Normalized to: Tomura, A.
[1]
oai:arXiv.org:2003.10672 [pdf] - 2086476
Frequency-Dependent Squeezed Vacuum Source for Broadband Quantum Noise
Reduction in Advanced Gravitational-Wave Detectors
Zhao, Yuhang;
Aritomi, Naoki;
Capocasa, Eleonora;
Leonardi, Matteo;
Eisenmann, Marc;
Guo, Yuefan;
Polini, Eleonora;
Tomura, Akihiro;
Arai, Koji;
Aso, Yoichi;
Huang, Yao-Chin;
Lee, Ray-Kuang;
Lück, Harald;
Miyakawa, Osamu;
Prat, Pierre;
Shoda, Ayaka;
Tacca, Matteo;
Takahashi, Ryutaro;
Vahlbruch, Henning;
Vardaro, Marco;
Wu, Chien-Ming;
Barsuglia, Matteo;
Flaminio, Raffaele
Submitted: 2020-03-24, last modified: 2020-04-28
The astrophysical reach of current and future ground-based gravitational-wave
detectors is mostly limited by quantum noise, induced by vacuum fluctuations
entering the detector output port. The replacement of this ordinary vacuum
field with a squeezed vacuum field has proven to be an effective strategy to
mitigate such quantum noise and it is currently used in advanced detectors.
However, current squeezing cannot improve the noise across the whole spectrum
because of the Heisenberg uncertainty principle: when shot noise at high
frequencies is reduced, radiation pressure at low frequencies is increased. A
broadband quantum noise reduction is possible by using a more complex squeezing
source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity,
known as filter cavity. Here we report the first demonstration of a
frequency-dependent squeezed vacuum source able to reduce quantum noise of
advanced gravitational-wave detectors in their whole observation bandwidth. The
experiment uses a suspended 300-m-long filter cavity, similar to the one
planned for KAGRA, Advanced Virgo and Advanced LIGO, and capable of inducing a
rotation of the squeezing ellipse below 100 Hz.
[2]
oai:arXiv.org:1806.10506 [pdf] - 1732761
Measurement of optical losses in a high-finesse 300 m filter cavity for
broadband quantum noise reduction in gravitational-wave detectors
Capocasa, Eleonora;
Guo, Yuefan;
Eisenmann, Marc;
Zhao, Yuhang;
Tomura, Akihiro;
Arai, Koji;
Aso, Yoichi;
Marchiò, Manuel;
Pinard, Laurent;
Prat, Pierre;
Somiya, Kentaro;
Schnabel, Roman;
Tacca, Matteo;
Takahashi, Ryutaro;
Tatsumi, Daisuke;
Leonardi, Matteo;
Barsuglia, Matteo;
Flaminio, Raffaele
Submitted: 2018-06-27
Earth-based gravitational-wave detectors will be limited by quantum noise in
a large part of their spectrum. The most promising technique to achieve a
broadband reduction of such noise is the injection of a frequency dependent
squeezed vacuum state from the output port of the detector, whit the squeeze
angle rotated by the reflection off a Fabry-Perot filter cavity. One of the
most important parameters limiting the squeezing performance is represented by
the optical losses of the filter cavity. We report here the operation of a 300
m filter cavity prototype installed at the National Astronomical Observatory of
Japan (NAOJ). The cavity is designed to obtain a rotation of the squeeze angle
below 100 Hz. After achieving the resonance of the cavity with a
multi-wavelength technique, the round trip losses have been measured to be
between 50 ppm and 90 ppm. This result demonstrates that with realistic
assumption on the input squeeze factor and on the other optical losses, a
quantum noise reduction of at least 4 dB in the frequency region dominated by
radiation pressure can be achieved.