Normalized to: Ubale, G.
[1]
oai:arXiv.org:1710.07391 [pdf] - 1590057
Design & development of position sensitive detector for hard X-ray using
SiPM and new generation scintillators
Goyal, S. K.;
Naik, Amisha P.;
S., Mithun N. P.;
Vadawale, S. V.;
Tiwari, Neeraj K.;
Chattopadhyay, T.;
Nagrani, N.;
Madhavi, S.;
ladiya, T.;
Patel, A. R.;
Shanmugam, M.;
Adalja, H. L.;
patel, V. R.;
Ubale, G. P.
Submitted: 2017-10-19
There is growing interest in high-energy astrophysics community for the
development of sensitive instruments in the hard X-ray energy extending to few
hundred keV. This requires position sensitive detector modules with high
efficiency in the hard X-ray energy range. Here, we present development of a
detector module, which consists of 25 mm x 25 mm CeBr3 scintillation detector,
read out by a custom designed two dimensional array of Silicon
Photo-Multipliers (SiPM). Readout of common cathode of SiPMs provides the
spectral measurement whereas the readout of individual SiPM anodes provides
measurement of interaction position in the crystal. Preliminary results for
spectral and position measurements with the detector module are presented here.
[2]
oai:arXiv.org:1510.06780 [pdf] - 1298705
Development of a Hard X-ray focal plane Compton Polarimeter: A compact
polarimetric configuration with Scintillators and Si photomultipliers
Chattopadhyay, T.;
Vadawale, S. V.;
Goyal, S. K.;
S., Mithun N. P.;
Patel, A. R.;
Shukla, R.;
Ladiya, T.;
Shanmugam, M.;
Patel, V. R.;
Ubale, G. P.
Submitted: 2015-10-22
X-ray polarization measurement of cosmic sources provides two unique
parameters namely degree and angle of polarization which can probe the emission
mechanism and geometry at close vicinity of the compact objects. Specifically,
the hard X-ray polarimetry is more rewarding because the sources are expected
to be intrinsically highly polarized at higher energies. With the successful
implementation of Hard X-ray optics in NuSTAR, it is now feasible to conceive
Compton polarimeters as focal plane detectors. Such a configuration is likely
to provide sensitive polarization measurements in hard X-rays with a broad
energy band. We are developing a focal plane hard X-ray Compton polarimeter
consisting of a plastic scintillator as active scatterer surrounded by a
cylindrical array of CsI(Tl) scintillators. The scatterer is 5 mm diameter and
100 mm long plastic scintillator (BC404) viewed by normal PMT. The photons
scattered by the plastic scatterer are collected by a cylindrical array of 16
CsI(Tl) scintillators (5 mm x 5 mm x 150 mm) which are read by Si
Photomultiplier (SiPM). Use of the new generation SiPMs ensures the compactness
of the instrument which is essential for the design of focal plane detectors.
The expected sensitivity of such polarimetric configuration and complete
characterization of the plastic scatterer, specially at lower energies have
been discussed in Chattopadhyay et al. (Exp. Astron. 35, 391-412, 2013;
Astrophys. J. Suppl. 212, 12, 2014). In this paper, we characterize the CsI(Tl)
absorbers coupled to SiPM. We also present the experimental results from the
fully assembled configuration of the Compton polarimeter.
[3]
oai:arXiv.org:1312.5471 [pdf] - 1202371
The PRL Stabilized High Resolution Echelle Fiber-fed Spectrograph:
Instrument Description & First Radial Velocity Results
Chakraborty, Abhijit;
Mahadevan, Suvrath;
Roy, Arpita;
Dixit, Vaibhav;
Richardson, Eric Harvey;
Dongre, Varun;
Pathan, F. M.;
Chaturvedi, Priyanka;
Shah, Vishal;
Ubale, Girish P.;
Anandarao, B. G.
Submitted: 2013-12-19
We present spectrograph design details and initial radial velocity results
from the PRL optical fiber-fed high-resolution cross-dispersed echelle
spectrograph (PARAS), which has recently been commissioned at the Mt Abu 1.2 m
telescope, in India. Data obtained as part of the post-commissioning tests with
PARAS show velocity precision better than 2m/s over a period of several months
on bright RV standard stars. For observations of sigma-Dra we report 1.7m/s
precision for a period of seven months and 2.1m/s for HD 9407 over a period of
2 months. PARAS is capable of a single-shot spectral coverage of 3800A - 9500A
at a resolution of about 67,000. The RV results were obtained between 3800A and
6900A using simultaneous wavelength calibration with a Thorium-Argon (ThAr)
hollow cathode lamp. The spectrograph is maintained under stable conditions of
temperature with a precision of 0.01 - 0.02C (rms) at 25.55C, and enclosed in a
vacuum vessel at pressure of 0.1 +/-0.03 mbar. The blaze peak efficiency of the
spectrograph between 5000A and 6500A, including the detector, is 30%; and about
25% with the fiber transmission. The total efficiency, including spectrograph,
fiber transmission, focal ratio degradation (FRD), and telescope (with 81%
reflectivity) is about 7% in the same wavelength region on a clear night with
good seeing conditions.
[4]
oai:arXiv.org:1007.4280 [pdf] - 1033890
First Light results from PARAS: The PRL Echelle Spectrograph
Submitted: 2010-07-24
We present the first light commissioning results from the Physical Research
Laboratory (PRL) optical fiber-fed high resolution cross-dispersed Echelle
Spectrograph. It is capable of a single- shot spectral coverage of 3700A to
8600A at R ~ 63,000 and is under very stable conditions of temperature
(0.04{\deg}C at 23{\deg}C). In the very near future pressure control will also
be achieved by enclosing the entire spectrograph in a low-pressure vacuum
chamber (~0.01mbar). It is attached to a 1.2m telescope using two 50micron core
optical fibers (one for the star and another for simultaneous Th-Ar spectral
calibration). The 1.2m telescope is located at Mt. Abu, India, and we are
guaranteed about 80 to 100 nights a year for observations with the
spectrograph. The instrument will be ultimately used for radial-velocity
searches of exoplanets around 1000 dwarf stars, brighter than 10th magnitude,
for the next 5 years with a precision of 3 to 5m/s using the simultaneous Th-Ar
spectral lamp reference technique. The spectrograph has already achieved a
stability of 3.7m/s in short-term time scale and in the near future we expect
the stability to be at 1m/s once we install the spectrograph inside the vacuum
chamber.