sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Tomas, A.

Normalized to: Tomas, A.

5 article(s) in total. 187 co-authors, from 1 to 4 common article(s). Median position in authors list is 20,0.

[1]  oai:arXiv.org:1910.11061  [pdf] - 1985837
The EarthASAP mission concept for a Lunar orbiting cubesat
Comments:
Submitted: 2019-10-24
There is a growing interest in Lunar exploration fed by the perception that the Moon can be made accessible to low-cost missions in the next decade. The on-going projects to set a communications relay in Lunar orbit and a deep space Gateway, as well as the spreading of commercial-of-the shelf (COTS) technology for small space platforms such as the cubesats contribute to this perception. Small, cubesat size satellites orbiting the Moon offer ample opportunities to study the Moon and enjoy an advantage point to monitor the Solar System and the large scale interaction between the Earth and the solar wind. In this article, we describe the technical characteristics of a 12U cubesat to be set in polar Lunar orbit for this purpose and the science behind it. The mission is named EarthASAP (Earth AS An exoPlanet) and was submitted to the Lunar Cubesats for Exploration (LUCE) call in 2016. EarthASAP was designed to monitor hydrated rock reservoirs in the Lunar poles and to study the interaction between the large Earth's exosphere and the solar wind in preparation for future exoplanetary missions.
[2]  oai:arXiv.org:1501.01466  [pdf] - 918435
Lowering the background level and the energy threshold of Micromegas x-ray detectors for axion searches
Comments: Proceedings of 3rd International Conference on Technology and Instrumentation in Particle Physics (TIPP 2014)
Submitted: 2015-01-07
Axion helioscopes search for solar axions by their conversion in x-rays in the presence of high magnetic fields. The use of low background x-ray detectors is an essential component contributing to the sensitivity of these searches. In this work, we review the recent advances on Micromegas detectors used in the CERN Axion Solar Telescope (CAST) and proposed for the future International Axion Observatory (IAXO). The actual setup in CAST has achieved background levels below 10$^{-6}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$, a factor 100 lower than the first generation of Micromegas detectors. This reduction is based on active and passive shielding techniques, the selection of radiopure materials, offline discrimination techniques and the high granularity of the readout. We describe in detail the background model of the detector, based on its operation at CAST site and at the Canfranc Underground Laboratory (LSC), as well as on Geant4 simulations. The best levels currently achieved at LSC are low than 10$^{-7}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$ and show good prospects for the application of this technology in IAXO. Finally, we present some ideas and results for reducing the energy threshold of these detectors below 1 keV, using high-transparent windows, autotrigger electronics and studying the cluster shape at different energies. As a high flux of axion-like-particles is expected in this energy range, a sub-keV threshold detector could enlarge the physics case of axion helioscopes.
[3]  oai:arXiv.org:1307.1985  [pdf] - 867037
CAST solar axion search with 3^He buffer gas: Closing the hot dark matter gap
Comments: 5 pages, 2 figures. Last version uploaded
Submitted: 2013-07-08, last modified: 2014-09-15
The CERN Axion Solar Telescope (CAST) has finished its search for solar axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV. This closes the gap to the cosmological hot dark matter limit and actually overlaps with it. From the absence of excess X-rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g_ag < 3.3 x 10^{-10} GeV^{-1} at 95% CL, with the exact value depending on the pressure setting. Future direct solar axion searches will focus on increasing the sensitivity to smaller values of g_a, for example by the currently discussed next generation helioscope IAXO.
[4]  oai:arXiv.org:1110.2608  [pdf] - 1084811
Low X-ray bakground measurements at the Underground Canfranc Laboratory
Comments: Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011
Submitted: 2011-10-12, last modified: 2011-10-25
Micromegas detectors, thanks to the good spatial and temporal discrimination capabilities, are good candidates for rare event search experiments. Recent X-ray background levels achieved by these detectors in the CAST experiment have motivated further studies in the nature of the background levels measured. In particular, different shielding configurations have been tested at the Canfranc Underground Laboratory, using a microbulk type detector which was previously running at the CAST experiment. The first results underground show that this technology, which is made of low radiative materials, is able to reach background levels up to $2 \times 10^{-7}$keV$^{-1}$s$^{-1}$cm$^{-2}$ with a proper shielding. Moreover, the experimental background measurements are complemented with Geant4 simulations which allow to understand the origin of the background, and to optimize future shielding set-ups.
[5]  oai:arXiv.org:0911.0323  [pdf] - 902277
The case for a directional dark matter detector and the status of current experimental efforts
Comments: 48 pages, 37 figures, whitepaper on direct dark matter detection with directional sensitivity
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.