Normalized to: Turver, K.
[1]
oai:arXiv.org:astro-ph/9906136 [pdf] - 1943626
TeV Measurements of Young Pulsars and Supernova Remnants
Submitted: 1999-06-08
Observations have been made with the University of Durham Mark 6 telescope of
a number of supernova remnants and young pulsars (Vela pulsar, PSR B1055-52,
PSR J1105-6107, PSR J0537-6910 and PSR B0540-69). No VHE gamma ray emission,
either steady or pulsed, has been detected from these objects.
[2]
oai:arXiv.org:astro-ph/9906132 [pdf] - 106853
VHE Gamma Rays from PKS 2155-304
Submitted: 1999-06-08
The X-ray selected BL Lac PKS 2155-304 has been observed using the University
of Durham Mark 6 very high energy gamma ray telescope during 1998. We find no
evidence for TeV emission during these recent observations when the X-ray flux
was observed to be low. We have reconsidered our measurements made in 1997
November when PKS 2155-304 was in a bright X-ray state and extended X-ray and
GeV gamma ray observations were made as part of a multiwavelength campaign.
Comparisons are made of the VHE emission during this time with the available
data from other wavelengths.
[3]
oai:arXiv.org:astro-ph/9906134 [pdf] - 106855
Measurements of Flux Limits for TeV Emission from AGNs
Submitted: 1999-06-08
The University of Durham Mark 6 Telescope has been used to make observations
of a number of AGNs visible from the Southern Hemisphere. Results are presented
for limits to VHE gamma ray emission from 1ES 0323+022, PKS 0829+046, 1ES
1101-232, Cen A, PKS 1514-24, RXJ 10578-275 and 1ES 2316-423, both for steady
emission and for outbursts on timescales of ~ 1 day.
[4]
oai:arXiv.org:astro-ph/9906137 [pdf] - 106858
TeV Gamma Ray Emission from Cen X-3
Submitted: 1999-06-08
Cen X-3 is a well-studied high-mass accreting X-ray binary and a variable
source of high energy gamma rays from 100 MeV to 1 TeV. The object has been
extensively monitored with the University of Durham Mark 6 telescope. Results
of observations, including those taken in 1998 and 1999, are reported. There is
no evidence for time variability in all the VHE data. There is also no evidence
for correlation of the VHE flux with the X-ray flux detected by BATSE and
RXTE/ASM. A search for periodic emission, at or close to the X-ray spin period,
in the VHE data yielded a 3 sigma upper limit to the pulsed flux of 2.0 x
10^-12 cm^-2 s^-1.
[5]
oai:arXiv.org:astro-ph/9906138 [pdf] - 106859
The energy spectra of TeV sources measured with the Durham Mark 6
Telescope
Submitted: 1999-06-08
A programme of detailed simulations of the response of the Durham Mark 6
atmospheric Cherenkov telescope is in progress. The effective collecting area
for triggering by gamma-ray showers after application of selection criteria is
derived as a function of energy. An initial result from the larger events in
the 1996 and 1997 observations of the BL Lac PKS 2155-304 is that the time
averaged flux above 1.5 TeV was (6.7 +/- 2.2) x 10^-8 m^-2 s^-1.
[6]
oai:arXiv.org:astro-ph/9906139 [pdf] - 106860
Geomagnetic Effects on the Performance of Atmospheric Cerenkov
Telescopes
Submitted: 1999-06-08
Atmospheric Cerenkov telescopes are used to detect electromagnetic showers
from primary gamma rays of energy > 300 GeV and to discriminate these from
cascades due to hadrons using the shape and orientation of the Cerenkov images.
The geomagnetic field affects the development of showers and diffuses and
distorts the images. When the component of the field normal to the shower axis
is sufficiently large (> 0.4 G) the performance of gamma ray telescopes may be
affected.
[7]
oai:arXiv.org:astro-ph/9904405 [pdf] - 106302
Observations of TeV gamma rays from Markarian 501 at large zenith angles
Submitted: 1999-04-29
TeV gamma rays from the blazar Markarian 501 have been detected with the
University of Durham Mark 6 atmospheric Cerenkov telescope using the imaging
technique at large zenith angles. Observations were made at zenith angles in
the range 70 - 73 deg during 1997 July and August when Markarian 501 was
undergoing a prolonged and strong flare.
[8]
oai:arXiv.org:astro-ph/9904082 [pdf] - 105979
Geomagnetic effects on atmospheric Cerenkov images
Submitted: 1999-04-07
Atmospheric Cerenkov telescopes are used to detect electromagnetic showers
from primary gamma rays of energy ~300 GeV - ~10 TeV and to discriminate these
from cascades due to hadrons using the Cerenkov images. The geomagnetic field
affects the development of showers and is shown to diffuse and distort the
images. When the component of the field normal to the shower axis is
sufficiently large (> 0.4 G) the performance of gamma ray telescopes may be
affected, although corrections should be possible.
[9]
oai:arXiv.org:astro-ph/9903346 [pdf] - 1521665
A Search for VHE Gamma Rays from AGNs Visible from the Southern
Hemisphere
Submitted: 1999-03-23
Observations have been made, using the University of Durham Mark 6 gamma ray
telescope, of the very high energy gamma ray emission from a number of active
galactic nuclei visible from the Southern hemisphere. Limits are presented to
the VHE gamma ray emission from 1ES 0323+022, PKS 0829+046, 1ES 1101--232, Cen
A, PKS 1514-24, RXJ 10578-275, and 1ES 2316-423, both for steady long-term
emission and for outbursts of emission on timescales of 1 day.
[10]
oai:arXiv.org:astro-ph/9811094 [pdf] - 103720
Correlation between the X-ray and TeV Gamma Ray Emission from an
Accreting X-ray Binary
Submitted: 1998-11-05, last modified: 1999-01-18
This paper has been withdrawn by the authors.
[11]
oai:arXiv.org:astro-ph/9812123 [pdf] - 104230
Correlation between the TeV gamma ray and X-ray emission from an
accreting X-ray binary
Submitted: 1998-12-07, last modified: 1999-01-18
This paper has been withdrawn by the authors.
[12]
oai:arXiv.org:astro-ph/9812122 [pdf] - 104229
PKS 2155-304 - a source of VHE gamma-rays
Chadwick, P. M.;
Lyons, K.;
McComb, T. J. L.;
McQueen, S.;
Orford, K. J.;
Osborne, J. L.;
Rayner, S. M.;
Shaw, S. E.;
Turver, K. E.;
Wieczorek, G. J.
Submitted: 1998-12-07
The close X-ray selected BL Lac PKS 2155--304 has been observed using the
University of Durham Mark 6 very high energy (VHE) gamma ray telescope during
1996 September/October/November and 1997 October/November. VHE gamma rays with
energy > 300 GeV were detected with a time-averaged integral flux of (4.2 +/-
0.7 (stat) +/- 2.0 (sys)) x 10^-11 cm^-2 s^-1. There is evidence for VHE gamma
ray emission during our observations in 1996 September and 1997
October/November. The strongest emission was detected in 1997 November, when
the object was producing the largest flux ever recorded in high-energy X-rays
and was detected in > 100 MeV gamma-rays. The VHE and X-ray fluxes are
correlated.
[13]
oai:arXiv.org:astro-ph/9810496 [pdf] - 103612
Measurement of sky clarity using FIR radiometers as an adjunct to
atmospheric Cerenkov radiation measurements
Submitted: 1998-10-30
A technique for detecting the presence of cloud in the field of view of an
atmospheric Cerenkov telescope using a far infra red radiometer is described.
Models for the radiative emission from clear and cloudy skies are tested and
found to represent the measurements.
[14]
oai:arXiv.org:astro-ph/9810209 [pdf] - 1521664
VHE Gamma Rays from PKS 2155-304
Submitted: 1998-10-14
The close X-ray selected BL Lac PKS 2155-304 has been observed using the
University of Durham Mark 6 very high energy (VHE) gamma ray telescope during
1996 September/October/November and 1997 October/November. VHE gamma rays with
energy > 300 GeV were detected from this object with a time-averaged integral
flux of (4.2 +/- 0.7 (stat) +/- 2.0 (sys)) x 10^(-11) per cm2 per s. There is
evidence for VHE gamma ray emission during our observations in 1996 September
and 1997 October/November, with the strongest emission being detected in 1997
November, when the object was producing the largest flux ever recorded in
high-energy X-rays and was detected in > 100 MeV gamma-rays. The VHE and X-ray
fluxes show evidence of a correlation.
[15]
oai:arXiv.org:astro-ph/9804224 [pdf] - 101105
TeV gamma rays from PSR 1706-44
Chadwick, P. M.;
Dickinson, M. R.;
Dipper, N. A.;
Holder, J.;
Kendall, T. R.;
McComb, T. J. L.;
Orford, K. J.;
Osborne, J. L.;
Rayner, S. M.;
Roberts, I. D.;
Shaw, S. E.;
Turver, K. E.
Submitted: 1998-04-22
Observations made with the University of Durham Mark 6 atmospheric Cerenkov
telescope confirm that PSR B1706-44 is a very high energy gamma-ray emitter.
There is no indication from our dataset that the very high energy gamma-rays
are pulsed, in contrast to the findings at < 20 GeV, which indicate that more
than 80% of the flux is pulsed. The flux at E > 300 GeV is estimated to be (3.9
+/- 0.7 (statistical)) x 10^-11 cm^-2 s^-1.
[16]
oai:arXiv.org:astro-ph/9804212 [pdf] - 339138
The Uuniversity of Durham Mark 6 Gamma Ray Telescope
Armstrong, P.;
Chadwick, P. M.;
Cottle, P. J.;
Dickinson, J. E.;
Dickinson, M. R.;
Dipper, N. A.;
Hilton, S. E.;
Hogg, W.;
Holder, J.;
Kendall, T. R.;
McComb, T. J. L.;
Moore, C. M.;
Orford, K. J.;
Rayner, S. M.;
Roberts, I. D.;
Roberts, M. D.;
Robertshaw, M.;
Shaw, S. E.;
Tindale, K.;
Tummey, S. P.;
Turver, K. E.
Submitted: 1998-04-21
The design, construction and operation of the University of Durham
ground-based gamma ray telescope is discussed. The telescope has been designed
to detect gamma rays in the < 200 GeV region and to achieve good discrimination
between gamma ray and hadron initiated showers in the higher energy region (>
300 GeV). The telescope was commissioned in 1995 and a description of its
design and operation is presented, together with a verification of the
telescope's performance
[17]
oai:arXiv.org:astro-ph/9802338 [pdf] - 100509
Centaurus X-3 - A Source of High Energy Gamma Rays
Chadwick, P. M.;
Dickinson, M. R.;
Dipper, N. A.;
Kendall, T. R.;
McComb, T. J. L.;
Orford, K. J.;
Osborne, J. L.;
Rayner, S. M.;
Roberts, I. D.;
Shaw, S. E.;
Turver, K. E.
Submitted: 1998-02-26
Centaurus X-3 is a well-studied high-mass accreting X-ray binary and a
variable source of high energy gamma rays with energies from 100 MeV to 1 TeV.
Previous results have suggested that the origin of the gamma rays is not the
immediate vicinity of the neutron star but is sited in the accretion disc,
perhaps in an accretion wake. The Durham Mark 6 gamma ray telescope has been
used to measure the gamma ray flux from Centaurus X-3 with much higher
sensitivity than previous ground-based measurements. The flux above ~ 400 GeV
was measured to be (2 +/- 0.3) x 10^-11 cm^-2 s^-1 and appears constant over a
period of 2 - 3 months. In 10 hours of observations there is no evidence for
periodicity in the detected gamma rays at the X-ray spin period either from a
site in the region of the neutron star, or from any other potential site in the
orbit.