call for White Papers for the definition of the L2 and L3 missions of its science program. The Athena+ science payload consists of a large aperture high angular resolution X-ray optics and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager (WFI). The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), offering 2.5 eV spectral resolution, with ~5" pixels, over a field of view of 5 arc minutes in diameter. In this paper, we briefly describe the Athena+ mission concept and the X-IFU performance requirements. We then present the X-IFU detector and readout electronics principles, the current design of the focal plane assembly, the cooling chain and review the global architecture design. Finally, we describe the current performance estimates, in terms of effective area, particle background rejection, count rate capability and velocity measurements. Finally, we emphasize on the latest technology developments concerning TES array fabrication, spectral resolution and readout performance achieved to show that significant progresses are being accomplished towards the demanding X-IFU requirements.