Normalized to: Ulrich, A.
[1]
oai:arXiv.org:1905.03044 [pdf] - 1938412
Photoluminescence response of acrylic (PMMA) and polytetrafluoroethylene
(PTFE) to ultraviolet light
Submitted: 2019-05-08, last modified: 2019-05-20
Some publications indicate that poly(methyl methacrylate) (PMMA) and
polytetrafluoroethylene (PTFE) exhibit low levels of photoluminesence
(fluorescence and/or phosphorescence) when irradiated with photons in the
ultraviolet (UV) to visible range. PMMA (also known as acrylic) and PTFE are
commonly used to contain the liquid argon (LAr) or xenon (LXe) target material
in rare-event search experiments. LAr and LXe scintillate in the vacuum UV
region, and the PMMA and PTFE can be directly illuminated by these photons.
Photoluminescence from support materials could cause unexpected signals in
these detectors.
We investigate photoluminesence in the 400 nm to 550 nm region in response to
excitation with UV light between 130 nm and 250 nm at levels relevant to
rare-event search experiments. Measurements are done at room temperature and
the signal intensity is time-integrated over several minutes.
We tested PMMA and PTFE samples from the batches used in the DEAP-3600 and
LUX experiments and observed no photoluminescence signal. We put limits on the
efficiency of the plastics to shift UV photons to a wavelengths region of 400
nm to 550 nm at 0.05% to 0.35% relative to the wavelength shifting efficiency
of tetraphenyl-butadiene.
[2]
oai:arXiv.org:1802.08639 [pdf] - 1639827
A prototype detector for the CRESST-III low-mass dark matter search
Strauss, R.;
Angloher, G.;
Bauer, P.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Hampf, R.;
Hauff, D.;
Kiefer, M.;
Lanfranchi, J. -C.;
Langenkämper, A.;
Mondragon, E.;
Münster, A.;
Oppenheimer, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schönert, S.;
Seidel, W.;
Steiger, H.;
Stodolsky, L.;
Tanzke, A.;
Thi, H. H. Trinh;
Ulrich, A.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2018-02-23
The CRESST-III experiment which is dedicated to low-mass dark matter search
uses scintillating CaWO$_4$ crystals operated as cryogenic particle detectors.
Background discrimination is achieved by exploiting the scintillating light
signal of CaWO$_4$ and by a novel active detector holder presented in this
paper. In a test setup above ground, a nuclear-recoil energy threshold of
$E_{th}=(190.6\pm5.2)$eV is reached with a 24g prototype detector, which
corresponds to an estimated threshold of $\sim$50eV when being operated in the
low-noise CRESST cryostat. This is the lowest threshold reported for direct
dark matter searches. For CRESST-III phase 1, ten such detector modules were
installed in the cryostat which have the potential to improve significantly the
sensitivity to scatterings of dark matter particles with masses down to
$\sim$0.1GeV/c$^2$.
[3]
oai:arXiv.org:1703.07152 [pdf] - 1648551
Low-Temperature Relative Reflectivity Measurements of Reflective and
Scintillating Foils used in Rare Event Searches
Langenkämper, A.;
Ulrich, A.;
Defay, X.;
Feilitzsch, F. v.;
Lanfranchi, J. -C.;
Mondragón, E.;
Münster, A.;
Oppenheimer, C.;
Potzel, W.;
Roth, S.;
Schönert, S.;
Steiger, H.;
Thi, H. H. Trinh;
Wawoczny, S.;
Willers, M.;
Zöller, A.
Submitted: 2017-03-21, last modified: 2017-12-20
In this work we investigate the reflectivity of highly reflective multilayer
polymer foils used in the CRESST experiment. The CRESST experiment searches
directly for dark matter via operating scintillating CaWO$_4$ crystals as
targets for elastic dark matter-nucleon scattering. In order to suppress
background events, the experiment employs the so-called phonon-light technique
which is based on the simultaneous measurement of the heat signal in the main
CaWO$_4$ target crystal and of the emitted scintillation light with a separate
cryogenic light detector. Both detectors are surrounded by a highly reflective
and scintillating multilayer polymer foil to increase the light collection
efficiency and to veto surface backgrounds. While this study is motivated by
the CRESST experiment, the results are also relevant for other rare event
searches using scintillating cryogenic bolometers in the field of the search of
dark matter and neutrinoless double beta decay ($0\nu\beta\beta$). In this work
a dedicated experiment has been set up to determine the relative reflectivity
at 300 K and 20 K of three multilayer foils ("VM2000", "VM2002", "Vikuiti")
produced by the company 3M. The intensity of a light beam reflected off the
foil is measured with a CCD camera. The ratio of the intensities at 300 K and
20 K corresponds to the relative reflectivity change. The measurements
performed in this work show no significant change in the reflectivity with
temperature for all foils studied.
[4]
oai:arXiv.org:1711.07692 [pdf] - 1591519
First results on low-mass dark matter from the CRESST-III experiment
CRESST collaboration;
Petricca, F.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Lagenkämper, A.;
Loebell, J.;
Mancuso, M.;
Mondragon, E.;
Münster, A.;
Pagliarone, C.;
Potzel, W.;
Pröbst, F.;
Puig, R.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.
Submitted: 2017-11-21
The CRESST experiment, located at Laboratori Nazionali del Gran Sasso in
Italy, searches for dark matter particles via their elastic scattering off
nuclei in a target material. The CRESST target consists of scintillating
CaWO$_4$ crystals, which are operated as cryogenic calorimeters at millikelvin
temperatures. Each interaction in the CaWO$_4$ target crystal produces a phonon
signal and a light signal that is measured by a second cryogenic calorimeter.
Since the CRESST-II result in 2015, the experiment is leading the field of
direct dark matter search for dark matter masses below 1.7\,GeV/$c^2$,
extending the reach of direct searches to the sub-GeV/$c^2$ mass region. For
CRESST-III, whose Phase 1 started in July 2016, detectors have been optimized
to reach the performance required to further probe the low-mass region with
unprecedented sensitivity. In this contribution the achievements of the
CRESST-III detectors will be discussed together with preliminary results and
perspectives of Phase 1.
[5]
oai:arXiv.org:1711.01285 [pdf] - 1590722
Search for low-mass Dark Matter with the CRESST Experiment
Kluck, H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Langenkämper, A.;
Loebell, J.;
Mancuso, M.;
Mondragon, E.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Puig, R.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.
Submitted: 2017-11-03
CRESST is a multi-stage experiment directly searching for dark matter (DM)
using cryogenic $\mathrm{CaWO_4}$ crystals. Previous stages established leading
limits for the spin-independent DM-nucleon cross section down to DM-particle
masses $m_\mathrm{DM}$ below $1\,\mathrm{GeV/c^2}$. Furthermore, CRESST
performed a dedicated search for dark photons (DP) which excludes new parameter
space between DP masses $m_\mathrm{DP}$ of $300\,\mathrm{eV/c^2}$ to
$700\,\mathrm{eV/c^2}$.
In this contribution we will discuss the latest results based on the previous
CRESST-II phase 2 and we will report on the status of the current CRESST-III
phase 1: in this stage we have been operating 10 upgraded detectors with
$24,\mathrm{g}$ target mass each and enhanced detector performance since summer
2016. The improved detector design in terms of background suppression and
reduction of the detection threshold will be discussed with respect to the
previous stage. We will conclude with an outlook on the potential of the next
stage, CRESST-III phase 2.
[6]
oai:arXiv.org:1707.06749 [pdf] - 1586208
Results on MeV-scale dark matter from a gram-scale cryogenic calorimeter
operated above ground
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, A. Langenkämper J.;
Mancuso, M.;
Mondragon, E.;
Münster, A.;
Oberauer, L.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Puig, R.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoglu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2017-07-20, last modified: 2017-09-18
Models for light dark matter particles with masses below 1 GeV/c$^2$ are a
natural and well-motivated alternative to so-far unobserved weakly interacting
massive particles. Gram-scale cryogenic calorimeters provide the required
detector performance to detect these particles and extend the direct dark
matter search program of CRESST. A prototype 0.5 g sapphire detector developed
for the $\nu$-cleus experiment has achieved an energy threshold of
$E_{th}=(19.7\pm 0.9)$ eV, which is one order of magnitude lower than previous
results and independent of the type of particle interaction. The result
presented here is obtained in a setup above ground without significant
shielding against ambient and cosmogenic radiation. Although operated in a
high-background environment, the detector probes a new range of light-mass dark
matter particles previously not accessible by direct searches. We report the
first limit on the spin-independent dark matter particle-nucleon cross section
for masses between 140 MeV/c$^2$ and 500 MeV/c$^2$.
[7]
oai:arXiv.org:1706.04934 [pdf] - 1604802
First results from the NEWS-G direct dark matter search experiment at
the LSM
Collaboration, NEWS-G;
:;
Arnaud, Q.;
Asner, D.;
Bard, J. -P.;
Brossard, A.;
Cai, B.;
Chapellier, M.;
Clark, M.;
Corcoran, E. C.;
Dandl, T.;
Dastgheibi-Fard, A.;
Dering, K.;
Di Stefano, P.;
Durnford, D.;
Gerbier, G.;
Giomataris, I.;
Gorel, P.;
Gros, M.;
Guillaudin, O.;
Hoppe, E. W.;
Kamaha, A.;
Katsioulas, I.;
Kelly, D. G.;
Martin, R. D.;
McDonald, J.;
Muraz, J. -F.;
Mols, J. -P.;
Navick, X. -F.;
Papaevangelou, T.;
Piquemal, F.;
Roth, S.;
Santos, D.;
Savvidis, I.;
Ulrich, A.;
Fernandez, F. Vazquez de Sola;
Zampaolo, M.
Submitted: 2017-06-15, last modified: 2017-09-07
New Experiments With Spheres-Gas (NEWS-G) is a direct dark matter detection
experiment using Spherical Proportional Counters (SPCs) with light noble gases
to search for low-mass Weakly Interacting Massive Particles (WIMPs). We report
the results from the first physics run taken at the Laboratoire Souterrain de
Modane (LSM) with SEDINE, a 60 cm diameter prototype SPC operated with a
mixture of $\mathrm{Ne}+\mathrm{CH}_{4}$ (0.7 %) at 3.1 bars for a total
exposure of $9.7\;\mathrm{kg\cdot days}$. New constraints are set on the
spin-independent WIMP-nucleon scattering cross-section in the
sub-$\mathrm{GeV/c^2}$ mass region. We exclude cross-sections above $4.4 \times
\mathrm{10^{-37}\;cm^2}$ at 90 % confidence level (C.L.) for a 0.5
$\mathrm{GeV/c^2}$ WIMP. The competitive results obtained with SEDINE are
promising for the next phase of the NEWS-G experiment: a 140 cm diameter SPC to
be installed at SNOLAB by summer 2018.
[8]
oai:arXiv.org:1708.01581 [pdf] - 1586787
Performance of a CRESST-II Detector Module with True $4\pi$-veto
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Langenkämper, A.;
Loebell, J.;
Mancuso, M.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, V. Schipperges S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2017-08-04
Scintillating, cryogenic bolometers are widely used in the field of rare
event searches. Their main advantages are an excellent energy resolution and
particle identification on an event-by-event basis. The sensitivity of
experiments applying this detector technique can be limited by the performance
of the light channel and the presence of external backgrounds in the region of
interest. In the framework of the CRESST-II experiment, we developed and
successfully tested a novel detector design addressing both challenges. Using a
large scale ($\approx$\unit[60]{cm$^2$}), beaker-shaped silicon light absorber,
the signal height recorded in the light channel is improved by a factor 2.5
compared to conventional CRESTT-II detector modules. In combination with a
large carrier crystal, a true $4\pi$ veto system is established which allows to
tag external background sources.
[9]
oai:arXiv.org:1503.07806 [pdf] - 1530245
In-situ study of light production and transport in phonon/light detector
modules for dark matter search
Kiefer, M.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Sivers, M. v.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2015-03-26, last modified: 2017-02-20
The CRESST experiment (Cryogenic Rare Event Search with Superconducting
Thermometers) searches for dark matter via the phonon and light signals of
elastic scattering processes in scintillating crystals. The discrimination
between a possible dark matter signal and background is based on the light
yield. We present a new method for evaluating the two characteristics of a
phonon/light detector module that determine how much of the deposited energy is
converted to scintillation light and how efficiently a module detects the
produced light. In contrast to former approaches with dedicated setups, we
developed a method which allows us to use data taken with the cryogenic setup,
during a dark matter search phase. In this way, we accounted for the entire
process that occurs in a detector module, and obtained information on the light
emission of the crystal as well as information on the performance of the module
(light transport and detection). We found that with the detectors operated in
CRESST-II phase 1, about 20% of the produced scintillation light is detected. A
part of the light is likely absorbed by creating meta-stable excitations in the
scintillating crystals. The light not detected is not absorbed entirely, as an
additional light detector can help to increase the fraction of detected light.
[10]
oai:arXiv.org:1611.02113 [pdf] - 1509578
Direct Dark Matter Search with the CRESST II Experiment
Schieck, J;
Angloher, G;
Bento, A;
Bucci, C;
Canonica, L;
Defay, X;
Erb, A;
Feilitzsch, F v;
Iachellini, N Ferreiro;
Gorla, P;
Guetlein, A;
Hauff, D;
Jochum, J;
Kiefer, M;
Kluck, H;
Kraus, H;
Lanfranchi, J-C;
Loebell, J;
Mancuso, M;
Muenster, A;
Pagliarone, C;
Petricca, F;
Potzel, W;
Pröbst, F;
Puig, R;
Reindl, F;
Schaeffner, K;
Schoenert, S;
Seidel, W;
Stahlberg, M;
Stodolsky, L;
Strandhagen, C;
Strauss, R;
Tanzke, A;
Thi, H H Trinh;
Turkoglu, C;
Uffinger, M;
Ulrich, A;
Usherov, I;
Wawoczny, S;
Willers, M;
Wueustrich, M;
Zoeller, A
Submitted: 2016-11-07
The quest for the particle nature of dark matter is one of the big open
questions of modern physics. A well motivated candidate for dark matter is the
so-called WIMP - a weakly interacting massive particle. Recently several
theoretically well-motivated models with dark matter candidates in a mass
region below the WIMP mass-scale gained also a lot of interest, theoretically
and experimentally. The CRESST II experiment located at the Gran Sasso
laboratory in Italy is optimised for the detection of the elastic scattering of
these low-mass dark matter particles with ordinary matter. We show the results
obtained with an improved detector setup with increased radio purity and
enhanced background rejection and the results obtained with a dedicated
low-threshold analysis of a single conventional detector module. The limit
achieved is the most stringent limit achieved for direct dark matter
experiments in the mass region below 1.8 GeV/$c^{2}$. We will discuss the
expected performance for new small CRESST-type detectors to be used during the
next data taking phase. We conclude with an outlook of the future potential for
direct dark matter detection using further improved CRESST CaWO$_{4}$ cryogenic
detectors.
[11]
oai:arXiv.org:1601.04447 [pdf] - 1439730
Limits on momentum-dependent asymmetric dark matter with CRESST-II
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2016-01-18, last modified: 2016-07-19
The usual assumption in direct dark matter searches is to only consider the
spin-dependent or spin-independent scattering of dark matter particles.
However, especially in models with light dark matter particles
$\mathcal{O}(\mathrm{GeV/c^2})$, operators which carry additional powers of the
momentum transfer $q^2$ can become dominant. One such model based on asymmetric
dark matter has been invoked to overcome discrepancies in helioseismology and
an indication was found for a particle with preferred mass of 3
$\mathrm{GeV/c^2}$ and cross section of $10^{-37} \mathrm{cm^2}$. Recent data
from the CRESST-II experiment, which uses cryogenic detectors based on
$\mathrm{CaWO_4}$ to search for nuclear recoils induced by dark matter
particles, are used to constrain these momentum-dependent models. The low
energy threshold of 307 eV for nuclear recoils of the detector used, allows us
to rule out the proposed best fit value above.
[12]
oai:arXiv.org:1509.01515 [pdf] - 1357396
Results on light dark matter particles with a low-threshold CRESST-II
detector
The CRESST Collaboration;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Loebell, J.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2015-09-04, last modified: 2016-02-12
The CRESST-II experiment uses cryogenic detectors to search for nuclear
recoil events induced by the elastic scattering of dark matter particles in
CaWO$_4$ crystals. Given the low energy threshold of our detectors in
combination with light target nuclei, low mass dark matter particles can be
probed with high sensitivity. In this letter we present the results from data
of a single detector module corresponding to 52 kg live days. A blind analysis
is carried out. With an energy threshold for nuclear recoils of 307 eV we
substantially enhance the sensitivity for light dark matter. Thereby, we extend
the reach of direct dark matter experiments to the sub-region and demonstrate
that the energy threshold is the key parameter in the search for low mass dark
matter particles.
[13]
oai:arXiv.org:1401.3332 [pdf] - 1345758
Energy-Dependent Light Quenching in CaWO$_4$ Crystals at mK Temperatures
Strauss, R.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Carli, W.;
Ciemniak, C.;
Erb, A.;
Feilitzsch, F. v.;
Gorla, P.;
Gütlein, A.;
Hagn, H.;
Hauff, D.;
Hellgartner, D.;
Jochum, J.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Sivers, M. v.;
Stodolsky, L.;
Strandhagen, C.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2014-01-14, last modified: 2016-01-25
Scintillating CaWO$_4$ single crystals are a promising multi-element target
for rare-event searches and are currently used in the direct Dark Matter
experiment CRESST (Cryogenic Rare Event Search with Superconducting
Thermometers). The relative light output of different particle interactions in
CaWO$_4$ is quantified by Quenching Factors (QFs). These are essential for an
active background discrimination and the identification of a possible signal
induced by weakly interacting massive particles (WIMPs). We present the first
precise measurements of the QFs of O, Ca and W at mK temperatures by
irradiating a cryogenic detector with a fast neutron beam. A clear energy
dependence of the QF of O and, less pronounced, of Ca was observed for the
first time. Furthermore, in CRESST neutron-calibration data a variation of the
QFs among different CaWO$_4$ single crystals was found. For typical CRESST
detectors the QFs in the region-of-interest (10-40$\,$keV) are
$QF_O^{ROI}=(11.2{\pm}0.5)\,$%, $QF_{Ca}^{ROI}=(5.94{\pm}0.49)\,$% and
$QF_W^{ROI}=(1.72{\pm}0.21)\,$%. The latest CRESST data (run32) is reanalyzed
using these fundamentally new results on light quenching in CaWO$_4$ having
moderate influence on the WIMP analysis. Their relevance for future CRESST runs
and for the clarification of previously published results of direct Dark Matter
experiments is emphasized.
[14]
oai:arXiv.org:1410.1753 [pdf] - 1345768
A detector module with highly efficient surface-alpha event rejection
operated in CRESST-II Phase 2
Strauss, R.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Ferreiro, N.;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Sivers, M. v.;
Stanger, M.;
Stodolsky, L.;
Strandhagen, C.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2014-10-07, last modified: 2016-01-25
The cryogenic dark matter experiment CRESST-II aims at the direct detection
of WIMPs via elastic scattering off nuclei in scintillating CaWO$_4$ crystals.
We present a new, highly improved, detector design installed in the current run
of CRESST-II Phase 2 with an efficient active rejection of surface-alpha
backgrounds. Using CaWO$_4$ sticks instead of metal clamps to hold the target
crystal, a detector housing with fully-scintillating inner surface could be
realized. The presented detector (TUM40) provides an excellent threshold of
${\sim}\,0.60\,$keV and a resolution of $\sigma\,{\approx}\,0.090$ keV (at
2.60$\,$keV). With significantly reduced background levels, TUM40 sets
stringent limits on the spin-independent WIMP-nucleon scattering cross section
and probes a new region of parameter space for WIMP masses below
3$\,$GeV/c$^2$. In this paper, we discuss the novel detector design and the
surface-alpha event rejection in detail.
[15]
oai:arXiv.org:1511.07720 [pdf] - 1317176
Table-top setup for investigating the scintillation properties of liquid
argon
Submitted: 2015-11-24
The spectral and temporal light emission properties of liquid argon have been
studied in the context of its use in large liquid rare-gas detectors for
detecting Dark Matter particles in astronomy. A table-top setup has been
developed. Continuous and pulsed low energy electron beam excitation is used to
stimulate light emission. A spectral range from 110 to 1000 nm in wavelength is
covered by the detection system with a time resolution on the order of 1 ns.
[16]
oai:arXiv.org:1511.07718 [pdf] - 1317175
The scintillation of liquid argon
Submitted: 2015-11-24
A spectroscopic study of liquid argon from the vacuum ultraviolet at 110 nm
to 1000 nm is presented. Excitation was performed using continuous and pulsed
12 keV electron beams. The emission is dominated by the analogue of the so
called 2nd excimer continuum. Various additional emission features were found.
The time structure of the light emission has been measured for a set of well
defined wavelength positions. The results help to interpret literature data in
the context of liquid rare gas detectors in which the wavelength information is
lost due to the use of wavelength shifters.
[17]
oai:arXiv.org:1511.07724 [pdf] - 1317180
Attenuation of vacuum ultraviolet light in liquid argon
Submitted: 2015-11-24
The transmission of liquid argon has been measured, wavelength resolved, for
a wavelength interval from 118 to 250 nm. The wavelength dependent attenuation
length is presented for pure argon. It is shown that no universal wavelength
independent attenuation length can be assigned to liquid argon for its own
fluorescence light due to the interplay between the wavelength dependent
emission and absorption. A decreasing transmission is observed below 130 nm in
both chemically cleaned and distilled liquid argon and assigned to absorption
by the analogue of the first argon excimer continuum. For not perfectly cleaned
argon a strong influence of impurities on the transmission is observed. Two
strong absorption bands at 126.5 and 141.0 nm with approximately 2 and 4 nm
width, respectively, are assigned to traces of xenon in argon. A broad
absorption region below 180 nm is found for unpurified argon and tentatively
attributed to the presence of water in the argon sample.
[18]
oai:arXiv.org:1511.07721 [pdf] - 1317177
Ion-beam excitation of liquid argon
Hofmann, M.;
Dandl, T.;
Heindl, T.;
Neumeier, A.;
Oberauer, L.;
Potzel, W.;
Roth, S.;
Schönert, S.;
Wieser, J.;
Ulrich, A.
Submitted: 2015-11-24
The scintillation light of liquid argon has been recorded wavelength and time
resolved with very good statistics in a wavelength interval ranging from 118 nm
through 970 nm. Three different ion beams, protons, sulfur ions and gold ions,
were used to excite liquid argon. Only minor differences were observed in the
wavelength-spectra obtained with the different incident particles. Light
emission in the wavelength range of the third excimer continuum was found to be
strongly suppressed in the liquid phase. In time-resolved measurements, the
time structure of the scintillation light can be directly attributed to
wavelength in our studies, as no wavelength shifter has been used. These
measurements confirm that the singlet-to-triplet intensity ratio in the second
excimer continuum range is a useful parameter for particle discrimination,
which can also be employed in wavelength-integrated measurements as long as the
sensitivity of the detector system does not rise steeply for wavelengths longer
than 190 nm. Using our values for the singlet-to-triplet ratio down to low
energies deposited a discrimination threshold between incident protons and
sulfur ions as low as $\sim$2.5 keV seems possible, which represents the
principle limit for the discrimination of these two species in liquid argon.
[19]
oai:arXiv.org:1511.07723 [pdf] - 1317179
Intense Vacuum-Ultraviolet and Infrared Scintillation of Liquid Ar-Xe
Mixtures
Neumeier, A.;
Dandl, T.;
Heindl, T.;
Himpsl, A.;
Oberauer, L.;
Potzel, W.;
Roth, S.;
Schönert, S.;
Wieser, J.;
Ulrich, A.
Submitted: 2015-11-24
Vacuum ultraviolet light emission from xenon-doped liquid argon is described
in the context of liquid noble gas particle detectors. Xenon concentrations in
liquid argon from 0.1 ppm to 1000 ppm were studied. The energy transfer from
the second excimer continuum of argon ($\sim$127 nm) to the second excimer
continuum of xenon ($\sim$174 nm) is observed by recording optical emission
spectra. The transfer almost saturates at a xenon concentration of $\sim$10 ppm
for which, in addition, an intense emission in the infrared at a peak
wavelength of 1.17 $\mu$m with (13000$\pm$4000) photons per MeV deposited by
electrons had been found. The corresponding value for the VUV emission at a
peak wavelength of 174 nm (second excimer continuum of xenon) is determined to
be (20000$\pm$6000) photons per MeV electron energy deposited. Under these
excitation conditions pure liquid argon emits (22000$\pm$3000) photons per MeV
electron energy deposited at a peak wavelength of 127nm. An electron-beam
induced emission spectrum for the 10 ppm Ar-Xe liquid mixture ranging from 115
nm to 3.5 $\mu$m is presented. VUV emission spectra from xenon-doped liquid
argon with exponentially varied xenon concentrations from 0.1 ppm to 1000 ppm
are also shown. Time structure measurements of the light emissions at
well-defined wavelength positions in the vacuum ultraviolet as well as in the
near-infrared are presented.
[20]
oai:arXiv.org:1511.07725 [pdf] - 1317181
Attenuation of vacuum ultraviolet light in pure and xenon-doped liquid
argon - an approach to an assignment of the near-infrared emission from the
mixture
Submitted: 2015-11-24
Results of transmission experiments of vacuum ultraviolet light through a
11.6 cm long cell filled with pure and xenon-doped liquid argon are described.
Pure liquid argon shows no attenuation down to the experimental
short-wavelength cut-off at 118nm. Based on a conservative approach, a lower
limit of 1.10 m for the attenuation length of its own scintillation light could
be derived. Adding xenon to liquid argon at concentrations on the order of
parts per million leads to strong xenon-related absorption features which are
used for a tentative assignment of the recently found near-infrared emission
observed in electron-beam excited liquid argon-xenon mixtures. Two of the three
absorption features can be explained by perturbed xenon transitions and the
third one by a trapped exciton (Wannier-Mott) impurity state. A calibration
curve connecting the equivalent width of the absorption line at 140 nm with
xenon concentration is provided.
[21]
oai:arXiv.org:1511.07722 [pdf] - 1317178
Intense Infrared Scintillation of Liquid Ar-Xe Mixtures
Neumeier, A.;
Dandl, T.;
Heindl, T.;
Himpsl, A.;
Hagn, H.;
Hofmann, M.;
Oberauer, L.;
Potzel, W.;
Roth, S.;
Schönert, S.;
Wieser, J.;
Ulrich, A.
Submitted: 2015-11-24
Intense infrared (IR) light emission from liquid Ar-Xe mixtures has been
observed using 12 keV electron-beam excitation. The emission peaks at a
wavelength of 1.18 $\mu$m and the half-width of the emission band is 0.1
$\mu$m. Maximum intensity has been found for a 10 ppm xenon admixture in liquid
argon. The conversion efficiency of electron beam-power to IR-light is about 1%
(10000 photons per MeV electron energy deposited). A possible application of
this intense IR emission for a new particle discrimination concept in liquid
noble gas detectors is discussed. No light emission was found for perfectly
purified liquid argon in the wavelength range from 0.5 to 3.5 $\mu$m on the
current level of sensitivity.
[22]
oai:arXiv.org:1511.07726 [pdf] - 1317182
Attenuation measurements of vacuum ultraviolet light in liquid argon
revisited
Submitted: 2015-11-24
The attenuation of vacuum ultraviolet light in liquid argon in the context of
its application in large liquid noble gas detectors has been studied. Compared
to a previous publication several technical issues concerning transmission
measurements in general are addressed and several systematic effects were
quantitatively measured. Wavelength-resolved transmission measurements have
been performed from the vacuum ultraviolet to the near-infrared region. On the
current level of sensitivity with a length of the optical path of 11.6 cm, no
xenon-related absorption effects could be observed, and pure liquid argon is
fully transparent down to the short wavelength cut-off of the experimental
setup at 118 nm. A lower limit for the attenuation length of pure liquid argon
for its own scintillation light has been estimated to be 1.10 m based on a very
conservative approach.
[23]
oai:arXiv.org:1509.09124 [pdf] - 1286174
The CRESST Dark Matter Search - Status and Perspectives
The CRESST Collaboration;
Reindl, F.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Loebell, J.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2015-09-30
In the past years the spotlight of the search for dark matter particles
widened to the low mass region, both from theoretical and experimental side. We
discuss results from data obtained in 2013 with a single detector TUM40. This
detector is equipped with a new upgraded holding scheme to efficiently veto
backgrounds induced by surface alpha decays. This veto, the low threshold of
0.6keV and an unprecedented background level for CaWO$_4$ target crystals
render TUM40 the detector with the best overall performance of CRESST-II phase
2 (July 2013 - August 2015). A low-threshold analysis allowed to investigate
light dark matter particles (<3GeV/c$^2$), previously not accessible for other
direct detection experiments.
[24]
oai:arXiv.org:1503.08065 [pdf] - 972114
Probing low WIMP masses with the next generation of CRESST detector
The CRESST Collaboration;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Schäffner, K.;
Schieck, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2015-03-27
The purpose of this document is to describe the upgrade of the CRESST dark
matter search at LNGS. The proposed strategy will allow to explore a region of
the parameter space for spin-independent WIMP-nucleon elastic scattering
corresponding to WIMP masses below 10GeV/c$^\text{2}$, that has not been
covered by other experiments. These results can be achieved only with
outstanding detector performances in terms of threshold and background. This
proposal shows how CRESST can match these performance requirements, adding a
unique piece of information to the dark matter puzzle. The results of this
program will fix a new state-of-the-art in the low mass WIMP exploration,
opening new perspectives of understanding the dark matter scenario.
[25]
oai:arXiv.org:1407.3146 [pdf] - 925077
Results on low mass WIMPs using an upgraded CRESST-II detector
CRESST Collaboration;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Huff, P.;
Jochum, J.;
Kiefer, M.;
Kister, C.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Schmaler, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Sivers, M. v.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2014-07-11, last modified: 2015-01-22
The CRESST-II cryogenic dark matter search aims for the detection of WIMPs
via elastic scattering off nuclei in CaWO$_4$ crystals. We present results from
a low-threshold analysis of a single upgraded detector module. This module
efficiently vetoes low energy backgrounds induced by $\alpha$-decays on inner
surfaces of the detector. With an exposure of \unit[29.35]{kg live days}
collected in 2013 we set a limit on spin-independent WIMP-nucleon scattering
which probes a new region of parameter space for WIMP masses below
\unit[3]{GeV/c$^2$}, previously not covered in direct detection searches. A
possible excess over background discussed for the previous CRESST-II phase 1
(from 2009 to 2011) is not confirmed.
[26]
oai:arXiv.org:1501.04617 [pdf] - 923076
Microscopic Model for the Scintillation-Light Generation and
Light-Quenching in CaWO$_4$ single crystals
Submitted: 2015-01-19
Scintillators are employed for particle detection and identification using
light-pulse shapes and light quenching factors. We developed a comprehensive
model describing the light generation and quenching in CaWO$_4$ single crystals
used for direct dark matter search. All observed particle-dependent
light-emission characteristics can be explained quantitatively, light-quenching
factors and light-pulse shapes are calculated on a microscopic basis. This
model can be extended to other scintillators such as inorganic crystal
scintillators, liquid noble gases or organic liquid scintillators.
[27]
oai:arXiv.org:1403.5114 [pdf] - 1175712
Radiopurity of CaWO$_4$ Crystals for Direct Dark Matter Search with
CRESST and EURECA
Münster, A.;
Sivers, M. v.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kraus, H.;
Lanfranchi, J. -C.;
Laubenstein, M.;
Loebell, J.;
Ortigoza, Y.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Puimedon, J.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2014-03-20, last modified: 2014-05-07
The direct dark matter search experiment CRESST uses scintillating CaWO$_4$
single crystals as targets for possible WIMP scatterings. An intrinsic
radioactive contamination of the crystals as low as possible is crucial for the
sensitivity of the detectors. In the past CaWO$_4$ crystals operated in CRESST
were produced by institutes in Russia and the Ukraine. Since 2011 CaWO$_4$
crystals have also been grown at the crystal laboratory of the Technische
Universit\"at M\"unchen (TUM) to better meet the requirements of CRESST and of
the future tonne-scale multi-material experiment EURECA. The radiopurity of the
raw materials and of first TUM-grown crystals was measured by ultra-low
background $\gamma$-spectrometry. Two TUM-grown crystals were also operated as
low-temperature detectors at a test setup in the Gran Sasso underground
laboratory. These measurements were used to determine the crystals' intrinsic
$\alpha$-activities which were compared to those of crystals produced at other
institutes. The total $\alpha$-activities of TUM-grown crystals as low as 1.23
$\pm$ 0.06 mBq/kg were found to be significantly smaller than the activities of
crystals grown at other institutes typically ranging between ~15 mBq/kg and ~35
mBq/kg.
[28]
oai:arXiv.org:1210.1319 [pdf] - 1151859
Nitrogen fluorescence in air for observing extensive air showers
Submitted: 2012-10-04, last modified: 2012-12-10
Extensive air showers initiate the fluorescence emissions from nitrogen
molecules in air. The UV-light is emitted isotropically and can be used for
observing the longitudinal development of extensive air showers in the
atmosphere over tenth of kilometers. This measurement technique is
well-established since it is exploited for many decades by several cosmic ray
experiments. However, a fundamental aspect of the air shower analyses is the
description of the fluorescence emission in dependence on varying atmospheric
conditions. Different fluorescence yields affect directly the energy scaling of
air shower reconstruction. In order to explore the various details of the
nitrogen fluorescence emission in air, a few experimental groups have been
performing dedicated measurements over the last decade. Most of the
measurements are now finished. These experimental groups have been discussing
their techniques and results in a series of Air Fluorescence Workshops
commenced in 2002. At the 8$^{\rm{th}}$ Air Fluorescence Workshop 2011, it was
suggested to develop a common way of describing the nitrogen fluorescence for
application to air shower observations. Here, first analyses for a common
treatment of the major dependences of the emission procedure are presented.
Aspects like the contributions at different wavelengths, the dependence on
pressure as it is decreasing with increasing altitude in the atmosphere, the
temperature dependence, in particular that of the collisional cross sections
between molecules involved, and the collisional de-excitation by water vapor
are discussed.
[29]
oai:arXiv.org:1210.6734 [pdf] - 1152436
Precise measurement of the absolute fluorescence yield of the 337 nm
band in atmospheric gases
AIRFLY Collaboration;
Ave, M.;
Bohacova, M.;
Curry, E.;
Di Carlo, P.;
Di Giulio, C.;
Luis, P. Facal San;
Gonzales, D.;
Hojvat, C.;
Hörandel, J.;
Hrabovsky, M.;
Iarlori, M.;
Keilhauer, B.;
Klages, H.;
Kleifges, M.;
Kuehn, F.;
Li, S.;
Monasor, M.;
Nozka, L.;
Palatka, M.;
Petrera, S.;
Privitera, P.;
Ridky, J.;
Rizi, V.;
D'Orfeuil, B. Rouille;
Salamida, F.;
Schovanek, P.;
Smida, R.;
Spinka, H.;
Ulrich, A.;
Verzi, V.;
Williams, C.
Submitted: 2012-10-24
A measurement of the absolute fluorescence yield of the 337 nm nitrogen band,
relevant to ultra-high energy cosmic ray (UHECR) detectors, is reported. Two
independent calibrations of the fluorescence emission induced by a 120 GeV
proton beam were employed: Cherenkov light from the beam particle and
calibrated light from a nitrogen laser. The fluorescence yield in air at a
pressure of 1013 hPa and temperature of 293 K was found to be $Y_{337} =
5.61\pm 0.06_{stat} \pm 0.21_{syst}$ photons/MeV. When compared to the
fluorescence yield currently used by UHECR experiments, this measurement
improves the uncertainty by a factor of three, and has a significant impact on
the determination of the energy scale of the cosmic ray spectrum.
[30]
oai:arXiv.org:1101.3799 [pdf] - 368083
Precise Measurement of the Absolute Yield of Fluorescence Photons in
Atmospheric Gases
AIRFLY Collaboration;
Ave, M.;
Boháčová, M.;
Daumiller, K.;
Di Carlo, P.;
Di Giulio, C.;
Luis, P. Facal San;
Gonzales, D.;
Hojvat, C.;
Hörandel, J. R.;
Hrabovský, M.;
Iarlori, M.;
Keilhauer, B.;
Klages, H.;
Kleifges, M.;
Kuehn, F.;
Monasor, M.;
Nožka, L.;
Palatka, M.;
Petrera, S.;
Privitera, P.;
Ridky, J.;
Rizi, V.;
d'Orfeuil, B. Rouillé;
Salamida, F.;
Schovánek, P.;
Šmida, R.;
Spinka, H.;
Ulrich, A.;
Verzi, V.;
Williams, C.
Submitted: 2011-01-19
We have performed a measurement of the absolute yield of fluorescence photons
at the Fermilab Test Beam. A systematic uncertainty at 5% level was achieved by
the use of Cherenkov radiation as a reference calibration light source. A
cross-check was performed by an independent calibration using a laser light
source. A significant improvement on the energy scale uncertainty of Ultra-High
Energy Cosmic Rays is expected.