Normalized to: Torres, K.
[1]
oai:arXiv.org:1803.01452 [pdf] - 1645897
The when and where of water in the history of the universe
Submitted: 2018-03-04
It is undeniable that life as we know it depends on liquid water. It is
difficult to imagine any biochemical machinery that does not require water. On
Earth, life adapts to the most diverse environments and, once established, it
is very resilient. Considering that water is a common compound in the Universe,
it seems possible (maybe even likely) that one day we will find life elsewhere
in the universe. In this study, we review the main aspects of water as an
essential compound for life: when it appeared since the Big Bang, and where it
spread throughout the diverse cosmic sites. Then, we describe the strong
relation between water and life, as we know it.
[2]
oai:arXiv.org:1611.03066 [pdf] - 1561044
First Direct-Detection Constraints on eV-Scale Hidden-Photon Dark Matter
with DAMIC at SNOLAB
Aguilar-Arevalo, A.;
Amidei, D.;
Bertou, X.;
Butner, M.;
Cancelo, G.;
Vázquez, A. Castañeda;
Vergara, B. A. Cervantes;
Chavarria, A. E.;
Chavez, C. R.;
Neto, J. R. T. de Mello;
D'Olivo, J. C.;
Estrada, J.;
Moroni, G. Fernandez;
Gaïor, R.;
Guardincerri, Y.;
Torres, K. P. Hernández;
Izraelevitch, F.;
Kavner, A.;
Kilminster, B.;
Lawson, I.;
Letessier-Selvon, A.;
Liao, J.;
Matalon, A.;
Mello, V. B. B.;
Molina, J.;
Privitera, P.;
Ramanathan, K.;
Sarkis, Y.;
Schwarz, T.;
Settimo, M.;
Haro, M. Sofo;
Thomas, R.;
Tiffenberg, J.;
Tiouchichine, E.;
Machado, D. Torres;
Trillaud, F.;
You, X.;
Zhou, J.
Submitted: 2016-11-09, last modified: 2017-04-11
We present direct detection constraints on the absorption of hidden-photon
dark matter with particle masses in the range 1.2-30 eV$c^{-2}$ with the DAMIC
experiment at SNOLAB. Under the assumption that the local dark matter is
entirely constituted of hidden photons, the sensitivity to the kinetic mixing
parameter $\kappa$ is competitive with constraints from solar emission,
reaching a minimum value of 2.2$\times$$10^{-14}$ at 17 eV$c^{-2}$. These
results are the most stringent direct detection constraints on hidden-photon
dark matter in the galactic halo with masses 3-12 eV$c^{-2}$ and the first
demonstration of direct experimental sensitivity to ionization signals $<$12 eV
from dark matter interactions.
[3]
oai:arXiv.org:1607.07410 [pdf] - 1511851
Search for low-mass WIMPs in a 0.6 kg day exposure of the DAMIC
experiment at SNOLAB
Aguilar-Arevalo, A.;
Amidei, D.;
Bertou, X.;
Butner, M.;
Cancelo, G.;
Vázquez, A. Castañeda;
Vergara, B. A. Cervantes;
Chavarria, A. E.;
Chavez, C. R.;
Neto, J. R. T. de Mello;
D'Olivo, J. C.;
Estrada, J.;
Moroni, G. Fernandez;
Gaïor, R.;
Guandincerri, Y.;
Torres, K. P. Hernández;
Izraelevitch, F.;
Kavner, A.;
Kilminster, B.;
Lawson, I.;
Letessier-Selvon, A.;
Liao, J.;
Molina, J.;
Peña, J. R.;
Privitera, P.;
Ramanathan, K.;
Sarkis, Y.;
Schwarz, T.;
Sengul, C.;
Settimo, M.;
Haro, M. Sofo;
Thomas, R.;
Tiffenberg, J.;
Tiouchichine, E.;
Machado, D. Torres;
Trillaud, F.;
You, X.;
Zhou, J.
Submitted: 2016-07-25, last modified: 2016-11-09
We present results of a dark matter search performed with a 0.6 kg day
exposure of the DAMIC experiment at the SNOLAB underground laboratory. We
measure the energy spectrum of ionization events in the bulk silicon of
charge-coupled devices down to a signal of 60 eV electron equivalent. The data
are consistent with radiogenic backgrounds, and constraints on the
spin-independent WIMP-nucleon elastic-scattering cross section are accordingly
placed. A region of parameter space relevant to the potential signal from the
CDMS-II Si experiment is excluded using the same target for the first time.
This result obtained with a limited exposure demonstrates the potential to
explore the low-mass WIMP region (<10 GeV/$c^{2}$) of the upcoming DAMIC100, a
100 g detector currently being installed in SNOLAB.
[4]
oai:arXiv.org:1510.00044 [pdf] - 1323491
Status of the DAMIC direct dark matter search experiment
DAMIC Collaboration;
Aguilar-Arevalo, A.;
Amidei, D.;
Bertou, X.;
Boule, D.;
Butner, M.;
Cancelo, G.;
Vázquez, A. Castañeda;
Chavarría, A. E.;
Neto, J. R. T. de Melo;
Dixon, S.;
D'Olivo, J. C.;
Estrada, J.;
Moroni, G. Fernandez;
Torres, K. P. Hernández;
Izraelevitch, F.;
Kavner, A.;
Kilminster, B.;
Lawson, I.;
Liao, J.;
López, M.;
Molina, J.;
Moreno-Granados, G.;
Pena, J.;
Privitera, P.;
Sarkis, Y.;
Scarpine, V.;
Schwartz, T.;
Haro, M. Sofo;
Tiffenberg, J.;
Machado, D. Torres;
Trillaud, F.;
You, X.;
Zhou, J.
Submitted: 2015-09-30, last modified: 2015-12-08
The DAMIC experiment uses fully depleted, high resistivity CCDs to search for
dark matter particles. With an energy threshold $\sim$50 eV$_{ee}$, and
excellent energy and spatial resolutions, the DAMIC CCDs are well-suited to
identify and suppress radioactive backgrounds, having an unrivaled sensitivity
to WIMPs with masses $<$6 GeV/$c^2$. Early results motivated the construction
of a 100 g detector, DAMIC100, currently being installed at SNOLAB. This
contribution discusses the installation progress, new calibration efforts near
the threshold, a preliminary result with 2014 data, and the prospects for
physics results after one year of data taking.
[5]
oai:arXiv.org:1510.02126 [pdf] - 1449866
The DAMIC dark matter experiment
Aguilar-Arevalo, A.;
Amidei, D.;
Bertou, X.;
Bole, D.;
Butner, M.;
Cancelo, G.;
Vázquez, A. Castañeda;
Chavarria, A. E.;
Neto, J. R. T. de Mello;
Dixon, S.;
D'Olivo, J. C.;
Estrada, J.;
Moroni, G. Fernandez;
Torres, K. P. Hernández;
Izraelevitch, F.;
Kavner, A.;
Kilminster, B.;
Lawson, I.;
Liao, J.;
López, M.;
Molina, J.;
Moreno-Granados, G.;
Pena, J.;
Privitera, P.;
Sarkis, Y.;
Scarpine, V.;
Schwarz, T.;
Haro, M. Sofo;
Tiffenberg, J.;
Machado, D. Torres;
Trillaud, F.;
You, X.;
Zhou, J.
Submitted: 2015-10-07
The DAMIC (Dark Matter in CCDs) experiment uses high resistivity, scientific
grade CCDs to search for dark matter. The CCD's low electronic noise allows an
unprecedently low energy threshold of a few tens of eV that make it possible to
detect silicon recoils resulting from interactions of low mass WIMPs. In
addition the CCD's high spatial resolution and the excellent energy response
results in very effective background identification techniques. The experiment
has a unique sensitivity to dark matter particles with masses below 10
GeV/c$^2$. Previous results have demonstrated the potential of this technology,
motivating the construction of DAMIC100, a 100 grams silicon target detector
currently being installed at SNOLAB. In this contribution, the mode of
operation and unique imaging capabilities of the CCDs, and how they may be
exploited to characterize and suppress backgrounds will be discussed, as well
as physics results after one year of data taking.
[6]
oai:arXiv.org:1506.02562 [pdf] - 1505514
Measurement of radioactive contamination in the high-resistivity silicon
CCDs of the DAMIC experiment
Aguilar-Arevalo, A.;
Amidei, D.;
Bertou, X.;
Bole, D.;
Butner, M.;
Cancelo, G.;
Vázquez, A. Castañeda;
Chavarria, A. E.;
Neto, J. R. T. de Mello;
Dixon, S.;
D'Olivo, J. C.;
Estrada, J.;
Moroni, G. Fernandez;
Torres, K. P. Hernández;
Izraelevitch, F.;
Kavner, A.;
Kilminster, B.;
Lawson, I.;
Liao, J.;
López, M.;
Molina, J.;
Moreno-Granados, G.;
Pena, J.;
Privitera, P.;
Sarkis, Y.;
Scarpine, V.;
Schwarz, T.;
Haro, M. Sofo;
Tiffenberg, J.;
Machado, D. Torres;
Trillaud, F.;
You, X.;
Zhou, J.
Submitted: 2015-06-08, last modified: 2015-07-09
We present measurements of radioactive contamination in the high-resistivity
silicon charge-coupled devices (CCDs) used by the DAMIC experiment to search
for dark matter particles. Novel analysis methods, which exploit the unique
spatial resolution of CCDs, were developed to identify $\alpha$ and $\beta$
particles. Uranium and thorium contamination in the CCD bulk was measured
through $\alpha$ spectroscopy, with an upper limit on the $^{238}$U
($^{232}$Th) decay rate of 5 (15) kg$^{-1}$ d$^{-1}$ at 95% CL. We also
searched for pairs of spatially correlated electron tracks separated in time by
up to tens of days, as expected from $^{32}$Si-$^{32}$P or
$^{210}$Pb-$^{210}$Bi sequences of $\beta$ decays. The decay rate of $^{32}$Si
was found to be $80^{+110}_{-65}$ kg$^{-1}$ d$^{-1}$ (95% CI). An upper limit
of $\sim$35 kg$^{-1}$ d$^{-1}$ (95% CL) on the $^{210}$Pb decay rate was
obtained independently by $\alpha$ spectroscopy and the $\beta$ decay sequence
search. These levels of radioactive contamination are sufficiently low for the
successful operation of CCDs in the forthcoming 100 g DAMIC detector.
[7]
oai:arXiv.org:1302.1233 [pdf] - 1159530
A Compound model for the origin of Earth's water
Submitted: 2013-02-05, last modified: 2013-02-26
One of the most important subjects of debate in the formation of the solar
system is the origin of Earth's water. Comets have long been considered as the
most likely source of the delivery of water to Earth. However, elemental and
isotopic arguments suggest a very small contribution from these objects. Other
sources have also been proposed, among which, local adsorption of water vapor
onto dust grains in the primordial nebula and delivery through planetesimals
and planetary embryos have become more prominent. However, no sole source of
water provides a satisfactory explanation for Earth's water as a whole. In view
of that, using numerical simulations, we have developed a compound model
incorporating both the principal endogenous and exogenous theories, and
investigating their implications for terrestrial planet formation and
water-delivery. Comets are also considered in the final analysis, as it is
likely that at least some of Earth's water has cometary origin. We analyze our
results comparing two different water distribution models, and complement our
study using D/H ratio, finding possible relative contributions from each
source, focusing on planets formed in the habitable zone. We find that the
compound model play an important role by showing more advantage in the amount
and time of water-delivery in Earth-like planets.
[8]
oai:arXiv.org:1012.5211 [pdf] - 1042749
Long-term Spectroscopic Monitoring of LBVs and LBV Candidates
Submitted: 2010-12-23
We present results of a long-term spectroscopic monitoring program (since mid
2009) of Luminous Blue Variables with the new HERMES echelle spectrograph on
the 1.2 m Mercator telescope at La Palma (Spain). We investigate
high-resolution (R=80,000) optical spectra of two LBVs, P Cyg and HD 168607,
the LBV candidates MWC 930 and HD 168625, and the LBV binary MWC 314. In P Cyg
we observe flux changes in the violet wings of the Balmer H{\alpha}, H{\beta},
and He I lines between May and Sep 2009. The changes around 200 km/s to 300
km/s are caused by variable opacity at the base of the supersonic wind from the
blue supergiant. We observe in MWC 314 broad double-peaked metal emission lines
with invariable radial velocities over time. On the other hand, we measure in
the photospheric S II {\lambda}5647 absorption line, with lower excitation
energy of ~14 eV, an increase of the heliocentric radial velocity centroid from
37 km/s to 70 km/s between 5 and 10 Sep 2009 (and 43 km/s on 6 Apr 2010). The
increase of radial velocity of ~33 km/s in only 5 days can confirm the binary
nature of this LBV close to the Eddington luminosity limit. A comparison with
VLT-UVES and Keck-Hires spectra observed over the past 13 years reveals strong
flux variability in the violet wing of the H{\alpha} emission line of HD
168625, and in the absorption portion of the H{\beta} line of HD 168607. In HD
168625 we observe H{\alpha} wind absorption at velocities exceeding 200 km/s
which develops between Apr and June 2010.
[9]
oai:arXiv.org:1010.5643 [pdf] - 1041567
Spectra disentangling applied to the Hyades binary Theta^2 Tau AB: new
orbit, orbital parallax and component properties
Submitted: 2010-10-27
Theta^2 Tauri is a detached and single-lined interferometric-spectroscopic
binary as well as the most massive binary system of the Hyades cluster. The
system revolves in an eccentric orbit with a periodicity of 140.7 days. The
secondary has a similar temperature but is less evolved and fainter than the
primary. It is also rotating more rapidly. Since the composite spectra are
heavily blended, the direct extraction of radial velocities over the orbit of
component B was hitherto unsuccessful. Using high-resolution spectroscopic data
recently obtained with the Elodie (OHP, France) and Hermes (ORM, La Palma,
Spain) spectrographs, and applying a spectra disentangling algorithm to three
independent data sets including spectra from the Oak Ridge Observatory (USA),
we derived an improved spectroscopic orbit and refined the solution by
performing a combined astrometric-spectroscopic analysis based on the new
spectroscopy and the long-baseline data from the Mark III optical
interferometer. As a result, the velocity amplitude of the fainter component is
obtained in a direct and objective way. Major progress based on this new
determination includes an improved computation of the orbital parallax. Our
mass ratio is in good agreement with the older estimates of Peterson et al.
(1991, 1993), but the mass of the primary is 15-25% higher than the more recent
estimates by Torres et al. (1997) and Armstrong et al. (2006). Due to the
strategic position of the components in the turnoff region of the cluster,
these new determinations imply stricter constraints for the age and the
metallicity of the Hyades cluster. The location of component B can be explained
by current evolutionary models, but the location of the more evolved component
A is not trivially explained and requires a detailed abundance analysis of its
disentangled spectrum.
[10]
oai:arXiv.org:0808.0483 [pdf] - 15128
Symplectic Integrator Mercury: Bug Report
Submitted: 2008-08-04
We report on a problem found in MERCURY, a hybrid symplectic integrator used
for dynamical problems in Astronomy. The variable that keeps track of bodies'
statuses is uninitialised, which can result in bodies disappearing from
simulations in a non-physical manner. Some FORTRAN compilers implicitly
initialise variables, preventing simulations from having this problem. With
other compilers, simulations with a suitably large maximum number of bodies
parameter value are also unaffected. Otherwise, the problem manifests at the
first event after the integrator is started, whether from scratch or continuing
a previously stopped simulation. Although the problem does not manifest in some
conditions, explicitly initialising the variable solves the problem in a
permanent and unconditional manner.