Normalized to: Vale, L.
[1]
oai:arXiv.org:1909.01305 [pdf] - 2034407
Microwave multiplexing on the Keck Array
Cukierman, Ari;
Ahmed, Zeeshan;
Henderson, Shawn;
Young, Edward;
Yu, Cyndia;
Barkats, Denis;
Brown, David;
Chaudhuri, Saptarshi;
Cornelison, James;
D'Ewart, John M.;
Dierickx, Marion;
Dober, Bradley J.;
Dusatko, John;
Fatigoni, Sofia;
Filippini, Jeff P.;
Frisch, Josef C.;
Haller, Gunther;
Halpern, Mark;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Karkare, Kirit S.;
Karpel, Ethan;
Kernasovskiy, Sarah A.;
Kovac, John M.;
Kovacs, Attila;
Kuenstner, Stephen E.;
Kuo, Chao-Lin;
Li, Dale;
Mates, John A. B.;
Smith, Stephen;
Germaine, Tyler St.;
Ullom, Joel N.;
Vale, Leila R.;
Van Winkle, Daniel D.;
Vasquez, Jesus;
Willmert, Justin;
Zeng, Lingzhen;
Ade, P. A. R.;
Amiri, M.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Crumrine, M.;
Duband, L.;
Hall, G.;
Harrison, S.;
Hildebrandt, S. R.;
Hui, H.;
Kang, J.;
Kefeli, S.;
Lau, K.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Nguyen, H. T.;
O'Brient, R.;
Palladino, S.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schillaci, A.;
Schwarz, R.;
Sheehy, C. D.;
Soliman, A.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tucker, C.;
Turner, A. D.;
Umilta, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Wu, W. L. K.;
Yang, H.;
Yoon, K. W.;
Zhang, C.
Submitted: 2019-09-03, last modified: 2020-01-17
We describe an on-sky demonstration of a microwave-multiplexing readout
system in one of the receivers of the Keck Array, a polarimetry experiment
observing the cosmic microwave background at the South Pole. During the austral
summer of 2018-2019, we replaced the time-division multiplexing readout system
with microwave-multiplexing components including superconducting microwave
resonators coupled to radio-frequency superconducting quantum interference
devices at the sub-Kelvin focal plane, coaxial-cable plumbing and amplification
between room temperature and the cold stages, and a SLAC Microresonator Radio
Frequency system for the warm electronics. In the range 5-6 GHz, a single
coaxial cable reads out 528 channels. The readout system is coupled to
transition-edge sensors, which are in turn coupled to 150-GHz slot-dipole
phased-array antennas. Observations began in April 2019, and we report here on
an initial characterization of the system performance.
[2]
oai:arXiv.org:1907.11976 [pdf] - 2025648
Performance of Al-Mn Transition-Edge Sensor Bolometers in SPT-3G
Anderson, A. J.;
Ade, P. A. R.;
Ahmed, Z.;
Avva, J. S.;
Barry, P. S.;
Thakur, R. Basu;
Bender, A. N.;
Benson, B. A.;
Bryant, L.;
Byrum, K.;
Carlstrom, J. E.;
Carter, F. W.;
Cecil, T. W.;
Chang, C. L.;
Cho, H. -M.;
Cliche, J. F.;
Cukierman, A.;
de Haan, T.;
Denison, E. V.;
Ding, J.;
Dobbs, M. A.;
Dutcher, D.;
Everett, W.;
Ferguson, K. R.;
Foster, A.;
Fu, J.;
Gallicchio, J.;
Gambrel, A. E.;
Gardner, R. W.;
Gilbert, A.;
Groh, J. C.;
Guns, S.;
Guyser, R.;
Halverson, N. W.;
Harke-Hosemann, A. H.;
Harrington, N. L.;
Henning, J. W.;
Hilton, G. C.;
Holzapfel, W. L.;
Howe, D.;
Huang, N.;
Irwin, K. D.;
Jeong, O. B.;
Jonas, M.;
Jones, A.;
Khaire, T. S.;
Kofman, A. M.;
Korman, M.;
Kubik, D. L.;
Kuhlmann, S.;
Kuo, C. -L.;
Lee, A. T.;
Leitch, E. M.;
Lowitz, A. E.;
Meyer, S. S.;
Michalik, D.;
Montgomery, J.;
Nadolski, A.;
Natoli, T.;
Nguyen, H.;
Noble, G. I.;
Novosad, V.;
Padin, S.;
Pan, Z.;
Paschos, P.;
Pearson, J.;
Posada, C. M.;
Quan, W.;
Rahlin, A.;
Riebel, D.;
Ruhl, J. E.;
Sayre, J. T.;
Shirokoff, E.;
Smecher, G.;
Sobrin, J. A.;
Stark, A. A.;
Stephen, J.;
Story, K. T.;
Suzuki, A.;
Thompson, K. L.;
Tucker, C.;
Vale, L. R.;
Vanderlinde, K.;
Vieira, J. D.;
Wang, G.;
Whitehorn, N.;
Yefremenko, V.;
Yoon, K. W.;
Young, M. R.
Submitted: 2019-07-27
SPT-3G is a polarization-sensitive receiver, installed on the South Pole
Telescope, that measures the anisotropy of the cosmic microwave background
(CMB) from degree to arcminute scales. The receiver consists of ten
150~mm-diameter detector wafers, containing a total of 16,000 transition-edge
sensor (TES) bolometers observing at 95, 150, and 220 GHz. During the 2018-2019
austral summer, one of these detector wafers was replaced by a new wafer
fabricated with Al-Mn TESs instead of the Ti/Au design originally deployed for
SPT-3G. We present the results of in-lab characterization and on-sky
performance of this Al-Mn wafer, including electrical and thermal properties,
optical efficiency measurements, and noise-equivalent temperature. In addition,
we discuss and account for several calibration-related systematic errors that
affect measurements made using frequency-domain multiplexing readout
electronics.
[3]
oai:arXiv.org:1907.10947 [pdf] - 2025643
On-sky performance of the SPT-3G frequency-domain multiplexed readout
Bender, A. N.;
Anderson, A. J.;
Avva, J. S.;
Ade, P. A. R.;
Ahmed, Z.;
Barry, P. S.;
Thakur, R. Basu;
Benson, B. A.;
Bryant, L.;
Byrum, K.;
Carlstrom, J. E.;
Carter, F. W.;
Cecil, T. W.;
Chang, C. L.;
Cho, H. -M.;
Cliche, J. F.;
Cukierman, A.;
de Haan, T.;
Denison, E. V.;
Ding, J.;
Dobbs, M. A.;
Dutcher, D.;
Everett, W.;
Ferguson, K. R.;
Foster, A.;
Fu, J.;
Gallicchio, J.;
Gambrel, A. E.;
Gardner, R. W.;
Gilbert, A.;
Groh, J. C.;
Guns, S.;
Guyser, R.;
Halverson, N. W.;
Harke-Hosemann, A. H.;
Harrington, N. L.;
Henning, J. W.;
Hilton, G. C.;
Holzapfel, W. L.;
Howe, D.;
Huang, N.;
Irwin, K. D.;
Jeong, O. B.;
Jonas, M.;
Jones, A.;
Khaire, T. S.;
Kofman, A. M.;
Korman, M.;
Kubik, D. L.;
Kuhlmann, S.;
Kuo, C. -L.;
Lee, A. T.;
Leitch, E. M.;
Lowitz, A. E.;
Meyer, S. S.;
Michalik, D.;
Montgomery, J.;
Nadolski, A.;
Natoli, T.;
Nguyen, H.;
Noble, G. I.;
Novosad, V.;
Padin, S.;
Pan, Z.;
Paschos, P.;
Pearson, J.;
Posada, C. M.;
Quan, W.;
Rahlin, A.;
Riebel, D.;
Ruhl, J. E.;
Sayre, J. T.;
Shirokoff, E.;
Smecher, G.;
Sobrin, J. A.;
Stark, A. A.;
Stephen, J.;
Story, K. T.;
Suzuki, A.;
Thompson, K. L.;
Tucker, C.;
Vale, L. R.;
Vanderlinde, K.;
Vieira, J. D.;
Wang, G.;
Whitehorn, N.;
Yefremenko, V.;
Yoon, K. W.;
Young, M. R.
Submitted: 2019-07-25
Frequency-domain multiplexing (fMux) is an established technique for the
readout of large arrays of transition edge sensor (TES) bolometers. Each TES in
a multiplexing module has a unique AC voltage bias that is selected by a
resonant filter. This scheme enables the operation and readout of multiple
bolometers on a single pair of wires, reducing thermal loading onto sub-Kelvin
stages. The current receiver on the South Pole Telescope, SPT-3G, uses a 68x
fMux system to operate its large-format camera of $\sim$16,000 TES bolometers.
We present here the successful implementation and performance of the SPT-3G
readout as measured on-sky. Characterization of the noise reveals a median
pair-differenced 1/f knee frequency of 33 mHz, indicating that low-frequency
noise in the readout will not limit SPT-3G's measurements of sky power on large
angular scales. Measurements also show that the median readout white noise
level in each of the SPT-3G observing bands is below the expectation for photon
noise, demonstrating that SPT-3G is operating in the photon-noise-dominated
regime.
[4]
oai:arXiv.org:1902.09640 [pdf] - 1838469
Design and Bolometer Characterization of the SPT-3G First-year Focal
Plane
Everett, W.;
Ade, P. A. R.;
Ahmed, Z.;
Anderson, A. J.;
Austermann, J. E.;
Avva, J. S.;
Thakur, R. Basu;
Bender, A. N.;
Benson, B. A.;
Carlstrom, J. E.;
Carter, F. W.;
Cecil, T.;
Chang, C. L.;
Cliche, J. F.;
Cukierman, A.;
Denison, E. V.;
de Haan, T.;
Ding, J.;
Dobbs, M. A.;
Dutcher, D.;
Foster, A.;
Gannon, R. N.;
Gilbert, A.;
Groh, J. C.;
Halverson, N. W.;
Harke-Hosemann, A. H.;
Harrington, N. L.;
Henning, J. W.;
Hilton, G. C.;
Holzapfel, W. L.;
Huang, N.;
Irwin, K. D.;
Jeong, O. B.;
Jonas, M.;
Khaire, T.;
Kofman, A. M.;
Korman, M.;
Kubik, D.;
Kuhlmann, S.;
Kuo, C. L.;
Lee, A. T.;
Lowitz, A. E.;
Meyer, S. S.;
Michalik, D.;
Montgomery, J.;
Nadolski, A.;
Natoli, T.;
Nguyen, H.;
Noble, G. I.;
Novosad, V.;
Padin, S.;
Pan, Z.;
Pearson, J.;
Posada, C. M.;
Rahlin, A.;
Ruhl, J. E.;
Saunders, L. J.;
Sayre, J. T.;
Shirley, I.;
Shirokoff, E.;
Smecher, G.;
Sobrin, J. A.;
Stark, A. A.;
Story, K. T.;
Suzuki, A.;
Tang, Q. Y.;
Thompson, K. L.;
Tucker, C.;
Vale, L. R.;
Vanderlinde, K.;
Vieira, J. D.;
Wang, G.;
Whitehorn, N.;
Yefremenko, V.;
Yoon, K. W.;
Young, M. R.
Submitted: 2019-02-25
During the austral summer of 2016-17, the third-generation camera, SPT-3G,
was installed on the South Pole Telescope, increasing the detector count in the
focal plane by an order of magnitude relative to the previous generation.
Designed to map the polarization of the cosmic microwave background, SPT-3G
contains ten 6-in-hexagonal modules of detectors, each with 269 trichroic and
dual-polarization pixels, read out using 68x frequency-domain multiplexing.
Here we discuss design, assembly, and layout of the modules, as well as early
performance characterization of the first-year array, including yield and
detector properties.
[5]
oai:arXiv.org:1809.03689 [pdf] - 1748092
Highly-multiplexed microwave SQUID readout using the SLAC Microresonator
Radio Frequency (SMuRF) Electronics for Future CMB and Sub-millimeter Surveys
Henderson, Shawn W.;
Ahmed, Zeeshan;
Austermann, Jason;
Becker, Daniel;
Bennett, Douglas A.;
Brown, David;
Chaudhuri, Saptarshi;
Cho, Hsiao-Mei Sherry;
D'Ewart, John M.;
Dober, Bradley;
Duff, Shannon M.;
Dusatko, John E.;
Fatigoni, Sofia;
Frisch, Josef C.;
Gard, Jonathon D.;
Halpern, Mark;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Karpel, Ethan D.;
Kernasovskiy, Sarah S.;
Kuenstner, Stephen E.;
Kuo, Chao-Lin;
Li, Dale;
Mates, John A. B.;
Reintsema, Carl D.;
Smith, Stephen R.;
Ullom, Joel;
Vale, Leila R.;
Van Winkle, Daniel D.;
Vissers, Michael;
Yu, Cyndia
Submitted: 2018-09-11
The next generation of cryogenic CMB and submillimeter cameras under
development require densely instrumented sensor arrays to meet their science
goals. The readout of large numbers ($\sim$10,000--100,000 per camera) of
sub-Kelvin sensors, for instance as proposed for the CMB-S4 experiment, will
require substantial improvements in cold and warm readout techniques. To reduce
the readout cost per sensor and integration complexity, efforts are presently
focused on achieving higher multiplexing density while maintaining readout
noise subdominant to intrinsic detector noise. Highly-multiplexed cold readout
technologies in active development include Microwave Kinetic Inductance Sensors
(MKIDs) and microwave rf-SQUIDs. Both exploit the high quality factors of
superconducting microwave resonators to densely channelize sub-Kelvin sensors
into the bandwidth of a microwave transmission line. We present advancements in
the development of a new warm readout system for microwave SQUID multiplexing,
the SLAC Superconducting Microresonator RF electronics, or SMuRF. The SMuRF
system is unique in its ability to track each tone, minimizing the total RF
power required to read out each resonator, thereby significantly reducing the
linearity requirements on the cold and warm readout. Here, we present
measurements of the readout noise and linearity of the first full SMuRF system,
including a demonstration of closed-loop tone tracking on a 528 channel
cryogenic microwave SQUID multiplexer. SMuRF is being explored as a potential
readout solution for several future CMB projects including Simons Observatory,
BICEP Array, CCAT-prime, Ali-CPT, and CMB-S4. Parallel development of the
platform is underway to adapt SMuRF to read out both MKID and fast X-ray TES
calorimeter arrays.
[6]
oai:arXiv.org:1809.00036 [pdf] - 1743942
Year two instrument status of the SPT-3G cosmic microwave background
receiver
Bender, A. N.;
Ade, P. A. R.;
Ahmed, Z.;
Anderson, A. J.;
Avva, J. S.;
Aylor, K.;
Barry, P. S.;
Thakur, R. Basu;
Benson, B. A.;
Bleem, L. S.;
Bocquet, S.;
Byrum, K.;
Carlstrom, J. E.;
Carter, F. W.;
Cecil, T. W.;
Chang, C. L.;
Cho, H. -M.;
Cliche, J. F.;
Crawford, T. M.;
Cukierman, A.;
de Haan, T.;
Denison, E. V.;
Ding, J.;
Dobbs, M. A.;
Dodelson, S.;
Dutcher, D.;
Everett, W.;
Foster, A.;
Gallicchio, J.;
Gilbert, A.;
Groh, J. C.;
Guns, S. T.;
Halverson, N. W.;
Harke-Hosemann, A. H.;
Harrington, N. L.;
Henning, J. W.;
Hilton, G. C.;
Holder, G. P.;
Holzapfel, W. L.;
Huang, N.;
Irwin, K. D.;
Jeong, O. B.;
Jonas, M.;
Jones, A.;
Khaire, T. S.;
Knox, L.;
Kofman, A. M.;
Korman, M.;
Kubik, D. L.;
Kuhlmann, S.;
Kuo, C. -L.;
Lee, A. T.;
Leitch, E. M.;
Lowitz, A. E.;
Meyer, S. S.;
Michalik, D.;
Montgomery, J.;
Nadolski, A.;
Natoli, T.;
Nguyen, H.;
Noble, G. I.;
Novosad, V.;
Padin, S.;
Pan, Z.;
Pearson, J.;
Posada, C. M.;
Quan, W.;
Raghunathan, S.;
Rahlin, A.;
Reichardt, C. L.;
Ruhl, J. E.;
Sayre, J. T.;
Shirokoff, E.;
Smecher, G.;
Sobrin, J. A.;
Stark, A. A.;
Story, K. T.;
Suzuki, A.;
Thompson, K. L.;
Tucker, C.;
Vale, L. R.;
Vanderlinde, K.;
Vieira, J. D.;
Wang, G.;
Whitehorn, N.;
Wu, W. L. K.;
Yefremenko, V.;
Yoon, K. W.;
Young, M. R.
Submitted: 2018-08-31
The South Pole Telescope (SPT) is a millimeter-wavelength telescope designed
for high-precision measurements of the cosmic microwave background (CMB). The
SPT measures both the temperature and polarization of the CMB with a large
aperture, resulting in high resolution maps sensitive to signals across a wide
range of angular scales on the sky. With these data, the SPT has the potential
to make a broad range of cosmological measurements. These include constraining
the effect of massive neutrinos on large-scale structure formation as well as
cleaning galactic and cosmological foregrounds from CMB polarization data in
future searches for inflationary gravitational waves. The SPT began observing
in January 2017 with a new receiver (SPT-3G) containing $\sim$16,000
polarization-sensitive transition-edge sensor bolometers. Several key
technology developments have enabled this large-format focal plane, including
advances in detectors, readout electronics, and large millimeter-wavelength
optics. We discuss the implementation of these technologies in the SPT-3G
receiver as well as the challenges they presented. In late 2017 the
implementations of all three of these technologies were modified to optimize
total performance. Here, we present the current instrument status of the SPT-3G
receiver.
[7]
oai:arXiv.org:1805.08363 [pdf] - 1709494
SLAC Microresonator Radio Frequency (SMuRF) Electronics for Read Out of
Frequency-Division-Multiplexed Cryogenic Sensors
Kernasovskiy, S. A.;
Kuenstner, S. E.;
Karpel, E.;
Ahmed, Z.;
Van Winkle, D. D.;
Smith, S.;
Dusatko, J.;
Frisch, J. C.;
Chaudhuri, S.;
Cho, H. M.;
Dober, B. J.;
Henderson, S. W.;
Hilton, G. C.;
Hubmayr, J.;
Irwin, K. D.;
Kuo, C. L.;
Li, D.;
Mates, J. A. B.;
Nasr, M.;
Tantawi, S.;
Ullom, J.;
Vale, L.;
Young, B.
Submitted: 2018-05-21
Large arrays of cryogenic sensors for various imaging applications ranging
across x-ray, gamma-ray, Cosmic Microwave Background (CMB), mm/sub-mm, as well
as particle detection increasingly rely on superconducting microresonators for
high multiplexing factors. These microresonators take the form of microwave
SQUIDs that couple to Transition-Edge Sensors (TES) or Microwave Kinetic
Inductance Detectors (MKIDs). In principle, such arrays can be read out with
vastly scalable software-defined radio using suitable FPGAs, ADCs and DACs. In
this work, we share plans and show initial results for SLAC Microresonator
Radio Frequency (SMuRF) electronics, a next-generation control and readout
system for superconducting microresonators. SMuRF electronics are unique in
their implementation of specialized algorithms for closed-loop tone tracking,
which consists of fast feedback and feedforward to each resonator's excitation
parameters based on transmission measurements. Closed-loop tone tracking
enables improved system linearity, a significant increase in sensor count per
readout line, and the possibility of overcoupled resonator designs for enhanced
dynamic range. Low-bandwidth prototype electronics were used to demonstrate
closed-loop tone tracking on twelve 300-kHz-wide microwave SQUID resonators,
spaced at $\sim$6 MHz with center frequencies $\sim$5-6 GHz. We achieve
multi-kHz tracking bandwidth and demonstrate that the noise floor of the
electronics is subdominant to the noise intrinsic in the multiplexer.
[8]
oai:arXiv.org:1805.03219 [pdf] - 1679898
Optical Characterization of the SPT-3G Focal Plane
Pan, Zhaodi;
Ade, Peter;
Ahmed, Zeeshan;
Adam, Anderson;
Austermann, Jason;
Avva, Jessica;
Thakur, Ritoban Basu;
Amy, Bender;
Benson, Bradford;
Carlstrom, John;
Carter, Faustin;
Cecil, Thomas;
Chang, Clarence;
Cliche, Jean-Francois;
Cukierman, Ariel;
Denison, Edward;
de Haan, Tijmen;
Ding, Junjia;
Dobbs, Matt;
Dutcher, Daniel;
Everett, Wendeline;
Foster, Allen;
Gannon, Renae;
Gilbert, Adam;
Groh, John;
Halverson, Nils;
Harke-Horsemann, Angelina;
Harrington, Nicholas;
Henning, Jaosn;
Hilton, Gene;
Holzapfel, William;
Huang, Nicholas;
Irwin, Kent;
Jeong, Oliver;
Jonas, Michalle;
Khaire, Trupti;
Kofman, Anna;
Korman, Milo;
Kubik, Donna;
Kuhlmann, Steve;
Kuo, Chaolin;
Lee, Adrian;
Lowitz, Amy;
Meyer, Stephan;
Michalik, Daniel;
Montgomery, Joshua;
Nadolski, Andrew;
Natoli, Tyler;
Nguyen, Hogan;
Noble, Gavin;
Novosad, Valentyn;
Padin, Stephan;
Pearson, John;
Posada, Chrystian;
Rahlin, Alexandra;
Ruhl, John;
Saunders, Lauren;
Sayre, James;
Shirley, Ian;
Shirokoff, Erik;
Smecher, Graeme;
Sobrin, Joshua;
Stark, Antony;
Story, Kyle;
Suzuki, Aritoki;
Tang, Qingyang;
Thompson, Keith;
Tucker, Carole;
Vale, Leila;
Vanderlinde, Keith;
Vieira, Joaquin;
Wang, Gensheng;
Whitehorn, Nathan;
Yefremenko, Volodymyr;
Yoon, Ki Won;
Young, Matt
Submitted: 2018-05-08
The third-generation South Pole Telescope camera is designed to measure the
cosmic microwave background across three frequency bands (95, 150 and 220 GHz)
with ~16,000 transition-edge sensor (TES) bolometers. Each multichroic pixel on
a detector wafer has a broadband sinuous antenna that couples power to six
TESs, one for each of the three observing bands and both polarization
directions, via lumped element filters. Ten detector wafers populate the focal
plane, which is coupled to the sky via a large-aperture optical system. Here we
present the frequency band characterization with Fourier transform
spectroscopy, measurements of optical time constants, beam properties, and
optical and polarization efficiencies of the focal plane. The detectors have
frequency bands consistent with our simulations, and have high average optical
efficiency which is 86%, 77% and 66% for the 95, 150 and 220 GHz detectors. The
time constants of the detectors are mostly between 0.5 ms and 5 ms. The beam is
round with the correct size, and the polarization efficiency is more than 90%
for most of the bolometers
[9]
oai:arXiv.org:1710.04326 [pdf] - 1604980
Microwave SQUID Multiplexer demonstration for Cosmic Microwave
Background Imagers
Dober, B.;
Becker, D. T.;
Bennett, D. A.;
Bryan, S. A.;
Duff, S. M.;
Gard, J. D.;
Hays-Wehle, J. P.;
Hilton, G. C.;
Hubmayr, J.;
Mates, J. A. B.;
Reintsema, C. D.;
Vale, L. R.;
Ullom, J. N.
Submitted: 2017-10-11, last modified: 2017-12-15
Key performance characteristics are demonstrated for the microwave SQUID
multiplexer ($\mu$MUX) coupled to transition edge sensor (TES) bolometers that
have been optimized for cosmic microwave background (CMB) observations. In a
64-channel demonstration, we show that the $\mu$MUX produces a white, input
referred current noise level of 29~pA$/\sqrt{\mathrm{Hz}}$ at -77~dB microwave
probe tone power, which is well below expected fundamental detector and photon
noise sources for a ground-based CMB-optimized bolometer. Operated with
negligible photon loading, we measure 98~pA$/\sqrt{\mathrm{Hz}}$ in the
TES-coupled channels biased at 65% of the sensor normal resistance. This noise
level is consistent with that predicted from bolometer thermal fluctuation
(i.e., phonon) noise. Furthermore, the power spectral density exhibits a white
spectrum at low frequencies ($\sim$~100~mHz), which enables CMB mapping on
large angular scales that constrain the physics of inflation. Additionally, we
report cross-talk measurements that indicate a level below 0.3%, which is less
than the level of cross-talk from multiplexed readout systems in deployed CMB
imagers. These measurements demonstrate the $\mu$MUX as a viable readout
technique for future CMB imaging instruments.
[10]
oai:arXiv.org:1310.7287 [pdf] - 1180273
High-resolution gamma-ray spectroscopy with a microwave-multiplexed
transition-edge sensor array
Noroozian, Omid;
Mates, John A. B.;
Bennett, Douglas A.;
Brevik, Justus A.;
Fowler, Joseph W.;
Gao, Jiansong;
Hilton, Gene C.;
Horansky, Robert D.;
Irwin, Kent D.;
Kang, Zhao;
Schmidt, Daniel R.;
Vale, Leila R.;
Ullom, Joel N.
Submitted: 2013-10-27
We demonstrate very high resolution photon spectroscopy with a
microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured
a $^{153}$Gd photon source and achieved an energy resolution of 63 eV
full-width-at-half-maximum at 97 keV and an equivalent readout system noise of
86 pA/$\sqrt{\text{Hz}}$ at the TES. The readout circuit consists of
superconducting microwave resonators coupled to radio-frequency
superconducting-quantum-interference-devices (SQUID) and transduces changes in
input current to changes in phase of a microwave signal. We use flux-ramp
modulation to linearize the response and evade low-frequency noise. This
demonstration establishes one path for the readout of cryogenic X-ray and
gamma-ray sensor arrays with more than $10^3$ elements and spectral resolving
powers $R=\lambda/\Delta\lambda > 10^3$.
[11]
oai:arXiv.org:1110.1608 [pdf] - 506520
Advanced code-division multiplexers for superconducting detector arrays
Irwin, K. D.;
Cho, H. M.;
Doriese, W. B.;
Fowler, J. W.;
Hilton, G. C.;
Niemack, M. D.;
Reintsema, C. D.;
Schmidt, D. R.;
Ullom, J. N.;
Vale, L. R.
Submitted: 2011-10-07
Multiplexers based on the modulation of superconducting quantum interference
devices are now regularly used in multi-kilopixel arrays of superconducting
detectors for astrophysics, cosmology, and materials analysis. Over the next
decade, much larger arrays will be needed. These larger arrays require new
modulation techniques and compact multiplexer elements that fit within each
pixel. We present a new in-focal-plane code-division multiplexer that provides
multiplexing elements with the required scalability. This code-division
multiplexer uses compact lithographic modulation elements that simultaneously
multiplex both signal outputs and superconducting transition-edge sensor (TES)
detector bias voltages. It eliminates the shunt resistor used to voltage bias
TES detectors, greatly reduces power dissipation, allows different dc bias
voltages for each TES, and makes all elements sufficiently compact to fit
inside the detector pixel area. These in-focal-plane code-division multiplexers
can be combined with multi-gigahertz readout based on superconducting
microresonators to scale to even larger arrays.