Experimental test of a 40 cm-long R=100 000 spectrometer for exoplanet
characterisation
Bourdarot, Guillaume;
Coarer, Etienne Le;
Mouillet, David;
Correia, Jean-Jacques;
Jocou, Laurent;
Rabou, Patrick;
Carlotti, Alexis;
Bonfils, Xavier;
Artigau, Etienne;
Vallee, Philippe;
Doyon, Rene;
Forveille, Thierry;
Stadler, Eric;
Magnard, Yves;
Vigan, Arthur
Submitted: 2018-12-21
High-resolution spectroscopy is a key element for present and future
astronomical instrumentation. In particular, coupled to high contrast imagers
and coronagraphs, high spectral resolution enables higher contrast and has been
identified as a very powerful combination to characterise exoplanets, starting
from giant planets now, up to Earth-like planet eventually for the future
instruments. In this context, we propose the implementation of an innovative
echelle spectrometer based on the use of VIPA (Virtually Imaged Phased Array,
Shirasaki 1996). The VIPA itself is a particular kind of Fabry-Perot
interferometer, used as an angular disperser with much greater dispersive power
than common diffraction grating. The VIPA is an efficient, small component (3
cm x 2.4 cm), that takes the very advantage of single mode injection in a
versatile design. The overall instrument presented here is a proof-of-concept
of a compact, high-resolution (R > 80 000) spectrometer, dedicated to the H and
K bands, in the context of the project High-Dispersion Coronagrahy developed at
IPAG. The optical bench has a foot-print of 40 cm x 26 cm ; it is fed by two
Single-Mode Fibers (SMF), one dedicated to the companion, and one to the star
and/or to a calibration channel, and is cooled down to 80 K.
This communication first presents the scientific and instrumental context of
the project, and the principal merit of single-mode operations in
high-resolution spectrometry. After recalling the physical structure of the
VIPA and its implementation in an echelle-spectrometer design, it then details
the optical design of the spectrometer. In conclusion, further steps
(integration, calibration, coupling with adaptive optics) and possible
optimization are briefly presented.
Keywords: Echelle Spectrometer, High Spectral Resolution, Exoplanets,
High-Dispersion Coronography, Infrared, Adaptive Optics, SPHERE
[2]
oai:arXiv.org:1407.2314 [pdf] - 1215533
The Integral Field Spectrograph for the Gemini Planet Imager
Larkin, James E.;
Chilcote, Jeffrey K.;
Aliado, Theodore;
Bauman, Brian J.;
Brims, George;
Canfield, John M.;
Cardwell, Andrew;
Dillon, Daren;
Doyon, René;
Dunn, Jennifer;
Fitzgerald, Michael P.;
Graham, James R.;
Goodsell, Stephen;
Hartung, Markus;
Hibon, Pascale;
Ingraham, Patrick;
Johnson, Christopher A;
Kress, Evan;
Konopacky, Quinn M.;
Macintosh, Bruce A.;
Magnone, Kenneth G.;
Maire, Jérôme;
McLean, Ian S.;
Palmer, David;
Perrin, Marshall D.;
Quiroz, Carlos;
Rantakyrö, Fredrik;
Sadakuni, Naru;
Saddlemyer, Leslie;
Serio, Andrew;
Thibault, Simon;
Thomas, Sandrine J.;
Vallee, Philippe;
Weiss, Jason L.
Submitted: 2014-07-08
The Gemini Planet Imager (GPI) is a complex optical system designed to
directly detect the self-emission of young planets within two arcseconds of
their host stars. After suppressing the starlight with an advanced AO system
and apodized coronagraph, the dominant residual contamination in the focal
plane are speckles from the atmosphere and optical surfaces. Since speckles are
diffractive in nature their positions in the field are strongly wavelength
dependent, while an actual companion planet will remain at fixed separation. By
comparing multiple images at different wavelengths taken simultaneously, we can
freeze the speckle pattern and extract the planet light adding an order of
magnitude of contrast. To achieve a bandpass of 20%, sufficient to perform
speckle suppression, and to observe the entire two arcsecond field of view at
diffraction limited sampling, we designed and built an integral field
spectrograph with extremely low wavefront error and almost no chromatic
aberration. The spectrograph is fully cryogenic and operates in the wavelength
range 1 to 2.4 microns with five selectable filters. A prism is used to produce
a spectral resolution of 45 in the primary detection band and maintain high
throughput. Based on the OSIRIS spectrograph at Keck, we selected to use a
lenslet-based spectrograph to achieve an rms wavefront error of approximately
25 nm. Over 36,000 spectra are taken simultaneously and reassembled into image
cubes that have roughly 192x192 spatial elements and contain between 11 and 20
spectral channels. The primary dispersion prism can be replaced with a
Wollaston prism for dual polarization measurements. The spectrograph also has a
pupil-viewing mode for alignment and calibration.
[3]
oai:arXiv.org:astro-ph/0504652 [pdf] - 72749
TRIDENT: an Infrared Differential Imaging Camera Optimized for the
Detection of Methanated Substellar Companions
Submitted: 2005-04-28
A near-infrared camera in use at the Canada-France-Hawaii Telescope (CFHT)
and at the 1.6-m telescope of the Observatoire du Mont-Megantic is described.
The camera is based on a Hawaii-1 1024x1024 HgCdTe array detector. Its main
feature is to acquire three simultaneous images at three wavelengths across the
methane absorption bandhead at 1.6 microns, enabling, in theory, an accurate
subtraction of the stellar point spread function (PSF) and the detection of
faint close methanated companions. The instrument has no coronagraph and
features fast data acquisition, yielding high observing efficiency on bright
stars. The performance of the instrument is described, and it is illustrated by
laboratory tests and CFHT observations of the nearby stars GL526, Ups And and
Chi And. TRIDENT can detect (6 sigma) a methanated companion with delta H = 9.5
at 0.5" separation from the star in one hour of observing time. Non-common path
aberrations and amplitude modulation differences between the three optical
paths are likely to be the limiting factors preventing further PSF attenuation.
Instrument rotation and reference star subtraction improve the detection limit
by a factor of 2 and 4 respectively. A PSF noise attenuation model is presented
to estimate the non-common path wavefront difference effect on PSF subtraction
performance.
[4]
oai:arXiv.org:astro-ph/0212033 [pdf] - 1233016
TRIDENT: an infrared camera optimized for the detection of methanated
substellar companions around nearby stars
Submitted: 2002-12-02
A near-infrared (0.85-2.5 microns) camera in use at the Canada-France-Hawaii
Telescope and at the 1.6m telescope of the Observatoire du Mont-Megantic is
described. The camera is based on a Hawaii-1 1024x1024 HgCdTe array detector.
Its main feature is to acquire three simultaneous images at three wavelengths
(simultaneous differential imaging) across the methane absorption bandhead at
1.6 micron, enabling an accurate subtraction of the stellar point spread
function (PSF) and the detection of faint close methanated companions. The
instrument has no coronagraph and features a fast (1 MHz) data acquisition
system without reset anomaly, yielding high observing efficiencies on bright
stars. The performance of the instrument is described, and it is illustrated by
CFHT images of the nearby star Ups And. TRIDENT can detect (3 sigma) a
methanated companion with DeltaH=10 at 0.5 arcsec from the star in one hour of
observing time. Non-common path aberrations between the three optical paths are
the limiting factors preventing further PSF attenuation. Reference star
subtraction and instrument rotation improve the detection limit by one order of
magnitude.