sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Torrioli, G.

Normalized to: Torrioli, G.

8 article(s) in total. 99 co-authors, from 1 to 5 common article(s). Median position in authors list is 18,0.

[1]  oai:arXiv.org:1912.06390  [pdf] - 2014523
The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence Detector
Comments: Accepted for publication in the Journal of Low Temperature Physics for LTD-18 special issue
Submitted: 2019-12-13
The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed to reduce the particle background of the instrument and to enable the mission science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES network. We have developed the CryoAC Demonstration Model, a prototype aimed to probe the critical technologies of the detector, i.e. the suspended absorber with an active area of 1 cm2; the low energy threshold of 20 keV; and the operation connected to a 50 mK thermal bath with a power dissipation less than 40 nW. Here we report the test performed on the first CryoAC DM sample (namely the AC-S10 prototype), showing that it is fully compliant with its requirements.
[2]  oai:arXiv.org:1807.08561  [pdf] - 1720395
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: assessing the role of the athermal phonons collectors in the AC-S8 prototype
Comments: Accepted for publication in the Journal of Low Temperature Physics for LTD-17 special issue
Submitted: 2018-07-23
The ATHENA X-ray Observatory is the second large-class mission in the ESA Cosmic Vision 2015-2025 science programme. One of the two on-board instruments is the X-IFU, an imaging spectrometer based on a large array of TES microcalorimeters. To reduce the particle-induced background, the spectrometer works in combination with a Cryogenic Anticoincidence detector (CryoAC), placed less than 1 mm below the TES array. The last CryoAC single-pixel prototypes, namely AC-S7 and AC-S8, are based on large area (1 cm2) Silicon absorbers sensed by 65 parallel-connected iridium TES. This design has been adopted to improve the response generated by the athermal phonons, which will be used as fast anticoincidence flag. The latter sample is featured also with a network of Aluminum fingers directly connected to the TES, designed to further improve the athermals collection efficiency. In this paper we will report the main results obtained with AC-S8, showing that the additional fingers network is able to increase the energy collected from the athermal part of the pulses (from the 6% of AC-S7 up to the 26 % with AC-S8). Furthermore, the finger design is able to prevent the quasiparticle recombination in the aluminum, assuring a fast pulse rising front (L/R limited). In our road map, the AC-S8 prototype is the last step before the development of the CryoAC Demonstration Model (DM), which will be the detector able to demonstrate the critical technologies expected in the CryoAC development programme.
[3]  oai:arXiv.org:1807.08565  [pdf] - 1720396
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: improvement of the test setup towards the Demonstration Model
Comments: Accepted for publication in the Journal of Low Temperature Physics for LTD-17 special issue
Submitted: 2018-07-23
The ATHENA X-IFU development program foresees to build and characterize an instrument Demonstration Model (DM), in order to probe the system critical technologies before the mission adoption. In this respect, we are now developing the DM of the X-IFU Cryogenic Anticoincidence Detector (CryoAC), which will be delivered to the Focal Plane Assembly (FPA) development team for the integration with the TES array. Before the delivery, we will characterize and test the CryoAC DM in our CryoLab at INAF/IAPS. In this paper we report the main results of the activities performed to improve our cryogenic test setup, making it suitable for the DM integration. These activities mainly consist in the development of a mechanichal setup and a cryogenic magnetic shielding system, whose effectiveness has been assessed by FEM simulations and a measurement at warm. The preliminary performance test has been performed by means of the last CryoAC single pixel prototype, the AC-S8 pre-DM sample.
[4]  oai:arXiv.org:1807.02344  [pdf] - 1714361
The Cryogenic Anticoincidence Detector for ATHENA X-IFU: Preliminary test of AC-S9 towards the Demonstration Model
Comments: Proceeding of the SPIE Astronomical Telescopes + Instrumentation 2018
Submitted: 2018-07-06, last modified: 2018-07-11
Our team is developing the Cryogenic Anticoincidence Detector (CryoAC) of the ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector, which will be placed less than 1 mm below the main TES array detector. We are now producing the CryoAC Demonstration Model (DM): a single pixel prototype able to probe the detector critical technologies, i.e. the operation at 50 mK thermal bath, the threshold energy at 20 keV and the reproducibility of the thermal conductance between the suspended absorber and the thermal bath. This detector will be integrated and tested in our cryogenic setup at INAF/IAPS, and then delivered to SRON for the integration in the X-IFU Focal Plane Assemby (FPA) DM. In this paper we report the status of the CryoAC DM development, showing the main result obtained with the last developed prototype, namely AC-S9. This is a DM-like sample, which we have preliminary integrated and tested before performing the final etching process to suspend the silicon absorber. The results are promising for the DM, since despite the limitations due to the absence of the final etching (high thermal capacity, high thermal conductance, partial TES surface coverage), we have been able to operate the detector with TB = 50 mK and to detect 6 keV photons, thus having a low energy threshold fully compatible with our requirement (20 keV).
[5]  oai:arXiv.org:1308.6784  [pdf] - 713384
The Hot and Energetic Universe: The X-ray Integral Field Unit (X-IFU) for Athena+
Comments: Supporting paper for the science theme "The Hot and Energetic Universe" to be implemented by the Athena+ X-ray observatory (http://www.the-athena-x-ray-observatory.eu). 17 pages, 19 figures
Submitted: 2013-08-30
The Athena+ mission concept is designed to implement the Hot and Energetic Universe science theme submitted to the European Space Agency in response to the call for White Papers for the definition of the L2 and L3 missions of its science program. The Athena+ science payload consists of a large aperture high angular resolution X-ray optics and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager (WFI). The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), offering 2.5 eV spectral resolution, with ~5" pixels, over a field of view of 5 arc minutes in diameter. In this paper, we briefly describe the Athena+ mission concept and the X-IFU performance requirements. We then present the X-IFU detector and readout electronics principles, the current design of the focal plane assembly, the cooling chain and review the global architecture design. Finally, we describe the current performance estimates, in terms of effective area, particle background rejection, count rate capability and velocity measurements. Finally, we emphasize on the latest technology developments concerning TES array fabrication, spectral resolution and readout performance achieved to show that significant progresses are being accomplished towards the demanding X-IFU requirements.
[6]  oai:arXiv.org:astro-ph/0408544  [pdf] - 67035
Cumulative analysis of the association between the gravitational wave detectors NAUTILUS and EXPLORER and the gamma-ray bursts detected by BATSE and BeppoSAX
Comments: 10 pages, 6 figures; minor corrections, added references. Accepted for publication in Phys. Rev. D
Submitted: 2004-08-30, last modified: 2005-02-10
The statistical association between the output of the Gravitational Wave (GW) detectors EXPLORER and NAUTILUS and a list of Gamma Ray Bursts (GRBs) detected by the satellite experiments BATSE and BeppoSAX has been analyzed using cumulative algorithms. GW detector data collected between 1991 and 1999 have been correlated to the GRB flux peak times. The cumulative analysis of a large number of GRBs (387) allows to push the upper bound for the corresponding GW burst amplitude down to $h = 2.5\cdot10^{-19}$.
[7]  oai:arXiv.org:gr-qc/0210053  [pdf] - 398744
Study of the coincidences between the gravitational wave detectors EXPLORER and NAUTILUS in 2001
Comments:
Submitted: 2002-10-17
We report the result from a search for bursts of gravitational waves using data collected by the cryogenic resonant detectors EXPLORER and NAUTILUS during the year 2001, for a total measuring time of 90 days. With these data we repeated the coincidence search performed on the 1998 data (which showed a small coincidence excess) applying data analysis algorithms based on known physical characteristics of the detectors. With the 2001 data a new interesting coincidence excess is found when the detectors are favorably oriented with respect to the Galactic Disk.
[8]  oai:arXiv.org:astro-ph/0206431  [pdf] - 50062
Search for correlation between GRB's detected by BeppoSAX and gravitational wave detectors EXPLORER and NAUTILUS
Comments: 14 pages, 7 figures. Latex file, compiled with cernik.cls (provided in the package)
Submitted: 2002-06-25, last modified: 2002-07-12
Data obtained during five months of 2001 with the gravitational wave (GW) detectors EXPLORER and NAUTILUS were studied in correlation with the gamma ray burst data (GRB) obtained with the BeppoSAX satellite. During this period BeppoSAX was the only GRB satellite in operation, while EXPLORER and NAUTILUS were the only GW detectors in operation. No correlation between the GW data and the GRB bursts was found. The analysis, performed over 47 GRB's, excludes the presence of signals of amplitude h >=1.2 * 10^{-18}, with 95 % probability, if we allow a time delay between GW bursts and GRB within +-400 s, and h >= 6.5 * 10^{-19}, if the time delay is within +- 5 s. The result is also provided in form of scaled likelihood for unbiased interpretation and easier use for further analysis.