Normalized to: Thornhill, J.
[1]
oai:arXiv.org:2001.04510 [pdf] - 2054159
A NECTAr-based upgrade for the Cherenkov cameras of the H.E.S.S.
12-meter telescopes
Ashton, Terry;
Backes, Michael;
Balzer, Arnim;
Berge, David;
Bolmont, Julien;
Bonnefoy, Simon;
Brun, Francois;
Chaminade, Thomas;
Delagnes, Eric;
Fontaine, Gerard;
Füßling, Matthias;
Giavitto, Gianluca;
Giebels, Berrie;
Glicenstein, Jean-Francois;
Gräber, Tobias;
Hinton, Jim;
Jahnke, Albert;
Klepser, Stefan;
Kossatz, Marko;
Kretzschmann, Axel;
Lefranc, Valentin;
Leich, Holger;
Lenain, Jean-Philippe;
Lüdecke, Hartmut;
Lypova, Iryna;
Manigot, Pascal;
Marandon, Vincent;
Moulin, Emmanuel;
Murach, Thomas;
de Naurois, Mathieu;
Nayman, Patrick;
Ohm, Stefan;
Penno, Marek;
Ross, Duncan;
Salek, David;
Schade, Markus;
Schwab, Thomas;
Shiningayamwe, Kleopas;
Stegmann, Christian;
Steppa, Constantin;
Tavernet, Jean-Paul;
Thornhill, Julian;
Toussnel, Francois;
Vincent, Pascal
Submitted: 2020-01-13
The High Energy Stereoscopic System (H.E.S.S.) is one of the three arrays of
imaging atmospheric Cherenkov telescopes (IACTs) currently in operation. It is
composed of four 12-meter telescopes and a 28-meter one, and is sensitive to
gamma rays in the energy range ~30 GeV - 100 TeV. The cameras of the 12-m
telescopes recently underwent a substantial upgrade, with the goal of improving
their performance and robustness. The upgrade involved replacing all camera
components except for the photomultiplier tubes (PMTs). This meant developing
new hardware for the trigger, readout, power, cooling and mechanical systems,
and new software for camera control and data acquisition. Several novel
technologies were employed in the cameras: the readout is built around the new
NECTAr digitizer chip, developed for the next generation of IACTs; the camera
electronics is fully controlled and read out via Ethernet using a combination
of FPGA and embedded ARM computers; the software uses modern libraries such as
Apache Thrift, ZMQ and Protocol buffers. This work describes in detail the
design and the performance of the upgraded cameras.
[2]
oai:arXiv.org:1708.04550 [pdf] - 1783695
Performance of the upgraded H.E.S.S. cameras
Bonnefoy, S.;
Ashton, T.;
Backes, M.;
Balzer, A.;
Berge, D.;
Brun, F.;
Chaminade, T.;
Delagnes, E.;
Fontaine, G.;
Füßling, M.;
Giavitto, G.;
Giebels, B.;
Glicenstein, J. F.;
Gräber, T.;
Hinton, J. A.;
Jahnke, A.;
Klepser, S.;
Kossatz, M.;
Kretzschmann, A.;
Lefranc, V.;
Leich, H.;
Lenain, J. P.;
Lüdecke, H.;
Lypova, I.;
Manigot, P.;
Marandon, V.;
Moulin, E.;
de Naurois, M.;
Nayman, P.;
Ohm, S.;
Penno, M.;
Ross, D.;
Salek, D.;
Schade, M.;
Schwab, T.;
Shiningayamwe, K.;
Stegmann, C.;
Steppa, C.;
Thornhill, J.;
Toussenel, F.
Submitted: 2017-08-15
The 14 years old cameras of the H.E.S.S. 12-m telescopes have been upgraded
in 2015/2016, with the goals of reducing the system failure rate, reducing the
dead time and improving the overall performance of the array. This conference
contribution describes the various tests that were carried out on the cameras
and their sub-components both in the lab and on site. It also gives an overview
of the commissioning and calibration procedures adopted during and after the
installation, including e.g. flat-fielding and trigger threshold scans.
Finally, it reports in detail about the overall performance of the four new
H.E.S.S. I cameras, using very recent data.
[3]
oai:arXiv.org:1707.04415 [pdf] - 1779472
Hardware and software architecture of the upgraded H.E.S.S. cameras
Klepser, S.;
Ashton, T.;
Backes, M.;
Balzer, A.;
Berge, D.;
Bonnefoy, S.;
Brun, F.;
Chaminade, T.;
Delagnes, E.;
Fontaine, G.;
Füßling, M.;
Giavitto, G.;
Giebels, B.;
Glicenstein, J. F.;
Gräber, T.;
Hinton, J. A.;
Jahnke, A.;
Kossatz, M.;
Kretzschmann, A.;
Lefranc, V.;
Leich, H.;
Lenain, J. P.;
Lüdecke, H.;
Lypova, I.;
Manigot, P.;
Marandon, V.;
Moulin, E.;
de Naurois, M.;
Nayman, P.;
Ohm, S.;
Penno, M.;
Ross, D.;
Salek, D.;
Schade, M.;
Schwab, T.;
Shiningayamwe, K.;
Stegmann, C.;
Steppa, C.;
Thornhill, J.;
Toussenel, F.
Submitted: 2017-07-14
In 2015/16, the photomultiplier cameras of the H.E.S.S. Cherenkov telescopes
CT1-4 have undergone a major upgrade. The entire electronics has been replaced,
using NECTAr chips for the front-end readout. A new ventilation system has been
installed and several auxiliary components have been replaced. Besides this,
the internal control and readout software was rewritten from scratch in a
modern and modular way. Ethernet technology was used wherever possible to
ensure both flexibility, stability and high bandwidth. An overview of the
installed components will be given.
[5]
oai:arXiv.org:1610.01452 [pdf] - 1580337
Inauguration and First Light of the GCT-M Prototype for the Cherenkov
Telescope Array
Watson, J. J.;
De Franco, A.;
Abchiche, A.;
Allan, D.;
Amans, J. -P.;
Armstrong, T. P.;
Balzer, A.;
Berge, D.;
Boisson, C.;
Bousquet, J. -J.;
Brown, A. M.;
Bryan, M.;
Buchholtz, G.;
Chadwick, P. M.;
Costantini, H.;
Cotter, G.;
Daniel, M. K.;
De Frondat, F.;
Dournaux, J. -L.;
Dumas, D.;
Ernenwein, J. -P.;
Fasola, G.;
Funk, S.;
Gironnet, J.;
Graham, J. A.;
Greenshaw, T.;
Hervet, O.;
Hidaka, N.;
Hinton, J. A.;
Huet, J. -M.;
Jegouzo, I.;
Jogler, T.;
Kraus, M.;
Lapington, J. S.;
Laporte, P.;
Lefaucheur, J.;
Markoff, S.;
Melse, T.;
Mohrmann, L.;
Molyneux, P.;
Nolan, S. J.;
Okumura, A.;
Osborne, J. P.;
Parsons, R. D.;
Rosen, S.;
Ross, D.;
Rowell, G.;
Rulten, C. B.;
Sato, Y.;
Sayéde, F.;
Schmoll, J.;
Schoorlemmer, H.;
Servillat, M.;
Sol, H.;
Stamatescu, V.;
Stephan, M.;
Stuik, R.;
Sykes, J.;
Tajima, H.;
Thornhill, J.;
Tibaldo, L.;
Trichard, C.;
Vink, J.;
White, R.;
Yamane, N.;
Zech, A.;
Zink, A.;
Zorn, J.;
Consortium, the CTA
Submitted: 2016-10-05
The Gamma-ray Cherenkov Telescope (GCT) is a candidate for the Small Size
Telescopes (SSTs) of the Cherenkov Telescope Array (CTA). Its purpose is to
extend the sensitivity of CTA to gamma-ray energies reaching 300 TeV. Its
dual-mirror optical design and curved focal plane enables the use of a compact
camera of 0.4 m diameter, while achieving a field of view of above 8 degrees.
Through the use of the digitising TARGET ASICs, the Cherenkov flash is sampled
once per nanosecond continuously and then digitised when triggering conditions
are met within the analogue outputs of the photosensors. Entire waveforms
(typically covering 96 ns) for all 2048 pixels are then stored for analysis,
allowing for a broad spectrum of investigations to be performed on the data.
Two prototypes of the GCT camera are under development, with differing
photosensors: Multi-Anode Photomultipliers (MAPMs) and Silicon Photomultipliers
(SiPMs). During November 2015, the GCT MAPM (GCT-M) prototype camera was
integrated onto the GCT structure at the Observatoire de Paris-Meudon, where it
observed the first Cherenkov light detected by a prototype instrument for CTA.
[6]
oai:arXiv.org:1610.01398 [pdf] - 1580334
The Gamma-ray Cherenkov Telescope for the Cherenkov Telescope Array
Tibaldo, L.;
Abchiche, A.;
Allan, D.;
Amans, J. -P.;
Armstrong, T. P.;
Balzer, A.;
Berge, D.;
Boisson, C.;
Bousquet, J. -J.;
Brown, A. M.;
Bryan, M.;
Buchholtz, G.;
Chadwick, P. M.;
Costantini, H.;
Cotter, G.;
Daniel, M. K.;
De Franco, A.;
De Frondat, F.;
Dournaux, J. -L.;
Dumas, D.;
Ernenwein, J. -P.;
Fasola, G.;
Funk, S.;
Gironnet, J.;
Graham, J. A.;
Greenshaw, T.;
Hervet, O.;
Hidaka, N.;
Hinton, J. A.;
Huet, J. -M.;
Jankowsky, D.;
Jegouzo, I.;
Jogler, T.;
Kraus, M.;
Lapington, J. S.;
Laporte, P.;
Lefaucheur, J.;
Markoff, S.;
Melse, T.;
Mohrmann, L.;
Molyneux, P.;
Nolan, S. J.;
Okumura, A.;
Osborne, J. P.;
Parsons, R. D.;
Rosen, S.;
Ross, D.;
Rowell, G.;
Rulten, C. B.;
Sato, Y.;
Sayede, F.;
Schmoll, J.;
Schoorlemmer, H.;
Servillat, M.;
Sol, H.;
Stamatescu, V.;
Stephan, M.;
Stuik, R.;
Sykes, J.;
Tajima, H.;
Thornhill, J.;
Trichard, C.;
Vink, J.;
Watson, J. J.;
White, R.;
Yamane, N.;
Zech, A.;
Zink, A.;
Zorn, J.;
Consortium, the CTA
Submitted: 2016-10-05
The Cherenkov Telescope Array (CTA) is a forthcoming ground-based observatory
for very-high-energy gamma rays. CTA will consist of two arrays of imaging
atmospheric Cherenkov telescopes in the Northern and Southern hemispheres, and
will combine telescopes of different types to achieve unprecedented performance
and energy coverage. The Gamma-ray Cherenkov Telescope (GCT) is one of the
small-sized telescopes proposed for CTA to explore the energy range from a few
TeV to hundreds of TeV with a field of view $\gtrsim 8^\circ$ and angular
resolution of a few arcminutes. The GCT design features dual-mirror
Schwarzschild-Couder optics and a compact camera based on densely-pixelated
photodetectors as well as custom electronics. In this contribution we provide
an overview of the GCT project with focus on prototype development and testing
that is currently ongoing. We present results obtained during the first
on-telescope campaign in late 2015 at the Observatoire de Paris-Meudon, during
which we recorded the first Cherenkov images from atmospheric showers with the
GCT multi-anode photomultiplier camera prototype. We also discuss the
development of a second GCT camera prototype with silicon photomultipliers as
photosensors, and plans toward a contribution to the realisation of CTA.
[7]
oai:arXiv.org:1608.03420 [pdf] - 1521294
The GCT camera for the Cherenkov Telescope Array
Brown, Anthony M.;
Abchiche, A.;
Allan, D.;
Amans, J. P.;
Armstrong, T. P.;
Balzer, A.;
Berge, D.;
Boisson, C.;
Bousquet, J. -J.;
Bryan, M.;
Buchholtz, G.;
Chadwick, P. M.;
Costantini, H.;
Cotter, G.;
Daniel, M. K.;
De Franco, A.;
De Frondat, F.;
Dournaux, J. -L.;
Dumas, D.;
Fasola, G.;
Funk, S.;
Gironnet, J.;
Graham, J. A.;
Greenshaw, T.;
Hervet, O.;
Hidaka, N.;
Hinton, J. A.;
Huet, J. -M.;
Jegouzo, I.;
Jogler, T.;
Kraus, M.;
Lapington, J. S.;
Laporte, P.;
Lefaucheur, J.;
Markoff, S.;
Melse, T.;
Mohrmann, L.;
Molyneux, P.;
Nolan, S. J.;
Okumura, A.;
Osborne, J. P.;
Parsons, R. D.;
Rosen, S.;
Ross, D.;
Rowell, G.;
Sato, Y.;
Sayede, F.;
Schmoll, J.;
Schoorlemmer, H.;
Servillat, M.;
Sol, H.;
Stamatescu, V.;
Stephan, M.;
Stuik, R.;
Sykes, J.;
Tajima, H.;
Thornhill, J.;
Tibaldo, L.;
Trichard, C.;
Vink, J.;
Watson, J. J.;
White, R.;
Yamane, N.;
Zech, A.;
Zink, A.;
Zorn, J.
Submitted: 2016-08-11
The Gamma-ray Cherenkov Telescope (GCT) is proposed for the Small-Sized
Telescope component of the Cherenkov Telescope Array (CTA). GCT's dual-mirror
Schwarzschild-Couder (SC) optical system allows the use of a compact camera
with small form-factor photosensors. The GCT camera is ~0.4 m in diameter and
has 2048 pixels; each pixel has a ~0.2 degree angular size, resulting in a wide
field-of-view. The design of the GCT camera is high performance at low cost,
with the camera housing 32 front-end electronics modules providing full
waveform information for all of the camera's 2048 pixels. The first GCT camera
prototype, CHEC-M, was commissioned during 2015, culminating in the first
Cherenkov images recorded by a SC telescope and the first light of a CTA
prototype. In this contribution we give a detailed description of the GCT
camera and present preliminary results from CHEC-M's commissioning.
[9]
oai:arXiv.org:1509.01480 [pdf] - 1271733
The first GCT camera for the Cherenkov Telescope Array
De Franco, A.;
White, R.;
Allan, D.;
Armstrong, T.;
Ashton, T.;
Balzer, A.;
Berge, D.;
Bose, R.;
Brown, A. M.;
Buckley, J.;
Chadwick, P. M.;
Cooke, P.;
Cotter, G.;
Daniel, M. K.;
Funk, S.;
Greenshaw, T.;
Hinton, J.;
Kraus, M.;
Lapington, J.;
Molyneux, P.;
Moore, P.;
Nolan, S.;
Okumura, A.;
Ross, D.;
Rulten, C.;
Schmoll, J.;
Schoorlemmer, H.;
Stephan, M.;
Sutcliffe, P.;
Tajima, H.;
Thornhill, J.;
Tibaldo, L.;
Varner, G.;
Watson, J.;
Zink, A.
Submitted: 2015-09-04
The Gamma Cherenkov Telescope (GCT) is proposed to be part of the Small Size
Telescope (SST) array of the Cherenkov Telescope Array (CTA). The GCT
dual-mirror optical design allows the use of a compact camera of diameter
roughly 0.4 m. The curved focal plane is equipped with 2048 pixels of
~0.2{\deg} angular size, resulting in a field of view of ~9{\deg}. The GCT
camera is designed to record the flashes of Cherenkov light from
electromagnetic cascades, which last only a few tens of nanoseconds. Modules
based on custom ASICs provide the required fast electronics, facilitating
sampling and digitisation as well as first level of triggering. The first GCT
camera prototype is currently being commissioned in the UK. On-telescope tests
are planned later this year. Here we give a detailed description of the camera
prototype and present recent progress with testing and commissioning.
[10]
oai:arXiv.org:1509.01232 [pdf] - 1271229
A major electronics upgrade for the H.E.S.S. Cherenkov telescopes 1-4
Giavitto, G.;
Ashton, T.;
Balzer, A.;
Berge, D.;
Brun, F.;
Chaminade, T.;
Delagnes, E.;
Fontaine, G.;
Füßling, M.;
Giebels, B.;
Glicenstein, J. F.;
Gräber, T.;
Hinton, J. A.;
Jahnke, A.;
Klepser, S.;
Kossatz, M.;
Kretzschmann, A.;
Lefranc, V.;
Leich, H.;
Lüdecke, H.;
Manigot, P.;
Marandon, V.;
Moulin, E.;
de, M.;
Nayman, P.;
Penno, M.;
Ross, D.;
Salek, D.;
Schade, M.;
Schwab, T.;
Simoni, R.;
Stegmann, C.;
Thornhill, J.;
Toussenel, F.
Submitted: 2015-09-03
The High Energy Stereoscopic System (H.E.S.S.) is an array of imaging
atmospheric Cherenkov telescopes (IACTs) located in the Khomas Highland in
Namibia. It consists of four 12-m telescopes (CT1-4), which started operations
in 2003, and a 28-m diameter one (CT5), which was brought online in 2012. It is
the only IACT system featuring telescopes of different sizes, which provides
sensitivity for gamma rays across a very wide energy range, from ~30 GeV up to
~100 TeV. Since the camera electronics of CT1-4 are much older than the one of
CT5, an upgrade is being carried out; first deployment was in 2015, full
operation is planned for 2016. The goals of this upgrade are threefold:
reducing the dead time of the cameras, improving the overall performance of the
array and reducing the system failure rate related to aging. Upon completion,
the upgrade will assure the continuous operation of H.E.S.S. at its full
sensitivity until and possibly beyond the advent of CTA. In the design of the
new components, several CTA concepts and technologies were used and are thus
being evaluated in the field: The upgraded read-out electronics is based on the
NECTAR readout chips; the new camera front- and back-end control subsystems are
based on an FPGA and an embedded ARM computer; the communication between
subsystems is based on standard Ethernet technologies. These hardware solutions
offer good performance, robustness and flexibility. The design of the new
cameras is reported here.
[11]
oai:arXiv.org:1310.1632 [pdf] - 1338874
Nuclear astrophysics with radioactive ions at FAIR
Reifarth, R.;
Altstadt, S.;
Göbel, K.;
Heftrich, T.;
Heil, M.;
Koloczek, A.;
Langer, C.;
Plag, R.;
Pohl, M.;
Sonnabend, K.;
Weigand, M.;
Adachi, T.;
Aksouh, F.;
Al-Khalili, J.;
AlGarawi, M.;
AlGhamdi, S.;
Alkhazov, G.;
Alkhomashi, N.;
Alvarez-Pol, H.;
Alvarez-Rodriguez, R.;
Andreev, V.;
Andrei, B.;
Atar, L.;
Aumann, T.;
Avdeichikov, V.;
Bacri, C.;
Bagchi, S.;
Barbieri, C.;
Beceiro, S.;
Beck, C.;
Beinrucker, C.;
Belier, G.;
Bemmerer, D.;
Bendel, M.;
Benlliure, J.;
Benzoni, G.;
Berjillos, R.;
Bertini, D.;
Bertulani, C.;
Bishop, S.;
Blasi, N.;
Bloch, T.;
Blumenfeld, Y.;
Bonaccorso, A.;
Boretzky, K.;
Botvina, A.;
Boudard, A.;
Boutachkov, P.;
Boztosun, I.;
Bracco, A.;
Brambilla, S.;
Monago, J. Briz;
Caamano, M.;
Caesar, C.;
Camera, F.;
Casarejos, E.;
Catford, W.;
Cederkall, J.;
Cederwall, B.;
Chartier, M.;
Chatillon, A.;
Cherciu, M.;
Chulkov, L.;
Coleman-Smith, P.;
Cortina-Gil, D.;
Crespi, F.;
Crespo, R.;
Cresswell, J.;
Csatlós, M.;
Déchery, F.;
Davids, B.;
Davinson, T.;
Derya, V.;
Detistov, P.;
Fernandez, P. Diaz;
DiJulio, D.;
Dmitry, S.;
Doré, D.;
Duenas, J.;
Dupont, E.;
Egelhof, P.;
Egorova, I.;
Elekes, Z.;
Enders, J.;
Endres, J.;
Ershov, S.;
Ershova, O.;
Fernandez-Dominguez, B.;
Fetisov, A.;
Fiori, E.;
Fomichev, A.;
Fonseca, M.;
Fraile, L.;
Freer, M.;
Friese, J.;
Borge, M. G.;
Redondo, D. Galaviz;
Gannon, S.;
Garg, U.;
Gasparic, I.;
Gasques, L.;
Gastineau, B.;
Geissel, H.;
Gernhäuser, R.;
Ghosh, T.;
Gilbert, M.;
Glorius, J.;
Golubev, P.;
Gorshkov, A.;
Gourishetty, A.;
Grigorenko, L.;
Gulyas, J.;
Haiduc, M.;
Hammache, F.;
Harakeh, M.;
Hass, M.;
Heine, M.;
Hennig, A.;
Henriques, A.;
Herzberg, R.;
Holl, M.;
Ignatov, A.;
Ignatyuk, A.;
Ilieva, S.;
Ivanov, M.;
Iwasa, N.;
Jakobsson, B.;
Johansson, H.;
Jonson, B.;
Joshi, P.;
Junghans, A.;
Jurado, B.;
Körner, G.;
Kalantar, N.;
Kanungo, R.;
Kelic-Heil, A.;
Kezzar, K.;
Khan, E.;
Khanzadeev, A.;
Kiselev, O.;
Kogimtzis, M.;
Körper, D.;
Kräckmann, S.;
Kröll, T.;
Krücken, R.;
Krasznahorkay, A.;
Kratz, J.;
Kresan, D.;
Krings, T.;
Krumbholz, A.;
Krupko, S.;
Kulessa, R.;
Kumar, S.;
Kurz, N.;
Kuzmin, E.;
Labiche, M.;
Langanke, K.;
Lazarus, I.;
Bleis, T. Le;
Lederer, C.;
Lemasson, A.;
Lemmon, R.;
Liberati, V.;
Litvinov, Y.;
Löher, B.;
Herraiz, J. Lopez;
Münzenberg, G.;
Machado, J.;
Maev, E.;
Mahata, K.;
Mancusi, D.;
Marganiec, J.;
Perez, M. Martinez;
Marusov, V.;
Mengoni, D.;
Million, B.;
Morcelle, V.;
Moreno, O.;
Movsesyan, A.;
Nacher, E.;
Najafi, M.;
Nakamura, T.;
Naqvi, F.;
Nikolski, E.;
Nilsson, T.;
Nociforo, C.;
Nolan, P.;
Novatsky, B.;
Nyman, G.;
Ornelas, A.;
Palit, R.;
Pandit, S.;
Panin, V.;
Paradela, C.;
Parkar, V.;
Paschalis, S.;
Pawłowski, P.;
Perea, A.;
Pereira, J.;
Petrache, C.;
Petri, M.;
Pickstone, S.;
Pietralla, N.;
Pietri, S.;
Pivovarov, Y.;
Potlog, P.;
Prokofiev, A.;
Rastrepina, G.;
Rauscher, T.;
Ribeiro, G.;
Ricciardi, M.;
Richter, A.;
Rigollet, C.;
Riisager, K.;
Rios, A.;
Ritter, C.;
Frutos, T. Rodríguez;
Vignote, J. Rodriguez;
Röder, M.;
Romig, C.;
Rossi, D.;
Roussel-Chomaz, P.;
Rout, P.;
Roy, S.;
Söderström, P.;
Sarkar, M. Saha;
Sakuta, S.;
Salsac, M.;
Sampson, J.;
Saez, J. Sanchez del Rio;
Rosado, J. Sanchez;
Sanjari, S.;
Sarriguren, P.;
Sauerwein, A.;
Savran, D.;
Scheidenberger, C.;
Scheit, H.;
Schmidt, S.;
Schmitt, C.;
Schnorrenberger, L.;
Schrock, P.;
Schwengner, R.;
Seddon, D.;
Sherrill, B.;
Shrivastava, A.;
Sidorchuk, S.;
Silva, J.;
Simon, H.;
Simpson, E.;
Singh, P.;
Slobodan, D.;
Sohler, D.;
Spieker, M.;
Stach, D.;
Stan, E.;
Stanoiu, M.;
Stepantsov, S.;
Stevenson, P.;
Strieder, F.;
Stuhl, L.;
Suda, T.;
Sümmerer, K.;
Streicher, B.;
Taieb, J.;
Takechi, M.;
Tanihata, I.;
Taylor, J.;
Tengblad, O.;
Ter-Akopian, G.;
Terashima, S.;
Teubig, P.;
Thies, R.;
Thoennessen, M.;
Thomas, T.;
Thornhill, J.;
Thungstrom, G.;
Timar, J.;
Togano, Y.;
Tomohiro, U.;
Tornyi, T.;
Tostevin, J.;
Townsley, C.;
Trautmann, W.;
Trivedi, T.;
Typel, S.;
Uberseder, E.;
Udias, J.;
Uesaka, T.;
Uvarov, L.;
Vajta, Z.;
Velho, P.;
Vikhrov, V.;
Volknandt, M.;
Volkov, V.;
von Neumann-Cosel, P.;
von Schmid, M.;
Wagner, A.;
Wamers, F.;
Weick, H.;
Wells, D.;
Westerberg, L.;
Wieland, O.;
Wiescher, M.;
Wimmer, C.;
Wimmer, K.;
Winfield, J. S.;
Winkel, M.;
Woods, P.;
Wyss, R.;
Yakorev, D.;
Yavor, M.;
Cardona, J. Zamora;
Zartova, I.;
Zerguerras, T.;
Zgura, I.;
Zhdanov, A.;
Zhukov, M.;
Zieblinski, M.;
Zilges, A.;
Zuber, K.
Submitted: 2013-10-06
The nucleosynthesis of elements beyond iron is dominated by neutron captures
in the s and r processes. However, 32 stable, proton-rich isotopes cannot be
formed during those processes, because they are shielded from the s-process
flow and r-process beta-decay chains. These nuclei are attributed to the p and
rp process.
For all those processes, current research in nuclear astrophysics addresses
the need for more precise reaction data involving radioactive isotopes.
Depending on the particular reaction, direct or inverse kinematics, forward or
time-reversed direction are investigated to determine or at least to constrain
the desired reaction cross sections.
The Facility for Antiproton and Ion Research (FAIR) will offer unique,
unprecedented opportunities to investigate many of the important reactions. The
high yield of radioactive isotopes, even far away from the valley of stability,
allows the investigation of isotopes involved in processes as exotic as the r
or rp processes.