Normalized to: Udem, T.
[1]
oai:arXiv.org:2002.08868 [pdf] - 2052191
A crucial test for astronomical spectrograph calibration with frequency
combs
Probst, Rafael A.;
Milaković, Dinko;
Toledo-Padrón, Borja;
Curto, Gaspare Lo;
Avila, Gerardo;
Brucalassi, Anna;
Martins, Bruno L. Canto;
Leão, Izan de Castro;
Esposito, Massimiliano;
Hernández, Jonay I. González;
Grupp, Frank;
Hänsch, Theodor W.;
Kellermann, Hanna;
Kerber, Florian;
Mandel, Olaf;
Manescau, Antonio;
Pozna, Eszter;
Rebolo, Rafael;
de Medeiros, José Renan;
Steinmetz, Tilo;
Mascareño, Alejandro Suárez;
Udem, Thomas;
Urrutia, Josefina;
Wu, Yuanjie;
Pasquini, Luca;
Holzwarth, Ronald
Submitted: 2020-02-20
Laser frequency combs (LFCs) are well on their way to becoming the
next-generation calibration sources for precision astronomical spectroscopy.
This development is considered key in the hunt for low-mass rocky exoplanets
around solar-type stars whose discovery with the radial-velocity method
requires cm/s Doppler precision. In order to prove such precise calibration
with an LFC, it must be compared to another calibrator of at least the same
precision. Being the best available spectrograph calibrator, this means
comparing it to a second - fully independent - LFC. This test had long been
pending, but our installation of two LFCs at the ultra-stable spectrograph
HARPS presented the so far unique opportunity for simultaneous calibrations
with two separate LFCs. Although limited in time, the test results confirm the
1 cm/s stability that has long been anticipated by the astronomical community.
[2]
oai:arXiv.org:1502.04942 [pdf] - 936337
Comb-calibrated solar spectroscopy through a multiplexed single-mode
fiber channel
Probst, R A;
Wang, L;
Doerr, H-P;
Steinmetz, T;
Kentischer, T J;
Zhao, G;
Hänsch, T W;
Udem, Th;
Holzwarth, R;
Schmidt, W
Submitted: 2015-02-17
We investigate a new scheme for astronomical spectrograph calibration using
the laser frequency comb at the Solar Vacuum Tower Telescope on Tenerife. Our
concept is based upon a single-mode fiber channel, that simultaneously feeds
the spectrograph with comb light and sunlight. This yields nearly perfect
spatial mode matching between the two sources. In combination with the absolute
calibration provided by the frequency comb, this method enables extremely
robust and accurate spectroscopic measurements. The performance of this scheme
is compared to a sequence of alternating comb and sunlight, and to absorption
lines from Earth's atmosphere. We also show how the method can be used for
radial-velocity detection by measuring the well-explored 5-minute oscillations
averaged over the full solar disk. Our method is currently restricted to solar
spectroscopy, but with further evolving fiber-injection techniques it could
become an option even for faint astronomical targets.
[3]
oai:arXiv.org:1310.5087 [pdf] - 1180058
A Frequency Comb calibrated Solar Atlas
Molaro, P.;
Esposito, M.;
Monai, S.;
Hernandez, J. I. Gonzalez;
Hansch, T. W.;
Holzwarth, R.;
Manescau, A.;
Pasquini, L.;
Probst, R. A.;
Rebolo, R.;
Steinmetz, T.;
Udem, Th.;
Wilken, T.
Submitted: 2013-10-18
The solar spectrum is a primary reference for the study of physical processes
in stars and their variation during activity cycles. In Nov 2010 an experiment
with a prototype of a Laser Frequency Comb (LFC) calibration system was
performed with the HARPS spectrograph of the 3.6m ESO telescope at La Silla
during which high signal-to-noise spectra of the Moon were obtained. We exploit
those Echelle spectra to study the optical integrated solar spectrum . The
DAOSPEC program is used to measure solar line positions through gaussian
fitting in an automatic way. We first apply the LFC solar spectrum to
characterize the CCDs of the HARPS spectrograph. The comparison of the LFC and
Th-Ar calibrated spectra reveals S-type distortions on each order along the
whole spectral range with an amplitude of +/-40 m/s. This confirms the pattern
found by Wilken et al. (2010) on a single order and extends the detection of
the distortions to the whole analyzed region revealing that the precise shape
varies with wavelength. A new data reduction is implemented to deal with CCD
pixel inequalities to obtain a wavelength corrected solar spectrum. By using
this spectrum we provide a new LFC calibrated solar atlas with 400 line
positions in the range of 476-530, and 175 lines in the 534-585 nm range. The
new LFC atlas improves the accuracy of individual lines by a significant factor
reaching a mean value of about 10 m/s. The LFC--based solar line wavelengths
are essentially free of major instrumental effects and provide a reference for
absolute solar line positions. We suggest that future LFC observations could be
used to trace small radial velocity changes of the whole solar photospheric
spectrum in connection with the solar cycle and for direct comparison with the
predicted line positions of 3D radiative hydrodynamical models of the solar
photosphere.
[4]
oai:arXiv.org:0809.1663 [pdf] - 16147
Laser frequency combs for astronomical observations
Steinmetz, Tilo;
Wilken, Tobias;
Araujo-Hauck, Constanza;
Holzwarth, Ronald;
Hänsch, Theodor W.;
Pasquini, Luca;
Manescau, Antonio;
D'Odorico, Sandro;
Murphy, Michael T.;
Kentischer, Thomas;
Schmidt, Wolfgang;
Udem, Thomas
Submitted: 2008-09-09
A direct measurement of the universe's expansion history could be made by
observing in real time the evolution of the cosmological redshift of distant
objects. However, this would require measurements of Doppler velocity drifts of
about 1 centimeter per second per year, and astronomical spectrographs have not
yet been calibrated to this tolerance. We demonstrate the first use of a laser
frequency comb for wavelength calibration of an astronomical telescope. Even
with a simple analysis, absolute calibration is achieved with an equivalent
Doppler precision of approximately 9 meters per second at about 1.5 micrometers
- beyond state-of-the-art accuracy. We show that tracking complex, time-varying
systematic effects in the spectrograph and detector system is a particular
advantage of laser frequency comb calibration. This technique promises an
effective means for modeling and removal of such systematic effects to the
accuracy required by future experiments to see direct evidence of the
universe's putative acceleration.
[5]
oai:arXiv.org:astro-ph/0703622 [pdf] - 90431
High-precision wavelength calibration of astronomical spectrographs with
laser frequency combs
Murphy, M. T.;
Udem, Th.;
Holzwarth, R.;
Sizmann, A.;
Pasquini, L.;
Araujo-Hauck, C.;
Dekker, H.;
D'Odorico, S.;
Fischer, M.;
Hänsch, T. W.;
Manescau, A.
Submitted: 2007-03-23, last modified: 2007-06-28
We describe a possible new technique for precise wavelength calibration of
high-resolution astronomical spectrographs using femtosecond-pulsed mode-locked
lasers controlled by stable oscillators such as atomic clocks. Such `frequency
combs' provide a series of narrow modes which are uniformly spaced according to
the laser's pulse repetition rate and whose absolute frequencies are known a
priori with relative precision better than 10^{-12}. Simulations of frequency
comb spectra show that the photon-limited wavelength calibration precision
achievable with existing echelle spectrographs should be ~1 cm/s when
integrated over a 4000A range. Moreover, comb spectra may be used to accurately
characterise distortions of the wavelength scale introduced by the spectrograph
and detector system. The simulations show that frequency combs with pulse
repetition rates of 5-30GHz are required, given the typical resolving power of
existing and possible future echelle spectrographs. Achieving such high
repetition rates, together with the desire to produce all comb modes with
uniform intensity over the entire optical range, represent the only significant
challenges in the design of a practical system. Frequency comb systems may
remove wavelength calibration uncertainties from all practical spectroscopic
experiments, even those combining data from different telescopes over many
decades.