Normalized to: Tsaneva, V.
[1]
oai:arXiv.org:0805.3690 [pdf] - 12907
Detecting the B-mode Polarisation of the CMB with Clover
North, C. E.;
Johnson, B. R.;
Ade, P. A. R.;
Audley, M. D.;
Baines, C.;
Battye, R. A.;
Brown, M. L.;
Cabella, P.;
Calisse, P. G.;
Challinor, A. D.;
Duncan, W. D.;
Ferreira, P. G.;
Gear, W. K.;
Glowacka, D.;
Goldie, D. J.;
Grimes, P. K.;
Halpern, M.;
Haynes, V.;
Hilton, G. C.;
Irwin, K. D.;
Jones, M. E.;
Lasenby, A. N.;
Leahy, P. J.;
Leech, J.;
Maffei, B.;
Mauskopf, P.;
Melhuish, S. J.;
O'Dea, D.;
Parsley, S. M.;
Piccirillo, L.;
Pisano, G.;
Reintsema, C. D.;
Savini, G.;
Sudiwala, R.;
Sutton, D.;
Taylor, A. C.;
Teleberg, G.;
Titterington, D.;
Tsaneva, V.;
Tucker, C.;
Watson, R.;
Withington, S.;
Yassin, G.;
Zhang, J.
Submitted: 2008-05-23, last modified: 2008-06-03
We describe the objectives, design and predicted performance of Clover, which
is a ground-based experiment to measure the faint ``B-mode'' polarisation
pattern in the cosmic microwave background (CMB). To achieve this goal, clover
will make polarimetric observations of approximately 1000 deg^2 of the sky in
spectral bands centred on 97, 150 and 225 GHz. The observations will be made
with a two-mirror compact range antenna fed by profiled corrugated horns. The
telescope beam sizes for each band are 7.5, 5.5 and 5.5 arcmin, respectively.
The polarisation of the sky will be measured with a rotating half-wave plate
and stationary analyser, which will be an orthomode transducer. The sky
coverage combined with the angular resolution will allow us to measure the
angular power spectra between 20 < l < 1000. Each frequency band will employ
192 single polarisation, photon noise limited TES bolometers cooled to 100 mK.
The background-limited sensitivity of these detector arrays will allow us to
constrain the tensor-to-scalar ratio to 0.026 at 3sigma, assuming any polarised
foreground signals can be subtracted with minimal degradation to the 150 GHz
sensitivity. Systematic errors will be mitigated by modulating the polarisation
of the sky signals with the rotating half-wave plate, fast azimuth scans and
periodic telescope rotations about its boresight. The three spectral bands will
be divided into two separate but nearly identical instruments - one for 97 GHz
and another for 150 and 225 GHz. The two instruments will be sited on identical
three-axis mounts in the Atacama Desert in Chile near Pampa la Bola.
Observations are expected to begin in late 2009.
[2]
oai:arXiv.org:astro-ph/0608285 [pdf] - 84162
Prototype finline-coupled TES bolometers for CLOVER
Audley, Michael D.;
Barker, Robert W.;
Crane, Michael;
Dace, Roger;
Glowacka, Dorota;
Goldie, David J.;
Lasenby, Anthony N.;
Stevenson, Howard M.;
Tsaneva, Vassilka;
Withington, Stafford;
Grimes, Paul;
Johnson, Bradley;
Yassin, Ghassan;
Piccirillo, Lucio;
Pisano, Giampaolo;
Duncan, William D.;
Hilton, Gene C.;
Irwin, Kent D.;
Reintsema, Carl D.;
Halpern, Mark
Submitted: 2006-08-14
CLOVER is an experiment which aims to detect the signature of gravitational
waves from inflation by measuring the B-mode polarization of the cosmic
microwave background. CLOVER consists of three telescopes operating at 97, 150,
and 220 GHz. The 97-GHz telescope has 160 feedhorns in its focal plane while
the 150 and 220-GHz telescopes have 256 horns each. The horns are arranged in a
hexagonal array and feed a polarimeter which uses finline-coupled TES
bolometers as detectors. To detect the two polarizations the 97-GHz telescope
has 320 detectors while the 150 and 220-GHz telescopes have 512 detectors each.
To achieve the target NEPs (1.5, 2.5, and 4.5x10^-17 W/rtHz) the detectors are
cooled to 100 mK for the 97 and 150-GHz polarimeters and 230 mK for the 220-GHz
polarimeter. Each detector is fabricated as a single chip to ensure a 100%
operational focal plane. The detectors are contained in linear modules made of
copper which form split-block waveguides. The detector modules contain 16 or 20
detectors each for compatibility with the hexagonal arrays of horns in the
telescopes' focal planes. Each detector module contains a time-division SQUID
multiplexer to read out the detectors. Further amplification of the multiplexed
signals is provided by SQUID series arrays. The first prototype detectors for
CLOVER operate with a bath temperature of 230 mK and are used to validate the
detector design as well as the polarimeter technology. We describe the design
of the CLOVER detectors, detector blocks, and readout, and present preliminary
measurements of the prototype detectors performance.
[3]
oai:arXiv.org:astro-ph/0607067 [pdf] - 1463183
TES imaging array technology for CLOVER
Audley, Michael D.;
Barker, Robert W.;
Crane, Michael;
Dace, Roger;
Glowacka, Dorota;
Goldie, David J.;
Lasenby, Anthony N.;
Stevenson, Howard M.;
Tsaneva, Vassilka;
Withington, Stafford;
Grimes, Paul;
Johnson, Bradley;
Yassin, Ghassan;
Piccirillo, Lucio;
Pisano, Giampaolo;
Duncan, William D.;
Hilton, Gene C.;
Irwin, Kent D.;
Reintsema, Carl D.;
Halpern, Mark
Submitted: 2006-07-05
CLOVER is an experiment which aims to detect the signature of gravitational
waves from inflation by measuring the B-mode polarization of the cosmic
microwave background. CLOVER consists of three telescopes operating at 97, 150,
and 220 GHz. The 97-GHz telescope has 160 horns in its focal plane while the
150 and 220-GHz telescopes have 256 horns each. The horns are arranged in a
hexagonal array and feed a polarimeter which uses finline-coupled TES
bolometers as detectors. To detect the two polarizations the 97-GHz telescope
has 320 detectors while the 150 and 220-GHz telescopes have 512 detectors each.
To achieve the required NEPs the detectors are cooled to 100 mK for the 97 and
150-GHz polarimeters and 230 mK for the 220-GHz polarimeter. Each detector is
fabricated as a single chip to guarantee fully functioning focal planes. The
detectors are contained in linear modules made of copper which form split-block
waveguides. The detector modules contain 16 or 20 detectors each for
compatibility with the hexagonal arrays of horns in the telescopes' focal
planes. Each detector module contains a time-division SQUID multiplexer to read
out the detectors. Further amplification of the multiplexed signals is provided
by SQUID series arrays. The first prototype detectors for CLOVER operate with a
bath temperature of 230 mK and are used to validate the detector design as well
as the polarimeter technology. We describe the design of the CLOVER detectors,
detector blocks, and readout, and give an update on the detector development.