[1]  oai:arXiv.org:1710.07391  [pdf] - 1590057
Design & development of position sensitive detector for hard X-ray using SiPM and new generation scintillators
Comments: Published in SPIE Proceedings Vol. 10392
Submitted: 2017-10-19
There is growing interest in high-energy astrophysics community for the development of sensitive instruments in the hard X-ray energy extending to few hundred keV. This requires position sensitive detector modules with high efficiency in the hard X-ray energy range. Here, we present development of a detector module, which consists of 25 mm x 25 mm CeBr3 scintillation detector, read out by a custom designed two dimensional array of Silicon Photo-Multipliers (SiPM). Readout of common cathode of SiPMs provides the spectral measurement whereas the readout of individual SiPM anodes provides measurement of interaction position in the crystal. Preliminary results for spectral and position measurements with the detector module are presented here.
[2]  oai:arXiv.org:1510.06780  [pdf] - 1298705
Development of a Hard X-ray focal plane Compton Polarimeter: A compact polarimetric configuration with Scintillators and Si photomultipliers
Comments:
Submitted: 2015-10-22
X-ray polarization measurement of cosmic sources provides two unique parameters namely degree and angle of polarization which can probe the emission mechanism and geometry at close vicinity of the compact objects. Specifically, the hard X-ray polarimetry is more rewarding because the sources are expected to be intrinsically highly polarized at higher energies. With the successful implementation of Hard X-ray optics in NuSTAR, it is now feasible to conceive Compton polarimeters as focal plane detectors. Such a configuration is likely to provide sensitive polarization measurements in hard X-rays with a broad energy band. We are developing a focal plane hard X-ray Compton polarimeter consisting of a plastic scintillator as active scatterer surrounded by a cylindrical array of CsI(Tl) scintillators. The scatterer is 5 mm diameter and 100 mm long plastic scintillator (BC404) viewed by normal PMT. The photons scattered by the plastic scatterer are collected by a cylindrical array of 16 CsI(Tl) scintillators (5 mm x 5 mm x 150 mm) which are read by Si Photomultiplier (SiPM). Use of the new generation SiPMs ensures the compactness of the instrument which is essential for the design of focal plane detectors. The expected sensitivity of such polarimetric configuration and complete characterization of the plastic scatterer, specially at lower energies have been discussed in Chattopadhyay et al. (Exp. Astron. 35, 391-412, 2013; Astrophys. J. Suppl. 212, 12, 2014). In this paper, we characterize the CsI(Tl) absorbers coupled to SiPM. We also present the experimental results from the fully assembled configuration of the Compton polarimeter.
[3]  oai:arXiv.org:1312.5471  [pdf] - 1202371
The PRL Stabilized High Resolution Echelle Fiber-fed Spectrograph: Instrument Description & First Radial Velocity Results
Comments: 33 pages, 15 figures, accepted for publication in PASP
Submitted: 2013-12-19
We present spectrograph design details and initial radial velocity results from the PRL optical fiber-fed high-resolution cross-dispersed echelle spectrograph (PARAS), which has recently been commissioned at the Mt Abu 1.2 m telescope, in India. Data obtained as part of the post-commissioning tests with PARAS show velocity precision better than 2m/s over a period of several months on bright RV standard stars. For observations of sigma-Dra we report 1.7m/s precision for a period of seven months and 2.1m/s for HD 9407 over a period of 2 months. PARAS is capable of a single-shot spectral coverage of 3800A - 9500A at a resolution of about 67,000. The RV results were obtained between 3800A and 6900A using simultaneous wavelength calibration with a Thorium-Argon (ThAr) hollow cathode lamp. The spectrograph is maintained under stable conditions of temperature with a precision of 0.01 - 0.02C (rms) at 25.55C, and enclosed in a vacuum vessel at pressure of 0.1 +/-0.03 mbar. The blaze peak efficiency of the spectrograph between 5000A and 6500A, including the detector, is 30%; and about 25% with the fiber transmission. The total efficiency, including spectrograph, fiber transmission, focal ratio degradation (FRD), and telescope (with 81% reflectivity) is about 7% in the same wavelength region on a clear night with good seeing conditions.
[4]  oai:arXiv.org:1007.4280  [pdf] - 1033890
First Light results from PARAS: The PRL Echelle Spectrograph
Comments: To appear in SPIE Proc. 2010, vol. 7035
Submitted: 2010-07-24
We present the first light commissioning results from the Physical Research Laboratory (PRL) optical fiber-fed high resolution cross-dispersed Echelle Spectrograph. It is capable of a single- shot spectral coverage of 3700A to 8600A at R ~ 63,000 and is under very stable conditions of temperature (0.04{\deg}C at 23{\deg}C). In the very near future pressure control will also be achieved by enclosing the entire spectrograph in a low-pressure vacuum chamber (~0.01mbar). It is attached to a 1.2m telescope using two 50micron core optical fibers (one for the star and another for simultaneous Th-Ar spectral calibration). The 1.2m telescope is located at Mt. Abu, India, and we are guaranteed about 80 to 100 nights a year for observations with the spectrograph. The instrument will be ultimately used for radial-velocity searches of exoplanets around 1000 dwarf stars, brighter than 10th magnitude, for the next 5 years with a precision of 3 to 5m/s using the simultaneous Th-Ar spectral lamp reference technique. The spectrograph has already achieved a stability of 3.7m/s in short-term time scale and in the near future we expect the stability to be at 1m/s once we install the spectrograph inside the vacuum chamber.