Normalized to: Ulamec, S.
[1]
oai:arXiv.org:1908.07731 [pdf] - 2066926
GAUSS -- A Sample Return Mission to Ceres
Shi, Xian;
Castillo-Rogez, Julie;
Hsieh, Henry;
Hui, Hejiu;
Ip, Wing-Huen;
Lei, Hanlun;
Li, Jian-Yang;
Tosi, Federico;
Zhou, Liyong;
Agarwal, Jessica;
Barucci, Antonella;
Beck, Pierre;
Bagatin, Adriano Campo;
Capaccioni, Fabrizio;
Coates, Andrew;
Cremonese, Gabriele;
Duffard, Rene;
Jaumann, Ralf;
Jones, Geraint;
Grande, Manuel;
Kallio, Esa;
Lin, Yangting;
Mousis, Olivier;
Nathues, Andreas;
Oberst, Jürgen;
Showman, Adam;
Sierks, Holger;
Ulamec, Stephan;
Wang, Mingyuan
Submitted: 2019-08-21, last modified: 2020-03-19
The goal of Project GAUSS is to return samples from the dwarf planet Ceres.
Ceres is the most accessible ocean world candidate and the largest reservoir of
water in the inner solar system. It shows active cryovolcanism and hydrothermal
activities in recent history that resulted in minerals not found in any other
planets to date except for Earth's upper crust. The possible occurrence of
recent subsurface ocean on Ceres and the complex geochemistry suggest possible
past habitability and even the potential for ongoing habitability. Aiming to
answer a broad spectrum of questions about the origin and evolution of Ceres
and its potential habitability, GAUSS will return samples from this possible
ocean world for the first time. The project will address the following
top-level scientific questions: 1) What is the origin of Ceres and the origin
and transfer of water and other volatiles in the inner solar system? 2) What
are the physical properties and internal structure of Ceres? What do they tell
us about the evolutionary and aqueous alteration history of icy dwarf planets?
3) What are the astrobiological implications of Ceres? Was it habitable in the
past and is it still today? 4) What are the mineralogical connections between
Ceres and our current collections of primitive meteorites? GAUSS will first
perform a high-resolution global remote sensing investigation, characterizing
the geophysical and geochemical properties of Ceres. Candidate sampling sites
will then be identified, and observation campaigns will be run for an in-depth
assessment of the candidate sites. Once the sampling site is selected, a lander
will be deployed on the surface to collect samples and return them to Earth in
cryogenic conditions that preserves the volatile and organic composition as
well as the original physical status as much as possible.
[2]
oai:arXiv.org:1907.11081 [pdf] - 1923103
AMBITION -- Comet Nucleus Cryogenic Sample Return (White paper for ESA's
Voyage 2050 programme)
Bockelée-Morvan, D.;
Filacchione, G.;
Altwegg, K.;
Bianchi, E.;
Bizzarro, M.;
Blum, J.;
Bonal, L.;
Capaccioni, F.;
Codella, C.;
Choukroun, M.;
Cottin, H.;
Davidsson, B.;
De Sanctis, M. C.;
Drozdovskaya, M.;
Engrand, C.;
Galand, M.;
Güttler, C.;
Henri, P.;
Herique, A.;
Ivanoski, S.;
Kokotanekova, R.;
Levasseur-Regourd, A. -C.;
Miller, K. E.;
Rotundi, A.;
Schönbächler, M.;
Snodgrass, C.;
Thomas, N.;
Tubiana, C.;
Ulamec, S.;
Vincent, J. -B.
Submitted: 2019-07-25
This white paper proposes that AMBITION, a Comet Nucleus Sample Return
mission, be a cornerstone of ESA's Voyage 2050 programme. We summarise some of
the most important questions still open in cometary science after the successes
of the Rosetta mission, many of which require sample analysis using techniques
that are only possible in laboratories on Earth. We then summarise
measurements, instrumentation and mission scenarios that can address these
questions, with a recommendation that ESA select an ambitious cryogenic sample
return mission. Rendezvous missions to Main Belt comets and Centaurs are
compelling cases for M-class missions, expanding our knowledge by exploring new
classes of comets. AMBITION would engage a wide community, drawing expertise
from a vast range of disciplines within planetary science and astrophysics.
With AMBITION, Europe will continue its leadership in the exploration of the
most primitive Solar System bodies.
[3]
oai:arXiv.org:1702.00192 [pdf] - 1557861
Decay of COSAC and Ptolemy Mass Spectra at Comet
67P/Churyumov-Gerasimenko
Krüger, Harald;
Goesmann, Fred;
Giri, Chaitanya;
Wright, Ian;
Morse, Andrew;
Bredehöft, Jan Hendrik;
Ulamec, Stephan;
Cozzoni, Barbara;
Ehrenfreund, Pascale;
Gautier, Thomas;
McKenna-Lawlor, Susan;
Raulin, Francois;
Steininger, Harald;
Szopa, Cyril
Submitted: 2017-02-01
The Rosetta lander Philae successfully landed on the nucleus of comet
67P/Churyumov-Gerasimenko on 12 November 2014. Philae is equipped with two gas
analyzers: The Cometary Sampling and Composition experiment (COSAC) and the gas
chromatograph and mass spectrometer Ptolemy. On 12 to 14 November 2014 both
instruments measured the organic composition of the comet nucleus material
through seven measurements in sniffing mode during Philae's hopping and at its
final landing site Abydos. We compare the temporal evolution of intensities of
several ion species identified by both mass spectrometers. For COSAC this is
the first analysis of the temporal behaviour of the measured ion species. All
ion species showed the highest intensities in the first spectra measured by
both instruments about 20 to 30 minutes after Philae's first touchdown at
Agilkia, and a decay during the six consecutive measurements at Abydos. Both
instruments measured a nearly identical decay of the water peak (m/z 18), and
also CO (m/z 28) behaved similarly. In the COSAC measurements the peak at m/z
44 decays much slower than all the other ion species, including the water peak.
In particular, the m/z 44 peak decays much slower in the COSAC measurements
than in the Ptolemy data. This supports our earlier interpretation that COSAC
for the first time analyzed a regolith sample from a cometary nucleus in situ,
while Ptolemy measured cometary gas from the ambient coma. The m/z 44 peak
measured by COSAC was likely dominated by organic species, whereas the peak
measured by Ptolemy was interpreted to be mostly due to $CO_2$. Ion species
heavier than m/z 30 tend to decay somewhat slower in the COSAC measurements
than in the Ptolemy data, which may be related to differences in the exhaust
designs between both instruments.