Normalized to: Triou, H.
[1]
oai:arXiv.org:1910.05061 [pdf] - 2005532
Simulations of the SVOM/ECLAIRs Dynamic Background: A fast, accurate and
general approach for wide-field hard X-ray instruments
Mate, Sujay;
Bouchet, Laurent;
Atteia, Jean-Luc;
Claret, Arnaud;
Cordier, Bertrand;
Dagoneau, Nicolas;
Godet, Olivier;
Gros, Aleksandra;
Schanne, Stéphane;
Triou, Henri
Submitted: 2019-10-11
The Space Variable Object Monitor (SVOM) is a forthcoming Chinese - French
astrophysics space mission dedicated to the study of Gamma-ray bursts and
high-energy transients. ECLAIRs, a wide-field hard X-ray coded mask imager, is
the leading instrument for the transient detection and their first
localisation. The sensitivity of such instruments is usually limited by the
background, either of instrumental or astrophysical origin. Detailed
estimations of the background are obtained by simulating the interaction of
particles with the matter using, in the present case, the GEANT4 Monte-Carlo
toolkit. However, this is a time consuming process, especially when it is
needed to carry out all possible geometrical and orbital configurations.
Instead, we present a much faster method that allows computing the background
in either a static or dynamic (time dependent) way. The method is based on the
preliminary calculation of a large particle database using the GEANT4 toolkit
followed by a selection process based on the incoming direction and energy of
the particles. This approach is as accurate as direct Monte-Carlo methods,
while it reduces the computation time by a factor of $10^3 - 10^4$ for our
application. We apply this method to compute the SVOM/ECLAIRs dynamic
background.
[2]
oai:arXiv.org:1909.09015 [pdf] - 1964273
Designing large pixelated CdTe detection planes for hard X-ray
transients detection
Lacombe, K.;
Amoros, C.;
Atteia, J. -L.;
Bajat, A.;
Bouchet, L.;
Dezalay, J. -P.;
Guillemot, P.;
Houret, B.;
Lebrun, F.;
Mate, S.;
Pons, R.;
Triou, H.;
Waegebaert, V.
Submitted: 2019-09-19
We discuss the need for very large detection planes for the detection of hard
X-ray transients in the multi-messenger era that started with the
quasi-simultaneous detection of GRB~170817A by \textit{Fermi}/GBM and
\textit{INTEGRAL}/SPI on one hand and the gravitational waves event GW 170817,
detected by the LVC collaboration, on the other hand. Then, we present a brief
survey of current and future instruments and their expected sensitivity,
pointing the fact that the gain in the number of GRBs is achieved by future
projects thanks to their larger field of view rather than to their larger
effective area. Based on our experience with \textit{SVOM}/ECLAIRs, we then
address various problems associated with the realization of very large
detection planes (\mbox{$\ge 1 \mathrm m^{2}$}), and we demonstrate that CdTe
detectors are well suited for this task. We conclude with a discussion of some
key parameters that must be taken into account in the realization of
instruments based on these detectors. We hope that this paper will motivate the
elaboration of detailed proposals of large area wide-field hard X-ray monitors
that will be crucially needed in the next decade.
[3]
oai:arXiv.org:1406.7759 [pdf] - 1215301
The X-/Gamma-ray camera ECLAIRs for the Gammay-ray burst mission SVOM
Godet, O.;
Nasser, G.;
Atteia, J. -L.;
Cordier, B.;
Mandrou, P.;
Barret, D.;
Triou, H.;
Pons, R.;
Amoros, C.;
Bordon, S.;
Gevin, O.;
Gonzalez, F.;
Götz, D.;
Gros, A.;
Houret, B.;
Lachaud, C.;
Lacombe, K.;
Marty, W.;
Mercier, K.;
Rambaud, D.;
Ramon, P.;
Rouaix, G.;
Schanne, S.;
Waegebaert, V
Submitted: 2014-06-30
We present ECLAIRs, the Gamma-ray burst (GRB) trigger camera to fly on-board
the Chinese-French mission SVOM. ECLAIRs is a wide-field ($\sim 2$\,sr) coded
mask camera with a mask transparency of 40\% and a 1024 $\mathrm{cm}^2$
detection plane coupled to a data processing unit, so-called UGTS, which is in
charge of locating GRBs in near real time thanks to image and rate triggers. We
present the instrument science requirements and how the design of ECLAIRs has
been optimized to increase its sensitivity to high-redshift GRBs and
low-luminosity GRBs in the local Universe, by having a low-energy threshold of
4 keV. The total spectral coverage ranges from 4 to 150 keV. ECLAIRs is
expected to detect $\sim 200$ GRBs of all types during the nominal 3 year
mission lifetime.
To reach a 4 keV low-energy threshold, the ECLAIRs detection plane is paved
with 6400 $4\times 4~\mathrm{mm}^2$ and 1 mm-thick Schottky CdTe detectors. The
detectors are grouped by 32, in 8x4 matrices read by a low-noise ASIC, forming
elementary modules called XRDPIX. In this paper, we also present our current
efforts to investigate the performance of these modules with their front-end
electronics when illuminated by charged particles and/or photons using
radioactive sources. All measurements are made in different instrument
configurations in vacuum and with a nominal in-flight detector temperature of
$-20^\circ$C. This work will enable us to choose the in-flight configuration
that will make the best compromise between the science performance and the
in-flight operability of ECLAIRs. We will show some highlights of this work.
[4]
oai:arXiv.org:1005.5073 [pdf] - 1032794
In-flight calibration of the Herschel-SPIRE instrument
Swinyard, B. M.;
Ade, P.;
Baluteau, J-P.;
Aussel, H.;
Barlow, M. J.;
Bendo, G. J.;
Benielli, D.;
Bock, J.;
Brisbin, D.;
Conley, A.;
Conversi, L.;
Dowell, A.;
Dowell, D.;
Ferlet, M.;
Fulton, T.;
Glenn, J.;
Glauser, A.;
Griffin, D.;
Griffin, M.;
Guest, S.;
Imhof, P.;
Isaak, K.;
Jones, S.;
King, K.;
Leeks, S.;
Levenson, L.;
Lim, T. L.;
Lu, N.;
Makiwa, G.;
Naylor, D.;
Nguyen, H.;
Oliver, S.;
Panuzzo, P.;
Papageorgiou, A.;
Pearson, C.;
Pohlen, M.;
Polehampton, E.;
Pouliquen, D.;
Rigopoulou, D.;
Ronayette, S.;
Roussel, H.;
Rykala, A.;
Savini, G.;
Schulz, B.;
Schwartz, A.;
Shupe, D.;
Sibthorpe, B.;
Sidher, S.;
Smith, A. J.;
Spencer, L.;
Trichas, M.;
Triou, H.;
Valtchanov, I.;
Wesson, R.;
Woodcraft, A.;
Xu, C. K.;
Zemcov, M.;
Zhang, L.
Submitted: 2010-05-27
SPIRE, the Spectral and Photometric Imaging Receiver, is the Herschel Space
Observatory's submillimetre camera and spectrometer. It contains a three-band
imaging photometer operating at 250, 350 and 500 {\mu}m, and an imaging Fourier
transform spectrometer (FTS) covering 194-671 {\mu}m (447-1550 GHz). In this
paper we describe the initial approach taken to the absolute calibration of the
SPIRE instrument using a combination of the emission from the Herschel
telescope itself and the modelled continuum emission from solar system objects
and other astronomical targets. We present the photometric, spectroscopic and
spatial accuracy that is obtainable in data processed through the "standard"
pipelines. The overall photometric accuracy at this stage of the mission is
estimated as 15% for the photometer and between 15 and 50% for the
spectrometer. However, there remain issues with the photometric accuracy of the
spectra of low flux sources in the longest wavelength part of the SPIRE
spectrometer band. The spectrometer wavelength accuracy is determined to be
better than 1/10th of the line FWHM. The astrometric accuracy in SPIRE maps is
found to be 2 arcsec when the latest calibration data are used. The photometric
calibration of the SPIRE instrument is currently determined by a combination of
uncertainties in the model spectra of the astronomical standards and the data
processing methods employed for map and spectrum calibration. Improvements in
processing techniques and a better understanding of the instrument performance
will lead to the final calibration accuracy of SPIRE being determined only by
uncertainties in the models of astronomical standards.
[5]
oai:arXiv.org:1005.5123 [pdf] - 1032799
The Herschel-SPIRE instrument and its in-flight performance
Griffin, M. J.;
Abergel, A.;
Abreu, A.;
Ade, P. A. R.;
André, P.;
Augueres, J. -L.;
Babbedge, T.;
Bae, Y.;
Baillie, T.;
Baluteau, J. -P.;
Barlow, M. J.;
Bendo, G.;
Benielli, D.;
Bock, J. J.;
Bonhomme, P.;
Brisbin, D.;
Brockley-Blatt, C.;
Caldwell, M.;
Cara, C.;
Castro-Rodriguez, N.;
Cerulli, R.;
Chanial, P.;
Chen, S.;
Clark, E.;
Clements, D. L.;
Clerc, L.;
Coker, J.;
Communal, D.;
Conversi, L.;
Cox, P.;
Crumb, D.;
Cunningham, C.;
Daly, F.;
Davis, G. R.;
De Antoni, P.;
Delderfield, J.;
Devin, N.;
Di Giorgio, A.;
Didschuns, I.;
Dohlen, K.;
Donati, M.;
Dowell, A.;
Dowell, C. D.;
Duband, L.;
Dumaye, L.;
Emery, R. J.;
Ferlet, M.;
Ferrand, D.;
Fontignie, J.;
Fox, M.;
Franceschini, A.;
Frerking, M.;
Fulton, T.;
Garcia, J.;
Gastaud, R.;
Gear, W. K.;
Glenn, J.;
Goizel, A.;
Griffin, D. K.;
Grundy, T.;
Guest, S.;
Guillemet, L.;
Hargrave, P. C.;
Harwit, M.;
Hastings, P.;
Hatziminaoglou, E.;
Herman, M.;
Hinde, B.;
Hristov, V.;
Huang, M.;
Imhof, P.;
Isaak, K. J.;
Israelsson, U.;
Ivison, R. J.;
Jennings, D.;
Kiernan, B.;
King, K. J.;
Lange, A. E.;
Latter, W.;
Laurent, G.;
Laurent, P.;
Leeks, S. J.;
Lellouch, E.;
Levenson, L.;
Li, B.;
Li, J.;
Lilienthal, J.;
Lim, T.;
Liu, J.;
Lu, N.;
Madden, S.;
Mainetti, G.;
Marliani, P.;
McKay, D.;
Mercier, K.;
Molinari, S.;
Morris, H.;
Moseley, H.;
Mulder, J.;
Mur, M.;
Naylor, D. A.;
Nguyen, H.;
O'Halloran, B.;
Oliver, S.;
Olofsson, G.;
Olofsson, H. -G.;
Orfei, R.;
Page, M. J.;
Pain, I.;
Panuzzo, P.;
Papageorgiou, A.;
Parks, G.;
Parr-Burman, P.;
Pearce, A.;
Pearson, C.;
Pérez-Fournon, I.;
Pinsard, F.;
Pisano, G.;
Podosek, J.;
Pohlen, M.;
Polehampton, E. T.;
Pouliquen, D.;
Rigopoulou, D.;
Rizzo, D.;
Roseboom, I. G.;
Roussel, H.;
Rowan-Robinson, M.;
Rownd, B.;
Saraceno, P.;
Sauvage, M.;
Savage, R.;
Savini, G.;
Sawyer, E.;
Scharmberg, C.;
Schmitt, D.;
Schneider, N.;
Schulz, B.;
Schwartz, A.;
Shafer, R.;
Shupe, D. L.;
Sibthorpe, B.;
Sidher, S.;
Smith, A.;
Smith, A. J.;
Smith, D.;
Spencer, L.;
Stobie, B.;
Sudiwala, R.;
Sukhatme, K.;
Surace, C.;
Stevens, J. A.;
Swinyard, B. M.;
Trichas, M.;
Tourette, T.;
Triou, H.;
Tseng, S.;
Tucker, C.;
Turner, A.;
Vaccari, M.;
Valtchanov, I.;
Vigroux, L.;
Virique, E.;
Voellmer, G.;
Walker, H.;
Ward, R.;
Waskett, T.;
Weilert, M.;
Wesson, R.;
White, G. J.;
Whitehouse, N.;
Wilson, C. D.;
Winter, B.;
Woodcraft, A. L.;
Wright, G. S.;
Xu, C. K.;
Zavagno, A.;
Zemcov, M.;
Zhang, L.;
Zonca, E.
Submitted: 2010-05-27
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space
Observatory`s submillimetre camera and spectrometer. It contains a three-band
imaging photometer operating at 250, 350 and 500 microns, and an imaging
Fourier Transform Spectrometer (FTS) which covers simultaneously its whole
operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are
arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a
field of view of 4' x 8', observed simultaneously in the three spectral bands.
Its main operating mode is scan-mapping, whereby the field of view is scanned
across the sky to achieve full spatial sampling and to cover large areas if
desired. The spectrometer has an approximately circular field of view with a
diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25
GHz by changing the stroke length of the FTS scan mirror. Its main operating
mode involves a fixed telescope pointing with multiple scans of the FTS mirror
to acquire spectral data. For extended source measurements, multiple position
offsets are implemented by means of an internal beam steering mirror to achieve
the desired spatial sampling and by rastering of the telescope pointing to map
areas larger than the field of view. The SPIRE instrument consists of a cold
focal plane unit located inside the Herschel cryostat and warm electronics
units, located on the spacecraft Service Module, for instrument control and
data handling. Science data are transmitted to Earth with no on-board data
compression, and processed by automatic pipelines to produce calibrated science
products. The in-flight performance of the instrument matches or exceeds
predictions based on pre-launch testing and modelling: the photometer
sensitivity is comparable to or slightly better than estimated pre-launch, and
the spectrometer sensitivity is also better by a factor of 1.5-2.