Normalized to: Trangsrud, A.
[1]
oai:arXiv.org:2002.05771 [pdf] - 2080996
Particle response of antenna-coupled TES arrays: results from SPIDER and
the lab
Osherson, B.;
Filippini, J. P.;
Fu, J.;
Gramillano, R. V.;
Gualtieri, R.;
Shaw, E. C.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Dore, O.;
Fraisse, A. A.;
Gambrel, A. E.;
Gandilo, N. N.;
Gudmundsson, J. E.;
Halpern, M.;
Hartley, J.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kermish, Z. D.;
Mason, P. V.;
Megerian, K.;
Moncelsi, L.;
Morford, T. A.;
Nagy, J. M.;
Netterfield, C. B.;
Padilla, I. L.;
Rahlin, A. S.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Weber, A. C.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2020-02-13
Future mm-wave and sub-mm space missions will employ large arrays of
multiplexed Transition Edge Sensor (TES) bolometers. Such instruments must
contend with the high flux of cosmic rays beyond our atmosphere that induce
"glitches" in bolometer data, which posed a challenge to data analysis from the
Planck bolometers. Future instruments will face the additional challenges of
shared substrate wafers and multiplexed readout wiring. In this work we explore
the susceptibility of modern TES arrays to the cosmic ray environment of space
using two data sets: the 2015 long-duration balloon flight of the SPIDER cosmic
microwave background polarimeter, and a laboratory exposure of SPIDER flight
hardware to radioactive sources. We find manageable glitch rates and short
glitch durations, leading to minimal effect on SPIDER analysis. We constrain
energy propagation within the substrate through a study of multi-detector
coincidences, and give a preliminary look at pulse shapes in laboratory data.
[2]
oai:arXiv.org:1908.07495 [pdf] - 1945993
PICO: Probe of Inflation and Cosmic Origins
Hanany, S.;
Alvarez, M.;
Artis, E.;
Ashton, P.;
Aumont, J.;
Aurlien, R.;
Banerji, R.;
Barreiro, R. B.;
Bartlett, J. G.;
Basak, S.;
Battaglia, N.;
Bock, J.;
Boddy, K. K.;
Bonato, M.;
Borrill, J.;
Bouchet, F.;
Boulanger, F.;
Burkhart, B.;
Chluba, J.;
Chuss, D.;
Clark, S.;
Cooperrider, J.;
Crill, B. P.;
De Zotti, G.;
Delabrouille, J.;
Di Valentino, E.;
Didier, J.;
Dore, O.;
Eriksen, H. K.;
Errard, J.;
Essinger-Hileman, T.;
Feeney, S.;
Filippini, J.;
Fissel, L.;
Flauger, R.;
Fuskeland, U.;
Gluscevic, V.;
Gorski, K. M.;
Green, D.;
Hensley, B.;
Herranz, D.;
Hill, J. C.;
Hivon, E.;
Hlozek, R.;
Hubmayr, J.;
Johnson, B. R.;
Jones, W.;
Jones, T.;
Knox, L.;
Kogut, A.;
Lopez-Caniego, M.;
Lawrence, C.;
Lazarian, A.;
Li, Z.;
Madhavacheril, M.;
Melin, J. B.;
Meyers, J.;
Murray, C.;
Negrello, M.;
Novak, G.;
O'Brient, R.;
Paine, C.;
Pearson, T.;
Pogosian, L.;
Pryke, C.;
Puglisi, G.;
Remazeilles, M.;
Rocha, G.;
Schmittfull, M.;
Scott, D.;
Shirron, P.;
Stephens, I.;
Sutin, B.;
Tomasi, M.;
Trangsrud, A.;
van Engelen, A.;
Vansyngel, F.;
Wehus, I. K.;
Wen, Q.;
Xu, S.;
Young, K.;
Zonca, A.
Submitted: 2019-08-20
The Probe of Inflation and Cosmic Origins (PICO) is a proposed probe-scale
space mission consisting of an imaging polarimeter operating in frequency bands
between 20 and 800 GHz. We describe the science achievable by PICO, which has
sensitivity equivalent to more than 3300 Planck missions, the technical
implementation, the schedule and cost.
[3]
oai:arXiv.org:1902.10541 [pdf] - 1842579
PICO: Probe of Inflation and Cosmic Origins
Hanany, Shaul;
Alvarez, Marcelo;
Artis, Emmanuel;
Ashton, Peter;
Aumont, Jonathan;
Aurlien, Ragnhild;
Banerji, Ranajoy;
Barreiro, R. Belen;
Bartlett, James G.;
Basak, Soumen;
Battaglia, Nick;
Bock, Jamie;
Boddy, Kimberly K.;
Bonato, Matteo;
Borrill, Julian;
Bouchet, François;
Boulanger, François;
Burkhart, Blakesley;
Chluba, Jens;
Chuss, David;
Clark, Susan E.;
Cooperrider, Joelle;
Crill, Brendan P.;
De Zotti, Gianfranco;
Delabrouille, Jacques;
Di Valentino, Eleonora;
Didier, Joy;
Doré, Olivier;
Eriksen, Hans K.;
Errard, Josquin;
Essinger-Hileman, Tom;
Feeney, Stephen;
Filippini, Jeffrey;
Fissel, Laura;
Flauger, Raphael;
Fuskeland, Unni;
Gluscevic, Vera;
Gorski, Krzysztof M.;
Green, Dan;
Hensley, Brandon;
Herranz, Diego;
Hill, J. Colin;
Hivon, Eric;
Hložek, Renée;
Hubmayr, Johannes;
Johnson, Bradley R.;
Jones, William;
Jones, Terry;
Knox, Lloyd;
Kogut, Al;
López-Caniego, Marcos;
Lawrence, Charles;
Lazarian, Alex;
Li, Zack;
Madhavacheril, Mathew;
Melin, Jean-Baptiste;
Meyers, Joel;
Murray, Calum;
Negrello, Mattia;
Novak, Giles;
O'Brient, Roger;
Paine, Christopher;
Pearson, Tim;
Pogosian, Levon;
Pryke, Clem;
Puglisi, Giuseppe;
Remazeilles, Mathieu;
Rocha, Graca;
Schmittfull, Marcel;
Scott, Douglas;
Shirron, Peter;
Stephens, Ian;
Sutin, Brian;
Tomasi, Maurizio;
Trangsrud, Amy;
van Engelen, Alexander;
Vansyngel, Flavien;
Wehus, Ingunn K.;
Wen, Qi;
Xu, Siyao;
Young, Karl;
Zonca, Andrea
Submitted: 2019-02-26, last modified: 2019-03-05
The Probe of Inflation and Cosmic Origins (PICO) is an imaging polarimeter
that will scan the sky for 5 years in 21 frequency bands spread between 21 and
799 GHz. It will produce full-sky surveys of intensity and polarization with a
final combined-map noise level of 0.87 $\mu$K arcmin for the required
specifications, equivalent to 3300 Planck missions, and with our current
best-estimate would have a noise level of 0.61 $\mu$K arcmin (6400 Planck
missions). PICO will either determine the energy scale of inflation by
detecting the tensor to scalar ratio at a level $r=5\times 10^{-4}~(5\sigma)$,
or will rule out with more than $5\sigma$ all inflation models for which the
characteristic scale in the potential is the Planck scale. With LSST's data it
could rule out all models of slow-roll inflation. PICO will detect the sum of
neutrino masses at $>4\sigma$, constrain the effective number of light particle
species with $\Delta N_{\rm eff}<0.06~(2\sigma)$, and elucidate processes
affecting the evolution of cosmic structures by measuring the optical depth to
reionization with errors limited by cosmic variance and by constraining the
evolution of the amplitude of linear fluctuations $\sigma_{8}(z)$ with
sub-percent accuracy. Cross-correlating PICO's map of the thermal
Sunyaev-Zeldovich effect with LSST's gold sample of galaxies will precisely
trace the evolution of thermal pressure with $z$. PICO's maps of the Milky Way
will be used to determine the make up of galactic dust and the role of magnetic
fields in star formation efficiency. With 21 full sky legacy maps in intensity
and polarization, which cannot be obtained in any other way, the mission will
enrich many areas of astrophysics. PICO is the only single-platform instrument
with the combination of sensitivity, angular resolution, frequency bands, and
control of systematic effects that can deliver this compelling, timely, and
broad science.
[4]
oai:arXiv.org:1808.01368 [pdf] - 1728073
PICO - the probe of inflation and cosmic origins
Sutin, Brian;
Alvarez, Marcelo;
Battaglia, Nicholas;
Bock, Jamie;
Bonato, Matteo;
Borrill, Julian;
Chuss, David T.;
Cooperrider, Joelle;
Crill, Brendan;
Delabrouille, Jacques;
Devlin, Mark;
Essinger-Hileman, Thomas;
Fissel, Laura;
Flauger, Raphael;
Gorski, Krzysztof;
Green, Daniel;
Hanany, Shaul;
Hubmayr, Johannes;
Johnson, Bradley;
Jones, William C.;
Knox, Lloyd;
Kogut, Alan;
Lawrence, Charles;
McMahon, Jeff;
Matsumura, Tomotake;
Negrello, Mattia;
O'Brient, Roger;
Paine, Christopher;
Pryke, Clement;
Shirron, Peter;
Trangsrud, Amy;
Wen, Qi;
Young, Karl;
de Zotti, Gianfranco
Submitted: 2018-08-03
The Probe of Inflation and Cosmic Origins (PICO) is a NASA-funded study of a
Probe-class mission concept. The top-level science objectives are to probe the
physics of the Big Bang by measuring or constraining the energy scale of
inflation, probe fundamental physics by measuring the number of light particles
in the Universe and the sum of neutrino masses, to measure the reionization
history of the Universe, and to understand the mechanisms driving the cosmic
star formation history, and the physics of the galactic magnetic field. PICO
would have multiple frequency bands between 21 and 799 GHz, and would survey
the entire sky, producing maps of the polarization of the cosmic microwave
background radiation, of galactic dust, of synchrotron radiation, and of
various populations of point sources. Several instrument configurations,
optical systems, cooling architectures, and detector and readout technologies
have been and continue to be considered in the development of the mission
concept. We will present a snapshot of the baseline mission concept currently
under development.
[5]
oai:arXiv.org:1808.01369 [pdf] - 1728074
Optical Design of PICO, a Concept for a Space Mission to Probe Inflation
and Cosmic Origins
Young, Karl;
Alvarez, Marcelo;
Battaglia, Nicholas;
Bock, Jamie;
Borrill, Julian;
Chuss, David;
Crill, Brendan;
Delabrouille, Jacques;
Devlin, Mark;
Fissel, Laura;
Flauger, Raphael;
Green, Daniel;
Gorski, Kris;
Hanany, Shaul;
Hills, Richard;
Hubmayr, Johannes;
Johnson, Bradley;
Jones, Bill;
Knox, Lloyd;
Kogut, Al;
Lawrence, Charles;
Matsumura, Tomotake;
McGuire, Jim;
McMahon, Jeff;
O'Brient, Roger;
Pryke, Clem;
Sutin, Brian M.;
Tan, Xin Zhi;
Trangsrud, Amy;
Wen, Qi;
de Zotti, Gianfranco
Submitted: 2018-08-03
The Probe of Inflation and Cosmic Origins (PICO) is a probe-class mission
concept currently under study by NASA. PICO will probe the physics of the Big
Bang and the energy scale of inflation, constrain the sum of neutrino masses,
measure the growth of structures in the universe, and constrain its
reionization history by making full sky maps of the cosmic microwave background
with sensitivity 80 times higher than the Planck space mission. With bands at
21-799 GHz and arcmin resolution at the highest frequencies, PICO will make
polarization maps of Galactic synchrotron and dust emission to observe the role
of magnetic fields in Milky Way's evolution and star formation. We discuss
PICO's optical system, focal plane, and give current best case noise estimates.
The optical design is a two-reflector optimized open-Dragone design with a cold
aperture stop. It gives a diffraction limited field of view (DLFOV) with
throughput of 910 square cm sr at 21 GHz. The large 82 square degree DLFOV
hosts 12,996 transition edge sensor bolometers distributed in 21 frequency
bands and maintained at 0.1 K. We use focal plane technologies that are
currently implemented on operating CMB instruments including three-color
multi-chroic pixels and multiplexed readouts. To our knowledge, this is the
first use of an open-Dragone design for mm-wave astrophysical observations, and
the only monolithic CMB instrument to have such a broad frequency coverage.
With current best case estimate polarization depth of 0.65 microK(CMB}-arcmin
over the entire sky, PICO is the most sensitive CMB instrument designed to
date.
[6]
oai:arXiv.org:1711.10596 [pdf] - 1783704
SPIDER: CMB polarimetry from the edge of space
Gualtieri, R.;
Filippini, J. P.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bergman, A. S.;
Bihary, R.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Doré, O.;
Duivenvoorden, A. J.;
Eriksen, H. K.;
Farhang, M.;
Fissel, L. M.;
Fraisse, A. A.;
Freese, K.;
Galloway, M.;
Gambrel, A. E.;
Gandilo, N. N.;
Ganga, K.;
Gramillano, R. V.;
Gudmundsson, J. E.;
Halpern, M.;
Hartley, J.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Huang, Z.;
Irwin, K. D.;
Jones, W. C.;
Kuo, C. L.;
Kermish, Z. D.;
Li, S.;
Mason, P. V.;
Megerian, K.;
Moncelsi, L.;
Morford, T. A.;
Nagy, J. M.;
Netterfield, C. B.;
Nolta, M.;
Osherson, B.;
Padilla, I. L.;
Racine, B.;
Rahlin, A. S.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Ruud, T. M.;
Shariff, J. A.;
Soler, J. D.;
Song, X.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
van der List, J. F.;
Weber, A. C.;
Wehus, I. K.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2017-11-28
SPIDER is a balloon-borne instrument designed to map the polarization of the
millimeter-wave sky at large angular scales. SPIDER targets the B-mode
signature of primordial gravitational waves in the cosmic microwave background
(CMB), with a focus on mapping a large sky area with high fidelity at multiple
frequencies. SPIDER's first longduration balloon (LDB) flight in January 2015
deployed a total of 2400 antenna-coupled Transition Edge Sensors (TESs) at 90
GHz and 150 GHz. In this work we review the design and in-flight performance of
the SPIDER instrument, with a particular focus on the measured performance of
the detectors and instrument in a space-like loading and radiation environment.
SPIDER's second flight in December 2018 will incorporate payload upgrades and
new receivers to map the sky at 285 GHz, providing valuable information for
cleaning polarized dust emission from CMB maps.
[7]
oai:arXiv.org:1711.04169 [pdf] - 1755845
280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2
Suborbital Polarimeter
Bergman, A. S.;
Ade, P. A. R.;
Akers, S.;
Amiri, M.;
Austermann, J. A.;
Beall, J. A.;
Becker, D. T.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Domagalski, R. S;
Doré, O.;
Duff, S. M.;
Duivenvoorden, A. J.;
Eriksen, H. K.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Fraisse, A. A.;
Freese, K.;
Galloway, M.;
Gambrel, A. E.;
Gandilo, N. N.;
Ganga, K.;
Grigorian, A.;
Gualtieri, R.;
Gudmundsson, J. E.;
Halpern, M.;
Hartley, J.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Huang, Z.;
Hubmayr, J.;
Irwin, K. D.;
Jones, W. C.;
Khan, A.;
Kuo, C. L.;
Kermish, Z. D.;
Li, S.;
Mason, P. V.;
Megerian, K.;
Moncelsi, L.;
Morford, T. A.;
Nagy, J. M.;
Netterfield, C. B.;
Nolta, M.;
Osherson, B.;
Padilla, I. L.;
Racine, B.;
Rahlin, A. S.;
Redmond, S.;
Reintsema, C.;
Romualdez, L. J.;
Ruhl, J. E.;
Runyan, M. C.;
Ruud, T. M.;
Shariff, J. A.;
Shaw, E. C.;
Shiu, C.;
Soler, J. D.;
Song, X.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Ullom, J.;
van der List, J. F.;
Van Lanen, J.;
Vissers, M. R.;
Weber, A. C.;
Wehus, I. K.;
Wen, S.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2017-11-11, last modified: 2017-11-22
We describe the construction and characterization of the 280 GHz bolometric
focal plane units (FPUs) to be deployed on the second flight of the
balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary
science goal of detecting or placing an upper limit on the amplitude of the
primordial gravitational wave signature in the cosmic microwave background
(CMB) by constraining the B-mode contamination in the CMB from Galactic dust
emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated
silicon feedhorns coupled to an array of aluminum-manganese transition-edge
sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the
three 280 GHz FPUs contain 1,530 polarization sensitive bolometers (765 spatial
pixels) optimized for the low loading environment in flight and read out by
time-division SQUID multiplexing. In this paper we describe the mechanical,
thermal, and magnetic shielding architecture of the focal planes and present
cryogenic measurements which characterize yield and the uniformity of several
bolometer parameters. The assembled FPUs have high yields, with one array as
high as 95% including defects from wiring and readout. We demonstrate high
uniformity in device parameters, finding the median saturation power for each
TES array to be ~3 pW at 300 mK with a less than 6% variation across each array
at one standard deviation. These focal planes will be deployed alongside the 95
and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo
Station in Antarctica in December 2018.
[8]
oai:arXiv.org:1704.00215 [pdf] - 1582291
A New Limit on CMB Circular Polarization from SPIDER
Nagy, J. M.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bergman, A. S.;
Bihary, R.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Dore, O.;
Duivenvoorden, A. J.;
Eriksen, H. K.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Fraisse, A. A.;
Freese, K.;
Galloway, M.;
Gambrel, A. E.;
Gandilo, N. N.;
Ganga, K.;
Gudmundsson, J. E.;
Halpern, M.;
Hartley, J.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Huang, Z.;
Irwin, K. D.;
Jones, W. C.;
Kuo, C. L.;
Kermish, Z. D.;
Li, S.;
Mason, P. V.;
Megerian, K.;
Moncelsi, L.;
Morford, T. A.;
Netterfield, C. B.;
Nolta, M.;
Padilla, I. L.;
Racine, B.;
Rahlin, A. S.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Ruud, T. M.;
Shariff, J. A.;
Soler, J. D.;
Song, X.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
van der List, J. F.;
Weber, A. C.;
Wehus, I. K.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2017-04-01, last modified: 2017-08-11
We present a new upper limit on CMB circular polarization from the 2015
flight of SPIDER, a balloon-borne telescope designed to search for $B$-mode
linear polarization from cosmic inflation. Although the level of circular
polarization in the CMB is predicted to be very small, experimental limits
provide a valuable test of the underlying models. By exploiting the non-zero
circular-to-linear polarization coupling of the HWP polarization modulators,
data from SPIDER's 2015 Antarctic flight provide a constraint on Stokes $V$ at
95 and 150 GHz from $33<\ell<307$. No other limits exist over this full range
of angular scales, and SPIDER improves upon the previous limit by several
orders of magnitude, providing 95% C.L. constraints on $\ell
(\ell+1)C_{\ell}^{VV}/(2\pi)$ ranging from 141 $\mu K ^2$ to 255 $\mu K ^2$ at
150 GHz for a thermal CMB spectrum. As linear CMB polarization experiments
become increasingly sensitive, the techniques described in this paper can be
applied to obtain even stronger constraints on circular polarization.
[9]
oai:arXiv.org:1510.01771 [pdf] - 1337397
A cryogenic rotation stage with a large clear aperture for the half-wave
plates in the Spider instrument
Bryan, Sean;
Ade, Peter;
Amiri, Mandana;
Benton, Steven;
Bihary, Richard;
Bock, James;
Bond, J. Richard;
Chiang, H. Cynthia;
Contaldi, Carlo;
Crill, Brendan;
Dore, Olivier;
Elder, Benjamin;
Filippini, Jeffrey;
Fraisse, Aurelien;
Gambrel, Anne;
Gandilo, Natalie;
Gudmundsson, Jon;
Hasselfield, Matthew;
Halpern, Mark;
Hilton, Gene;
Holmes, Warren;
Hristov, Viktor;
Irwin, Kent;
Jones, William;
Kermish, Zigmund;
Lawrie, Craig;
MacTavish, Carrie;
Mason, Peter;
Megerian, Krikor;
Moncelsi, Lorenzo;
Montroy, Thomas;
Morford, Tracy;
Nagy, Johanna;
Netterfield, C. Barth;
Padilla, Ivan;
Rahlin, Alexandra S.;
Reintsema, Carl;
Riley, Daniel C.;
Ruhl, John;
Runyan, Marcus;
Saliwanchik, Benjamin;
Shariff, Jamil;
Soler, Juan;
Trangsrud, Amy;
Tucker, Carole;
Tucker, Rebecca;
Turner, Anthony;
Wen, Shyang;
Wiebe, Donald;
Young, Edward
Submitted: 2015-10-06, last modified: 2016-01-08
We describe the cryogenic half-wave plate rotation mechanisms built for and
used in Spider, a polarization-sensitive balloon-borne telescope array that
observed the Cosmic Microwave Background at 95 GHz and 150 GHz during a
stratospheric balloon flight from Antarctica in January 2015. The mechanisms
operate at liquid helium temperature in flight. A three-point contact design
keeps the mechanical bearings relatively small but allows for a large (305 mm)
diameter clear aperture. A worm gear driven by a cryogenic stepper motor allows
for precise positioning and prevents undesired rotation when the motors are
depowered. A custom-built optical encoder system monitors the bearing angle to
an absolute accuracy of +/- 0.1 degrees. The system performed well in Spider
during its successful 16 day flight.
[10]
oai:arXiv.org:1506.06953 [pdf] - 1275488
The Thermal Design, Characterization, and Performance of the SPIDER
Long-Duration Balloon Cryostat
Gudmundsson, J. E.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Crill, B. P.;
Doré, O.;
Filippini, J. P.;
Fraisse, A. A.;
Gambrel, A.;
Gandilo, N. N.;
Hasselfield, M.;
Halpern, M.;
Hilton, G. C.;
Holmes, W.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kermish, Z.;
MacTavish, C. J.;
Mason, P. V.;
Megerian, K.;
Moncelsi, L.;
Montroy, T. E.;
Morford, T. A.;
Nagy, J. M.;
Netterfield, C. B.;
Rahlin, A. S.;
Reintsema, C. D.;
Ruhl, J. E.;
Runyan, M. C.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Wiebe, D. V.;
Young, E.
Submitted: 2015-06-23, last modified: 2015-09-11
We describe the SPIDER flight cryostat, which is designed to cool six
millimeter-wavelength telescopes during an Antarctic long-duration balloon
flight. The cryostat, one of the largest to have flown on a stratospheric
payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6
K. Stainless steel capillaries facilitate a high flow impedance connection
between the main liquid helium tank and a smaller superfluid tank, allowing the
latter to operate at 1.6 K as long as there is liquid in the 4.2 K main tank.
Each telescope houses a closed cycle helium-3 adsorption refrigerator that
further cools the focal planes down to 300 mK. Liquid helium vapor from the
main tank is routed through heat exchangers that cool radiation shields,
providing negative thermal feedback. The system performed successfully during a
17 day flight in the 2014-2015 Antarctic summer. The cryostat had a total hold
time of 16.8 days, with 15.9 days occurring during flight.
[11]
oai:arXiv.org:1502.00619 [pdf] - 1300145
Antenna-coupled TES bolometers used in BICEP2, Keck array, and SPIDER
Ade, P. A. R.;
Aikin, R. W.;
Amiri, M.;
Barkats, D.;
Benton, S. J.;
Bischoff, C. A.;
Bock, J. J.;
Bonetti, J. A.;
Brevik, J. A.;
Buder, I.;
Bullock, E.;
Chattopadhyay, G.;
Davis, G.;
Day, P. K.;
Dowell, C. D.;
Duband, L.;
Filippini, J. P.;
Fliescher, S.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hristov, V.;
Hui, H.;
Irwin, K. D.;
Jones, W. C.;
Karkare, K. S.;
Kaufman, J. P.;
Keating, B. G.;
Kefeli, S.;
Kernasovskiy, S. A.;
Kovac, J. M.;
Kuo, C. L.;
Leduc, H. G.;
Leitch, E. M.;
Llombart, N.;
Lueker, M.;
Mason, P.;
Megerian, K.;
Moncelsi, L.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Orlando, A.;
Pryke, C.;
Rahlin, A. S.;
Reintsema, C. D.;
Richter, S.;
Runyan, M. C.;
Schwarz, R.;
Sheehy, C. D.;
Staniszewski, Z. K.;
Sudiwala, R. V.;
Teply, G. P.;
Tolan, J. E.;
Trangsrud, A.;
Tucker, R. S.;
Turner, A. D.;
Vieregg, A. G.;
Weber, A.;
Wiebe, D. V.;
Wilson, P.;
Wong, C. L.;
Yoon, K. W.;
Zmuidzinas, J.
Submitted: 2015-02-02
We have developed antenna-coupled transition-edge sensor (TES) bolometers for
a wide range of cosmic microwave background (CMB) polarimetry experiments,
including BICEP2, Keck Array, and the balloon borne SPIDER. These detectors
have reached maturity and this paper reports on their design principles,
overall performance, and key challenges associated with design and production.
Our detector arrays repeatedly produce spectral bands with 20%-30% bandwidth at
95, 150, or 220~GHz. The integrated antenna arrays synthesize symmetric
co-aligned beams with controlled side-lobe levels. Cross-polarized response on
boresight is typically ~0.5%, consistent with cross-talk in our multiplexed
readout system. End-to-end optical efficiencies in our cameras are routinely
35% or higher, with per detector sensitivities of NET~300 uKrts. Thanks to the
scalability of this design, we have deployed 2560 detectors as 1280 matched
pairs in Keck Array with a combined instantaneous sensitivity of ~9 uKrts, as
measured directly from CMB maps in the 2013 season. Similar arrays have
recently flown in the SPIDER instrument, and development of this technology is
ongoing.
[12]
oai:arXiv.org:1407.1883 [pdf] - 1215475
Attitude determination for balloon-borne experiments
Gandilo, N. N.;
Ade, P. A. R.;
Amiri, M.;
Angile, F. E.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Crill, B. P.;
Devlin, M. J.;
Dober, B.;
Dore, O. P.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Fraisse, A. A.;
Fukui, Y.;
Galitzki, N.;
Gambrel, A. E.;
Golwala, S.;
Gudmundsson, J. E.;
Halpern, M.;
Hasselfield, M.;
Hilton, G. C.;
Holmes, W. A.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kermish, Z. D.;
Klein, J.;
Korotkov, A. L.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Matthews, T. G.;
Megerian, K. G.;
Moncelsi, L.;
Morford, T. A.;
Mroczkowski, T. K.;
Nagy, J. M.;
Netterfield, C. B.;
Novak, G.;
Nutter, D.;
O'Brient, R.;
Pascale, E.;
Poidevin, F.;
Rahlin, A. S.;
Reintsema, C. D.;
Ruhl, J. E.;
Runyan, M. C.;
Savini, G.;
Scott, D.;
Shariff, J. A.;
Soler, J. D.;
Thomas, N. E.;
Trangsrud, A.;
Truch, M. D.;
Tucker, C. E.;
Tucker, G. S.;
Tucker, R. S.;
Turner, A. D.;
Ward-Thompson, D.;
Weber, A. C.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2014-07-07, last modified: 2014-07-15
An attitude determination system for balloon-borne experiments is presented.
The system provides pointing information in azimuth and elevation for
instruments flying on stratospheric balloons over Antarctica. In-flight
attitude is given by the real-time combination of readings from star cameras, a
magnetometer, sun sensors, GPS, gyroscopes, tilt sensors and an elevation
encoder. Post-flight attitude reconstruction is determined from star camera
solutions, interpolated by the gyroscopes using an extended Kalman Filter. The
multi-sensor system was employed by the Balloon-borne Large Aperture
Submillimeter Telescope for Polarimetry (BLASTPol), an experiment that measures
polarized thermal emission from interstellar dust clouds. A similar system was
designed for the upcoming flight of SPIDER, a Cosmic Microwave Background
polarization experiment. The pointing requirements for these experiments are
discussed, as well as the challenges in designing attitude reconstruction
systems for high altitude balloon flights. In the 2010 and 2012 BLASTPol
flights from McMurdo Station, Antarctica, the system demonstrated an accuracy
of <5' rms in-flight, and <5" rms post-flight.
[13]
oai:arXiv.org:1407.2906 [pdf] - 1215590
Pre-flight integration and characterization of the SPIDER balloon-borne
telescope
Rahlin, A. S.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Crill, B. P.;
Doré, O.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Fraisse, A. A.;
Gambrel, A. E.;
Gandilo, N. N.;
Golwala, S.;
Gudmundsson, J. E.;
Halpern, M.;
Hasselfield, M. F.;
Hilton, G.;
Holmes, W. A.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kermish, Z. D.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Megerian, K.;
Moncelsi, L.;
Morford, T. A.;
Nagy, J. M.;
Netterfield, C. B.;
O'Brient, R.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Weber, A. C.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2014-07-09
We present the results of integration and characterization of the SPIDER
instrument after the 2013 pre-flight campaign. SPIDER is a balloon-borne
polarimeter designed to probe the primordial gravitational wave signal in the
degree-scale $B$-mode polarization of the cosmic microwave background. With six
independent telescopes housing over 2000 detectors in the 94 GHz and 150 GHz
frequency bands, SPIDER will map 7.5% of the sky with a depth of 11 to 14
$\mu$K$\cdot$arcmin at each frequency, which is a factor of $\sim$5 improvement
over Planck. We discuss the integration of the pointing, cryogenic,
electronics, and power sub-systems, as well as pre-flight characterization of
the detectors and optical systems. SPIDER is well prepared for a December 2014
flight from Antarctica, and is expected to be limited by astrophysical
foreground emission, and not instrumental sensitivity, over the survey region.
[14]
oai:arXiv.org:1407.1882 [pdf] - 1215474
BLASTbus electronics: general-purpose readout and control for
balloon-borne experiments
Benton, S. J.;
Ade, P. A.;
Amiri, M.;
Angilè, F. E.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Crill, B. P.;
Devlin, M. J.;
Dober, B.;
Doré, O. P.;
Dowell, C. D.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Fraisse, A. A.;
Fukui, Y.;
Galitzki, N.;
Gambrel, A. E.;
Gandilo, N. N.;
Golwala, S. R.;
Gudmundsson, J. E.;
Halpern, M.;
Hasselfield, M.;
Hilton, G. C.;
Holmes, W. A.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kermish, Z. D.;
Klein, J.;
Korotkov, A. L.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Matthews, T. G.;
Megerian, K. G.;
Moncelsi, L.;
Morford, T. A.;
Mroczkowski, T. K.;
Nagy, J. M.;
Netterfield, C. B.;
Novak, G.;
Nutter, D.;
O'Brient, R.;
Ogburn, R. W.;
Pascale, E.;
Poidevin, F.;
Rahlin, A. S.;
Reintsema, C. D.;
Ruhl, J. E.;
Runyan, M. C.;
Savini, G.;
Scott, D.;
Shariff, J. A.;
Soler, J. D.;
Thomas, N. E.;
Trangsrud, A.;
Truch, M. D.;
Tucker, C. E.;
Tucker, G. S.;
Tucker, R. S.;
Turner, A. D.;
Ward-Thompson, D.;
Weber, A. C.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2014-07-07
We present the second generation BLASTbus electronics. The primary purposes
of this system are detector readout, attitude control, and cryogenic
housekeeping, for balloon-borne telescopes. Readout of neutron transmutation
doped germanium (NTD-Ge) bolometers requires low noise and parallel acquisition
of hundreds of analog signals. Controlling a telescope's attitude requires the
capability to interface to a wide variety of sensors and motors, and to use
them together in a fast, closed loop. To achieve these different goals, the
BLASTbus system employs a flexible motherboard-daughterboard architecture. The
programmable motherboard features a digital signal processor (DSP) and
field-programmable gate array (FPGA), as well as slots for three
daughterboards. The daughterboards provide the interface to the outside world,
with versions for analog to digital conversion, and optoisolated digital
input/output. With the versatility afforded by this design, the BLASTbus also
finds uses in cryogenic, thermometry, and power systems. For accurate timing
control to tie everything together, the system operates in a fully synchronous
manner. BLASTbus electronics have been successfully deployed to the South Pole,
and flown on stratospheric balloons.
[15]
oai:arXiv.org:1407.1880 [pdf] - 1215472
Pointing control for the SPIDER balloon-borne telescope
Shariff, Jamil A.;
Ade, Peter A. R.;
Amiri, Mandana;
Benton, Steven J.;
Bock, Jamie J.;
Bond, J. Richard;
Bryan, Sean A.;
Chiang, H. Cynthia;
Contaldi, Carlo R.;
Crill, Brendan P.;
Doré, Olivier P.;
Farhang, Marzieh;
Filippini, Jeffrey P.;
Fissel, Laura M.;
Fraisse, Aurelien A.;
Gambrel, Anne E.;
Gandilo, Natalie N.;
Golwala, Sunil R.;
Gudmundsson, Jon E.;
Halpern, Mark;
Hasselfield, Matthew;
Hilton, Gene C.;
Holmes, Warren A.;
Hristov, Viktor V.;
Irwin, Kent D.;
Jones, William C.;
Kermish, Zigmund D.;
Kuo, Chao-Lin;
MacTavish, Carolyn J.;
Mason, Peter V.;
Megerian, Krikor G.;
Moncelsi, Lorenzo;
Morford, Tracy A.;
Nagy, Johanna M.;
Netterfield, C. Barth;
O'Brient, Roger;
Rahlin, Alexandra S.;
Reintsema, Carl D.;
Ruhl, John E.;
Runyan, Marcus C.;
Soler, Juan D.;
Trangsrud, Amy;
Tucker, Carole E.;
Tucker, Rebecca S.;
Turner, Anthony D.;
Weber, Alexis C.;
Wiebe, Donald V.;
Young, Edward Y.
Submitted: 2014-07-07
We present the technology and control methods developed for the pointing
system of the SPIDER experiment. SPIDER is a balloon-borne polarimeter designed
to detect the imprint of primordial gravitational waves in the polarization of
the Cosmic Microwave Background radiation. We describe the two main components
of the telescope's azimuth drive: the reaction wheel and the motorized pivot. A
13 kHz PI control loop runs on a digital signal processor, with feedback from
fibre optic rate gyroscopes. This system can control azimuthal speed with <
0.02 deg/s RMS error. To control elevation, SPIDER uses stepper-motor-driven
linear actuators to rotate the cryostat, which houses the optical instruments,
relative to the outer frame. With the velocity in each axis controlled in this
way, higher-level control loops on the onboard flight computers can implement
the pointing and scanning observation modes required for the experiment. We
have accomplished the non-trivial task of scanning a 5000 lb payload
sinusoidally in azimuth at a peak acceleration of 0.8 deg/s$^2$, and a peak
speed of 6 deg/s. We can do so while reliably achieving sub-arcminute pointing
control accuracy.
[16]
oai:arXiv.org:1407.1881 [pdf] - 1215473
Design and construction of a carbon fiber gondola for the SPIDER
balloon-borne telescope
Soler, J. D.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, C.;
Contaldi, C. C.;
Crill, B. P.;
Doré, O. P.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Fraisse, A. A.;
Gambrel, A. E.;
Gandilo, N. N.;
Golwala, S.;
Gudmundsson, J. E.;
Halpern, M.;
Hasselfield, M.;
Hilton, G. C.;
Holmes, W. A.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kermish, Z. D.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Megerian, K. G.;
Moncelsi, L.;
Nagy, J. M.;
Netterfield, C. B.;
O'Brient, R.;
Rahlin, A. S.;
Reintsema, C. D.;
Ruhl, J. E.;
Runyan, M. C.;
Shariff, J. A.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Weber, A. C.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2014-07-07
We introduce the light-weight carbon fiber and aluminum gondola designed for
the SPIDER balloon-borne telescope. SPIDER is designed to measure the
polarization of the Cosmic Microwave Background radiation with unprecedented
sensitivity and control of systematics in search of the imprint of inflation: a
period of exponential expansion in the early Universe. The requirements of this
balloon-borne instrument put tight constrains on the mass budget of the
payload. The SPIDER gondola is designed to house the experiment and guarantee
its operational and structural integrity during its balloon-borne flight, while
using less than 10% of the total mass of the payload. We present a construction
method for the gondola based on carbon fiber reinforced polymer tubes with
aluminum inserts and aluminum multi-tube joints. We describe the validation of
the model through Finite Element Analysis and mechanical tests.
[17]
oai:arXiv.org:1106.3087 [pdf] - 659433
SPIDER: Probing the Early Universe with a Suborbital Polarimeter
Fraisse, A. A.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bonetti, J. A.;
Bryan, S.;
Burger, B.;
Chiang, H. C.;
Clark, C. N.;
Contaldi, C. R.;
Crill, B. P.;
Davis, G.;
Doré, O.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Gandilo, N. N.;
Golwala, S.;
Gudmundsson, J. E.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K.;
Jones, W. C.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Montroy, T. E.;
Morford, T. A.;
Netterfield, C. B.;
O'Dea, D. T.;
Rahlin, A. S.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Schenker, M. A.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Wiebe, D.
Submitted: 2011-06-15, last modified: 2013-05-02
We evaluate the ability of SPIDER, a balloon-borne polarimeter, to detect a
divergence-free polarization pattern ("B-modes") in the Cosmic Microwave
Background (CMB). In the inflationary scenario, the amplitude of this signal is
proportional to that of the primordial scalar perturbations through the
tensor-to-scalar ratio r. We show that the expected level of systematic error
in the SPIDER instrument is significantly below the amplitude of an interesting
cosmological signal with r=0.03. We present a scanning strategy that enables us
to minimize uncertainty in the reconstruction of the Stokes parameters used to
characterize the CMB, while accessing a relatively wide range of angular
scales. Evaluating the amplitude of the polarized Galactic emission in the
SPIDER field, we conclude that the polarized emission from interstellar dust is
as bright or brighter than the cosmological signal at all SPIDER frequencies
(90 GHz, 150 GHz, and 280 GHz), a situation similar to that found in the
"Southern Hole." We show that two ~20-day flights of the SPIDER instrument can
constrain the amplitude of the B-mode signal to r<0.03 (99% CL) even when
foreground contamination is taken into account. In the absence of foregrounds,
the same limit can be reached after one 20-day flight.
[18]
oai:arXiv.org:1106.2507 [pdf] - 372118
Thermal architecture for the SPIDER flight cryostat
Gudmundsson, J. E.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bihary, R.;
Bock, J. J.;
Bond, J. R.;
Bonetti, J. A.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Crill, B. P.;
O'Dea, D.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Gandilo, N. N.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Helson, K. R.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Montroy, T. E.;
Morford, T. A.;
Netterfield, C. B.;
Rahlin, A. S.;
Reintsema, C. D.;
Ruhl, J. E.;
Runyan, M. C.;
Schenker, M. A.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.
Submitted: 2011-06-13
We describe the cryogenic system for SPIDER, a balloon-borne microwave
polarimeter that will map 8% of the sky with degree-scale angular resolution.
The system consists of a 1284 L liquid helium cryostat and a 16 L
capillary-filled superfluid helium tank, which provide base operating
temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption
refrigerators supply sub-Kelvin cooling power to multiple focal planes, which
are housed in monochromatic telescope inserts. The main helium tank is
suspended inside the vacuum vessel with thermally insulating fiberglass
flexures, and shielded from thermal radiation by a combination of two vapor
cooled shields and multi-layer insulation. This system allows for an extremely
low instrumental background and a hold time in excess of 25 days. The total
mass of the cryogenic system, including cryogens, is approximately 1000 kg.
This enables conventional long duration balloon flights. We will discuss the
design, thermal analysis, and qualification of the cryogenic system.
[19]
oai:arXiv.org:1106.2173 [pdf] - 372068
Design and performance of the Spider instrument
Runyan, M. C.;
Ade, P. A. R.;
Amiri, M.;
Benton, S.;
Bihary, R.;
Bock, J. J.;
Bond, J. R.;
Bonetti, J. A.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Crill, B. P.;
Dore, O.;
O'Dea, D.;
Farhang, M.;
Filippini, J. P.;
Fissel, L.;
Gandilo, N.;
Golwala, S. R.;
Gudmundsson, J. E.;
Hasselfield, M.;
Halpern, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Morford, T. A.;
Montroy, T. E.;
Netterfield, C. B.;
Rahlin, A. S.;
Reintsema, C. D.;
Ruhl, J. E.;
Schenker, M. A.;
Shariff, J.;
Soler, J. D.;
Trangsrud, A.;
Tucker, R. S.;
Tucker, C.;
Turner, A.
Submitted: 2011-06-10
Here we describe the design and performance of the Spider instrument. Spider
is a balloon-borne cosmic microwave background polarization imager that will
map part of the sky at 90, 145, and 280 GHz with sub-degree resolution and high
sensitivity. This paper discusses the general design principles of the
instrument inserts, mechanical structures, optics, focal plane architecture,
thermal architecture, and magnetic shielding of the TES sensors and SQUID
multiplexer. We also describe the optical, noise, and magnetic shielding
performance of the 145 GHz prototype instrument insert.
[20]
oai:arXiv.org:1106.2158 [pdf] - 371654
SPIDER: a balloon-borne CMB polarimeter for large angular scales
Filippini, J. P.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bihary, R.;
Bock, J. J.;
Bond, J. R.;
Bonetti, J. A.;
Bryan, S. A.;
Burger, B.;
Chiang, H. C.;
Contaldi, C. R.;
Crill, B. P.;
Doré, O.;
Farhang, M.;
Fissel, L. M.;
Gandilo, N. N.;
Golwala, S. R.;
Gudmundsson, J. E.;
Halpern, M.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Montroy, T. E.;
Morford, T. A.;
Netterfield, C. B.;
O'Dea, D. T.;
Rahlin, A. S.;
Reintsema, C. D.;
Ruhl, J. E.;
Runyan, M. C.;
Schenker, M. A.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.
Submitted: 2011-06-10
We describe SPIDER, a balloon-borne instrument to map the polarization of the
millimeter-wave sky with degree angular resolution. Spider consists of six
monochromatic refracting telescopes, each illuminating a focal plane of
large-format antenna-coupled bolometer arrays. A total of 2,624 superconducting
transition-edge sensors are distributed among three observing bands centered at
90, 150, and 280 GHz. A cold half-wave plate at the aperture of each telescope
modulates the polarization of incoming light to control systematics. Spider's
first flight will be a 20-30-day Antarctic balloon campaign in December 2011.
This flight will map \sim8% of the sky to achieve unprecedented sensitivity to
the polarization signature of the gravitational wave background predicted by
inflationary cosmology. The Spider mission will also serve as a proving ground
for these detector technologies in preparation for a future satellite mission.
[21]
oai:arXiv.org:1102.0559 [pdf] - 1051855
Spider Optimization II: Optical, Magnetic and Foreground Effects
O'Dea, D. T.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bonetti, J. A.;
Bryan, S.;
Burger, B.;
Chiang, H. C.;
Clark, C. N.;
Contaldi, C. R.;
Crill, B. P.;
Davis, G.;
Dore, O.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Fraisse, A. A.;
Gandilo, N. N.;
Golwala, S.;
Gudmundsson, J. E.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K.;
Jones, W. C.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Montroy, T. E.;
Morford, T. A.;
Netterfield, C. B.;
Rahlin, A. S.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Schenker, M. A.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Wiebe, D.
Submitted: 2011-02-02
Spider is a balloon-borne instrument designed to map the polarization of the
cosmic microwave background (CMB) with degree-scale resolution over a large
fraction of the sky. Spider's main goal is to measure the amplitude of
primordial gravitational waves through their imprint on the polarization of the
CMB if the tensor-to-scalar ratio, r, is greater than 0.03. To achieve this
goal, instrumental systematic errors must be controlled with unprecedented
accuracy. Here, we build on previous work to use simulations of Spider
observations to examine the impact of several systematic effects that have been
characterized through testing and modeling of various instrument components. In
particular, we investigate the impact of the non-ideal spectral response of the
half-wave plates, coupling between focal plane components and the Earth's
magnetic field, and beam mismatches and asymmetries. We also present a model of
diffuse polarized foreground emission based on a three-dimensional model of the
Galactic magnetic field and dust, and study the interaction of this foreground
emission with our observation strategy and instrumental effects. We find that
the expected level of foreground and systematic contamination is sufficiently
low for Spider to achieve its science goals.
[22]
oai:arXiv.org:1009.3685 [pdf] - 1040693
Antenna-coupled TES Bolometer Arrays for BICEP2/Keck and SPIDER
Orlando, A.;
Aikin, R. W;
Amiri, M.;
Bock, J. J.;
Bonetti, J. A.;
Brevik, J. A.;
Burger, B.;
Chattopadthyay, G.;
Day, P. K.;
Filippini, J. P.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Hilton, G. C.;
Irwin, K. D.;
Kenyon, M.;
Kovac, J. M.;
Kuo, C. L.;
Lange, A. E.;
LeDuc, H. G.;
Llombart, N.;
Nguyen, H. T.;
Ogburn, R. W.;
Reintsema, C. D.;
Runyan, M. C.;
Staniszewski, Z.;
Sudiwala, R.;
Teply, G.;
Trangsrud, A. R.;
Turner, A. D.;
Wilson, P.
Submitted: 2010-09-19
BICEP2/Keck and SPIDER are cosmic microwave background (CMB) polarimeters
targeting the B-mode polarization induced by primordial gravitational waves
from inflation. They will be using planar arrays of polarization sensitive
antenna-coupled TES bolometers, operating at frequencies between 90 GHz and 220
GHz. At 150 GHz each array consists of 64 polarimeters and four of these arrays
are assembled together to make a focal plane, for a total of 256
dual-polarization elements (512 TES sensors). The detector arrays are
integrated with a time-domain SQUID multiplexer developed at NIST and read out
using the multi-channels electronics (MCE) developed at the University of
British Columbia. Following our progress in improving detector parameters
uniformity across the arrays and fabrication yield, our main effort has focused
on improving detector arrays optical and noise performances, in order to
produce science grade focal planes achieving target sensitivities. We report on
changes in detector design implemented to optimize such performances and
following focal plane arrays characterization. BICEP2 has deployed a first 150
GHz science grade focal plane to the South Pole in December 2009.
[23]
oai:arXiv.org:1006.3874 [pdf] - 934286
Modeling and characterization of the SPIDER half-wave plate
Bryan, Sean A.;
Ade, Peter A. R.;
Amiri, Mandana;
Benton, Steve;
Bihary, Richard;
Bock, James J.;
Bond, J. Richard;
Bonetti, Joseph A.;
Chiang, H. Cynthia;
Contaldi, Carlo R.;
Crill, Brendan P.;
O'Dea, Daniel;
Dore, Olivier;
Farhang, Marzieh;
Filippini, Jeffrey P.;
Fissel, Laura;
Gandilo, Natalie;
Golwala, Sunil;
Gudmundsson, Jon E.;
Hasselfield, Matthew;
Halpern, Mark;
Helson, Kyle R.;
Hilton, Gene;
Holmes, Warren;
Hristov, Viktor V.;
Irwin, Kent D.;
Jones, William C.;
Kuo, Chao Lin;
MacTavish, Carrie J.;
Mason, Peter;
Morford, Tracy;
Montroy, Thomas E.;
Netterfield, C. Barth;
Rahlin, Alexandra S.;
Reintsema, Carl D.;
Riley, Daniel;
Ruhl, John E.;
Runyan, Marcus C.;
Schenker, Matthew A.;
Shariff, Jamil;
Soler, Juan Diego;
Trangsrud, Amy;
Tucker, Rebecca;
Tucker, Carole;
Turner, Anthony
Submitted: 2010-06-19
Spider is a balloon-borne array of six telescopes that will observe the
Cosmic Microwave Background. The 2624 antenna-coupled bolometers in the
instrument will make a polarization map of the CMB with approximately one-half
degree resolution at 145 GHz. Polarization modulation is achieved via a
cryogenic sapphire half-wave plate (HWP) skyward of the primary optic. We have
measured millimeter-wave transmission spectra of the sapphire at room and
cryogenic temperatures. The spectra are consistent with our physical optics
model, and the data gives excellent measurements of the indices of A-cut
sapphire. We have also taken preliminary spectra of the integrated HWP, optical
system, and detectors in the prototype Spider receiver. We calculate the
variation in response of the HWP between observing the CMB and foreground
spectra, and estimate that it should not limit the Spider constraints on
inflation.
[24]
oai:arXiv.org:0908.1464 [pdf] - 27202
Antenna-coupled TES bolometer arrays for CMB polarimetry
Kuo, C. L.;
Bock, J. J.;
Bonetti, J. A.;
Brevik, J.;
Chattopadhyay, G.;
Day, P. K.;
Golwala, S.;
Kenyon, M.;
Lange, A. E.;
LeDuc, H. G.;
Nguyen, H.;
Ogburn, R. W.;
Orlando, A.;
Trangsrud, A.;
Turner, A.;
Wang, G.;
Zmuidzinas, J.
Submitted: 2009-08-11
We describe the design and performance of polarization selective
antenna-coupled TES arrays that will be used in several upcoming Cosmic
Microwave Background (CMB) experiments: SPIDER, BICEP-2/SPUD. The fully
lithographic polarimeter arrays utilize planar phased-antennas for collimation
(F/4 beam) and microstrip filters for band definition (25% bandwidth). These
devices demonstrate high optical efficiency, excellent beam shapes, and
well-defined spectral bands. The dual-polarization antennas provide
well-matched beams and low cross polarization response, both important for
high-fidelity polarization measurements. These devices have so far been
developed for the 100 GHz and 150 GHz bands, two premier millimeter-wave
atmospheric windows for CMB observations. In the near future, the flexible
microstrip-coupled architecture can provide photon noise-limited detection for
the entire frequency range of the CMBPOL mission. This paper is a summary of
the progress we have made since the 2006 SPIE meeting in Orlando, FL.
[25]
oai:arXiv.org:0807.1548 [pdf] - 14377
SPIDER: A Balloon-borne Large-scale CMB Polarimeter
Crill, B. P.;
Ade, P. A. R.;
Battistelli, E. S.;
Benton, S.;
Bihary, R.;
Bock, J. J.;
Bond, J. R.;
Brevik, J.;
Bryan, S.;
Contaldi, C. R.;
Dore, O.;
Farhang, M.;
Fissel, L.;
Golwala, S. R.;
Halpern, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K.;
Jones, W. C.;
Kuo, C. L.;
Lange, A. E.;
Lawrie, C.;
MacTavish, C. J.;
Martin, T. G.;
Mason, P.;
Montroy, T. E.;
Netterfield, C. B.;
Pascale, E.;
Riley, D.;
Ruhl, J. E.;
Runyan, M. C.;
Trangsrud, A.;
Tucker, C.;
Turner, A.;
Viero, M.;
Wiebe, D.
Submitted: 2008-07-09
Spider is a balloon-borne experiment that will measure the polarization of
the Cosmic Microwave Background over a large fraction of a sky at 1 degree
resolution. Six monochromatic refracting millimeter-wave telescopes with large
arrays of antenna-coupled transition-edge superconducting bolometers will
provide system sensitivities of 4.2 and 3.1 micro K_cmb rt s at 100 and 150
GHz, respectively. A rotating half-wave plate will modulate the polarization
sensitivity of each telescope, controlling systematics. Bolometer arrays
operating at 225 GHz and 275 GHz will allow removal of polarized galactic
foregrounds. In a 2-6 day first flight from Alice Springs, Australia in 2010,
Spider will map 50% of the sky to a depth necessary to improve our knowledge of
the reionization optical depth by a large factor.
[26]
oai:arXiv.org:0710.0375 [pdf] - 5549
Spider Optimization: Probing the Systematics of a Large Scale B-Mode
Experiment
MacTavish, C. J.;
Ade, P. A. R.;
Battistelli, E. S.;
Benton, S.;
Bihary, R.;
Bock, J. J.;
Bond, J. R.;
Brevik, J.;
Bryan, S.;
Contaldi, C. R.;
Crill, B. P.;
Doré, O.;
Fissel, L.;
Golwala, S. R.;
Halpern, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K.;
Jones, W. C.;
Kuo, C. L.;
Lange, A. E.;
Lawrie, C.;
Martin, T. G.;
Mason, P.;
Montroy, T. E.;
Netterfield, C. B.;
Riley, D.;
Ruhl, J. E.;
Trangsrud, A.;
Tucker, C.;
Turner, A.;
Viero, M.;
Wiebe, D.
Submitted: 2007-10-01
Spider is a long-duration, balloon-borne polarimeter designed to measure
large scale Cosmic Microwave Background (CMB) polarization with very high
sensitivity and control of systematics. The instrument will map over half the
sky with degree angular resolution in I, Q and U Stokes parameters, in four
frequency bands from 96 to 275 GHz. Spider's ultimate goal is to detect the
primordial gravity wave signal imprinted on the CMB B-mode polarization. One of
the challenges in achieving this goal is the minimization of the contamination
of B-modes by systematic effects. This paper explores a number of instrument
systematics and observing strategies in order to optimize B-mode sensitivity.
This is done by injecting realistic-amplitude, time-varying systematics in a
set of simulated time-streams. Tests of the impact of detector noise
characteristics, pointing jitter, payload pendulations, polarization angle
offsets, beam systematics and receiver gain drifts are shown. Spider's default
observing strategy is to spin continuously in azimuth, with polarization
modulation achieved by either a rapidly spinning half-wave plate or a rapidly
spinning gondola and a slowly stepped half-wave plate. Although the latter is
more susceptible to systematics, results shown here indicate that either mode
of operation can be used by Spider.