Normalized to: Thelen, M.
[1]
oai:arXiv.org:1508.03070 [pdf] - 1264215
The Mid-Infrared Instrument for the James Webb Space Telescope, VI: The
Medium Resolution Spectrometer
Wells, Martyn;
Pel, J. -W.;
Glasse, Alistair;
Wright, G. S.;
Aitink-Kroes, Gabby;
Azzollini, Ruyman;
Beard, Steven;
Brandl, B. R.;
Gallie, Angus;
Geers, V. C.;
Glauser, A. M.;
Hastings, Peter;
Henning, Th.;
Jager, Rieks;
Justtanont, K.;
Kruizinga, Bob;
Lahuis, Fred;
Lee, David;
Martinez-Delgado, I.;
Martinez-Galarza, J. R.;
Meijers, M.;
Morrison, Jane E.;
Mueller, Friedrich;
Nakos, Thodori;
O'Sullivan, Brian;
Oudenhuysen, Ad;
Parr-Burman, P.;
Pauwels, Evert;
Rohloff, R. -R.;
Schmalzl, Eva;
Sykes, Jon;
Thelen, M. P.;
van Dishoeck, E. F.;
Vandenbussche, Bart;
Venema, Lars B.;
Visser, Huib;
Waters, L. B. F. M.;
Wright, David
Submitted: 2015-08-12
We describe the design and performance of the Medium Resolution Spectrometer
(MRS) for the JWST-MIRI instrument. The MRS incorporates four coaxial spectral
channels in a compact opto-mechanical layout that generates spectral images
over fields of view up to 7.7 X 7.7 arcseconds in extent and at spectral
resolving powers ranging from 1,300 to 3,700. Each channel includes an
all-reflective integral field unit (IFU): an 'image slicer' that reformats the
input field for presentation to a grating spectrometer. Two 1024 X 1024 focal
plane arrays record the output spectral images with an instantaneous spectral
coverage of approximately one third of the full wavelength range of each
channel. The full 5 to 28.5 micron spectrum is then obtained by making three
exposures using gratings and pass-band-determining filters that are selected
using just two three-position mechanisms. The expected on-orbit optical
performance is presented, based on testing of the MIRI Flight Model and
including spectral and spatial coverage and resolution. The point spread
function of the reconstructed images is shown to be diffraction limited and the
optical transmission is shown to be consistent with the design expectations.
[2]
oai:arXiv.org:1508.02488 [pdf] - 1260877
The Mid-Infrared Instrument for the James Webb Space Telescope, III:
MIRIM, The MIRI Imager
Bouchet, P.;
Garcia-Marin, M.;
Lagage, P. -O.;
Amiaux, J.;
Augueres, J. -L.;
Bauwens, E.;
Blommaert, J. A. D. L.;
Chen, C. H.;
Detre, O. H.;
Dicken, D.;
Dubreuil, D.;
Galdemard, Ph.;
Gastaud, R.;
Glasse, A.;
Gordon, K. D.;
Gougnaud, F.;
Guillard, P.;
Justtanont, K.;
Krause, O.;
Leboeuf, D.;
Longval, Y.;
Martin, L.;
Mazy, E.;
Moreau, V.;
Olofsson, G.;
Ray, T. P.;
Reess, J. -M.;
Renotte, E.;
Ressler, M. E.;
Ronayette, S.;
Salasca, S.;
Scheithauer, S.;
Sykes, J.;
Thelen, M. P.;
Wells, M.;
Wright, D.;
Wright, G. S.
Submitted: 2015-08-11
In this article, we describe the MIRI Imager module (MIRIM), which provides
broad-band imaging in the 5 - 27 microns wavelength range for the James Webb
Space Telescope. The imager has a 0"11 pixel scale and a total unobstructed
view of 74"x113". The remainder of its nominal 113"x113" field is occupied by
the coronagraphs and the low resolution spectrometer. We present the instrument
optical and mechanical design. We show that the test data, as measured during
the test campaigns undertaken at CEA-Saclay, at the Rutherford Appleton
Laboratory, and at the NASA Goddard Space Flight Center, indicate that the
instrument complies with its design requirements and goals. We also discuss the
operational requirements (multiple dithers and exposures) needed for optimal
scientific utilization of the MIRIM.
[3]
oai:arXiv.org:1508.02417 [pdf] - 1264208
The Mid-Infrared Instrument for the James Webb Space Telescope, VIII:
The MIRI Focal Plane System
Ressler, M. E.;
Sukhatme, K. G.;
Franklin, B. R.;
Mahoney, J. C.;
Thelen, M. P.;
Bouchet, P.;
Colbert, J. W.;
Cracraft, Misty;
Dicken, D.;
Gastaud, R.;
Goodson, G. B.;
Eccleston, Paul;
Moreau, V.;
Rieke, G. H.;
Schneider, Analyn
Submitted: 2015-08-10
We describe the layout and unique features of the focal plane system for
MIRI. We begin with the detector array and its readout integrated circuit
(combining the amplifier unit cells and the multiplexer), the electronics, and
the steps by which the data collection is controlled and the output signals are
digitized and delivered to the JWST spacecraft electronics system. We then
discuss the operation of this MIRI data system, including detector readout
patterns, operation of subarrays, and data formats. Finally, we summarize the
performance of the system, including remaining anomalies that need to be
corrected in the data pipeline.