sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Ullom, Joel N.

Normalized to: Ullom, J.

41 article(s) in total. 861 co-authors, from 1 to 27 common article(s). Median position in authors list is 25,0.

[1]  oai:arXiv.org:2007.00638  [pdf] - 2126373
A three-wave mixing kinetic inductance traveling-wave amplifier with near-quantum-limited noise performance
Comments:
Submitted: 2020-07-01
We present a theoretical model and experimental characterization of a microwave kinetic inductance traveling-wave amplifier (KIT), whose noise performance, measured by a shot noise thermometer, approaches the quantum limit. Biased with a dc current, the KIT operates in a three-wave mixing fashion, thereby reducing by several orders of magnitude the power of the microwave pump tone compared to conventional four-wave mixing KIT devices. It is built in an artificial transmission line intrinsically matched to 50 Ohms, whose dispersion allows for a controlled amplification bandwidth. We experimentally measure $17.6^{+1.1}_{-1.4}$ dB of gain across a 2 GHz bandwidth, with an input 1 dB compression power of -63 dBm within that bandwidth, in qualitative agreement with theory. Using the KIT as the first amplifier in an amplification chain, we measure a system-added noise of $0.61\pm0.08$ K between 3.5 and 5.5 GHz, about one eighth the noise obtained when using only a representative classical amplifier. The KIT contribution to this added noise is estimated to be $0.2\pm0.1$ K, consistent with the quantum limit on amplifier added noise. This device is therefore suitable to read large arrays of microwave kinetic inductance detectors or thousands of superconducting qubits.
[2]  oai:arXiv.org:2003.08949  [pdf] - 2067603
Simons Observatory Microwave SQUID Multiplexing Readout -- Cryogenic RF Amplifier and Coaxial Chain Design
Comments: 10 pages, 2 figures
Submitted: 2020-03-19
The Simons Observatory (SO) is an upcoming polarization-sensitive Cosmic Microwave Background (CMB) experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of \bigO(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiplexing factor of \bigO{(1,000)}, microwave SQUID multiplexing has never been deployed on the scale needed for SO. Here we present the design of the cryogenic coaxial cable and RF component chain that connects room temperature readout electronics to superconducting resonators that are coupled to Transition Edge Sensor bolometers operating at sub-Kelvin temperatures. We describe design considerations including cryogenic RF component selection, system linearity, noise, and thermal power dissipation.
[3]  oai:arXiv.org:1912.00860  [pdf] - 2065329
Characterization of Transition Edge Sensors for the Simons Observatory
Comments: 9 Pages, 5 figures, Low Temperature Detectors 19
Submitted: 2019-12-02, last modified: 2020-01-21
The Simons Observatory is building both large (6 m) and small (0.5 m) aperture telescopes in the Atacama desert in Chile to observe the cosmic microwave background (CMB) radiation with unprecedented sensitivity. Simons Observatory telescopes in total will use over 60,000 transition edge sensor (TES) detectors spanning center frequencies between 27 and 285 GHz and operating near 100 mK. TES devices have been fabricated for the Simons Observatory by NIST, Berkeley, and HYPRES/SeeQC corporation. Iterations of these devices have been tested cryogenically in order to inform the fabrication of further devices, which will culminate in the final TES designs to be deployed in the field. The detailed design specifications have been independently iterated at each fabrication facility for particular detector frequencies. We present test results for prototype devices, with emphasis on NIST high frequency detectors. A dilution refrigerator was used to achieve the required temperatures. Measurements were made both with 4-lead resistance measurements and with a time domain Superconducting Quantum Interference Device (SQUID) multiplexer system. The SQUID readout measurements include analysis of current vs voltage (IV) curves at various temperatures, square wave bias step measurements, and detector noise measurements. Normal resistance, superconducting critical temperature, saturation power, thermal and natural time constants, and thermal properties of the devices are extracted from these measurements.
[4]  oai:arXiv.org:1909.01305  [pdf] - 2034407
Microwave multiplexing on the Keck Array
Comments: 9 pages, 11 figures, Accepted by the Journal of Low Temperature Physics (Proceedings of the 18th International Workshop on Low Temperature Detectors)
Submitted: 2019-09-03, last modified: 2020-01-17
We describe an on-sky demonstration of a microwave-multiplexing readout system in one of the receivers of the Keck Array, a polarimetry experiment observing the cosmic microwave background at the South Pole. During the austral summer of 2018-2019, we replaced the time-division multiplexing readout system with microwave-multiplexing components including superconducting microwave resonators coupled to radio-frequency superconducting quantum interference devices at the sub-Kelvin focal plane, coaxial-cable plumbing and amplification between room temperature and the cold stages, and a SLAC Microresonator Radio Frequency system for the warm electronics. In the range 5-6 GHz, a single coaxial cable reads out 528 channels. The readout system is coupled to transition-edge sensors, which are in turn coupled to 150-GHz slot-dipole phased-array antennas. Observations began in April 2019, and we report here on an initial characterization of the system performance.
[5]  oai:arXiv.org:2001.01724  [pdf] - 2026608
Updated design of the CMB polarization experiment satellite LiteBIRD
Sugai, H.; Ade, P. A. R.; Akiba, Y.; Alonso, D.; Arnold, K.; Aumont, J.; Austermann, J.; Baccigalupi, C.; Banday, A. J.; Banerji, R.; Barreiro, R. B.; Basak, S.; Beall, J.; Beckman, S.; Bersanelli, M.; Borrill, J.; Boulanger, F.; Brown, M. L.; Bucher, M.; Buzzelli, A.; Calabrese, E.; Casas, F. J.; Challinor, A.; Chan, V.; Chinone, Y.; Cliche, J. -F.; Columbro, F.; Cukierman, A.; Curtis, D.; Danto, P.; de Bernardis, P.; de Haan, T.; De Petris, M.; Dickinson, C.; Dobbs, M.; Dotani, T.; Duband, L.; Ducout, A.; Duff, S.; Duivenvoorden, A.; Duval, J. -M.; Ebisawa, K.; Elleflot, T.; Enokida, H.; Eriksen, H. K.; Errard, J.; Essinger-Hileman, T.; Finelli, F.; Flauger, R.; Franceschet, C.; Fuskeland, U.; Ganga, K.; Gao, J. -R.; Génova-Santos, R.; Ghigna, T.; Gomez, A.; Gradziel, M. L.; Grain, J.; Grupp, F.; Gruppuso, A.; Gudmundsson, J. E.; Halverson, N. W.; Hargrave, P.; Hasebe, T.; Hasegawa, M.; Hattori, M.; Hazumi, M.; Henrot-Versille, S.; Herranz, D.; Hill, C.; Hilton, G.; Hirota, Y.; Hivon, E.; Hlozek, R.; Hoang, D. -T.; Hubmayr, J.; Ichiki, K.; Iida, T.; Imada, H.; Ishimura, K.; Ishino, H.; Jaehnig, G. C.; Jones, M.; Kaga, T.; Kashima, S.; Kataoka, Y.; Katayama, N.; Kawasaki, T.; Keskitalo, R.; Kibayashi, A.; Kikuchi, T.; Kimura, K.; Kisner, T.; Kobayashi, Y.; Kogiso, N.; Kogut, A.; Kohri, K.; Komatsu, E.; Komatsu, K.; Konishi, K.; Krachmalnicoff, N.; Kuo, C. L.; Kurinsky, N.; Kushino, A.; Kuwata-Gonokami, M.; Lamagna, L.; Lattanzi, M.; Lee, A. T.; Linder, E.; Maffei, B.; Maino, D.; Maki, M.; Mangilli, A.; Martínez-González, E.; Masi, S.; Mathon, R.; Matsumura, T.; Mennella, A.; Migliaccio, M.; Minami, Y.; Mistuda, K.; Molinari, D.; Montier, L.; Morgante, G.; Mot, B.; Murata, Y.; Murphy, J. A.; Nagai, M.; Nagata, R.; Nakamura, S.; Namikawa, T.; Natoli, P.; Nerva, S.; Nishibori, T.; Nishino, H.; Nomura, Y.; Noviello, F.; O'Sullivan, C.; Ochi, H.; Ogawa, H.; Ogawa, H.; Ohsaki, H.; Ohta, I.; Okada, N.; Okada, N.; Pagano, L.; Paiella, A.; Paoletti, D.; Patanchon, G.; Piacentini, F.; Pisano, G.; Polenta, G.; Poletti, D.; Prouvé, T.; Puglisi, G.; Rambaud, D.; Raum, C.; Realini, S.; Remazeilles, M.; Roudil, G.; Rubiño-Martín, J. A.; Russell, M.; Sakurai, H.; Sakurai, Y.; Sandri, M.; Savini, G.; Scott, D.; Sekimoto, Y.; Sherwin, B. D.; Shinozaki, K.; Shiraishi, M.; Shirron, P.; Signorelli, G.; Smecher, G.; Spizzi, P.; Stever, S. L.; Stompor, R.; Sugiyama, S.; Suzuki, A.; Suzuki, J.; Switzer, E.; Takaku, R.; Takakura, H.; Takakura, S.; Takeda, Y.; Taylor, A.; Taylor, E.; Terao, Y.; Thompson, K. L.; Thorne, B.; Tomasi, M.; Tomida, H.; Trappe, N.; Tristram, M.; Tsuji, M.; Tsujimoto, M.; Tucker, C.; Ullom, J.; Uozumi, S.; Utsunomiya, S.; Van Lanen, J.; Vermeulen, G.; Vielva, P.; Villa, F.; Vissers, M.; Vittorio, N.; Voisin, F.; Walker, I.; Watanabe, N.; Wehus, I.; Weller, J.; Westbrook, B.; Winter, B.; Wollack, E.; Yamamoto, R.; Yamasaki, N. Y.; Yanagisawa, M.; Yoshida, T.; Yumoto, J.; Zannoni, M.; Zonca, A.
Comments: Journal of Low Temperature Physics, in press
Submitted: 2020-01-06
Recent developments of transition-edge sensors (TESs), based on extensive experience in ground-based experiments, have been making the sensor techniques mature enough for their application on future satellite CMB polarization experiments. LiteBIRD is in the most advanced phase among such future satellites, targeting its launch in Japanese Fiscal Year 2027 (2027FY) with JAXA's H3 rocket. It will accommodate more than 4000 TESs in focal planes of reflective low-frequency and refractive medium-and-high-frequency telescopes in order to detect a signature imprinted on the cosmic microwave background (CMB) by the primordial gravitational waves predicted in cosmic inflation. The total wide frequency coverage between 34GHz and 448GHz enables us to extract such weak spiral polarization patterns through the precise subtraction of our Galaxy's foreground emission by using spectral differences among CMB and foreground signals. Telescopes are cooled down to 5Kelvin for suppressing thermal noise and contain polarization modulators with transmissive half-wave plates at individual apertures for separating sky polarization signals from artificial polarization and for mitigating from instrumental 1/f noise. Passive cooling by using V-grooves supports active cooling with mechanical coolers as well as adiabatic demagnetization refrigerators. Sky observations from the second Sun-Earth Lagrangian point, L2, are planned for three years. An international collaboration between Japan, USA, Canada, and Europe is sharing various roles. In May 2019, the Institute of Space and Astronautical Science (ISAS), JAXA selected LiteBIRD as the strategic large mission No. 2.
[6]  oai:arXiv.org:1908.09689  [pdf] - 2022786
First Operation of TES Microcalorimeters in Space with the Micro-X Sounding Rocket
Comments: 9 pages, 6 figures, Accepted to the JLTP for LTD-18
Submitted: 2019-08-26, last modified: 2020-01-05
Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter array to perform high-resolution X-ray spectroscopy. This instrument flew for the first time on July 22nd, 2018 from the White Sands Missile Range, USA. This flight marks the first successful operation of a Transition-Edge Sensor array and its time division multiplexing read-out system in space. This launch was dedicated to the observation of the supernova remnant Cassiopeia A. A failure in the attitude control system prevented the rocket from pointing and led to no time on target. The on-board calibration source provided X-rays in flight, and it is used to compare detector performance during pre-flight integration, flight, and after the successful post-flight recovery. This calibration data demonstrates the capabilities of the detector in a space environment as well as its potential for future flights.
[7]  oai:arXiv.org:1909.11569  [pdf] - 2038283
Demonstration of 220/280 GHz Multichroic Feedhorn-Coupled TES Polarimeter
Comments: Proceedings for the 18th International Workshop on Low Temperature Detectors (LTD18), submitted to the Journal of Low Temperature Physics
Submitted: 2019-09-25, last modified: 2019-12-26
We describe the design and measurement of feedhorn-coupled, transition-edge sensor (TES) polarimeters with two passbands centered at 220 GHz and 280 GHz, intended for observations of the cosmic microwave background. Each pixel couples polarized light in two linear polarizations by use of a planar orthomode transducer and senses power via four TES bolometers, one for each band in each linear polarization. Previous designs of this detector architecture incorporated passbands from 27 GHz to 220 GHz; we now demonstrate this technology at frequencies up to 315 GHz. Observational passbands are defined with an on-chip diplexer, and Fourier-transform-spectrometer measurements are in excellent agreement with simulations. We find coupling from feedhorn to TES bolometer using a cryogenic, temperature-controlled thermal source. We determine the optical efficiency of our device is $\eta$ = 77%$\pm$6% (75%$\pm$5%) for 220 (280) GHz, relative to the designed passband shapes. Lastly, we compare two power-termination schemes commonly used in wide-bandwidth millimeter-wave polarimeters and find equal performance in terms of optical efficiency and passband shape.
[8]  oai:arXiv.org:1808.05058  [pdf] - 2014366
Cold optical design for the Large Aperture Simons Observatory telescope
Comments:
Submitted: 2018-08-15, last modified: 2019-12-13
The Simons Observatory will consist of a single large (6 m diameter) telescope and a number of smaller (0.5 m diameter) refracting telescopes designed to measure the polarization of the Cosmic Microwave Background to unprecedented accuracy. The large aperture telescope is the same design as the CCAT-prime telescope, a modified Crossed Dragone design with a field-of-view of over 7.8 degrees diameter at 90 GHz. This paper presents an overview of the cold reimaging optics for this telescope and what drove our choice of 350-400 mm diameter silicon lenses in a 2.4 m cryostat over other possibilities. We will also consider the future expandability of this design to CMB Stage-4 and beyond.
[9]  oai:arXiv.org:1912.02902  [pdf] - 2065335
Characterization of aliased noise in the Advanced ACTPol receiver
Comments:
Submitted: 2019-12-05
Advanced ACTPol is the second generation polarization-sensitive upgrade to the $6\, \rm m$ aperture Atacama Cosmology Telescope (ACT), which increased detector count and frequency coverage compared to the previous ACTPol receiver. Advanced ACTPol utilizes a new two-stage time-division multiplexing readout architecture based on superconducting quantum interference devices (SQUIDs) to achieve a multiplexing factor as high as 64 (rows), fielding a 2,012 detector camera at 150/220 GHz and two 90/150 GHz cameras containing 1,716 detectors each. In a time domain system, aliasing introduces noise to the readout. In this work we present a figure of merit to measure this noise contribution and present measurements of the aliased noise fraction of the Advanced ACTPol receiver as deployed.
[10]  oai:arXiv.org:1907.08284  [pdf] - 1976842
The Simons Observatory: Astro2020 Decadal Project Whitepaper
The Simons Observatory Collaboration; Abitbol, Maximilian H.; Adachi, Shunsuke; Ade, Peter; Aguirre, James; Ahmed, Zeeshan; Aiola, Simone; Ali, Aamir; Alonso, David; Alvarez, Marcelo A.; Arnold, Kam; Ashton, Peter; Atkins, Zachary; Austermann, Jason; Awan, Humna; Baccigalupi, Carlo; Baildon, Taylor; Lizancos, Anton Baleato; Barron, Darcy; Battaglia, Nick; Battye, Richard; Baxter, Eric; Bazarko, Andrew; Beall, James A.; Bean, Rachel; Beck, Dominic; Beckman, Shawn; Beringue, Benjamin; Bhandarkar, Tanay; Bhimani, Sanah; Bianchini, Federico; Boada, Steven; Boettger, David; Bolliet, Boris; Bond, J. Richard; Borrill, Julian; Brown, Michael L.; Bruno, Sarah Marie; Bryan, Sean; Calabrese, Erminia; Calafut, Victoria; Calisse, Paolo; Carron, Julien; Carl, Fred. M; Cayuso, Juan; Challinor, Anthony; Chesmore, Grace; Chinone, Yuji; Chluba, Jens; Cho, Hsiao-Mei Sherry; Choi, Steve; Clark, Susan; Clarke, Philip; Contaldi, Carlo; Coppi, Gabriele; Cothard, Nicholas F.; Coughlin, Kevin; Coulton, Will; Crichton, Devin; Crowley, Kevin D.; Crowley, Kevin T.; Cukierman, Ari; D'Ewart, John M.; Dünner, Rolando; de Haan, Tijmen; Devlin, Mark; Dicker, Simon; Dober, Bradley; Duell, Cody J.; Duff, Shannon; Duivenvoorden, Adri; Dunkley, Jo; Bouhargani, Hamza El; Errard, Josquin; Fabbian, Giulio; Feeney, Stephen; Fergusson, James; Ferraro, Simone; Fluxà, Pedro; Freese, Katherine; Frisch, Josef C.; Frolov, Andrei; Fuller, George; Galitzki, Nicholas; Gallardo, Patricio A.; Ghersi, Jose Tomas Galvez; Gao, Jiansong; Gawiser, Eric; Gerbino, Martina; Gluscevic, Vera; Goeckner-Wald, Neil; Golec, Joseph; Gordon, Sam; Gralla, Megan; Green, Daniel; Grigorian, Arpi; Groh, John; Groppi, Chris; Guan, Yilun; Gudmundsson, Jon E.; Halpern, Mark; Han, Dongwon; Hargrave, Peter; Harrington, Kathleen; Hasegawa, Masaya; Hasselfield, Matthew; Hattori, Makoto; Haynes, Victor; Hazumi, Masashi; Healy, Erin; Henderson, Shawn W.; Hensley, Brandon; Hervias-Caimapo, Carlos; Hill, Charles A.; Hill, J. Colin; Hilton, Gene; Hilton, Matt; Hincks, Adam D.; Hinshaw, Gary; Hložek, Renée; Ho, Shirley; Ho, Shuay-Pwu Patty; Hoang, Thuong D.; Hoh, Jonathan; Hotinli, Selim C.; Huang, Zhiqi; Hubmayr, Johannes; Huffenberger, Kevin; Hughes, John P.; Ijjas, Anna; Ikape, Margaret; Irwin, Kent; Jaffe, Andrew H.; Jain, Bhuvnesh; Jeong, Oliver; Johnson, Matthew; Kaneko, Daisuke; Karpel, Ethan D.; Katayama, Nobuhiko; Keating, Brian; Keskitalo, Reijo; Kisner, Theodore; Kiuchi, Kenji; Klein, Jeff; Knowles, Kenda; Kofman, Anna; Koopman, Brian; Kosowsky, Arthur; Krachmalnicoff, Nicoletta; Kusaka, Akito; LaPlante, Phil; Lashner, Jacob; Lee, Adrian; Lee, Eunseong; Lewis, Antony; Li, Yaqiong; Li, Zack; Limon, Michele; Linder, Eric; Liu, Jia; Lopez-Caraballo, Carlos; Louis, Thibaut; Lungu, Marius; Madhavacheril, Mathew; Mak, Daisy; Maldonado, Felipe; Mani, Hamdi; Mates, Ben; Matsuda, Frederick; Maurin, Loïc; Mauskopf, Phil; May, Andrew; McCallum, Nialh; McCarrick, Heather; McKenney, Chris; McMahon, Jeff; Meerburg, P. Daniel; Mertens, James; Meyers, Joel; Miller, Amber; Mirmelstein, Mark; Moodley, Kavilan; Moore, Jenna; Munchmeyer, Moritz; Munson, Charles; Murata, Masaaki; Naess, Sigurd; Namikawa, Toshiya; Nati, Federico; Navaroli, Martin; Newburgh, Laura; Nguyen, Ho Nam; Nicola, Andrina; Niemack, Mike; Nishino, Haruki; Nishinomiya, Yume; Orlowski-Scherer, John; Pagano, Luca; Partridge, Bruce; Perrotta, Francesca; Phakathi, Phumlani; Piccirillo, Lucio; Pierpaoli, Elena; Pisano, Giampaolo; Poletti, Davide; Puddu, Roberto; Puglisi, Giuseppe; Raum, Chris; Reichardt, Christian L.; Remazeilles, Mathieu; Rephaeli, Yoel; Riechers, Dominik; Rojas, Felipe; Rotti, Aditya; Roy, Anirban; Sadeh, Sharon; Sakurai, Yuki; Salatino, Maria; Rao, Mayuri Sathyanarayana; Saunders, Lauren; Schaan, Emmanuel; Schmittfull, Marcel; Sehgal, Neelima; Seibert, Joseph; Seljak, Uros; Shellard, Paul; Sherwin, Blake; Shimon, Meir; Sierra, Carlos; Sievers, Jonathan; Sifon, Cristobal; Sikhosana, Precious; Silva-Feaver, Maximiliano; Simon, Sara M.; Sinclair, Adrian; Smith, Kendrick; Sohn, Wuhyun; Sonka, Rita; Spergel, David; Spisak, Jacob; Staggs, Suzanne T.; Stein, George; Stevens, Jason R.; Stompor, Radek; Suzuki, Aritoki; Tajima, Osamu; Takakura, Satoru; Teply, Grant; Thomas, Daniel B.; Thorne, Ben; Thornton, Robert; Trac, Hy; Treu, Jesse; Tsai, Calvin; Tucker, Carole; Ullom, Joel; Vagnozzi, Sunny; van Engelen, Alexander; Van Lanen, Jeff; Van Winkle, Daniel D.; Vavagiakis, Eve M.; Vergès, Clara; Vissers, Michael; Wagoner, Kasey; Walker, Samantha; Wang, Yuhan; Ward, Jon; Westbrook, Ben; Whitehorn, Nathan; Williams, Jason; Williams, Joel; Wollack, Edward; Xu, Zhilei; Yasini, Siavash; Young, Edward; Yu, Byeonghee; Yu, Cyndia; Zago, Fernando; Zannoni, Mario; Zhang, Hezi; Zheng, Kaiwen; Zhu, Ningfeng; Zonca, Andrea
Comments: Astro2020 Decadal Project Whitepaper. arXiv admin note: text overlap with arXiv:1808.07445
Submitted: 2019-07-16
The Simons Observatory (SO) is a ground-based cosmic microwave background (CMB) experiment sited on Cerro Toco in the Atacama Desert in Chile that promises to provide breakthrough discoveries in fundamental physics, cosmology, and astrophysics. Supported by the Simons Foundation, the Heising-Simons Foundation, and with contributions from collaborating institutions, SO will see first light in 2021 and start a five year survey in 2022. SO has 287 collaborators from 12 countries and 53 institutions, including 85 students and 90 postdocs. The SO experiment in its currently funded form ('SO-Nominal') consists of three 0.4 m Small Aperture Telescopes (SATs) and one 6 m Large Aperture Telescope (LAT). Optimized for minimizing systematic errors in polarization measurements at large angular scales, the SATs will perform a deep, degree-scale survey of 10% of the sky to search for the signature of primordial gravitational waves. The LAT will survey 40% of the sky with arc-minute resolution. These observations will measure (or limit) the sum of neutrino masses, search for light relics, measure the early behavior of Dark Energy, and refine our understanding of the intergalactic medium, clusters and the role of feedback in galaxy formation. With up to ten times the sensitivity and five times the angular resolution of the Planck satellite, and roughly an order of magnitude increase in mapping speed over currently operating ("Stage 3") experiments, SO will measure the CMB temperature and polarization fluctuations to exquisite precision in six frequency bands from 27 to 280 GHz. SO will rapidly advance CMB science while informing the design of future observatories such as CMB-S4.
[11]  oai:arXiv.org:1903.06760  [pdf] - 1850850
Testing general relativity with accretion onto compact objects
Comments: White paper submitted for Astro2020 Decadal Survey. 8 pages, 2 figures
Submitted: 2019-03-15
The X-ray emission of neutron stars and black holes presents a rich phenomenology that can lead us to a better understanding of their nature and to address more general physics questions: Does general relativity apply in the strong gravity regime? Is spacetime around black holes described by the Kerr metric? This white paper considers how we can investigate these questions by studying reverberation mapping and quasi-periodic oscillations in accreting systems with a combination of high-spectral and high-timing resolution. In the near future, we will be able to study compact objects in the X-rays in a new way: advancements in transition-edge sensors (TES) technology will allow for electron-volt-resolution spectroscopy combined with nanoseconds-precision timing.
[12]  oai:arXiv.org:1903.06777  [pdf] - 1853119
Exploring the physics of neutron stars with high-resolution, high-throughput X-ray spectroscopy
Comments: White paper submitted for Astro2020 Decadal Survey. 7 pages, 2 figures
Submitted: 2019-03-15
The advent of moderately high-resolution X-ray spectroscopy with Chandra and XMM promised to usher in a new age in the study of neutron stars: we thought we would study neutron stars like stars, with resolved absorption spectra revealing their surface chemical composition and physical conditions (e.g. surface gravity, pressure, temperature). Nature, however, did not cooperate in this endeavor, as observations of neutron stars have not revealed verified atomic absorption lines yet. In the near future, advancements in transition-edge sensors (TES) technology will allow for electron-volt-resolution spectroscopy combined with nanoseconds-precision timing. Combining these detectors with collector optics will also us to study neutron stars in much greater detail by achieving high-energy resolution with much larger collecting areas to uncover even weak spectral features over a wide range of the photon energies. Perhaps we will finally be able to study neutron stars like stars.
[13]  oai:arXiv.org:1808.07445  [pdf] - 1841339
The Simons Observatory: Science goals and forecasts
The Simons Observatory Collaboration; Ade, Peter; Aguirre, James; Ahmed, Zeeshan; Aiola, Simone; Ali, Aamir; Alonso, David; Alvarez, Marcelo A.; Arnold, Kam; Ashton, Peter; Austermann, Jason; Awan, Humna; Baccigalupi, Carlo; Baildon, Taylor; Barron, Darcy; Battaglia, Nick; Battye, Richard; Baxter, Eric; Bazarko, Andrew; Beall, James A.; Bean, Rachel; Beck, Dominic; Beckman, Shawn; Beringue, Benjamin; Bianchini, Federico; Boada, Steven; Boettger, David; Bond, J. Richard; Borrill, Julian; Brown, Michael L.; Bruno, Sarah Marie; Bryan, Sean; Calabrese, Erminia; Calafut, Victoria; Calisse, Paolo; Carron, Julien; Challinor, Anthony; Chesmore, Grace; Chinone, Yuji; Chluba, Jens; Cho, Hsiao-Mei Sherry; Choi, Steve; Coppi, Gabriele; Cothard, Nicholas F.; Coughlin, Kevin; Crichton, Devin; Crowley, Kevin D.; Crowley, Kevin T.; Cukierman, Ari; D'Ewart, John M.; Dünner, Rolando; de Haan, Tijmen; Devlin, Mark; Dicker, Simon; Didier, Joy; Dobbs, Matt; Dober, Bradley; Duell, Cody J.; Duff, Shannon; Duivenvoorden, Adri; Dunkley, Jo; Dusatko, John; Errard, Josquin; Fabbian, Giulio; Feeney, Stephen; Ferraro, Simone; Fluxà, Pedro; Freese, Katherine; Frisch, Josef C.; Frolov, Andrei; Fuller, George; Fuzia, Brittany; Galitzki, Nicholas; Gallardo, Patricio A.; Ghersi, Jose Tomas Galvez; Gao, Jiansong; Gawiser, Eric; Gerbino, Martina; Gluscevic, Vera; Goeckner-Wald, Neil; Golec, Joseph; Gordon, Sam; Gralla, Megan; Green, Daniel; Grigorian, Arpi; Groh, John; Groppi, Chris; Guan, Yilun; Gudmundsson, Jon E.; Han, Dongwon; Hargrave, Peter; Hasegawa, Masaya; Hasselfield, Matthew; Hattori, Makoto; Haynes, Victor; Hazumi, Masashi; He, Yizhou; Healy, Erin; Henderson, Shawn W.; Hervias-Caimapo, Carlos; Hill, Charles A.; Hill, J. Colin; Hilton, Gene; Hilton, Matt; Hincks, Adam D.; Hinshaw, Gary; Hložek, Renée; Ho, Shirley; Ho, Shuay-Pwu Patty; Howe, Logan; Huang, Zhiqi; Hubmayr, Johannes; Huffenberger, Kevin; Hughes, John P.; Ijjas, Anna; Ikape, Margaret; Irwin, Kent; Jaffe, Andrew H.; Jain, Bhuvnesh; Jeong, Oliver; Kaneko, Daisuke; Karpel, Ethan D.; Katayama, Nobuhiko; Keating, Brian; Kernasovskiy, Sarah S.; Keskitalo, Reijo; Kisner, Theodore; Kiuchi, Kenji; Klein, Jeff; Knowles, Kenda; Koopman, Brian; Kosowsky, Arthur; Krachmalnicoff, Nicoletta; Kuenstner, Stephen E.; Kuo, Chao-Lin; Kusaka, Akito; Lashner, Jacob; Lee, Adrian; Lee, Eunseong; Leon, David; Leung, Jason S. -Y.; Lewis, Antony; Li, Yaqiong; Li, Zack; Limon, Michele; Linder, Eric; Lopez-Caraballo, Carlos; Louis, Thibaut; Lowry, Lindsay; Lungu, Marius; Madhavacheril, Mathew; Mak, Daisy; Maldonado, Felipe; Mani, Hamdi; Mates, Ben; Matsuda, Frederick; Maurin, Loïc; Mauskopf, Phil; May, Andrew; McCallum, Nialh; McKenney, Chris; McMahon, Jeff; Meerburg, P. Daniel; Meyers, Joel; Miller, Amber; Mirmelstein, Mark; Moodley, Kavilan; Munchmeyer, Moritz; Munson, Charles; Naess, Sigurd; Nati, Federico; Navaroli, Martin; Newburgh, Laura; Nguyen, Ho Nam; Niemack, Michael; Nishino, Haruki; Orlowski-Scherer, John; Page, Lyman; Partridge, Bruce; Peloton, Julien; Perrotta, Francesca; Piccirillo, Lucio; Pisano, Giampaolo; Poletti, Davide; Puddu, Roberto; Puglisi, Giuseppe; Raum, Chris; Reichardt, Christian L.; Remazeilles, Mathieu; Rephaeli, Yoel; Riechers, Dominik; Rojas, Felipe; Roy, Anirban; Sadeh, Sharon; Sakurai, Yuki; Salatino, Maria; Rao, Mayuri Sathyanarayana; Schaan, Emmanuel; Schmittfull, Marcel; Sehgal, Neelima; Seibert, Joseph; Seljak, Uros; Sherwin, Blake; Shimon, Meir; Sierra, Carlos; Sievers, Jonathan; Sikhosana, Precious; Silva-Feaver, Maximiliano; Simon, Sara M.; Sinclair, Adrian; Siritanasak, Praween; Smith, Kendrick; Smith, Stephen R.; Spergel, David; Staggs, Suzanne T.; Stein, George; Stevens, Jason R.; Stompor, Radek; Suzuki, Aritoki; Tajima, Osamu; Takakura, Satoru; Teply, Grant; Thomas, Daniel B.; Thorne, Ben; Thornton, Robert; Trac, Hy; Tsai, Calvin; Tucker, Carole; Ullom, Joel; Vagnozzi, Sunny; van Engelen, Alexander; Van Lanen, Jeff; Van Winkle, Daniel D.; Vavagiakis, Eve M.; Vergès, Clara; Vissers, Michael; Wagoner, Kasey; Walker, Samantha; Ward, Jon; Westbrook, Ben; Whitehorn, Nathan; Williams, Jason; Williams, Joel; Wollack, Edward J.; Xu, Zhilei; Yu, Byeonghee; Yu, Cyndia; Zago, Fernando; Zhang, Hezi; Zhu, Ningfeng
Comments: This paper presents an overview of the Simons Observatory science goals, details about the instrument will be presented in a companion paper. The author contribution to this paper is available at https://simonsobservatory.org/publications.php (Abstract abridged) -- matching version published in JCAP
Submitted: 2018-08-22, last modified: 2019-03-01
The Simons Observatory (SO) is a new cosmic microwave background experiment being built on Cerro Toco in Chile, due to begin observations in the early 2020s. We describe the scientific goals of the experiment, motivate the design, and forecast its performance. SO will measure the temperature and polarization anisotropy of the cosmic microwave background in six frequency bands: 27, 39, 93, 145, 225 and 280 GHz. The initial configuration of SO will have three small-aperture 0.5-m telescopes (SATs) and one large-aperture 6-m telescope (LAT), with a total of 60,000 cryogenic bolometers. Our key science goals are to characterize the primordial perturbations, measure the number of relativistic species and the mass of neutrinos, test for deviations from a cosmological constant, improve our understanding of galaxy evolution, and constrain the duration of reionization. The SATs will target the largest angular scales observable from Chile, mapping ~10% of the sky to a white noise level of 2 $\mu$K-arcmin in combined 93 and 145 GHz bands, to measure the primordial tensor-to-scalar ratio, $r$, at a target level of $\sigma(r)=0.003$. The LAT will map ~40% of the sky at arcminute angular resolution to an expected white noise level of 6 $\mu$K-arcmin in combined 93 and 145 GHz bands, overlapping with the majority of the LSST sky region and partially with DESI. With up to an order of magnitude lower polarization noise than maps from the Planck satellite, the high-resolution sky maps will constrain cosmological parameters derived from the damping tail, gravitational lensing of the microwave background, the primordial bispectrum, and the thermal and kinematic Sunyaev-Zel'dovich effects, and will aid in delensing the large-angle polarization signal to measure the tensor-to-scalar ratio. The survey will also provide a legacy catalog of 16,000 galaxy clusters and more than 20,000 extragalactic sources.
[14]  oai:arXiv.org:1809.03689  [pdf] - 1748092
Highly-multiplexed microwave SQUID readout using the SLAC Microresonator Radio Frequency (SMuRF) Electronics for Future CMB and Sub-millimeter Surveys
Comments: 16 pages, 5 figures
Submitted: 2018-09-11
The next generation of cryogenic CMB and submillimeter cameras under development require densely instrumented sensor arrays to meet their science goals. The readout of large numbers ($\sim$10,000--100,000 per camera) of sub-Kelvin sensors, for instance as proposed for the CMB-S4 experiment, will require substantial improvements in cold and warm readout techniques. To reduce the readout cost per sensor and integration complexity, efforts are presently focused on achieving higher multiplexing density while maintaining readout noise subdominant to intrinsic detector noise. Highly-multiplexed cold readout technologies in active development include Microwave Kinetic Inductance Sensors (MKIDs) and microwave rf-SQUIDs. Both exploit the high quality factors of superconducting microwave resonators to densely channelize sub-Kelvin sensors into the bandwidth of a microwave transmission line. We present advancements in the development of a new warm readout system for microwave SQUID multiplexing, the SLAC Superconducting Microresonator RF electronics, or SMuRF. The SMuRF system is unique in its ability to track each tone, minimizing the total RF power required to read out each resonator, thereby significantly reducing the linearity requirements on the cold and warm readout. Here, we present measurements of the readout noise and linearity of the first full SMuRF system, including a demonstration of closed-loop tone tracking on a 528 channel cryogenic microwave SQUID multiplexer. SMuRF is being explored as a potential readout solution for several future CMB projects including Simons Observatory, BICEP Array, CCAT-prime, Ali-CPT, and CMB-S4. Parallel development of the platform is underway to adapt SMuRF to read out both MKID and fast X-ray TES calorimeter arrays.
[15]  oai:arXiv.org:1808.10491  [pdf] - 1746511
Studies of Systematic Uncertainties for Simons Observatory: Detector Array Effects
Comments: Proceeding from SPIE Astronomical Telescopes+Instrumentation 2018 (27 pages, 13 figures) v2: Added HEALPix reference
Submitted: 2018-08-30, last modified: 2018-09-06
In this proceeding, we present studies of instrumental systematic effects for the Simons Obsevatory (SO) that are associated with the detector system and its interaction with the full SO experimental systems. SO will measure the Cosmic Microwave Background (CMB) temperature and polarization anisotropies over a wide range of angular scales in six bands with bandcenters spanning from 27 GHz to 270 GHz. We explore effects including intensity-to-polarization leakage due to coupling optics, bolometer nonlinearity, uncalibrated gain variations of bolometers, and readout crosstalk. We model the level of signal contamination, discuss proposed mitigation schemes, and present instrument requirements to inform the design of SO and future CMB projects.
[16]  oai:arXiv.org:1808.10037  [pdf] - 1742126
Simons Observatory Large Aperture Telescope Receiver Design Overview
Comments:
Submitted: 2018-08-29
The Simons Observatory (SO) will make precision temperature and polarization measurements of the cosmic microwave background (CMB) using a series of telescopes which will cover angular scales between one arcminute and tens of degrees and sample frequencies between 27 and 270 GHz. Here we present the current design of the large aperture telescope receiver (LATR), a 2.4 m diameter cryostat that will be mounted on the SO 6 m telescope and will be the largest CMB receiver to date. The cryostat size was chosen to take advantage of the large focal plane area having high Strehl ratios, which is inherent to the Cross-Dragone telescope design. The LATR will be able to accommodate thirteen optics tubes, each having a 36 cm diameter aperture and illuminating several thousand transition-edge sensor (TES) bolometers. This set of equipment will provide an opportunity to make measurements with unparalleled sensitivity. However, the size and complexity of the LATR also pose numerous technical challenges. In the following paper, we present the design of the LATR and include how we address these challenges. The solutions we develop in the process of designing the LATR will be informative for the general CMB community, and for future CMB experiments like CMB-S4.
[17]  oai:arXiv.org:1808.08489  [pdf] - 1739192
Preflight Characterization of the BLAST-TNG Receiver and Detector Arrays
Comments: 15 pages, 7 figures, SPIE Astronomical Telescopes and Instrumentation Conference
Submitted: 2018-08-25
The Next Generation Balloon-borne Large Aperture Submillimeter Telescope (BLAST-TNG) is a submillimeter mapping experiment planned for a 28 day long-duration balloon (LDB) flight from McMurdo Station, Antarctica during the 2018-2019 season. BLAST-TNG will detect submillimeter polarized interstellar dust emission, tracing magnetic fields in galactic molecular clouds. BLAST-TNG will be the first polarimeter with the sensitivity and resolution to probe the $\sim$0.1 parsec-scale features that are critical to understanding the origin of structures in the interstellar medium. BLAST-TNG features three detector arrays operating at wavelengths of 250, 350, and 500 $\mu$m (1200, 857, and 600 GHz) comprised of 918, 469, and 272 dual-polarization pixels, respectively. Each pixel is made up of two crossed microwave kinetic inductance detectors (MKIDs). These arrays are cooled to 275 mK in a cryogenic receiver. Each MKID has a different resonant frequency, allowing hundreds of resonators to be read out on a single transmission line. This inherent ability to be frequency-domain multiplexed simplifies the cryogenic readout hardware, but requires careful optical testing to map out the physical location of each resonator on the focal plane. Receiver-level optical testing was carried out using both a cryogenic source mounted to a movable xy-stage with a shutter, and a beam-filling, heated blackbody source able to provide a 10-50 $^\circ$C temperature chop. The focal plane array noise properties, responsivity, polarization efficiency, instrumental polarization were measured. We present the preflight characterization of the BLAST-TNG cryogenic system and array-level optical testing of the MKID detector arrays in the flight receiver.
[18]  oai:arXiv.org:1808.04493  [pdf] - 1935462
The Simons Observatory: Instrument Overview
Comments:
Submitted: 2018-08-13
The Simons Observatory (SO) will make precise temperature and polarization measurements of the cosmic microwave background (CMB) using a set of telescopes which will cover angular scales between 1 arcminute and tens of degrees, contain over 60,000 detectors, and observe at frequencies between 27 and 270 GHz. SO will consist of a 6 m aperture telescope coupled to over 30,000 transition-edge sensor bolometers along with three 42 cm aperture refractive telescopes, coupled to an additional 30,000+ detectors, all of which will be located in the Atacama Desert at an altitude of 5190 m. The powerful combination of large and small apertures in a CMB observatory will allow us to sample a wide range of angular scales over a common survey area. SO will measure fundamental cosmological parameters of our universe, constrain primordial fluctuations, find high redshift clusters via the Sunyaev-Zel`dovich effect, constrain properties of neutrinos, and trace the density and velocity of the matter in the universe over cosmic time. The complex set of technical and science requirements for this experiment has led to innovative instrumentation solutions which we will discuss. The large aperture telescope will couple to a cryogenic receiver that is 2.4 m in diameter and nearly 3 m long, creating a number of technical challenges. Concurrently, we are designing the array of cryogenic receivers housing the 42 cm aperture telescopes. We will discuss the sensor technology SO will use and we will give an overview of the drivers for and designs of the SO telescopes and receivers, with their cold optical components and detector arrays.
[19]  oai:arXiv.org:1807.07496  [pdf] - 1732805
Advanced ACTPol TES Device Parameters and Noise Performance in Fielded Arrays
Comments: Accepted for publication in Journal of Low Temperature Physics for LTD-17 special issue
Submitted: 2018-07-19
The Advanced ACTPol (AdvACT) upgrade to the Atacama Cosmology Telescope (ACT) features arrays of aluminum manganese transition-edge sensors (TESes) optimized for ground-based observations of the Cosmic Microwave Background (CMB). Array testing shows highly responsive detectors with anticipated in-band noise performance under optical loading. We report on TES parameters measured with impedance data taken on a subset of TESes. We then compare modeled noise spectral densities to measurements. We find excess noise at frequencies around 100 Hz, nearly outside of the signal band of CMB measurements. In addition, we describe full-array noise measurements in the laboratory and in the field for two new AdvACT mid-frequency arrays, sensitive at bands centered on 90 and 150 GHz, and data for the high-frequency array (150/230 GHz) as deployed.
[20]  oai:arXiv.org:1807.01384  [pdf] - 1740023
Low Temperature Detectors for CMB Imaging Arrays
Comments: Proceedings for the 17th international workshop on Low Temperature Detectors (LTD17)
Submitted: 2018-07-03
We review advances in low temperature detector (LTD) arrays for Cosmic Microwave Background (CMB) polarization experiments, with a particular emphasis on imaging arrays. We briefly motivate the science case, which has spurred a large number of independent experimental efforts. We describe the challenges associated with CMB polarization measurements and how these challenges impact LTD design. Key aspects of an ideal CMB polarization imaging array are developed and compared to the current state-of-the-art. These aspects include dual-polarization-sensitivity, background-limited detection over a 10:1 bandwidth ratio, and frequency independent angular responses. Although existing technology lacks all of this capability, today's CMB imaging arrays achieve many of these ideals and are highly advanced superconducting integrated circuits. Deployed arrays map the sky with pixels that contain elements for beam formation, polarization diplexing, passband definition in multiple frequency channels, and bolometric sensing. Several detector architectures are presented. We comment on the implementation of both transition-edge-sensor bolometers and microwave kinetic inductance detectors for CMB applications. Lastly, we discuss fabrication capability in the context of next-generation instruments that call for $\sim 10^6$ sensors.
[21]  oai:arXiv.org:1807.00058  [pdf] - 1839608
Prime-Cam: A first-light instrument for the CCAT-prime telescope
Comments: Presented at SPIE Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy IX, June 15th, 2018
Submitted: 2018-06-29
CCAT-prime will be a 6-meter aperture telescope operating from sub-mm to mm wavelengths, located at 5600 meters elevation on Cerro Chajnantor in the Atacama Desert in Chile. Its novel crossed-Dragone optical design will deliver a high throughput, wide field of view capable of illuminating much larger arrays of sub-mm and mm detectors than can existing telescopes. We present an overview of the motivation and design of Prime-Cam, a first-light instrument for CCAT-prime. Prime-Cam will house seven instrument modules in a 1.8 meter diameter cryostat, cooled by a dilution refrigerator. The optical elements will consist of silicon lenses, and the instrument modules can be individually optimized for particular science goals. The current design enables both broadband, dual-polarization measurements and narrow-band, Fabry-Perot spectroscopic imaging using multichroic transition-edge sensor (TES) bolometers operating between 190 and 450 GHz. It also includes broadband kinetic induction detectors (KIDs) operating at 860 GHz. This wide range of frequencies will allow excellent characterization and removal of galactic foregrounds, which will enable precision measurements of the sub-mm and mm sky. Prime-Cam will be used to constrain cosmology via the Sunyaev-Zeldovich effects, map the intensity of [CII] 158 $\mu$m emission from the Epoch of Reionization, measure Cosmic Microwave Background polarization and foregrounds, and characterize the star formation history over a wide range of redshifts. More information about CCAT-prime can be found at www.ccatobservatory.org.
[22]  oai:arXiv.org:1711.04841  [pdf] - 1704298
Characterization of the Mid-Frequency Arrays for Advanced ACTPol
Comments: Version accepted for publication by Journal of Low Temperature Physics
Submitted: 2017-11-13, last modified: 2018-06-25
The Advanced ACTPol upgrade on the Atacama Cosmology Telescope aims to improve the measurement of the cosmic microwave background anisotropies and polarization, using four new dichroic detector arrays fabricated on 150-mm silicon wafers. These bolometric cameras use AlMn transition-edge sensors, coupled to feedhorns with orthomode transducers for polarization sensitivity. The first deployed camera is sensitive to both 150 GHz and 230 GHz. Here we present the lab characterization of the thermal parameters and optical efficiencies for the two newest fielded arrays, each sensitive to both 90 GHz and 150 GHz. We provide assessments of the parameter uniformity across each array with evaluation of systematic uncertainties. Lastly, we show the arrays' initial performance in the field.
[23]  oai:arXiv.org:1806.04316  [pdf] - 1737925
BoloCalc: a sensitivity calculator for the design of Simons Observatory
Comments: Submitted to the Proceedings of SPIE: Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy IX
Submitted: 2018-06-11
The Simons Observatory (SO) is an upcoming experiment that will study temperature and polarization fluctuations in the cosmic microwave background (CMB) from the Atacama Desert in Chile. SO will field both a large aperture telescope (LAT) and an array of small aperture telescopes (SATs) that will observe in six bands with center frequencies spanning from 27 to 270~GHz. Key considerations during the SO design phase are vast, including the number of cameras per telescope, focal plane magnification and pixel density, in-band optical power and camera throughput, detector parameter tolerances, and scan strategy optimization. To inform the SO design in a rapid, organized, and traceable manner, we have created a Python-based sensitivity calculator with several state-of-the-art features, including detector-to-detector optical white-noise correlations, a handling of simulated and measured bandpasses, and propagation of low-level parameter uncertainties to uncertainty in on-sky noise performance. We discuss the mathematics of the sensitivity calculation, the calculator's object-oriented structure and key features, how it has informed the design of SO, and how it can enhance instrument design in the broader CMB community, particularly for CMB-S4.
[24]  oai:arXiv.org:1805.08363  [pdf] - 1709494
SLAC Microresonator Radio Frequency (SMuRF) Electronics for Read Out of Frequency-Division-Multiplexed Cryogenic Sensors
Comments: 7 pages, 5 figures, Submitted to the Journal of Low Temperature Physics (Proceedings of the 17th International Workshop on Low Temperature Detectors)
Submitted: 2018-05-21
Large arrays of cryogenic sensors for various imaging applications ranging across x-ray, gamma-ray, Cosmic Microwave Background (CMB), mm/sub-mm, as well as particle detection increasingly rely on superconducting microresonators for high multiplexing factors. These microresonators take the form of microwave SQUIDs that couple to Transition-Edge Sensors (TES) or Microwave Kinetic Inductance Detectors (MKIDs). In principle, such arrays can be read out with vastly scalable software-defined radio using suitable FPGAs, ADCs and DACs. In this work, we share plans and show initial results for SLAC Microresonator Radio Frequency (SMuRF) electronics, a next-generation control and readout system for superconducting microresonators. SMuRF electronics are unique in their implementation of specialized algorithms for closed-loop tone tracking, which consists of fast feedback and feedforward to each resonator's excitation parameters based on transmission measurements. Closed-loop tone tracking enables improved system linearity, a significant increase in sensor count per readout line, and the possibility of overcoupled resonator designs for enhanced dynamic range. Low-bandwidth prototype electronics were used to demonstrate closed-loop tone tracking on twelve 300-kHz-wide microwave SQUID resonators, spaced at $\sim$6 MHz with center frequencies $\sim$5-6 GHz. We achieve multi-kHz tracking bandwidth and demonstrate that the noise floor of the electronics is subdominant to the noise intrinsic in the multiplexer.
[25]  oai:arXiv.org:1803.03280  [pdf] - 1698088
Millimeter-Wave Polarimeters Using Kinetic Inductance Detectors for TolTEC and Beyond
Comments: 7 pages, 4 figures, 1 table. Submitted to Journal of Low Temperature Physics
Submitted: 2018-03-08
Microwave Kinetic Inductance Detectors (MKIDs) provide a compelling path forward to the large-format polarimeter, imaging, and spectrometer arrays needed for next-generation experiments in millimeter-wave cosmology and astronomy. We describe the development of feedhorn-coupled MKID detectors for the TolTEC millimeter-wave imaging polarimeter being constructed for the 50-meter Large Millimeter Telescope (LMT). Observations with TolTEC are planned to begin in early 2019. TolTEC will comprise $\sim$7,000 polarization sensitive MKIDs and will represent the first MKID arrays fabricated and deployed on monolithic 150 mm diameter silicon wafers -- a critical step towards future large-scale experiments with over $10^5$ detectors. TolTEC will operate in observational bands at 1.1, 1.4, and 2.0 mm and will use dichroic filters to define a physically independent focal plane for each passband, thus allowing the polarimeters to use simple, direct-absorption inductive structures that are impedance matched to incident radiation. This work is part of a larger program at NIST-Boulder to develop MKID-based detector technologies for use over a wide range of photon energies spanning millimeter-waves to X-rays. We present the detailed pixel layout and describe the methods, tools, and flexible design parameters that allow this solution to be optimized for use anywhere in the millimeter and sub-millimeter bands. We also present measurements of prototype devices operating in the 1.1 mm band and compare the observed optical performance to that predicted from models and simulations.
[26]  oai:arXiv.org:1710.04326  [pdf] - 1604980
Microwave SQUID Multiplexer demonstration for Cosmic Microwave Background Imagers
Comments: 6 pages, 4 figures
Submitted: 2017-10-11, last modified: 2017-12-15
Key performance characteristics are demonstrated for the microwave SQUID multiplexer ($\mu$MUX) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the $\mu$MUX produces a white, input referred current noise level of 29~pA$/\sqrt{\mathrm{Hz}}$ at -77~dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure 98~pA$/\sqrt{\mathrm{Hz}}$ in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e., phonon) noise. Furthermore, the power spectral density exhibits a white spectrum at low frequencies ($\sim$~100~mHz), which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the $\mu$MUX as a viable readout technique for future CMB imaging instruments.
[27]  oai:arXiv.org:1711.04169  [pdf] - 1755845
280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2 Suborbital Polarimeter
Comments:
Submitted: 2017-11-11, last modified: 2017-11-22
We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated silicon feedhorns coupled to an array of aluminum-manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1,530 polarization sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be ~3 pW at 300 mK with a less than 6% variation across each array at one standard deviation. These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.
[28]  oai:arXiv.org:1611.07856  [pdf] - 1532790
When "Optimal Filtering" Isn't
Comments: Submitted to the Proceedings of the 2016 Applied Superconductivity Conference
Submitted: 2016-11-23
The so-called "optimal filter" analysis of a microcalorimeter's x-ray pulses is statistically optimal only if all pulses have the same shape, regardless of energy. The shapes of pulses from a nonlinear detector can and do depend on the pulse energy, however. A pulse-fitting procedure that we call "tangent filtering" accounts for the energy dependence of the shape and should therefore achieve superior energy resolution. We take a geometric view of the pulse-fitting problem and give expressions to predict how much the energy resolution stands to benefit from such a procedure. We also demonstrate the method with a case study of K-line fluorescence from several 3d transition metals. The method improves the resolution from 4.9 eV to 4.2 eV at the Cu K$\alpha$ line (8.0keV).
[29]  oai:arXiv.org:1607.05754  [pdf] - 1531066
Mechanical design and development of TES bolometer detector arrays for the Advanced ACTPol experiment
Comments: 9 pages, 5 figures, SPIE Astronomical Telescopes and Instrumentation conference proceedings
Submitted: 2016-07-19
The next generation Advanced ACTPol (AdvACT) experiment is currently underway and will consist of four Transition Edge Sensor (TES) bolometer arrays, with three operating together, totaling ~5800 detectors on the sky. Building on experience gained with the ACTPol detector arrays, AdvACT will utilize various new technologies, including 150mm detector wafers equipped with multichroic pixels, allowing for a more densely packed focal plane. Each set of detectors includes a feedhorn array of stacked silicon wafers which form a spline profile leading to each pixel. This is then followed by a waveguide interface plate, detector wafer, back short cavity plate, and backshort cap. Each array is housed in a custom designed structure manufactured from high purity copper and then gold plated. In addition to the detector array assembly, the array package also encloses cryogenic readout electronics. We present the full mechanical design of the AdvACT high frequency (HF) detector array package along with a detailed look at the detector array stack assemblies. This experiment will also make use of extensive hardware and software previously developed for ACT, which will be modified to incorporate the new AdvACT instruments. Therefore, we discuss the integration of all AdvACT arrays with pre-existing ACTPol infrastructure.
[30]  oai:arXiv.org:1606.09396  [pdf] - 1530923
Design of 280 GHz feedhorn-coupled TES arrays for the balloon-borne polarimeter SPIDER
Comments: Proceedings of SPIE Astronomical Telescopes + Instrumentation 2016
Submitted: 2016-06-30, last modified: 2016-07-07
We describe 280 GHz bolometric detector arrays that instrument the balloon-borne polarimeter SPIDER. A primary science goal of SPIDER is to measure the large-scale B-mode polarization of the cosmic microwave background in search of the cosmic-inflation, gravitational-wave signature. 280 GHz channels aid this science goal by constraining the level of B-mode contamination from galactic dust emission. We present the focal plane unit design, which consists of a 16$\times$16 array of conical, corrugated feedhorns coupled to a monolithic detector array fabricated on a 150 mm diameter silicon wafer. Detector arrays are capable of polarimetric sensing via waveguide probe-coupling to a multiplexed array of transition-edge-sensor (TES) bolometers. The SPIDER receiver has three focal plane units at 280 GHz, which in total contains 765 spatial pixels and 1,530 polarization sensitive bolometers. By fabrication and measurement of single feedhorns, we demonstrate 14.7$^{\circ}$ FHWM Gaussian-shaped beams with $<$1% ellipticity in a 30% fractional bandwidth centered at 280 GHz. We present electromagnetic simulations of the detection circuit, which show 94% band-averaged, single-polarization coupling efficiency, 3% reflection and 3% radiative loss. Lastly, we demonstrate a low thermal conductance bolometer, which is well-described by a simple TES model and exhibits an electrical noise equivalent power (NEP) = 2.6 $\times$ 10$^{-17}$ W/$\sqrt{\mathrm{Hz}}$, consistent with the phonon noise prediction.
[31]  oai:arXiv.org:1503.05989  [pdf] - 1530243
Microcalorimeter Spectroscopy at High Pulse Rates: a Multi-Pulse Fitting Technique
Comments: This version exactly matches the submission to journal
Submitted: 2015-03-20, last modified: 2015-03-31
Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each sensor must be able to measure hundreds or even thousands of photon energies per second. Current "optimal filtering" approaches to achieve the best possible energy resolution work only for photons well isolated in time, a requirement in direct conflict with the need for high-rate measurements. We describe a new analysis procedure to allow fitting for the pulse height of all photons even in the presence of heavy pulse pile-up. In the limit of isolated pulses, the technique reduces to the standard optimal filtering with long records. We employ reasonable approximations to the noise covariance function in order to render multi-pulse fitting computationally viable even for very long data records. The technique is employed to analyze x-ray emission spectra at 600 eV and 6 keV at rates up to 250 counts per second in microcalorimeters having exponential signal decay times of approximately 1.2 ms.
[32]  oai:arXiv.org:1409.7084  [pdf] - 896558
The Next Generation BLAST Experiment
Comments:
Submitted: 2014-09-24, last modified: 2014-11-12
The Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry (BLASTPol) was a suborbital experiment designed to map magnetic fields in order to study their role in star formation processes. BLASTPol made detailed polarization maps of a number of molecular clouds during its successful flights from Antarctica in 2010 and 2012. We present the next-generation BLASTPol instrument (BLAST-TNG) that will build off the success of the previous experiment and continue its role as a unique instrument and a test bed for new technologies. With a 16-fold increase in mapping speed, BLAST-TNG will make larger and deeper maps. Major improvements include a 2.5 m carbon fiber mirror that is 40% wider than the BLASTPol mirror and ~3000 polarization sensitive detectors. BLAST-TNG will observe in three bands at 250, 350, and 500 microns. The telescope will serve as a pathfinder project for microwave kinetic inductance detector (MKID) technology, as applied to feedhorn coupled submillimeter detector arrays. The liquid helium cooled cryostat will have a 28-day hold time and will utilize a closed-cycle $^3$He refrigerator to cool the detector arrays to 270 mK. This will enable a detailed mapping of more targets with higher polarization resolution than any other submillimeter experiment to date. BLAST-TNG will also be the first balloon-borne telescope to offer shared risk observing time to the community. This paper outlines the motivation for the project and the instrumental design.
[33]  oai:arXiv.org:1407.3756  [pdf] - 1215656
The next-generation BLASTPol experiment
Comments: 12 pages, 6 figures. Presented at SPIE Ground-based and Airborne Telescopes V, June 23, 2014. To be published in Proceedings of SPIE Volume 9145
Submitted: 2014-07-14
The Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry (BLASTPol) is a suborbital mapping experiment designed to study the role magnetic fields play in star formation. BLASTPol has had two science flights from McMurdo Station, Antarctica in 2010 and 2012. These flights have produced thousands of polarization vectors at 250, 350 and 500 microns in several molecular cloud targets. We present the design, specifications, and progress towards the next-generation BLASTPol experiment (BLAST-TNG). BLAST-TNG will fly a 40% larger diameter primary mirror, with almost 8 times the number of polarization-sensitive detectors resulting in a factor of 16 increase in mapping speed. With a spatial resolution of 22 arcseconds and four times the field of view of BLASTPol, BLAST-TNG will bridge the angular scales between Planck's low resolution all-sky maps and ALMA's ultra-high resolution narrow fields. The new receiver has a larger cryogenics volume, allowing for a 28 day hold time. BLAST-TNG employs three arrays of Microwave Kinetic Inductance Detectors (MKIDs) with 30% fractional bandwidth at 250, 350 and 500 microns. In this paper, we will present the new BLAST-TNG instrument and science objectives.
[34]  oai:arXiv.org:1310.7287  [pdf] - 1180273
High-resolution gamma-ray spectroscopy with a microwave-multiplexed transition-edge sensor array
Comments: 5 pages, 5 figures, to be published in Applied Physics Letters, Vol 103, Issue 20, on 11-Nov-2013
Submitted: 2013-10-27
We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/$\sqrt{\text{Hz}}$ at the TES. The readout circuit consists of superconducting microwave resonators coupled to radio-frequency superconducting-quantum-interference-devices (SQUID) and transduces changes in input current to changes in phase of a microwave signal. We use flux-ramp modulation to linearize the response and evade low-frequency noise. This demonstration establishes one path for the readout of cryogenic X-ray and gamma-ray sensor arrays with more than $10^3$ elements and spectral resolving powers $R=\lambda/\Delta\lambda > 10^3$.
[35]  oai:arXiv.org:1301.3650  [pdf] - 832812
SCUBA-2: The 10000 pixel bolometer camera on the James Clerk Maxwell Telescope
Comments: 23 pages, 20 figures, 3 tables. Accepted by MNRAS
Submitted: 2013-01-16
SCUBA-2 is an innovative 10000 pixel bolometer camera operating at submillimetre wavelengths on the James Clerk Maxwell Telescope (JCMT). The camera has the capability to carry out wide-field surveys to unprecedented depths, addressing key questions relating to the origins of galaxies, stars and planets. With two imaging arrays working simultaneously in the atmospheric windows at 450 and 850 microns, the vast increase in pixel count means that SCUBA-2 maps the sky 100-150 times faster than the previous SCUBA instrument. In this paper we present an overview of the instrument, discuss the physical characteristics of the superconducting detector arrays, outline the observing modes and data acquisition, and present the early performance figures on the telescope. We also showcase the capabilities of the instrument via some early examples of the science SCUBA-2 has already undertaken. In February 2012, SCUBA-2 began a series of unique legacy surveys for the JCMT community. These surveys will take 2.5 years and the results are already providing complementary data to the shorter wavelength, shallower, larger-area surveys from Herschel. The SCUBA-2 surveys will also provide a wealth of information for further study with new facilities such as ALMA, and future telescopes such as CCAT and SPICA.
[36]  oai:arXiv.org:1212.1738  [pdf] - 600827
Filters for High Rate Pulse Processing
Comments: 5 pages, 6 figures, 1 table
Submitted: 2012-12-07
We introduce a filter-construction method for pulse processing that differs in two respects from that in standard optimal filtering, in which the average pulse shape and noise-power spectral density are combined to create a convolution filter for estimating pulse heights. First, the proposed filters are computed in the time domain, to avoid periodicity artifacts of the discrete Fourier transform, and second, orthogonality constraints are imposed on the filters, to reduce the filtering procedure's sensitivity to unknown baseline height and pulse tails. We analyze the proposed filters, predicting energy resolution under several scenarios, and apply the filters to high-rate pulse data from gamma-rays measured by a transition-edge-sensor microcalorimeter.
[37]  oai:arXiv.org:1201.6289  [pdf] - 476260
Code-division multiplexing for x-ray microcalorimeters
Comments: To be published in Applied Physics Letters
Submitted: 2012-01-30
We demonstrate the code-division multiplexed (CDM) readout of eight transition-edge sensor microcalorimeters. The energy resolution is 3.0 eV (full width at half-maximum) or better at 5.9 keV, with a best resolution of 2.3 eV and a mean of 2.6 eV over the seven modulated detectors. The flux-summing CDM system is described and compared with similar time-division multiplexed (TDM) readout. We show that the sqrt(Npixels) multiplexing disadvantage associated with TDM is not present in CDM. This demonstration establishes CDM as both a simple route to higher performance in existing TDM microcalorimetric experiments and a long-term approach to reaching higher multiplexing factors.
[38]  oai:arXiv.org:1110.2531  [pdf] - 507871
Optimization and analysis of code-division multiplexed TES microcalorimeters
Comments: 7 pages, 5 figures. Presented at the 14th International Workshop on Low Temperature Detectors, Heidelberg University, August 1-5, 2011, proceedings to be published in the Journal of Low Temperature Physics
Submitted: 2011-10-11
We are developing code-division multiplexing (CDM) systems for transition-edge sensor arrays with the goal of reaching multiplexing factors in the hundreds. We report on x-ray measurements made with a four-channel prototype CDM system that employs a flux-summing architecture, emphasizing data-analysis issues. We describe an empirical method to determine the demodulation matrix that minimizes cross-talk. This CDM system achieves energy resolutions of between 2.3 eV and 3.0 eV FWHM at 5.9 keV.
[39]  oai:arXiv.org:1110.1608  [pdf] - 506520
Advanced code-division multiplexers for superconducting detector arrays
Comments: 8 pages, 3 figures, presented at the 14th International Workshop on Low Temperature Detectors, Heidelberg University, August 1-5, 2011, proceedings to be published in the Journal of Low Temperature Physics
Submitted: 2011-10-07
Multiplexers based on the modulation of superconducting quantum interference devices are now regularly used in multi-kilopixel arrays of superconducting detectors for astrophysics, cosmology, and materials analysis. Over the next decade, much larger arrays will be needed. These larger arrays require new modulation techniques and compact multiplexer elements that fit within each pixel. We present a new in-focal-plane code-division multiplexer that provides multiplexing elements with the required scalability. This code-division multiplexer uses compact lithographic modulation elements that simultaneously multiplex both signal outputs and superconducting transition-edge sensor (TES) detector bias voltages. It eliminates the shunt resistor used to voltage bias TES detectors, greatly reduces power dissipation, allows different dc bias voltages for each TES, and makes all elements sufficiently compact to fit inside the detector pixel area. These in-focal-plane code-division multiplexers can be combined with multi-gigahertz readout based on superconducting microresonators to scale to even larger arrays.
[40]  oai:arXiv.org:1104.2048  [pdf] - 576598
ORIGIN: Metal Creation and Evolution from the Cosmic Dawn
Herder, J. W. den; Piro, L.; Ohashi, T.; Kouveliotou, C.; Hartmann, D. H.; Kaastra, J. S.; Amati, L.; Andersen, M. I.; Arnaud, M.; Attéia, J-L.; Bandler, S.; Barbera, M.; Barcons, X.; Barthelmy, S.; Basa, S.; Basso, S.; Boer, M.; Branchini, E.; Branduardi-Raymont, G.; Borgani, S.; Boyarsky, A.; Brunetti, G.; Budtz-Jorgensen, C.; Burrows, D.; Butler, N.; Campana, S.; Caroli, E.; Ceballos, M.; Christensen, F.; Churazov, E.; Comastri, A.; Colasanti, L.; Cole, R.; Content, R.; Corsi, A.; Costantini, E.; Conconi, P.; Cusumano, G.; de Plaa, J.; De Rosa, A.; Del Santo, M.; Di Cosimo, S.; De Pasquale, M.; Doriese, R.; Ettori, S.; Evans, P.; Ezoe, Y.; Ferrari, L.; Finger, H.; Figueroa-Feliciano, T.; Friedrich, P.; Fujimoto, R.; Furuzawa, A.; Fynbo, J.; Gatti, F.; Galeazzi, M.; Gehrels, N.; Gendre, B.; Ghirlanda, G.; Ghisellini, G.; Gilfanov, M.; Giommi, P.; Girardi, M.; Grindlay, J.; Cocchi, M.; Godet, O.; Guedel, M.; Haardt, F.; Hartog, R. den; Hepburn, I.; Hermsen, W.; Hjorth, J.; Hoekstra, H.; Holland, A.; Hornstrup, A.; van der Horst, A.; Hoshino, A.; Zand, J. in 't; Irwin, K.; Ishisaki, Y.; Jonker, P.; Kitayama, T.; Kawahara, H.; Kawai, N.; Kelley, R.; Kilbourne, C.; de Korte, P.; Kusenko, A.; Kuvvetli, I.; Labanti, M.; Macculi, C.; Maiolino, R.; Hesse, M. Mas; Matsushita, K.; Mazzotta, P.; McCammon, D.; Méndez, M.; Mignani, R.; Mineo, T.; Mitsuda, K.; Mushotzky, R.; Molendi, S.; Moscardini, L.; Natalucci, L.; Nicastro, F.; O'Brien, P.; Osborne, J.; Paerels, F.; Page, M.; Paltani, S.; Pedersen, K.; Perinati, E.; Ponman, T.; Pointecouteau, E.; Predehl, P.; Porter, S.; Rasmussen, A.; Rauw, G.; Röttgering, H.; Roncarelli, M.; Rosati, P.; Quadrini, E.; Ruchayskiy, O.; Salvaterra, R.; Sasaki, S.; Sato, K.; Savaglio, S.; Schaye, J.; Sciortino, S.; Shaposhnikov, M.; Sharples, R.; Shinozaki, K.; Spiga, D.; Sunyaev, R.; Suto, Y.; Takei, Y.; Tanvir, N.; Tashiro, M.; Tamura, T.; Tawara, Y.; Troja, E.; Tsujimoto, M.; Tsuru, T.; Ubertini, P.; Ullom, J.; Ursino, E.; Verbunt, F.; van de Voort, F.; Viel, M.; Wachter, S.; Watson, D.; Weisskopf, M.; Werner, N.; White, N.; Willingale, R.; Wijers, R.; Yamasaki, N.; Yoshikawa, K.; Zane, S.
Comments: 34 pages, 13 figures. ESA Cosmic Vision medium-class mission (M3) proposal. Accepted for publication in Experimental Astronomy. Including minor corrections in the author list
Submitted: 2011-04-11, last modified: 2011-04-15
ORIGIN is a proposal for the M3 mission call of ESA aimed at the study of metal creation from the epoch of cosmic dawn. Using high-spectral resolution in the soft X-ray band, ORIGIN will be able to identify the physical conditions of all abundant elements between C and Ni to red-shifts of z=10, and beyond. The mission will answer questions such as: When were the first metals created? How does the cosmic metal content evolve? Where do most of the metals reside in the Universe? What is the role of metals in structure formation and evolution? To reach out to the early Universe ORIGIN will use Gamma-Ray Bursts (GRBs) to study their local environments in their host galaxies. This requires the capability to slew the satellite in less than a minute to the GRB location. By studying the chemical composition and properties of clusters of galaxies we can extend the range of exploration to lower redshifts (z ~ 0.2). For this task we need a high-resolution spectral imaging instrument with a large field of view. Using the same instrument, we can also study the so far only partially detected baryons in the Warm-Hot Intergalactic Medium (WHIM). The less dense part of the WHIM will be studied using absorption lines at low redshift in the spectra for GRBs.
[41]  oai:arXiv.org:astro-ph/0108055  [pdf] - 44031
X-ray Desorption of Molecules from Grains in Protoplanetary Disks
Comments: 27 pages, 5 figures, accepted by the Astrophysical Journal
Submitted: 2001-08-03
We examine the ability of stellar X-rays to desorb molecules from grains in outer protoplanetary disks. In particular, we consider the possibility of spot heating by X-rays and examine its effectiveness, compared to whole grain heating by X-rays, in sustaining a gas phase abundance of CO. As found in previous studies, whole grain heating is effective only for small grains (< 500 A). As a result, large grains are a permanent sink of CO and whole grain heating cannot sustain an equilibrium gas phase abundance of CO. Spot heating, in which the incident X-ray deposits energy in only a restricted region of the grain volume and which may occur as a consequence of the aggregate nature of grains, proves to be more promising. Assuming that grains are comprised of many thermal subunits that are poorly connected thermally, we find that spot heating is efficient at all grain sizes if large grains are effectively ``coated'' with small grains < 100 A in size. We discuss the implications of X-ray spot heating for the interpretation of millimeter emission line studies of outer protoplanetary disks.