sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Tobar, M. E.

Normalized to: Tobar, M.

18 article(s) in total. 224 co-authors, from 1 to 8 common article(s). Median position in authors list is 2,5.

[1]  oai:arXiv.org:2004.06984  [pdf] - 2118959
Broadband Electrical Action Sensing Techniques with conducting wires for low-mass dark matter axion detection
Comments: Final accepted journal version. Two misconceptions fixed as required by referee compared to last version. Additions are in color, red for one point of misconception and blue for the other point
Submitted: 2020-04-15, last modified: 2020-06-10
Due to the inverse Primakoff effect it has been shown that when axions interact with a DC magnetic B-field the resulting electrical action will produce an AC electromotive force which oscillates at the Compton frequency of the axion, and may be modeled as an oscillating effective impressed magnetic current boundary source. We use this result to calculate the sensitivity of new experiments to low-mass axions using the quasi-static technique. First, we calculate the current induced in an electric dipole antenna (straight conducting wire) when the DC B-field is spatially constant and show that it has a sensitivity proportional to the axion mass. Following this we extend the topology by making use of the full extent of the spatially varying DC B-field. This extension is achieved by transforming the 1D conducting wire to a 2D winding, to fully link the effective magnetic current boundary source and thus couple to the full axion induced electrical action. In this case the conductor becomes a coil winding where the voltage induced across the winding increases proportionally to the number of windings. We investigate two different topologies: The 1st uses a single winding, and couples to the effective short circuit current generated in the winding, which is read out using a sensitive low impedance SQUID amplifier: The 2nd uses multiple windings, with every turn effectively increasing the the voltage output proportional to the winding number. The read out of this configuration is optimised by implementing a cryogenic low-noise high input impedance voltage amplifier. The end result is a new Broadband Electrical Action Sensing Techniques with orders of magnitude improved sensitivity, which is linearly proportional to the axion photon coupling and capable of detecting QCD dark matter axions.
[2]  oai:arXiv.org:2005.02546  [pdf] - 2109111
Methods for coherent optical Doppler orbitography
Comments: 10 pages, 6 figures, 1 table
Submitted: 2020-05-05, last modified: 2020-06-07
Doppler orbitography uses the Doppler shift in a transmitted signal to determine the orbital parameters of satellites including range and range-rate (or radial velocity). We describe two techniques for atmospheric-limited optical Doppler orbitography measurements of range-rate. The first determines the Doppler shift directly from a heterodyne measurement of the returned optical signal. The second aims to improve the precision of the first by suppressing atmospheric phase noise imprinted on the transmitted optical signal. We demonstrate the performance of each technique over a 2.2 km horizontal link with a simulated in-line velocity Doppler shift at the far end. A horizontal link of this length has been estimated to exhibit nearly half the total integrated atmospheric turbulence of a vertical link to space. Without stabilisation of the atmospheric effects, we obtained an estimated range rate precision of 17 um/s at 1 s of integration. With active suppression of atmospheric phase noise, this improved by three orders-of-magnitude to an estimated range rate precision of 9.0 nm/s at 1 second of integration, and 1.1 nm/s when integrated over a 60 s. This represents four orders-of-magnitude improvement over the typical performance of operational ground to space X-Band systems in terms of range-rate precision at the same integration time. The performance of this system is a promising proof of concept for coherent optical Doppler orbitography. There are many additional challenges associated with performing these techniques from ground to space, that were not captured within the preliminary experiments presented here. In the future, we aim to progress towards a 10 km horizontal link to replicate the expected atmospheric turbulence for a ground to space link.
[3]  oai:arXiv.org:1809.01654  [pdf] - 1926879
Modified Axion Electrodynamics as Impressed Electromagnetic Sources Through Oscillating Background Polarization and Magnetization
Comments: Final corrected published version
Submitted: 2018-09-05, last modified: 2019-07-31
We present a reformulation of axion modified electrodynamics with all modifications redefined within the constitutive relations between the D,H,B and E fields. This allows the interpretation of the axion induced background bound charge, polarization current and background polarization and magnetization satisfying the charge-current continuity equation. This representation is of similar form to photon sector odd-parity Lorentz invariance violating background fields. We show that when a DC B-field is applied an oscillating background polarization is induced at a frequency equivalent to the axion mass. In contrast, when DC E-field is applied, an oscillating background magnetization is induced at a frequency equivalent to the axion mass. We show that these terms are equivalent to impressed source terms, analogous to the way that voltage and current sources are impressed into Maxwell's equations in circuit and antenna theory. The impressed source terms represent the conversion of external energy into electromagnetic energy, and in the case of axion modified electrodynamics this is due to the inverse Primakoff effect converting energy from axions into photons. The axion induced oscillating polarization under a DC magnetic field is analogous to a permanent polarised electret oscillating at the axion Compton frequency, which sources an electromotive force from an effective impressed magnetic current source. In particular, it is shown that the impressed electrical DC current that drives the solenoidal magnetic DC field of an electromagnet, induces an impressed magnetic current parallel to the DC electrical current, oscillating at the Compton frequency of the axion. We show that the magnetic current drives a voltage source through an electric vector potential and also defines the boundary condition of the oscillating axion induced polarization inside and outside the electromagnet.
[4]  oai:arXiv.org:1703.02179  [pdf] - 1581784
Sensitivity Characterisation of a Parametric Transducer for Gravitational Wave Detection Through Optical Spring Effect
Comments:
Submitted: 2017-03-06, last modified: 2017-07-24
We present the characterisation of the most recent parametric transducers designed to enhance the Mario Schenberg Gravitational Wave Detector sensitivity. The transducer is composed of a microwave re-entrant cavity that attaches to the gravitational wave antenna via a rigid spring. It functions as a three-mode mass-spring system; motion of the spherical antenna couples to a 50 $\mu m$ thick membrane, which converts its mechanical motion into a frequency shift of the cavity resonance. Through the optical spring effect, the microwave transducer frequency-displacement sensitivity was measured to be 726 $MHz/\mu$m at 4 K. The spherical antenna detection sensitivity is determined analytically using the transducer amplification gain and equivalent displacement noise in the test setup, which are 5.5 $\times$ 10$^{11} V/m$ and $1.8 \times 10^{-19} m\sqrt{Hz}^{-1}$, respectively.
[5]  oai:arXiv.org:1512.05547  [pdf] - 1420880
Axion Dark Matter Coupling to Resonant Photons via Magnetic Field
Comments: 5 pages, 4 figures. Version 2/3: Corrected typographical errors. Version 4: Final version as published in Physical Review Letters
Submitted: 2015-12-17, last modified: 2016-06-09
We show that the magnetic component of the photon field produced by dark matter axions via the two-photon coupling mechanism in a Sikivie Haloscope is an important parameter passed over in previous analysis and experiments. The interaction of the produced photons will be resonantly enhanced as long as they couple to the electric or magnetic mode structure of the Haloscope cavity. For typical Haloscope experiments the electric and magnetic coupling is the same and implicitly assumed in past sensitivity calculations. However, for future planned searches such as those at high frequency, which synchronize multiple cavities, the sensitivity will be altered due to different magnetic and electric couplings. We define the complete electromagnetic form factor and discuss its implications for current and future high and low mass axion searches, including some effects which have been overlooked, due to the assumption that the two couplings are the same.
[6]  oai:arXiv.org:1311.0029  [pdf] - 741002
Dark Sectors and New, Light, Weakly-Coupled Particles
Comments: Report of the Community Summer Study 2013 (Snowmass) Intensity Frontier New, Light, Weakly-Coupled Particles subgroup
Submitted: 2013-10-31
Dark sectors, consisting of new, light, weakly-coupled particles that do not interact with the known strong, weak, or electromagnetic forces, are a particularly compelling possibility for new physics. Nature may contain numerous dark sectors, each with their own beautiful structure, distinct particles, and forces. This review summarizes the physics motivation for dark sectors and the exciting opportunities for experimental exploration. It is the summary of the Intensity Frontier subgroup "New, Light, Weakly-coupled Particles" of the Community Summer Study 2013 (Snowmass). We discuss axions, which solve the strong CP problem and are an excellent dark matter candidate, and their generalization to axion-like particles. We also review dark photons and other dark-sector particles, including sub-GeV dark matter, which are theoretically natural, provide for dark matter candidates or new dark matter interactions, and could resolve outstanding puzzles in particle and astro-particle physics. In many cases, the exploration of dark sectors can proceed with existing facilities and comparatively modest experiments. A rich, diverse, and low-cost experimental program has been identified that has the potential for one or more game-changing discoveries. These physics opportunities should be vigorously pursued in the US and elsewhere.
[7]  oai:arXiv.org:1106.0021  [pdf] - 367770
Adapting a Cryogenic Sapphire Oscillator for Very Long Baseline Interferometry
Comments: 24 pages, 15 figures
Submitted: 2011-05-31
Extension of very long baseline interferometry (VLBI) to observing wavelengths shorter than 1.3mm provides exceptional angular resolution (~20 micro arcsec) and access to new spectral regimes for the study of astrophysical phenomena. To maintain phase coherence across a global VLBI array at these wavelengths requires that ultrastable frequency references be used for the heterodyne receivers at all participating telescopes. Hydrogen masers have traditionally been used as VLBI references, but atmospheric turbulence typically limits (sub) millimeter VLBI coherence times to ~1-30 s. Cryogenic Sapphire Oscillators (CSO) have better stability than Hydrogen masers on these time scale and are potential alternatives to masers as VLBI references. Here, We describe the design, implementation and tests of a system to produce a 10 MHz VLBI frequency standard from the microwave (11.2 GHz) output of a CSO. To improve long-term stability of the new reference, the CSO was locked to the timing signal from the Global Positioning System satellites and corrected for the oscillator aging. The long-term performance of the CSO was measured by comparison against a hydrogen maser in the same laboratory. The superb short-term performance, along with the improved long-term performance achieved by conditioning, makes the CSO a suitable reference for VLBI at wavelengths less than 1.3mm.
[8]  oai:arXiv.org:0711.0304  [pdf] - 6649
Quantum Physics Exploring Gravity in the Outer Solar System: The Sagas Project
Comments: 39 pages. Submitted in abridged version to Experimental Astronomy
Submitted: 2007-11-02, last modified: 2008-08-12
We summarise the scientific and technological aspects of the SAGAS (Search for Anomalous Gravitation using Atomic Sensors) project, submitted to ESA in June 2007 in response to the Cosmic Vision 2015-2025 call for proposals. The proposed mission aims at flying highly sensitive atomic sensors (optical clock, cold atom accelerometer, optical link) on a Solar System escape trajectory in the 2020 to 2030 time-frame. SAGAS has numerous science objectives in fundamental physics and Solar System science, for example numerous tests of general relativity and the exploration of the Kuiper belt. The combination of highly sensitive atomic sensors and of the laser link well adapted for large distances will allow measurements with unprecedented accuracy and on scales never reached before. We present the proposed mission in some detail, with particular emphasis on the science goals and associated measurements.
[9]  oai:arXiv.org:gr-qc/0609072  [pdf] - 112320
Improved test of Lorentz Invariance in Electrodynamics using Rotating Cryogenic Sapphire Oscillators
Comments: Accepted for publication in Phys. Rev. D
Submitted: 2006-09-19, last modified: 2006-10-03
We present new results from our test of Lorentz invariance, which compares two orthogonal cryogenic sapphire microwave oscillators rotating in the lab. We have now acquired over 1 year of data, allowing us to avoid the short data set approximation (less than 1 year) that assumes no cancelation occurs between the $\tilde{\kappa}_{e-}$ and $\tilde{\kappa}_{o+}$ parameters from the photon sector of the standard model extension. Thus, we are able to place independent limits on all eight $\tilde{\kappa}_{e-}$ and $\tilde{\kappa}_{o+}$ parameters. Our results represents up to a factor of 10 improvement over previous non rotating measurements (which independently constrained 7 parameters), and is a slight improvement (except for $\tilde{\kappa}_{e-}^{ZZ}$) over results from previous rotating experiments that assumed the short data set approximation. Also, an analysis in the Robertson-Mansouri-Sexl framework allows us to place a new limit on the isotropy parameter $P_{MM}=\delta-\beta+{1/2}$ of $9.4(8.1)\times10^{-11}$, an improvement of a factor of 2.
[10]  oai:arXiv.org:gr-qc/0603067  [pdf] - 112131
Properties of gravitational waves in Cosmological General Relativity
Comments: 10 pages, 1 figure, accepted for publication in IJTP, corrected typos
Submitted: 2006-03-16, last modified: 2006-08-04
The 5D Cosmological General Relativity theory developed by Carmeli reproduces all of the results that have been successfully tested for Einstein's 4D theory. However the Carmeli theory because of its fifth dimension, the velocity of the expanding universe, predicts something different for the propagation of gravity waves on cosmological distance scales. This analysis indicates that gravitational radiation may not propagate as an unattenuated wave where effects of the Hubble expansion are felt. In such cases the energy does not travel over such large length scales but is evanescent and dissipated into the surrounding space as heat.
[11]  oai:arXiv.org:hep-ph/0506200  [pdf] - 265407
Rotating Resonator-Oscillator Experiments to Test Lorentz Invariance in Electrodynamics
Comments: Submitted to Lecture Notes in Physics, 36 pages, minor modifications, updated list of references
Submitted: 2005-06-21, last modified: 2005-10-17
In this work we outline the two most commonly used test theories (RMS and SME) for testing Local Lorentz Invariance (LLI) of the photon. Then we develop the general framework of applying these test theories to resonator experiments with an emphasis on rotating experiments in the laboratory. We compare the inherent sensitivity factors of common experiments and propose some new configurations. Finally we apply the test theories to the rotating cryogenic experiment at the University of Western Australia, which recently set new limits in both the RMS and SME frameworks [hep-ph/0506074].
[12]  oai:arXiv.org:hep-ph/0506074  [pdf] - 115055
Test of Lorentz Invariance in Electrodynamics Using Rotating Cryogenic Sapphire Microwave Oscillators
Comments: Final published version, 4 pages, references added
Submitted: 2005-06-07, last modified: 2005-07-21
We present the first results from a rotating Michelson-Morley experiment that uses two orthogonally orientated cryogenic sapphire resonator-oscillators operating in whispering gallery modes near 10 GHz. The experiment is used to test for violations of Lorentz Invariance in the frame-work of the photon sector of the Standard Model Extension (SME), as well as the isotropy term of the Robertson-Mansouri-Sexl (RMS) framework. In the SME we set a new bound on the previously unmeasured $\tilde{\kappa}_{e-}^{ZZ}$ component of $2.1(5.7)\times10^{-14}$, and set more stringent bounds by up to a factor of 7 on seven other components. In the RMS a more stringent bound of $-0.9(2.0)\times 10^{-10}$ on the isotropy parameter, $P_{MM}=\delta - \beta + {1/2}$ is set, which is more than a factor of 7 improvement. More detailed description of the experiment and calculations can be found in: hep-ph/0506200
[13]  oai:arXiv.org:hep-ph/0306230  [pdf] - 114471
Global Representation of the Fine Structure Constant and its Variation
Comments: Final accepted version for Metrologia. This version includes a proof that the representation of the fine structure constant is global across all unit systems, using Jackson's global representation of Maxwell's equations (which is also valid for all unit systems). The version is shorter than the previous, thus the discussion throughout is more brief
Submitted: 2003-06-24, last modified: 2005-02-06
The fine structure constant, alpha, is shown to be proportional to the ratio of the quanta of electric and magnetic flux of force of the electron, and provides a new representation, which is global across all unit systems. Consequently, a variation in alpha was shown to manifest due to a differential change in the fraction of the quanta of electric and magnetic flux of force, while a variation in hcross.c was shown to manifest due to the common mode change. The representation is discussed with respect to the running of the fine structure constant at high energies (small distances), and a putative temporal drift. It is shown that the running of the fine structure constant is due to equal components of electric screening (polarization of vacuum) and magnetic anti-screening (magnetization of vacuum), which cause the perceived quanta of electric charge to increase at small distances, while the magnetic flux quanta decreases. This introduces the concept of the bare magnetic flux quanta as well as the bare electric charge. With regards to temporal drift, it is confirmed that it is impossible to determine which fundamental constant is varying if alpha varies.
[14]  oai:arXiv.org:hep-ph/0408006  [pdf] - 899086
New methods of testing Lorentz violation in electrodynamics
Comments: Accepted for publication in Phys. Rev. D
Submitted: 2004-07-31, last modified: 2004-10-23
We investigate experiments that are sensitive to the scalar and parity-odd coefficients for Lorentz violation in the photon sector of the Standard Model Extension (SME). We show that of the classic tests of special relativity, Ives-Stilwell (IS) experiments are sensitive to the scalar coefficient, but at only parts in 10^5 for the state-of-the-art experiment. We then propose asymmetric Mach-Zehnder interferometers with different electromagnetic properties in the two arms, including recycling techniques based on travelling wave resonators to improve the sensitivity. With present technology we estimate that the scalar and parity odd coefficients may be measured at sensitivity better than parts in 10^11 and 10^15 respectively.
[15]  oai:arXiv.org:gr-qc/0401017  [pdf] - 111424
Whispering Gallery Resonators and Tests of Lorentz Invariance
Comments: 21 pages, 6 figures, accepted for General Relativity and Gravitation (January, 2004). New version with slight changes following the referee's suggestions
Submitted: 2004-01-06, last modified: 2004-02-10
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We give a detailed description of microwave resonators operating in Whispering Gallery modes and then apply it to derive explicit models for Lorentz violating effects in our experiment. Models are calculated in the theoretical framework of Robertson, Mansouri and Sexl and in the standard model extension (SME) of Kostelecky and co-workers. We constrain the parameters of the Mansouri and Sexl test theory to $1/2 - \beta_{MS} + \delta_{MS} = (1.2 \pm 2.2) \times 10^{-9}$ and $\beta_{MS} - \alpha_{MS} - 1 = (1.6 \pm 3.0) \times 10^{-7}$ which is of the same order as the best results from other experiments for the former and represents a 70 fold improvement for the latter. These results correspond to an improvement of our previously published limits [Wolf P. et al., Phys. Rev. Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2.
[16]  oai:arXiv.org:astro-ph/0310112  [pdf] - 1591979
Cold Atom Clocks, Precision Oscillators and Fundamental Tests
Comments: 13 pages, 5 figures
Submitted: 2003-10-04
We describe two experimental tests of the Equivalence Principle that are based on frequency measurements between precision oscillators and/or highly accurate atomic frequency standards. Based on comparisons between the hyperfine frequencies of 87Rb and 133Cs in atomic fountains, the first experiment constrains the stability of fundamental constants. The second experiment is based on a comparison between a cryogenic sapphire oscillator and a hydrogen maser. It tests Local Lorentz Invariance. In both cases, we report recent results which improve significantly over previous experiments.
[17]  oai:arXiv.org:gr-qc/0306047  [pdf] - 111265
Tests of Lorentz Invariance Using a Microwave Resonator: An Update
Comments: 6 pages, 2 figures, to appear in Proc. of the 2003 joint IEEE FCS/EFTF meeting, to appear in Proc. of the 2003 Rencontres de Moriond
Submitted: 2003-06-11
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike test) with respect to a preferred frame candidate. We constrain the corresponding parameters of the Mansouri and Sexl test theory to $\delta - \beta + 1/2 \leq 3.4 \times 10^{-9}$ and $\beta - \alpha - 1 \leq 4.1 \times 10^{-7}$ which is of the same order as the best previous result for the former and represents a 50 fold improvement for the latter. These results correspond to an improvement of our previously published limits [Wolf P. et al., Phys. Rev. Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2. We describe the changes of the experiment, and show the new data that lead to that improvement.
[18]  oai:arXiv.org:astro-ph/0003106  [pdf] - 1943516
Initial operation of the International Gravitational Event Collaboration
Comments: 8 pages, 2 figures, 3 tables; Proceeding of the GWDAW'99. Submitted to the International Journal of Modern Physics
Submitted: 2000-03-08
The International Gravitational Event Collaboration, IGEC, is a coordinated effort by research groups operating gravitational wave detectors working towards the detection of millisecond bursts of gravitational waves. Here we report on the current IGEC resonant bar observatory, its data analysis procedures, the main properties of the first exchanged data set. Even though the available data set is not complete, in the years 1997 and 1998 up to four detectors were operating simultaneously. Preliminary results are mentioned.