sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Tucker, Robin W.

Normalized to: Tucker, R.

23 article(s) in total. 171 co-authors, from 1 to 19 common article(s). Median position in authors list is 44,0.

[1]  oai:arXiv.org:2002.05771  [pdf] - 2080996
Particle response of antenna-coupled TES arrays: results from SPIDER and the lab
Comments: 9 pages, 6 figures, Proceedings of the 18th International Workshop on Low Temperature Detectors
Submitted: 2020-02-13
Future mm-wave and sub-mm space missions will employ large arrays of multiplexed Transition Edge Sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce "glitches" in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers and multiplexed readout wiring. In this work we explore the susceptibility of modern TES arrays to the cosmic ray environment of space using two data sets: the 2015 long-duration balloon flight of the SPIDER cosmic microwave background polarimeter, and a laboratory exposure of SPIDER flight hardware to radioactive sources. We find manageable glitch rates and short glitch durations, leading to minimal effect on SPIDER analysis. We constrain energy propagation within the substrate through a study of multi-detector coincidences, and give a preliminary look at pulse shapes in laboratory data.
[2]  oai:arXiv.org:1801.09389  [pdf] - 1709328
Modeling D-Region Ionospheric Response of the Great American TSE of August 21, 2017 from VLF signal perturbation
Comments: 22 pages, 11 Figures, Submitted in Advances in Space Research (ASR) on 1 Jan. 2018
Submitted: 2018-01-29
Solar eclipse is an unique opportunity to study the lower ionospheric variabilities under a controlled perturbation when the solar ultraviolet and X-ray are temporally occulted by the lunar disk. Sub-ionospheric Very Low Frequency (VLF) radio signal displays the ionospheric response of solar eclipse by modulating its amplitude and phase. During the Total Solar Eclipse (TSE) on August 21, 2017 in North America, data was recorded by a number of receivers as presented in public archive. Out of these, two receiving stations YADA in McBaine and K5TD in Tulsa could procure a reasonable quality of noise free data where the signal amplitude was clearly modulated due to the eclipse. During the lunar occultation, a C3.0 solar flare occurred and the signal received from Tulsa manifested the effect of sudden ionization due to the flare. The VLF amplitude in Tulsa shows the effect which is generally understood by superimposing effects of both the solar eclipse and flare. However, the signal by YADA did not perturb by the solar flare, as the flaring region was totally behind the lunar disk for the entire period. We numerically reproduced the observed signal amplitude variation at both the receiving locations by using Wait's two component D-region ionospheric model and the well-known Long Wavelength Propagation Capability (LWPC) code. The perturbed electron density for both the cases is computed which matches satisfactorily with the true ionospheric conditions.
[3]  oai:arXiv.org:1711.10596  [pdf] - 1783704
SPIDER: CMB polarimetry from the edge of space
Comments: 10 pages, 7 figures, LTD17 Conference
Submitted: 2017-11-28
SPIDER is a balloon-borne instrument designed to map the polarization of the millimeter-wave sky at large angular scales. SPIDER targets the B-mode signature of primordial gravitational waves in the cosmic microwave background (CMB), with a focus on mapping a large sky area with high fidelity at multiple frequencies. SPIDER's first longduration balloon (LDB) flight in January 2015 deployed a total of 2400 antenna-coupled Transition Edge Sensors (TESs) at 90 GHz and 150 GHz. In this work we review the design and in-flight performance of the SPIDER instrument, with a particular focus on the measured performance of the detectors and instrument in a space-like loading and radiation environment. SPIDER's second flight in December 2018 will incorporate payload upgrades and new receivers to map the sky at 285 GHz, providing valuable information for cleaning polarized dust emission from CMB maps.
[4]  oai:arXiv.org:1711.04169  [pdf] - 1755845
280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2 Suborbital Polarimeter
Comments:
Submitted: 2017-11-11, last modified: 2017-11-22
We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated silicon feedhorns coupled to an array of aluminum-manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1,530 polarization sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be ~3 pW at 300 mK with a less than 6% variation across each array at one standard deviation. These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.
[5]  oai:arXiv.org:1704.00215  [pdf] - 1582291
A New Limit on CMB Circular Polarization from SPIDER
Comments: 9 pages, 4 figures, 5 tables - Updated to version accepted for publication in ApJ, modified acknowledgements
Submitted: 2017-04-01, last modified: 2017-08-11
We present a new upper limit on CMB circular polarization from the 2015 flight of SPIDER, a balloon-borne telescope designed to search for $B$-mode linear polarization from cosmic inflation. Although the level of circular polarization in the CMB is predicted to be very small, experimental limits provide a valuable test of the underlying models. By exploiting the non-zero circular-to-linear polarization coupling of the HWP polarization modulators, data from SPIDER's 2015 Antarctic flight provide a constraint on Stokes $V$ at 95 and 150 GHz from $33<\ell<307$. No other limits exist over this full range of angular scales, and SPIDER improves upon the previous limit by several orders of magnitude, providing 95% C.L. constraints on $\ell (\ell+1)C_{\ell}^{VV}/(2\pi)$ ranging from 141 $\mu K ^2$ to 255 $\mu K ^2$ at 150 GHz for a thermal CMB spectrum. As linear CMB polarization experiments become increasingly sensitive, the techniques described in this paper can be applied to obtain even stronger constraints on circular polarization.
[6]  oai:arXiv.org:1609.07322  [pdf] - 1531713
On Gravitational Chirality as the Genesis of Astrophysical Jets
Comments: 16 pages, 10 figures; Updated version accepted by CQG
Submitted: 2016-09-23, last modified: 2016-12-12
It has been suggested that single and double jets observed emanating from certain astrophysical objects may have a purely gravitational origin. We discuss new classes of plane-fronted and pulsed gravitational wave solutions to the equation for perturbations of Ricci-flat spacetimes around Minkowski metrics, as models for the genesis of such phenomena. These solutions are classified in terms of their chirality and generate a family of non-stationary spacetime metrics. Particular members of these families are used as backgrounds in analysing time-like solutions to the geodesic equation for test particles. They are found numerically to exhibit both single and double jet-like features with dimensionless aspect ratios suggesting that it may be profitable to include such backgrounds in simulations of astrophysical jet dynamics from rotating accretion discs involving electromagnetic fields.
[7]  oai:arXiv.org:1510.01771  [pdf] - 1337397
A cryogenic rotation stage with a large clear aperture for the half-wave plates in the Spider instrument
Comments: 11 pages, 7 figures, Published in Review of Scientific Instruments. v2 includes reviewer changes and longer literature review
Submitted: 2015-10-06, last modified: 2016-01-08
We describe the cryogenic half-wave plate rotation mechanisms built for and used in Spider, a polarization-sensitive balloon-borne telescope array that observed the Cosmic Microwave Background at 95 GHz and 150 GHz during a stratospheric balloon flight from Antarctica in January 2015. The mechanisms operate at liquid helium temperature in flight. A three-point contact design keeps the mechanical bearings relatively small but allows for a large (305 mm) diameter clear aperture. A worm gear driven by a cryogenic stepper motor allows for precise positioning and prevents undesired rotation when the motors are depowered. A custom-built optical encoder system monitors the bearing angle to an absolute accuracy of +/- 0.1 degrees. The system performed well in Spider during its successful 16 day flight.
[8]  oai:arXiv.org:1506.06953  [pdf] - 1275488
The Thermal Design, Characterization, and Performance of the SPIDER Long-Duration Balloon Cryostat
Comments: 15 pgs, 17 figs
Submitted: 2015-06-23, last modified: 2015-09-11
We describe the SPIDER flight cryostat, which is designed to cool six millimeter-wavelength telescopes during an Antarctic long-duration balloon flight. The cryostat, one of the largest to have flown on a stratospheric payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6 K. Stainless steel capillaries facilitate a high flow impedance connection between the main liquid helium tank and a smaller superfluid tank, allowing the latter to operate at 1.6 K as long as there is liquid in the 4.2 K main tank. Each telescope houses a closed cycle helium-3 adsorption refrigerator that further cools the focal planes down to 300 mK. Liquid helium vapor from the main tank is routed through heat exchangers that cool radiation shields, providing negative thermal feedback. The system performed successfully during a 17 day flight in the 2014-2015 Antarctic summer. The cryostat had a total hold time of 16.8 days, with 15.9 days occurring during flight.
[9]  oai:arXiv.org:1502.00619  [pdf] - 1300145
Antenna-coupled TES bolometers used in BICEP2, Keck array, and SPIDER
Comments: 16 pgs, 20 figs
Submitted: 2015-02-02
We have developed antenna-coupled transition-edge sensor (TES) bolometers for a wide range of cosmic microwave background (CMB) polarimetry experiments, including BICEP2, Keck Array, and the balloon borne SPIDER. These detectors have reached maturity and this paper reports on their design principles, overall performance, and key challenges associated with design and production. Our detector arrays repeatedly produce spectral bands with 20%-30% bandwidth at 95, 150, or 220~GHz. The integrated antenna arrays synthesize symmetric co-aligned beams with controlled side-lobe levels. Cross-polarized response on boresight is typically ~0.5%, consistent with cross-talk in our multiplexed readout system. End-to-end optical efficiencies in our cameras are routinely 35% or higher, with per detector sensitivities of NET~300 uKrts. Thanks to the scalability of this design, we have deployed 2560 detectors as 1280 matched pairs in Keck Array with a combined instantaneous sensitivity of ~9 uKrts, as measured directly from CMB maps in the 2013 season. Similar arrays have recently flown in the SPIDER instrument, and development of this technology is ongoing.
[10]  oai:arXiv.org:1407.1883  [pdf] - 1215475
Attitude determination for balloon-borne experiments
Comments: 16 pages, 10 figures, Presented at SPIE Ground-based and Airborne Telescopes V, June 23, 2014. To be published in Proceedings of SPIE Volume 9145
Submitted: 2014-07-07, last modified: 2014-07-15
An attitude determination system for balloon-borne experiments is presented. The system provides pointing information in azimuth and elevation for instruments flying on stratospheric balloons over Antarctica. In-flight attitude is given by the real-time combination of readings from star cameras, a magnetometer, sun sensors, GPS, gyroscopes, tilt sensors and an elevation encoder. Post-flight attitude reconstruction is determined from star camera solutions, interpolated by the gyroscopes using an extended Kalman Filter. The multi-sensor system was employed by the Balloon-borne Large Aperture Submillimeter Telescope for Polarimetry (BLASTPol), an experiment that measures polarized thermal emission from interstellar dust clouds. A similar system was designed for the upcoming flight of SPIDER, a Cosmic Microwave Background polarization experiment. The pointing requirements for these experiments are discussed, as well as the challenges in designing attitude reconstruction systems for high altitude balloon flights. In the 2010 and 2012 BLASTPol flights from McMurdo Station, Antarctica, the system demonstrated an accuracy of <5' rms in-flight, and <5" rms post-flight.
[11]  oai:arXiv.org:1407.2906  [pdf] - 1215590
Pre-flight integration and characterization of the SPIDER balloon-borne telescope
Comments: 25 pages, 14 figures. Presented at SPIE Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy VII, June 26, 2014. To be published in Proceedings of SPIE Volume 9153
Submitted: 2014-07-09
We present the results of integration and characterization of the SPIDER instrument after the 2013 pre-flight campaign. SPIDER is a balloon-borne polarimeter designed to probe the primordial gravitational wave signal in the degree-scale $B$-mode polarization of the cosmic microwave background. With six independent telescopes housing over 2000 detectors in the 94 GHz and 150 GHz frequency bands, SPIDER will map 7.5% of the sky with a depth of 11 to 14 $\mu$K$\cdot$arcmin at each frequency, which is a factor of $\sim$5 improvement over Planck. We discuss the integration of the pointing, cryogenic, electronics, and power sub-systems, as well as pre-flight characterization of the detectors and optical systems. SPIDER is well prepared for a December 2014 flight from Antarctica, and is expected to be limited by astrophysical foreground emission, and not instrumental sensitivity, over the survey region.
[12]  oai:arXiv.org:1407.1880  [pdf] - 1215472
Pointing control for the SPIDER balloon-borne telescope
Comments: 20 pages, 12 figures, Presented at SPIE Ground-based and Airborne Telescopes V, June 23, 2014. To be published in Proceedings of SPIE Volume 9145
Submitted: 2014-07-07
We present the technology and control methods developed for the pointing system of the SPIDER experiment. SPIDER is a balloon-borne polarimeter designed to detect the imprint of primordial gravitational waves in the polarization of the Cosmic Microwave Background radiation. We describe the two main components of the telescope's azimuth drive: the reaction wheel and the motorized pivot. A 13 kHz PI control loop runs on a digital signal processor, with feedback from fibre optic rate gyroscopes. This system can control azimuthal speed with < 0.02 deg/s RMS error. To control elevation, SPIDER uses stepper-motor-driven linear actuators to rotate the cryostat, which houses the optical instruments, relative to the outer frame. With the velocity in each axis controlled in this way, higher-level control loops on the onboard flight computers can implement the pointing and scanning observation modes required for the experiment. We have accomplished the non-trivial task of scanning a 5000 lb payload sinusoidally in azimuth at a peak acceleration of 0.8 deg/s$^2$, and a peak speed of 6 deg/s. We can do so while reliably achieving sub-arcminute pointing control accuracy.
[13]  oai:arXiv.org:1407.1881  [pdf] - 1215473
Design and construction of a carbon fiber gondola for the SPIDER balloon-borne telescope
Comments: 16 pages, 11 figures. Presented at SPIE Ground-based and Airborne Telescopes V, June 23, 2014. To be published in Proceedings of SPIE Volume 9145
Submitted: 2014-07-07
We introduce the light-weight carbon fiber and aluminum gondola designed for the SPIDER balloon-borne telescope. SPIDER is designed to measure the polarization of the Cosmic Microwave Background radiation with unprecedented sensitivity and control of systematics in search of the imprint of inflation: a period of exponential expansion in the early Universe. The requirements of this balloon-borne instrument put tight constrains on the mass budget of the payload. The SPIDER gondola is designed to house the experiment and guarantee its operational and structural integrity during its balloon-borne flight, while using less than 10% of the total mass of the payload. We present a construction method for the gondola based on carbon fiber reinforced polymer tubes with aluminum inserts and aluminum multi-tube joints. We describe the validation of the model through Finite Element Analysis and mechanical tests.
[14]  oai:arXiv.org:1407.1882  [pdf] - 1215474
BLASTbus electronics: general-purpose readout and control for balloon-borne experiments
Comments: Presented at SPIE Ground-based and Airborne Telescopes V, June 23, 2014. To be published in Proceedings of SPIE Volume 9145
Submitted: 2014-07-07
We present the second generation BLASTbus electronics. The primary purposes of this system are detector readout, attitude control, and cryogenic housekeeping, for balloon-borne telescopes. Readout of neutron transmutation doped germanium (NTD-Ge) bolometers requires low noise and parallel acquisition of hundreds of analog signals. Controlling a telescope's attitude requires the capability to interface to a wide variety of sensors and motors, and to use them together in a fast, closed loop. To achieve these different goals, the BLASTbus system employs a flexible motherboard-daughterboard architecture. The programmable motherboard features a digital signal processor (DSP) and field-programmable gate array (FPGA), as well as slots for three daughterboards. The daughterboards provide the interface to the outside world, with versions for analog to digital conversion, and optoisolated digital input/output. With the versatility afforded by this design, the BLASTbus also finds uses in cryogenic, thermometry, and power systems. For accurate timing control to tie everything together, the system operates in a fully synchronous manner. BLASTbus electronics have been successfully deployed to the South Pole, and flown on stratospheric balloons.
[15]  oai:arXiv.org:1106.3087  [pdf] - 659433
SPIDER: Probing the Early Universe with a Suborbital Polarimeter
Comments: 29 pages, 8 figures, 4 tables; v2: matches published version, flight schedule updated, two typos fixed in Table 2, references and minor clarifications added, results unchanged
Submitted: 2011-06-15, last modified: 2013-05-02
We evaluate the ability of SPIDER, a balloon-borne polarimeter, to detect a divergence-free polarization pattern ("B-modes") in the Cosmic Microwave Background (CMB). In the inflationary scenario, the amplitude of this signal is proportional to that of the primordial scalar perturbations through the tensor-to-scalar ratio r. We show that the expected level of systematic error in the SPIDER instrument is significantly below the amplitude of an interesting cosmological signal with r=0.03. We present a scanning strategy that enables us to minimize uncertainty in the reconstruction of the Stokes parameters used to characterize the CMB, while accessing a relatively wide range of angular scales. Evaluating the amplitude of the polarized Galactic emission in the SPIDER field, we conclude that the polarized emission from interstellar dust is as bright or brighter than the cosmological signal at all SPIDER frequencies (90 GHz, 150 GHz, and 280 GHz), a situation similar to that found in the "Southern Hole." We show that two ~20-day flights of the SPIDER instrument can constrain the amplitude of the B-mode signal to r<0.03 (99% CL) even when foreground contamination is taken into account. In the absence of foregrounds, the same limit can be reached after one 20-day flight.
[16]  oai:arXiv.org:1208.1247  [pdf] - 1150545
Antenna-coupled TES bolometers for the Keck Array, Spider, and Polar-1
Comments: Presented at SPIE Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy VI, July 6, 2012. To be published in Proceedings of SPIE Volume 8452
Submitted: 2012-08-06
Between the BICEP2 and Keck Array experiments, we have deployed over 1500 dual polarized antenna coupled bolometers to map the Cosmic Microwave Background's polarization. We have been able to rapidly deploy these detectors because they are completely planar with an integrated phased-array antenna. Through our experience in these experiments, we have learned of several challenges with this technology- specifically the beam synthesis in the antenna- and in this paper we report on how we have modified our designs to mitigate these challenges. In particular, we discus differential steering errors between the polarization pairs' beam centroids due to microstrip cross talk and gradients of penetration depth in the niobium thin films of our millimeter wave circuits. We also discuss how we have suppressed side lobe response with a Gaussian taper of our antenna illumination pattern. These improvements will be used in Spider, Polar-1, and this season's retrofit of Keck Array.
[17]  oai:arXiv.org:1106.2507  [pdf] - 372118
Thermal architecture for the SPIDER flight cryostat
Comments: 11 pages, 4 figures; as published in the conference proceedings for SPIE Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy V (2010)
Submitted: 2011-06-13
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooling power to multiple focal planes, which are housed in monochromatic telescope inserts. The main helium tank is suspended inside the vacuum vessel with thermally insulating fiberglass flexures, and shielded from thermal radiation by a combination of two vapor cooled shields and multi-layer insulation. This system allows for an extremely low instrumental background and a hold time in excess of 25 days. The total mass of the cryogenic system, including cryogens, is approximately 1000 kg. This enables conventional long duration balloon flights. We will discuss the design, thermal analysis, and qualification of the cryogenic system.
[18]  oai:arXiv.org:1106.2173  [pdf] - 372068
Design and performance of the Spider instrument
Comments: 12 pages, 5 figures, Proceedings of SPIE, Astronomical Telescopes and Instrumentation 2010, San Diego, CA
Submitted: 2011-06-10
Here we describe the design and performance of the Spider instrument. Spider is a balloon-borne cosmic microwave background polarization imager that will map part of the sky at 90, 145, and 280 GHz with sub-degree resolution and high sensitivity. This paper discusses the general design principles of the instrument inserts, mechanical structures, optics, focal plane architecture, thermal architecture, and magnetic shielding of the TES sensors and SQUID multiplexer. We also describe the optical, noise, and magnetic shielding performance of the 145 GHz prototype instrument insert.
[19]  oai:arXiv.org:1106.2158  [pdf] - 371654
SPIDER: a balloon-borne CMB polarimeter for large angular scales
Comments: 12 pages, 6 figures; as published in the conference proceedings for SPIE Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy V (2010)
Submitted: 2011-06-10
We describe SPIDER, a balloon-borne instrument to map the polarization of the millimeter-wave sky with degree angular resolution. Spider consists of six monochromatic refracting telescopes, each illuminating a focal plane of large-format antenna-coupled bolometer arrays. A total of 2,624 superconducting transition-edge sensors are distributed among three observing bands centered at 90, 150, and 280 GHz. A cold half-wave plate at the aperture of each telescope modulates the polarization of incoming light to control systematics. Spider's first flight will be a 20-30-day Antarctic balloon campaign in December 2011. This flight will map \sim8% of the sky to achieve unprecedented sensitivity to the polarization signature of the gravitational wave background predicted by inflationary cosmology. The Spider mission will also serve as a proving ground for these detector technologies in preparation for a future satellite mission.
[20]  oai:arXiv.org:1102.0559  [pdf] - 1051855
Spider Optimization II: Optical, Magnetic and Foreground Effects
Comments: submitted to APJ, 15 pages, 12 figures
Submitted: 2011-02-02
Spider is a balloon-borne instrument designed to map the polarization of the cosmic microwave background (CMB) with degree-scale resolution over a large fraction of the sky. Spider's main goal is to measure the amplitude of primordial gravitational waves through their imprint on the polarization of the CMB if the tensor-to-scalar ratio, r, is greater than 0.03. To achieve this goal, instrumental systematic errors must be controlled with unprecedented accuracy. Here, we build on previous work to use simulations of Spider observations to examine the impact of several systematic effects that have been characterized through testing and modeling of various instrument components. In particular, we investigate the impact of the non-ideal spectral response of the half-wave plates, coupling between focal plane components and the Earth's magnetic field, and beam mismatches and asymmetries. We also present a model of diffuse polarized foreground emission based on a three-dimensional model of the Galactic magnetic field and dust, and study the interaction of this foreground emission with our observation strategy and instrumental effects. We find that the expected level of foreground and systematic contamination is sufficiently low for Spider to achieve its science goals.
[21]  oai:arXiv.org:1011.2757  [pdf] - 1041909
The Mass-Radius(-Rotation?) Relation for Low-Mass Stars
Comments: Accepted to ApJ; 21 pages, 10 figures, 8 tables in emulateapj format. The full contents of Table 4 are included in the submission as tab4.txt
Submitted: 2010-11-11
The fundamental properties of low-mass stars are not as well understood as those of their more massive counterparts. The best method for constraining these properties, especially masses and radii, is to study eclipsing binary systems, but only a small number of late-type (M0 or later) systems have been identified and well-characterized to date. We present the discovery and characterization of six new M dwarf eclipsing binary systems. The twelve stars in these eclipsing systems have masses spanning 0.38-0.59 Msun and orbital periods of 0.6--1.7 days, with typical uncertainties of ~0.3% in mass and 0.5--2.0% in radius. Combined with six known systems with high-precision measurements, our results reveal an intriguing trend in the low-mass regime. For stars with M=0.35-0.80 Msun, components in short-period binary systems (P<1 day; 12 stars) have radii which are inflated by up to 10% (mean=4.8+/-1.0%) with respect to evolutionary models for low-mass main-sequence stars, whereas components in longer-period systems (>1.5 days; 12 stars) tend to have smaller radii (mean=1.7+/-0.7%). This trend supports the hypothesis that short-period systems are inflated by the influence of the close companion, most likely because they are tidally locked into very high rotation speeds that enhance activity and inhibit convection. In summary, very close binary systems are not representative of typical M dwarfs, but our results for longer-period systems indicate that the evolutionary models are broadly valid in the M~0.35-0.80 Msun regime.
[22]  oai:arXiv.org:1006.3874  [pdf] - 934286
Modeling and characterization of the SPIDER half-wave plate
Comments:
Submitted: 2010-06-19
Spider is a balloon-borne array of six telescopes that will observe the Cosmic Microwave Background. The 2624 antenna-coupled bolometers in the instrument will make a polarization map of the CMB with approximately one-half degree resolution at 145 GHz. Polarization modulation is achieved via a cryogenic sapphire half-wave plate (HWP) skyward of the primary optic. We have measured millimeter-wave transmission spectra of the sapphire at room and cryogenic temperatures. The spectra are consistent with our physical optics model, and the data gives excellent measurements of the indices of A-cut sapphire. We have also taken preliminary spectra of the integrated HWP, optical system, and detectors in the prototype Spider receiver. We calculate the variation in response of the HWP between observing the CMB and foreground spectra, and estimate that it should not limit the Spider constraints on inflation.
[23]  oai:arXiv.org:gr-qc/0003115  [pdf] - 898898
Gauge Symmetry and Gravito-Electromagnetism
Comments: 29 pages no-figs
Submitted: 2000-03-31, last modified: 2000-09-22
A tensor description of perturbative Einsteinian gravity about an arbitrary background spacetime is developed. By analogy with the covariant laws of electromagnetism in spacetime, gravito-electromagnetic potentials and fields are defined to emulate electromagnetic gauge transformations under substitutions belonging to the gauge symmetry group of perturbative gravitation. These definitions have the advantage that on a flat background, with the aid of a covariantly constant timelike vector field, a subset of the linearised gravitational field equations can be written in a form that is fully analogous to Maxwell's equations (without awkward factors of 4 and extraneous tensor fields). It is shown how the remaining equations in the perturbed gravitational system restrict the time dependence of solutions to these equations and thereby prohibit the existence of propagating vector fields. The induced gravito-electromagnetic Lorentz force on a test particle is evaluated in terms of these fields together with the torque on a small gyroscope. It is concluded that the analogy of perturbative gravity to Maxwell's description of electromagnetism can be valuable for (quasi-)stationary gravitational phenomena but that the analogy has its limitations.