sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Vallee, P.

Normalized to: Vallee, P.

4 article(s) in total. 52 co-authors, from 1 to 4 common article(s). Median position in authors list is 8,0.

[1]  oai:arXiv.org:1812.09272  [pdf] - 1803021
Experimental test of a 40 cm-long R=100 000 spectrometer for exoplanet characterisation
Comments:
Submitted: 2018-12-21
High-resolution spectroscopy is a key element for present and future astronomical instrumentation. In particular, coupled to high contrast imagers and coronagraphs, high spectral resolution enables higher contrast and has been identified as a very powerful combination to characterise exoplanets, starting from giant planets now, up to Earth-like planet eventually for the future instruments. In this context, we propose the implementation of an innovative echelle spectrometer based on the use of VIPA (Virtually Imaged Phased Array, Shirasaki 1996). The VIPA itself is a particular kind of Fabry-Perot interferometer, used as an angular disperser with much greater dispersive power than common diffraction grating. The VIPA is an efficient, small component (3 cm x 2.4 cm), that takes the very advantage of single mode injection in a versatile design. The overall instrument presented here is a proof-of-concept of a compact, high-resolution (R > 80 000) spectrometer, dedicated to the H and K bands, in the context of the project High-Dispersion Coronagrahy developed at IPAG. The optical bench has a foot-print of 40 cm x 26 cm ; it is fed by two Single-Mode Fibers (SMF), one dedicated to the companion, and one to the star and/or to a calibration channel, and is cooled down to 80 K. This communication first presents the scientific and instrumental context of the project, and the principal merit of single-mode operations in high-resolution spectrometry. After recalling the physical structure of the VIPA and its implementation in an echelle-spectrometer design, it then details the optical design of the spectrometer. In conclusion, further steps (integration, calibration, coupling with adaptive optics) and possible optimization are briefly presented. Keywords: Echelle Spectrometer, High Spectral Resolution, Exoplanets, High-Dispersion Coronography, Infrared, Adaptive Optics, SPHERE
[2]  oai:arXiv.org:1407.2314  [pdf] - 1215533
The Integral Field Spectrograph for the Gemini Planet Imager
Comments: 13 pages, 10 figures. Proceedings of the SPIE, 9147-55
Submitted: 2014-07-08
The Gemini Planet Imager (GPI) is a complex optical system designed to directly detect the self-emission of young planets within two arcseconds of their host stars. After suppressing the starlight with an advanced AO system and apodized coronagraph, the dominant residual contamination in the focal plane are speckles from the atmosphere and optical surfaces. Since speckles are diffractive in nature their positions in the field are strongly wavelength dependent, while an actual companion planet will remain at fixed separation. By comparing multiple images at different wavelengths taken simultaneously, we can freeze the speckle pattern and extract the planet light adding an order of magnitude of contrast. To achieve a bandpass of 20%, sufficient to perform speckle suppression, and to observe the entire two arcsecond field of view at diffraction limited sampling, we designed and built an integral field spectrograph with extremely low wavefront error and almost no chromatic aberration. The spectrograph is fully cryogenic and operates in the wavelength range 1 to 2.4 microns with five selectable filters. A prism is used to produce a spectral resolution of 45 in the primary detection band and maintain high throughput. Based on the OSIRIS spectrograph at Keck, we selected to use a lenslet-based spectrograph to achieve an rms wavefront error of approximately 25 nm. Over 36,000 spectra are taken simultaneously and reassembled into image cubes that have roughly 192x192 spatial elements and contain between 11 and 20 spectral channels. The primary dispersion prism can be replaced with a Wollaston prism for dual polarization measurements. The spectrograph also has a pupil-viewing mode for alignment and calibration.
[3]  oai:arXiv.org:astro-ph/0504652  [pdf] - 72749
TRIDENT: an Infrared Differential Imaging Camera Optimized for the Detection of Methanated Substellar Companions
Comments: 41 pages, 16 figures, accepted for publication in PASP
Submitted: 2005-04-28
A near-infrared camera in use at the Canada-France-Hawaii Telescope (CFHT) and at the 1.6-m telescope of the Observatoire du Mont-Megantic is described. The camera is based on a Hawaii-1 1024x1024 HgCdTe array detector. Its main feature is to acquire three simultaneous images at three wavelengths across the methane absorption bandhead at 1.6 microns, enabling, in theory, an accurate subtraction of the stellar point spread function (PSF) and the detection of faint close methanated companions. The instrument has no coronagraph and features fast data acquisition, yielding high observing efficiency on bright stars. The performance of the instrument is described, and it is illustrated by laboratory tests and CFHT observations of the nearby stars GL526, Ups And and Chi And. TRIDENT can detect (6 sigma) a methanated companion with delta H = 9.5 at 0.5" separation from the star in one hour of observing time. Non-common path aberrations and amplitude modulation differences between the three optical paths are likely to be the limiting factors preventing further PSF attenuation. Instrument rotation and reference star subtraction improve the detection limit by a factor of 2 and 4 respectively. A PSF noise attenuation model is presented to estimate the non-common path wavefront difference effect on PSF subtraction performance.
[4]  oai:arXiv.org:astro-ph/0212033  [pdf] - 1233016
TRIDENT: an infrared camera optimized for the detection of methanated substellar companions around nearby stars
Comments: 8 pages, 6 figures, to appear in SPIE 4860
Submitted: 2002-12-02
A near-infrared (0.85-2.5 microns) camera in use at the Canada-France-Hawaii Telescope and at the 1.6m telescope of the Observatoire du Mont-Megantic is described. The camera is based on a Hawaii-1 1024x1024 HgCdTe array detector. Its main feature is to acquire three simultaneous images at three wavelengths (simultaneous differential imaging) across the methane absorption bandhead at 1.6 micron, enabling an accurate subtraction of the stellar point spread function (PSF) and the detection of faint close methanated companions. The instrument has no coronagraph and features a fast (1 MHz) data acquisition system without reset anomaly, yielding high observing efficiencies on bright stars. The performance of the instrument is described, and it is illustrated by CFHT images of the nearby star Ups And. TRIDENT can detect (3 sigma) a methanated companion with DeltaH=10 at 0.5 arcsec from the star in one hour of observing time. Non-common path aberrations between the three optical paths are the limiting factors preventing further PSF attenuation. Reference star subtraction and instrument rotation improve the detection limit by one order of magnitude.