Normalized to: Torrioli, G.
[1]
oai:arXiv.org:1912.06390 [pdf] - 2014523
The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence
Detector
D'Andrea, Matteo;
Macculi, Claudio;
Torrioli, Guido;
Argan, Andrea;
Brienza, Daniele;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Barusso, Lorenzo Ferrari;
Gatti, Flavio;
Rigano, Manuela;
Volpe, Angela;
Battistelli, Elia Stefano
Submitted: 2019-12-13
The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed
to reduce the particle background of the instrument and to enable the mission
science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES
network. We have developed the CryoAC Demonstration Model, a prototype aimed to
probe the critical technologies of the detector, i.e. the suspended absorber
with an active area of 1 cm2; the low energy threshold of 20 keV; and the
operation connected to a 50 mK thermal bath with a power dissipation less than
40 nW. Here we report the test performed on the first CryoAC DM sample (namely
the AC-S10 prototype), showing that it is fully compliant with its
requirements.
[2]
oai:arXiv.org:1807.08561 [pdf] - 1720395
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: assessing the
role of the athermal phonons collectors in the AC-S8 prototype
D'Andrea, Matteo;
Macculi, Claudio;
Argan, Andrea;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Corsini, Dario;
Gatti, Flavio;
Torrioli, Guido
Submitted: 2018-07-23
The ATHENA X-ray Observatory is the second large-class mission in the ESA
Cosmic Vision 2015-2025 science programme. One of the two on-board instruments
is the X-IFU, an imaging spectrometer based on a large array of TES
microcalorimeters. To reduce the particle-induced background, the spectrometer
works in combination with a Cryogenic Anticoincidence detector (CryoAC), placed
less than 1 mm below the TES array. The last CryoAC single-pixel prototypes,
namely AC-S7 and AC-S8, are based on large area (1 cm2) Silicon absorbers
sensed by 65 parallel-connected iridium TES. This design has been adopted to
improve the response generated by the athermal phonons, which will be used as
fast anticoincidence flag. The latter sample is featured also with a network of
Aluminum fingers directly connected to the TES, designed to further improve the
athermals collection efficiency. In this paper we will report the main results
obtained with AC-S8, showing that the additional fingers network is able to
increase the energy collected from the athermal part of the pulses (from the 6%
of AC-S7 up to the 26 % with AC-S8). Furthermore, the finger design is able to
prevent the quasiparticle recombination in the aluminum, assuring a fast pulse
rising front (L/R limited). In our road map, the AC-S8 prototype is the last
step before the development of the CryoAC Demonstration Model (DM), which will
be the detector able to demonstrate the critical technologies expected in the
CryoAC development programme.
[3]
oai:arXiv.org:1807.08565 [pdf] - 1720396
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: improvement of
the test setup towards the Demonstration Model
D'Andrea, Matteo;
Macculi, Claudio;
Argan, Andrea;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Corsini, Dario;
Gatti, Flavio;
Torrioli, Guido;
Volpe, Angela
Submitted: 2018-07-23
The ATHENA X-IFU development program foresees to build and characterize an
instrument Demonstration Model (DM), in order to probe the system critical
technologies before the mission adoption. In this respect, we are now
developing the DM of the X-IFU Cryogenic Anticoincidence Detector (CryoAC),
which will be delivered to the Focal Plane Assembly (FPA) development team for
the integration with the TES array. Before the delivery, we will characterize
and test the CryoAC DM in our CryoLab at INAF/IAPS. In this paper we report the
main results of the activities performed to improve our cryogenic test setup,
making it suitable for the DM integration. These activities mainly consist in
the development of a mechanichal setup and a cryogenic magnetic shielding
system, whose effectiveness has been assessed by FEM simulations and a
measurement at warm. The preliminary performance test has been performed by
means of the last CryoAC single pixel prototype, the AC-S8 pre-DM sample.
[4]
oai:arXiv.org:1807.02344 [pdf] - 1714361
The Cryogenic Anticoincidence Detector for ATHENA X-IFU: Preliminary
test of AC-S9 towards the Demonstration Model
D'Andrea, Matteo;
Macculi, Claudio;
Argan, Andrea;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Ceriale, Valentina;
Gallucci, Giovanni;
Gatti, Flavio;
Torrioli, Guido;
Volpe, Angela
Submitted: 2018-07-06, last modified: 2018-07-11
Our team is developing the Cryogenic Anticoincidence Detector (CryoAC) of the
ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector,
which will be placed less than 1 mm below the main TES array detector. We are
now producing the CryoAC Demonstration Model (DM): a single pixel prototype
able to probe the detector critical technologies, i.e. the operation at 50 mK
thermal bath, the threshold energy at 20 keV and the reproducibility of the
thermal conductance between the suspended absorber and the thermal bath. This
detector will be integrated and tested in our cryogenic setup at INAF/IAPS, and
then delivered to SRON for the integration in the X-IFU Focal Plane Assemby
(FPA) DM.
In this paper we report the status of the CryoAC DM development, showing the
main result obtained with the last developed prototype, namely AC-S9. This is a
DM-like sample, which we have preliminary integrated and tested before
performing the final etching process to suspend the silicon absorber. The
results are promising for the DM, since despite the limitations due to the
absence of the final etching (high thermal capacity, high thermal conductance,
partial TES surface coverage), we have been able to operate the detector with
TB = 50 mK and to detect 6 keV photons, thus having a low energy threshold
fully compatible with our requirement (20 keV).
[5]
oai:arXiv.org:1308.6784 [pdf] - 713384
The Hot and Energetic Universe: The X-ray Integral Field Unit (X-IFU)
for Athena+
Barret, D.;
Herder, J. W. den;
Piro, L.;
Ravera, L.;
Hartog, R. Den;
Macculi, C.;
Barcons, X.;
Page, M.;
Paltani, S.;
Rauw, G.;
Wilms, J.;
Ceballos, M.;
Duband, L.;
Gottardi, L.;
Lotti, S.;
de Plaa, J.;
Pointecouteau, E.;
Schmid, C.;
Akamatsu, H.;
Bagliani, D.;
Bandler, S.;
Barbera, M.;
Bastia, P.;
Biasotti, M.;
Branco, M.;
Camon, A.;
Cara, C.;
Cobo, B.;
Colasanti, L.;
Costa-Kramer, J. L.;
Corcione, L.;
Doriese, W.;
Duval, J. M.;
Fabrega, L.;
Gatti, F.;
de Gerone, M.;
Guttridge, P.;
Kelley, R.;
Kilbourne, C.;
van der Kuur, J.;
Mineo, T.;
Mitsuda, K.;
Natalucci, L.;
Ohashi, T.;
Peille, P.;
Perinati, E.;
Pigot, C.;
Pizzigoni, G.;
Pobes, C.;
Porter, F.;
Renotte, E.;
Sauvageot, J. L.;
Sciortino, S.;
Torrioli, G.;
Valenziano, L.;
Willingale, D.;
de Vries, C.;
van Weers, H.
Submitted: 2013-08-30
The Athena+ mission concept is designed to implement the Hot and Energetic
Universe science theme submitted to the European Space Agency in response to
the call for White Papers for the definition of the L2 and L3 missions of its
science program. The Athena+ science payload consists of a large aperture high
angular resolution X-ray optics and twelve meters away, two interchangeable
focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide
Field Imager (WFI). The X-IFU is a cryogenic X-ray spectrometer, based on a
large array of Transition Edge Sensors (TES), offering 2.5 eV spectral
resolution, with ~5" pixels, over a field of view of 5 arc minutes in diameter.
In this paper, we briefly describe the Athena+ mission concept and the X-IFU
performance requirements. We then present the X-IFU detector and readout
electronics principles, the current design of the focal plane assembly, the
cooling chain and review the global architecture design. Finally, we describe
the current performance estimates, in terms of effective area, particle
background rejection, count rate capability and velocity measurements. Finally,
we emphasize on the latest technology developments concerning TES array
fabrication, spectral resolution and readout performance achieved to show that
significant progresses are being accomplished towards the demanding X-IFU
requirements.
[6]
oai:arXiv.org:astro-ph/0408544 [pdf] - 67035
Cumulative analysis of the association between the gravitational wave
detectors NAUTILUS and EXPLORER and the gamma-ray bursts detected by BATSE
and BeppoSAX
Astone, P.;
Babusci, D.;
Bassan, M.;
Carelli, P.;
Coccia, E.;
Cosmelli, C.;
D'Antonio, S.;
Fafone, V.;
Frontera, F.;
Giordano, G.;
Guidorzi, C.;
Marini, A.;
Minenkov, Y.;
Modena, I.;
Modestino, G.;
Moleti, A.;
Montanari, E.;
Pallottino, G. V.;
Pizzella, G.;
Quintieri, L.;
Rocchi, A.;
Ronga, F.;
Sperandio, L.;
Terenzi, R.;
Torrioli, G.;
Visco, M.
Submitted: 2004-08-30, last modified: 2005-02-10
The statistical association between the output of the Gravitational Wave (GW)
detectors EXPLORER and NAUTILUS and a list of Gamma Ray Bursts (GRBs) detected
by the satellite experiments BATSE and BeppoSAX has been analyzed using
cumulative algorithms. GW detector data collected between 1991 and 1999 have
been correlated to the GRB flux peak times. The cumulative analysis of a large
number of GRBs (387) allows to push the upper bound for the corresponding GW
burst amplitude down to $h = 2.5\cdot10^{-19}$.
[7]
oai:arXiv.org:gr-qc/0210053 [pdf] - 398744
Study of the coincidences between the gravitational wave detectors
EXPLORER and NAUTILUS in 2001
Astone, P.;
Babusci, D.;
Bassan, M.;
Bonifazi, P.;
Carelli, P.;
Cavallari, G.;
Coccia, E.;
Cosmelli, C.;
D'Antonio, S.;
Fafone, V.;
Federici, G.;
Frasca, S.;
Giordano, G.;
Marini, A.;
Minenkov, Y.;
Modena, I.;
Modestino, G.;
Moleti, A.;
Pallottino, G. V.;
Pizzella, G.;
Quintieri, L.;
Rocchi, A.;
Ronga, F.;
Terenzi, R.;
Torrioli, G.;
Visco, M.
Submitted: 2002-10-17
We report the result from a search for bursts of gravitational waves using
data collected by the cryogenic resonant detectors EXPLORER and NAUTILUS during
the year 2001, for a total measuring time of 90 days. With these data we
repeated the coincidence search performed on the 1998 data (which showed a
small coincidence excess) applying data analysis algorithms based on known
physical characteristics of the detectors. With the 2001 data a new interesting
coincidence excess is found when the detectors are favorably oriented with
respect to the Galactic Disk.
[8]
oai:arXiv.org:astro-ph/0206431 [pdf] - 50062
Search for correlation between GRB's detected by BeppoSAX and
gravitational wave detectors EXPLORER and NAUTILUS
Astone, P.;
Bassan, M.;
Bonifazi, P.;
Carelli, P.;
Castellano, G.;
Coccia, E.;
Cosmelli, C.;
D'Agostini, G.;
D'Antonio, S.;
Fafone, V.;
Federici, G.;
Frontera, F.;
Guidorzi, C.;
Marini, A.;
Minenkov, Y.;
Modena, I.;
Modestino, G.;
Moleti, A.;
Montanari, E.;
Pallottino, G. V.;
Pizzella, G.;
Quintieri, L.;
Rocchi, A.;
Ronga, F.;
Rocchi, A.;
Terenzi, R.;
Torrioli, G.;
Visco, M.
Submitted: 2002-06-25, last modified: 2002-07-12
Data obtained during five months of 2001 with the gravitational wave (GW)
detectors EXPLORER and NAUTILUS were studied in correlation with the gamma ray
burst data (GRB) obtained with the BeppoSAX satellite. During this period
BeppoSAX was the only GRB satellite in operation, while EXPLORER and NAUTILUS
were the only GW detectors in operation.
No correlation between the GW data and the GRB bursts was found. The
analysis, performed over 47 GRB's, excludes the presence of signals of
amplitude h >=1.2 * 10^{-18}, with 95 % probability, if we allow a time delay
between GW bursts and GRB within +-400 s, and h >= 6.5 * 10^{-19}, if the time
delay is within +- 5 s. The result is also provided in form of scaled
likelihood for unbiased interpretation and easier use for further analysis.